首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
组合墙结构房屋抗震性能的振动台试验研究   总被引:1,自引:0,他引:1  
通过三个组合墙模型房屋的振动台试验,分析了组合墙结构体系房屋的动力性能和抗震能力,比较了底一层和底两层框架组合墙房屋和普通组合墙房屋的抗震性能。结果表明,八层组合墙房屋的抗震能力远远超过设计能力,可用于八度地区,底框架组合墙房屋的抗震性能优于普通组合墙房屋,底两层框架组合墙房屋也优于底一层框架组合墙房屋。  相似文献   

2.
Building pounding damages observed in the February 2011 Christchurch earthquake are described in this paper. The extent and severity of pounding damage is presented based on a street survey of Christchurch's central business district. Six damage severity levels and two confidence levels are defined to classify the observed damage. Generally, pounding was observed to be a secondary effect. However, over 6% of the total surveyed buildings were observed to have significant or greater pounding damage. Examples of typical and exceptional pounding damage are identified and discussed. Extensive pounding damage was observed in low‐rise unreinforced masonry buildings that were constructed with no building separation. Modern buildings were also endangered by pounding when building separations were infilled with solid architectural flashings. The damage caused by these flashings was readily preventable. The observed pounding damage is compared to that observed in the September 2010 Darfield earthquake to explore if the damage could have been predicted. It is found that pounding prone buildings can be identified with reasonable accuracy by comparing configurations to characteristics previously noted by researchers. However, detailed pounding damage patterns cannot currently be precisely predicted by these methods. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
In this study the seismic pounding response of adjacent multi-degree-of-freedom(MDOF) buildings with bilinear inter-story resistance characteristics is investigated through dimensional analysis. The application of dimensional analysis leads to a condensed presentation of the response, and the remarkable self-similarity property for bilinear MDOF buildings with inelastic collision is uncovered. It is shown that when the response is expressed in the appropriate dimensionless form, response spectra for any intensity of the excitation collapse to a single master curve. The reduced Π set explicitly describes the interaction between the colliding structures. The effect of pounding on the MDOF building's response is illustrated using three well-divided spectral regions(amplifi ed, de-amplifi ed and unaffected regions). Parametric studies are conducted to investigate the effects of the story stiffness of structures, the story stiffness ratio and mass ratio of adjacent buildings, the structural inelastic characteristics and the gap size values. Results show that(i) the infl uence of system stiffness ratio to the lighter and more fl exible building is more signifi cant in the fi rst spectral region, where the maximum response of the building is amplifi ed because of pounding; and(ii) the velocity and pounding force of the heavier and stiffer building is unexpectedly sensitive to the mass ratio of adjacent buildings.  相似文献   

4.
In cities and urban areas, building structures located at close proximities inevitably interact under dynamic loading by direct pounding and indirectly through the underlying soil. Majority of the previous adjacent building pounding studies that have taken the structure–soil–structure interaction (SSSI) problem into account have used simple lumped mass–spring–dashpot models under plane strain conditions. In this research, the problem of SSSI‐included pounding problem of two adjacent symmetric in plan buildings resting on a soft soil profile excited by uniaxial earthquake loadings is investigated. To this end, a series of SSSI models considering one‐directional nonlinear impact elements between adjacent co‐planar stories and using a method for direct finite element modeling of 3D inelastic underlying soil volume has been developed to accurately study the problem. An advanced inelastic structural behavior parameter, the seismic damage index, has been considered in this study as the key nonlinear structural response of adjacent buildings. Based on the results of SSSI and fixed base case analyses presented herein, two main problems are investigated, namely, the minimum building separation distance for pounding prevention and seismic pounding effects on structural damage in adjacent buildings. The final results show that at least three times, the International Building Code 2009 minimum distance for building separation recommended value is required as a clear distance for adjacent symmetric buildings to prevent the occurrence of seismic pounding. At the International Building Code‐recommended distance, adjacent buildings experienced severe seismic pounding and therefore significant variations in storey shear forces and damage indices. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
The use of collision shear walls (bumper‐type), acting transversely to the side subject to pounding, as a measure to minimize damage of reinforced concrete buildings in contact, is investigated using 5‐story building models. The buildings were designed according to the Greek anti‐seismic and reinforced concrete design codes. Owing to story height differences potential pounding in case of an earthquake will occur between floor slabs, a case specifically chosen because this is when pounding can turn out to be catastrophic. The investigation is carried out using nonlinear dynamic analyses for a real earthquake motion and also a simplified solution for a triangular dynamic force of short duration, comparable to the forces caused by pounding. For such analyses, nonlinear, prismatic beam–column elements are used and the effects of pounding are expressed in terms of changes in rotational ductility factors of the building elements. The local effects of pounding on the collision shear walls are investigated using a detailed nonlinear finite element model of the shear walls and results are expressed in terms of induced stresses. It is found that pounding will cause instantaneous acceleration pulses in the colliding buildings and will somewhat increase ductility demands in the members of the top floor, but all within tolerable limits. At the same time the collision walls will suffer repairable local damage at the points of contact, but will effectively protect both buildings from collapse, which could occur if columns were in the place of the walls. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

