首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper proposes bi‐directional coupled tuned mass dampers (BiCTMDs) for the seismic response control of two‐way asymmetric‐plan buildings subjected to bi‐directional ground motions. The proposed BiCTMD was developed from the three‐degree‐of‐freedom modal system, which represents the vibration mode of a two‐way asymmetric‐plan building. The performance of the proposed BiCTMD for the seismic response control of elastic two‐way asymmetric‐plan buildings was verified by investigating the reductions of the amplitudes of the associated frequency response functions. In addition, the investigation showed that the proposed BiCTMD is effective in reducing the seismic damage of inelastic asymmetric‐plan buildings. Therefore, the BiCTMD is an effective approach for the seismic response control of both elastic and inelastic two‐way asymmetric‐plan buildings. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
The critical parameters that influence the nonlinear seismic response of asymmetric‐plan buildings are identified by evaluating the effects of different asymmetries that may characterize the structure of a building as well as exploring the influence of the ground motion features. First, the main findings reported in the literature on both the linear and nonlinear dynamic response of asymmetric‐plan buildings are presented. The common findings and the conflicting conclusions reached in different investigations are pointed out. Then, the results of comprehensive nonlinear dynamic analyses performed for evaluating the seismic response of systems characterized by different strength and stiffness configurations, representative of a large class of asymmetric‐plan buildings, are reported. Findings from the study indicate that the building response changes when moving from the linear to the nonlinear range, so that the seismic behavior of asymmetric‐plan buildings, apart from the source of asymmetry, can be always classified as irregular. Additionally, it was observed that as the seismic demands cause amplification of system nonlinearity with increasing earthquake intensity, the maximum displacement demand in the different resisting elements tends to be reached with the same deformed configuration of the system. The resultant of the seismic forces producing such a maximum demand is located at the center of resistance and corresponds to the collapse mechanism of the system that provides the maximum lateral strength in the exciting direction of the seismic action. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
A study is presented of the influence of stiffness and strength eccentricities on the inelastic torsional response of buildings under the action of two simultaneous orthogonal horizontal ground motion components. Asymmetric buildings were obtained from their respective symmetric systems and were characterized by their stiffness and strength torsional eccentricities in both orthogonal directions. Based on the results of inelastic response of both building types (symmetric and asymmetric), the seismic reliability functions are determined for each system, and their forms of variation with different global system parameters are evaluated. Illustrative examples are presented about the use of this information for the formulation of seismic design criteria for in‐plan asymmetric multistory systems, in order to attain the same reliability levels implicit for symmetric systems designed in accordance with current seismic design codes. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
基于抑制升船结构顶部厂房地震鞭梢效应的目的,本文提出了升船结构顶部厂房屋盖MR智能隔震模糊控制的思想。文中,在建立屋盖智能隔震升船结构计算力学模型的基础上,建立了屋盖MR智能隔震系统对升船结构顶部厂房地震反应模糊控制的设计计算方法。文中并以中国某大坝巨型升船结构为背景,设计了屋盖MR智能隔震系统对升船结构顶部厂房地震反应模糊控制的控制系统。仿真分析和对MR阻尼器的参数研究表明,安装合适的屋盖MR智能隔震系统并采用模糊控制策略能有效地抑制具有不确定参数升船结构顶部厂房地震反应的鞭梢效应,且模糊控制器能保持较好的稳定性能。  相似文献   

5.
This paper proposes a semiactive control system to reduce the coupled lateral and torsional motions in asymmetric buildings subjected to horizontal seismic excitations. Magnetorheological (MR) dampers are applied as semiactive control devices and the control input determination is based on a clipped‐optimal control algorithm which uses absolute acceleration feedback. The performance of this method is studied experimentally using a 2‐story building model with an asymmetric stiffness distribution. An automated system identification methodology is implemented to develop a control‐oriented model which has the natural frequencies observed in the experimental system. The parameters for the MR damper model are identified using experimental data to develop an integrated model of the structure and MR dampers. To demonstrate the performance of this control system on the experimental structure, a shake table is used to reproduce an El Centro 1940 N–S earthquake as well as a random white noise excitation. The responses for the proposed control system are compared to those of passive control cases in which a constant voltage is applied to the MR damper. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

6.
Guo  Wei  Wu  Jun  Hu  Yao  Li  Yunsong  Yang  T. Y. 《地震工程与工程振动(英文版)》2019,18(2):433-446
Adding dampers is a commonly adopted seismic risk mitigation strategy for modern buildings, and the corresponding design procedure of dampers has been well established by the Chinese Building Code. Even though all types of dampers are designed by the same procedure, actual seismic performance of the building may differ from one to the others. In this study, a nine-story benchmark steel building is established, and three different and typical types of dampers are designed according to the Chinese Building Code to realize structural vibration control under strong earthquake excitation. The seismic response of the prototype building equipped with a viscoelastic damper, viscous damper and buckling-restrained brace(BRB) subjected to 10 earthquake records are calculated, and Incremental Dynamic Analysis(IDA) is performed to describe progressive damage of the structure under increasing earthquake intensity. In the perspective of fragility, it shows that the viscoelastic damper has the highest collapse margin ratio(CMR), and the viscous damper provides the best drift control. Both the BRB and viscoelastic dampers can effectively reduce the floor acceleration responses in the mid-rise building.  相似文献   

7.
不对称大底板多塔楼隔震结构的地震响应分析   总被引:1,自引:0,他引:1  
党育  杜永峰 《地震学刊》2012,(4):452-458
针对不对称大底板多塔楼隔震结构体系,通过建立地震响应的动力分析简化模型,推导出不对称大底板多塔楼隔震结构体系地震作用下的运动方程。对一实际的不对称大底板多塔楼隔震结构进行地震响应仿真分析,探讨塔楼质量偏心率和塔楼质量比对结构周期比、位移比和层剪力比的影响。结果显示,不对称大底板多塔楼隔震结构扭转角主要由隔震层产生;与不隔震结构相比,不对称大底板多塔楼隔震体系的扭转角减小,可取得较好的减震效果;塔楼与底板的位置分布和质量分布会影响体系的扭转效应和减震效果,应尽量使塔楼的质心与底板质心重合,塔楼质量分布均匀,以减小结构的扭转效应,提高减震效果。  相似文献   

8.
Even though a number of parameters have been proposed in the literature for measuring the capacity of earthquake ground motions to damage structures, most of them are not consistent with building damage observed during earthquakes. In this study, a parameter for measuring seismic damage capacity is proposed. It uses the energy dissipated by a structure in inelastic deformations and a structural overall drift, and it is evaluated for three typical ground motions recorded in severe earthquakes. By using this parameter, consistent results with building damage observed in these earthquakes are obtained, which indicate the importance of displacement control for minimizing seismic damage.  相似文献   

9.
Damage assessments after past earthquakes have frequently revealed that plan configuration irregular buildings have more severe damage due to excessive torsional responses and stress concentration than regular buildings. The plan configuration irregularities introduce major challenges in the seismic design of buildings. One such form of irregularity is the presence of re-entrant corners in the L-shaped buildings that causes stress concentration due to sudden changes in stiffness and torsional response amplification; hence causes early collapse. A constructive research into re-entrant corner and torsional irregularity problems is essentially needed greater than ever. Therefore, the focus of this study is to investigate structural seismic response demands for the class of L-shaped buildings through evaluating the plan configuration irregularity of re-entrant corners and lateral–torsion coupling effects on measured seismic response demands. The measured responses include story drift, inter-story drift, story shear force, overturning moment, torsion moment at the base and over building height, and torsional irregularity ratio. Three dimensional finite element model for nine stories symmetric buildings as reference model is developed. In addition, six L-shaped building models are formulated with gradual reduction in the plan of the reference building model. The results prove that building models with high irregularity are more vulnerable due to the stress concentration and lateral torsional coupling behavior than that with regular buildings. In addition, the related lateral shear forces in vertical resisting elements located on the periphery of the L-shaped buildings could be significantly increased in comparison with the corresponding values for a symmetric building.  相似文献   