6.
Many closely located adjacent buildings have suffered from pounding during past earthquakes because they vibrated out of phase.Furthermore,buildings are usually constructed on soil;hence,there are interactions between the buildings and the underlying soil that should also be considered.This paper examines both the interaction between adjacent buildings due to pounding and the interaction between the buildings through the soil as they affect the buildings’ seismic responses.The developed model consists of adjacent shear buildings resting on a discrete soil model and a linear viscoelastic contact force model that connects the buildings during pounding.The seismic responses of adjacent buildings due to ground accelerations are obtained for two conditions:fixed-based(FB) and structure-soil-structure interaction(SSSI).The results indicate that pounding worsens the buildings’ condition because their seismic responses are amplified after pounding.Moreover,the underlying soil negatively impacts the buildings’ seismic responses during pounding because the ratio of their seismic response under SSSI conditions with pounding to those without pounding is greater than that of the FB condition.  相似文献   

7.
The need to investigate the level of seismic pounding risk of buildings is apparent in future building code calibrations. In order to provide further insight into the pounding risk of adjacent buildings, this study develops a numerical simulation approach to estimate the seismic pounding risk of adjacent buildings separated by a minimum code‐specified separation distance during a certain period of time. It has been demonstrated that the period ratio of adjacent buildings is an important parameter that affects the pounding risk of adjacent buildings. However, there is no specific consideration for the period ratio in the related seismic pounding provisions of the 1997 Uniform Building Code. Results also reveal that, for two adjacent buildings, the probability distribution of required distance to avoid seismic pounding fits very well with the type I extreme value distribution. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

8.
Post-earthquake damages investigation in past and recent earthquakes has illustrated that the building structures are vulnerable to severe damage and/or collapse during moderate to strong ground motion. Among the possible structural damages, seismic induced pounding has been commonly observed in several earthquakes. A parametric study on buildings pounding response as well as proper seismic hazard mitigation practice for adjacent buildings is carried out. Three categories of recorded earthquake excitation are used for input excitations. The effect of impact is studied using linear and nonlinear contact force model for different separation distances and compared with nominal model without pounding consideration. The severity of the impact depends on the dynamic characteristics of the adjacent buildings in combination with the earthquake characteristics. Pounding produces acceleration and shear forces/stresses at various story levels that are greater than those obtained from the no pounding case, while the peak drift depends on the input excitation characteristics. Also, increasing gap width is likely to be effective when the separation is sufficiently wide to eliminate contact. Furthermore, it is effective to provide a shock absorber device system for the mitigation of impact effects between adjacent buildings with relatively narrow seismic gaps, where the sudden changes of stiffness during poundings can be smoothed. This prevents, to some extent, the acceleration peaks due to impact. The pounding forces exerted on the adjacent buildings can be satisfactorily reduced.  相似文献   

9.
刘汉雄  张岳红 《地震研究》1992,15(3):298-305
本文根据对昆明的5层楼房和昆明市工人文化宫18层建筑的脉动观测,结合作者对昆明市几种地基土的脉动观测研究,提出了强震的卓越周期昆明地基土和建筑物的固有周期之间与震害的关系,可供有关部门在城市规划建设和编制抗震防灾规划中参考。  相似文献   