10.
In the field of civil engineering, magnetorheological fluid (MRF) damper-based semi-active control systems have received considerable attention for use in protecting structures from natural hazards such as strong earthquakes and high winds. In this paper, the MRF damper-based semi-active control system is applied to a long-span spatially extended structure and its feasibility is discussed. Meanwhile, a _trust-region method based instantaneous optimal semi-active control algorithm (TIOC) is proposed to improve the performance of the semi-active control system in a multiple damper situation. The proposed TIOC describes the control process as a bounded constraint optimization problem, in which an optimal semi- active control force vector is solved by the trust-region method in every control step to minimize the structural responses. A numerical example of a railway station roof structure installed with MRF-04K dampers is presented. First, a modified Bouc- Wen model is utilized to describe the behavior of the selected MRF-04K damper. Then, two semi-active control systems, including the well-known clipped-optimal controller and the proposed TIOC controller, are considered. Based on the characteristics of the long-span spatially extended structure, the performance of the control system is evaluated under uniform earthquake excitation and travelling-wave excitation with different apparent velocities. The simulation results indicate that the MR fluid damper-based semi-active control systems have the potential to mitigate the responses of full-scale long-span spatially extended structures under earthquake hazards. The superiority of the proposed TIOC controller is demonstrated by comparing its control effectiveness with the clipped-optimal controller for several different cases.  相似文献   

11.
This paper presents an experimental investigation on semi-active seismic response control of a multistory building with a podium structure using multiple magnetorheological (MR) dampers manipulated by a logic control algorithm. The experiments are performed in three phases on a seismic simulator with a slender 12-story building model representing a multi-story building and a relatively stiff 3-story building model typifying a podium structure. The first phase of the investigation is to assess control performance of using three MR dampers to link the 3-story building to the 12-story building, in which seismic responses of the controlled two buildings are compared with those of the two buildings without any connection and with rigid connection. The second phase is to investigate reliability of the semi-active control system and robustness of the logic control algorithm when 2 out of 3 MR dampers fail and when the electricity supply to MR dampers is completely stopped. The last phase is to examine sensitivity of semi-active control performance of two buildings to change in ground excitation. The experimental results show that multiple MR dampers with the logic control algorithm can achieve a significant reduction in seismic responses of both buildings. The proposed semi-active control system is of high reliability and good robustness.  相似文献   

12.
This study explores seismic performance of steel frame buildings with SMA-based self-centering bracing systems using a probabilistic approach. The self-centering bracing system described in this study relies on superelastic response of large-diameter cables. The bracing systems is designed such that the SMA cables are always stressed in tension. A four-story steel frame building characterized until collapse in previous research is selected as a case-study building. The selected steel frame building is designed with SMA bracing systems considering various design parameters for SMA braces. Numerical models of these buildings are developed by taking into account the ultimate state of structural components and SMA braces as well as the effect of gravity frames on lateral load resistance. Nonlinear static analyses are conducted to assess the seismic characteristics of each frame and to examine the effect of SMA brace failure on the seismic load carrying capacity of SMA-braced frames. Incremental dynamic analyses (IDA) are performed to compute seismic response of the designed frames at various seismic intensity levels. The results of IDA are used to develop probabilistic seismic demand models for peak inter-story and residual inter-story drifts. Seismic demand hazard curves of peak and residual inter-story drifts are generated by convolving the ground motion hazard with the probabilistic seismic demand models. Results show that steel frames designed with SMA bracing systems provide considerably lower probability of reaching at a damage state level associated with residual drifts compared to a similarly designed steel moment resisting frame, especially for seismic events with high return periods. This indicates reduced risks for the demolition and collapse due to excessive residual drifts for SMA braced steel frames.  相似文献   

13.
In past years, seismic response of asymmetric structures has been frequently analysed by means of single-storey models, because of their simplicity and low computational cost. However, it is widely believed that use of more realistic multi-storey models is needed in order to investigate effects of some system characteristics (such as overstrength, higher modes of vibration, etc.) that make behaviour of multi-storey schemes different from that of single-storey systems. This paper examines effects of the overstrength in element cross-sections on the seismic behaviour of multi-storey asymmetric buildings. It is shown that in actual buildings this characteristic, which is sometimes very variable both in plan and along the height of the building, may lead to distributions of ductility demands different from those expected according to the results from single-storey models. Consequently, torsional provisions, which aim at reducing ductility demands of single-storey asymmetric systems to those of the corresponding torsionally balanced systems, should be re-checked in light of the behaviour of realistic multi-storey buildings.  相似文献   

14.
This investigation is concerned with the seismic response of one‐story, one‐way asymmetric linear and non‐linear systems with non‐linear fluid viscous dampers. The seismic responses are computed for a suite of 20 ground motions developed for the SAC studies and the median values examined. Reviewed first is the behaviour of single‐degree‐of‐freedom systems to harmonic and earthquake loading. The presented results for harmonic loading are used to explain a few peculiar trends—such as reduction in deformation and increase in damper force of short‐period systems with increasing damper non‐linearity—for earthquake loading. Subsequently, the seismic responses of linear and non‐linear asymmetric‐plan systems with non‐linear dampers are compared with those having equivalent linear dampers. The presented results are used to investigate the effects of damper non‐linearity and its influence on the effects of plan asymmetry. Finally, the design implications of the presented results are discussed. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

15.
Passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are proposed to mitigate structural response due to seismic loads. The structure's upper portion self plays a role either as a tuned mass passive damper or a semi‐active resetable device is adopted as a control feature for the PTMD, creating a SATMD system. Two‐degree‐of‐freedom analytical studies are employed to design the prototype structural system, specify its element characteristics and effectiveness for seismic responses, including defining the resetable device dynamics. The optimal parameters are derived for the large mass ratio by numerical analysis. For the SATMD building system the stiffness of the resetable device design is combined with rubber bearing stiffness. From parametric studies, effective practical control schemes can be derived for the SATMD system. To verify the principal efficacy of the conceptual system, the controlled system response is compared with the response spectrum of the earthquake suites used. The control ability of the SATMD scheme is compared with that of an uncontrolled (No TMD) and an ideal PTMD building systems for multi‐level seismic intensity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A series of large‐scale real‐time hybrid simulations (RTHSs) are conducted on a 0.6‐scale 3‐story steel frame building with magneto‐rheological (MR) dampers. The lateral force resisting system of the prototype building for the study consists of moment resisting frames and damped brace frames (DBFs). The experimental substructure for the RTHS is the DBF with the MR dampers, whereas the remaining structural components of the building including the moment resisting frame and gravity frames are modeled via a nonlinear analytical substructure. Performing RTHS with an experimental substructure that consists of the complete DBF enables the effects of member and connection component deformations on system and damper performance to be accurately accounted for. Data from these tests enable numerical simulation models to be calibrated, provide an understanding and validation of the in‐situ performance of MR dampers, and a means of experimentally validating performance‐based seismic design procedures for real structures. The details of the RTHS procedure are given, including the test setup, the integration algorithm, and actuator control. The results from a series of RTHS are presented that includes actuator control, damper behavior, and the structural response for different MR control laws. The use of the MR dampers is experimentally demonstrated to reduce the response of the structure to strong ground motions. Comparisons of the RTHS results are made with numerical simulations. Based on the results of the study, it is concluded that RTHS can be conducted on realistic structural systems with dampers to enable advancements in resilient earthquake resistant design to be achieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
Uneven distribution of seismic demand in asymmetric-plan structures is a critical concern in earthquake-resistant design. Contemporary seismic design strategies that are based on linear elastic response, single load reduction factor, and uniform ductility demand throughout an asymmetric system generally lead to unsatisfactory performance in terms of realized ductilities and nonuniform damage distribution due to strong torsional coupling associated with asymmetric-plan systems. In many cases, actual nonlinear behavior of the structure displays significant deviation from what is estimated by a linear elastic, force-based seismic design approach. This study investigates the prediction of seismic demand distribution among structural members of a single-story, torsionally stiff asymmetric-plan system. The focus is on the effect of inherent unbalanced overstrength, resulting from current force-based design practices, on the seismic response of code-designed single-story asymmetric structures. The results obtained are utilized to compile unsymmetrical response spectra and uniform ductility spectra, which are proposed as assessment and preliminary design tools for estimating the seismic performance of multistory asymmetric structures. A simple design strategy is further suggested for improving the inelastic torsional performance of asymmetric systems. Providing additional strength to stiff edge members over their nominal design strength demands leads to a more balanced ductility distribution. Finally, seismic responses of several asymmetric case study structures designed with the aid of the proposed strategy are assessed for validating their improved performance.  相似文献   