10.
Analysis and comparison of the dynamic responses of three well instrumented (with accelerographs) high-rise buildings shaken during the 1984 Morgan Hill earthquake are presented. The buildings examined in the present work are (i) the Town Park Towers Apartment building, a 10-storey, concrete shear wall building; (ii) the Great Western Savings and Loan building, a 10-storey building with concrete frames and shear walls; and (iii) the Santa Clara County Office building, a 13-storey, moment-resistant steel frame building. The structures are located within 2 km of each other and, as may be confirmed by visual inspection of the recorded seismograms, experienced similar ground motions. One-dimensional and three-dimensional linear structural models are fitted to the observations using the modal minimization method' for structural identification, in order to determine optimal estimates of the parameters of the dominant modes of the buildings. The time-varying character of these parameters over the duration of the response is also investigated. Comparison of the recorded earthquake response of the structures reveals that the type of lateral-load-resisting system has an important effect on the dynamic behaviour of the structures because it controls the spacing of the characteristic modes on the frequency axis. The Santa Clara County Office building has closely spaced natural frequencies and exhibits strong torsional response and modal coupling. Its dynamic behaviour is contrasted with that of the Great Western Savings and Loan building which has well separated natural frequencies and exhibits small torsional response and no modal coupling. Strong modal coupling causes a beating-type phenomenon and makes earthquake response of structures different from that envisioned by codes.  相似文献   

11.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
The reports after major earthquakes indicate that the earthquake-induced pounding between insufficiently separated buildings may lead to significant damage or even total collapse of structures. An intensive study has recently been carried out on mitigation of pounding hazards so as to minimize the structural damages or prevent collisions at all. The aim of this paper is to investigate the effectiveness of the method when two adjacent three-storey buildings with different (substantially different) dynamic properties are connected at each storey level by link elements (springs, dashpots or viscoelastic elements). The results of the study indicate that connecting the structures by additional link elements can be very beneficial for the lighter and more flexible building. The largest decrease in the response of the structure has been obtained for links with large stiffness or damping values, which stands for the case when two buildings are fully connected and vibrate in-phase. Moreover, by comparing the effectiveness of different types of link elements, it has been confirmed that the use of viscoelastic elements reduces the peak displacement of the structure at lower stiffness and damping values comparing to the case when spring and dashpot elements are applied alone. On the other hand, the results of the study demonstrate that applying the additional link elements does not really change the response of the heavier and stiffer building. The final conclusion of the study indicates that linking two buildings allows us to reduce the in-between gap size substantially while structural pounding can be still prevented.  相似文献   

13.
The response of adjacent buildings in city blocks to several strong earthquakes is analysed, taking into account the mutual collisions, or pounding, resulting from insufficient or non-existing separation distances. The buildings are idealized as lumped-mass, shear beam type, multi-degree-of-freedom (MDOF) systems with bilinear force-deformation characteristics and with bases supported on translational and rocking spring-dashpots. Collisions between adjacent masses can occur at any level and are simulated by means of viscoelastic impact elements. Using five real earthquake motions the effects of the following factors are investigated: building configuration and relative size, seismic separation distance and impact element properties. It is found that pounding can cause high overstresses, mainly when the colliding buildings have significantly different heights, periods or masses. This suggests a possibility for introducing a set of conditions into the codes, combined with some special measures, as an alternative to the seismic separation requirement.  相似文献   

14.
带裙房高层建筑地震反应控制振动台试验研究   总被引:1,自引:1,他引:0  
2002年9月在香港理工大学成功地进行了带裙房高层建筑地震反应控制试验研究。设计和制作的结构模型是带3层裙房的12层高楼剪切模型,在裙房顶层与主楼之间安装单MR阻尼器形成MR阻尼器耦联结构模型。MR阻尼器采用美国LORD公司摩擦型MR阻尼器,并且选用其配套产品计算机电流控制器对其进行控制,控制系统采用德国dSPACE公司实时控制系统。对独立主楼、独立裙房和原结构模型的动力特性进行了辨识;对结构模型进行了El Centro地震动作用下的地震反应振动台试验;以作者提出的MR阻尼器半主动逻辑控制算法,对MR阻尼器耦联的结构模型进行了地震反应振动台试验。试验结果表明:用MR阻尼器耦联主楼与裙房,采用半主动逻辑控制方法进行控制,能有效抑制主楼的鞭梢效应并使主楼和裙房的地震反应减小。  相似文献   

15.
Base isolation can effectively reduce the seismic forces on a superstructure,particularly in low-to medium-rise buildings.However,under strong near-fault ground motions,pounding may occur at the isolation level between the baseisolated building(BIB)and its surrounding retaining walls.To effectively investigate the behavior of the BIB pounding with adjacent structures,after assessing some commonly used impact models,a modified Kelvin impact model is proposed in this paper.Relevant parameters in the modifi...  相似文献   