18.
本文建立了用ER/MR智能阻尼器耦联的带裙房高层建筑结构地震反应半主动控制的设计计算方法,文中,在导出ER/MR智能阻尼器力学模型的基础上,建立了ER/MR智能阻尼器耦联的带裙房层建筑结构地震反应的基本方程,并根据瞬时最优主动控制的原则,提出了ER/MR智能阻尼器耦联的带裙房高层建筑地震反应半主动控制的基于最优主动控制位移的“开关-耗能”半主动控制策略,应用本文方法对主楼20层,裙房5层的计算结构;受控地震反应的模拟计算结构表明,耦联主楼和裙房的半主动的ER/MR智能阻尼器可有效地抑制带裙房高层建筑结构地震反应的鞭梢效应,并可均匀地减小结构各层的震反应,是一种简单,方便和有效的智能控制装置。  相似文献   

19.
Several parameters have been proposed in the literature for the evaluation of seismic damage. However, in most cases the correlation between results obtained using these parameters and observed damage in structures has not been satisfactory. A parameter for measuring seismic damage previously proposed by the first author is used in this study to analyse a set of 15 accelerograms recorded in 11 earthquakes experienced in different countries. Results using this parameter are compared to global building damage observed during these earthquakes. The use of the parameter proposed here yields results which are consistent with building damage observed in the earthquakes studied. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

20.
An approximation approach of seismic analysis of two‐way asymmetric building systems under bi‐directional seismic ground motions is proposed. The procedures of uncoupled modal response history analysis (UMRHA) are extended to two‐way asymmetric buildings simultaneously excited by two horizontal components of ground motion. Constructing the relationships of two‐way base shears versus two‐way roof translations and base torque versus roof rotation in ADRS format for a two‐way asymmetric building, each modal pushover curve bifurcates into three curves in an inelastic state. A three‐degree‐of‐freedom (3DOF) modal stick is developed to simulate the modal pushover curve with the stated bifurcating characteristic. It requires the calculation of the synthetic earthquake and angle β. It is confirmed that the 3DOF modal stick is consistent with single‐degree‐of‐freedom modal stick in an elastic state. A two‐way asymmetric three‐story building was analyzed by UMRHA procedure incorporating the proposed 3DOF modal sticks. The analytical results are compared with those obtained from nonlinear response history analysis. It is shown that the 3DOF modal sticks are more rational and effective in dealing with the assessment of two‐way asymmetric building systems under two‐directional seismic ground motions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   