16.
This study compares seismic losses considering initial construction costs and direct-repair costs for New Zealand steel moment-resisting frame buildings with friction connections and those with extended bolted-end-plate connections. A total of 12 buildings have been designed and analysed considering both connection types, two building heights (4-storey and 12-storey), and three locations around New Zealand (Auckland, Christchurch, and Wellington). It was found that buildings with friction connections required design to a higher design ductility, yet are generally stiffer due to larger beams being required to satisfy higher connection overstrength requirements. This resulted in the frames with friction connections experiencing lower interstorey drifts on most floors but similar peak total floor accelerations, and subsequently incurring lower drift-related seismic repair losses. Frames with friction connections tended to have lower expected net-present-costs within 50 years of the building being in service for shorter buildings and/or if located in regions of high seismicity. None of the frames with friction connections in Auckland showed any benefits due to the low seismicity of the region.  相似文献   

17.
The effects of seismic pounding on the structural performance of a base-isolated reinforced concrete (RC) building are investigated, with a view to evaluate the influence of adjacent structures and separation between structures on the pounding response. In particular, seismic pounding of a typical four-story base-isolated RC building with retaining walls at the base and with a four-story fixed-base RC building is studied. Three-dimensional finite element analyses are carried out considering material and geometric nonlinearities. The structural performance of the base-isolated building is evaluated considering various earthquake excitations. It is found that the performance of the base-isolated building is substantially influenced by the pounding. The investigated base-isolated building shows good resistance against shear failure and the predominant mode of failure due to pounding is flexural. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Existing design procedures for determining the separation distance between adjacent buildings subjected to seismic pounding risk are based on approximations of the buildings' peak relative displacement. These procedures are characterized by unknown safety levels and thus are not suitable for use within a performance‐based earthquake engineering framework. This paper introduces an innovative reliability‐based methodology for the design of the separation distance between adjacent buildings. The proposed methodology, which is naturally integrated into modern performance‐based design procedures, provides the value of the separation distance corresponding to a target probability of pounding during the design life of the buildings. It recasts the inverse reliability problem of the determination of the design separation distance as a zero‐finding problem and involves the use of analytical techniques in order to evaluate the statistics of the dynamic response of the buildings. Both uncertainty in the seismic intensity and record‐to‐record variability are taken into account. The proposed methodology is applied to several different buildings modeled as linear elastic single‐degree‐of‐freedom (SDOF) and multi‐degree‐of‐freedom (MDOF) systems, as well as SDOF nonlinear hysteretic systems. The design separation distances obtained are compared with the corresponding estimates that are based on several response combination rules suggested in the seismic design codes and in the literature. In contrast to current seismic code design procedures, the newly proposed methodology provides consistent safety levels for different building properties and different seismic hazard conditions. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
The seismic behavior of tall buildings can be greatly affected by non-linear soil-pile interaction during strong earthquakes. In this study a 20-storey building is examined as a typical structure supported on a pile foundation for different conditions: (1) rigid base, i.e. no deformation in the foundation: (2) linear soil-pile system; and (3) nonlinear soil-pile system. The effects of pile foundation displacements on the behavior of tall building are investigated, and compared with the behavior of buildings supported on shallow foundation. With a model of non-reflective boundary between the near field and far field, Novak’s method of soil-pile interaction is improved. The computation method for vibration of pile foundations and DYNAN computer program are introduced comprehensively. A series of dynamic experiments have been done on full-scale piles, including single pile and group, linear vibration and nonlinear vibration, to verify the validity of boundary zone model.  相似文献   

20.
Earthquake‐induced structural pounding frequently causes serious damage to buildings, particularly at the expansion joint (hereafter, EXPJ) between adjacent buildings. Because the EXPJ width in existing reinforced concrete buildings is usually very small, typically about 5 cm for school buildings in Japan, collision avoidance cannot be achieved by seismic retrofitting. This paper presents an experimental investigation into an effective method for reducing severe structural damage due to pounding at the EXPJ between narrowly separated buildings. The method involves inserting a shock‐absorbing material such as rubber into the EXPJ gap. The efficiency of the proposed method is evaluated by laboratory shaking tests using two model buildings. Furthermore, a lumped mass model is used to carry out a collision analysis in order to numerically investigate the influence of such a shock‐absorbing material. Both the numerical and experimental results confirm the effectiveness of the proposed approach. The validity of the proposed method is also demonstrated by numerical simulation of adjacent 10‐story steel buildings with an EXPJ width of 5 cm. The force, acceleration and velocity produced by earthquake‐induced structural pounding are found to be remarkably mitigated by inserting a soft shock‐absorbing material into the EXPJ gap. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号