首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The energy dissipation characteristics of reinforced concrete members that exhibit both strength and stiffness deterioration under imposed displacement reversals were investigated. To do this, 24 symmetrically reinforced concrete rectangular specimens were tested under stable variable and random variable amplitude inelastic displacement cycles. Stable variable amplitude tests were employed to determine the low‐cycle fatigue behavior of specimens where the loading sequence was the major variable. A 2‐parameter fatigue model was developed in order to express the variation of the dissipated energy in displacement cycles with the cumulative hysteretic energy. This model was then used to predict the energy dissipation of test specimens subjected to random variable amplitude displacement cycles simulating severe seismic excitations. It has been demonstrated that the remaining energy dissipation capacity for the next displacement cycle was dependent on the relative relationship between the maximal displacement cycle and the energy dissipated along the completed displacement path. The plastic energy dissipation capacity of reinforced concrete members is both displacement path dependent and cumulative hysteretic energy dependent.  相似文献   

2.
Energy dissipation characteristics of structural members which exhibit both strength and stiffness deterioration under imposed displacement reversals are investigated. In the experimental part, 17 reinforced concrete beam specimens were tested under constant and variable amplitude inelastic displacement cycles. The constant‐amplitude tests were employed to determine the low‐cycle fatigue behaviour of specimens where the imposed displacement amplitude was the major variable. A two‐parameter fatigue model was developed in order to express the variation of dissipated energy with the number of displacement cycles. This model was then used to predict the energy dissipation of test specimens subjected to variable‐amplitude displacement cycles simulating severe seismic excitations. It has been demonstrated that the remaining energy dissipation capacity in a forthcoming displacement cycle is dependent on the energy dissipated along the completed displacement path. Moreover, it is observed that total energy dissipation is dependent on the length of the displacement path. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
This paper proposes a new model for quantifying the damage in structural steel components subjected to randomly applied flexural/shear stress reversals, such those induced by earthquakes. In contrast to existing approaches that consider the damage as a combination of the global amount of dissipated energy and maximum displacement, the proposed model represents the damage by two parameters: (a) the total dissipated energy and (b) the portion of the energy consumed in the skeleton part of the load–displacement curve. These parameters are employed to define a single ‘damage index’, which measures the level between 0 (no damage) and 1 (failure). The proposed model takes into account that the ultimate energy dissipation capacity of the steel component is path‐dependent and can change throughout the entire response duration. The new model is derived from low‐cycle fatigue static tests of round steel rods and steel plates subjected to bending and shear. The accuracy of the model is verified experimentally through dynamic real‐time shaking table tests. From these tests, it is observed that the proposed model measures the level of damage at any stage of the loading process reasonably well and predicts the failure of the structural component accurately. The model can be easily implemented in a computer program to assess the level of seismic damage and the closeness to failure in new structures or to evaluate the safety of existing ones. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
为研究远场长周期地震动作用下SRC柱的抗震性能,对5个不同含钢率和配箍率的SRC柱进行同级位移循环加载10次的拟静力试验,分析其抗震性能指标。结果表明:同级位移循环次数对SRC柱抗震性能的影响与循环位移幅值有关。位移角不大于1/50时,同级位移循环次数对SRC柱的裂缝发展、承载力退化和耗能能力的影响均很小;位移角1/40时,随着位移循环次数的增加,SRC柱的裂缝不断发展,角部混凝土逐渐掉落,承载力退化幅度开始加大,耗能能力逐渐增强,损伤程度增长较快;位移角1/33时,同级位移多次循环导致SRC柱的损伤急剧发展,承载力快速降低,耗能能力明显增强,破坏程度显著加重。提高含钢率和配箍率均可以改善SRC柱的抗震性能。  相似文献   

5.
Widely used damage indices, such as ductility and drift ratios, do not account for the influences of the duration of strong shaking, the cumulative inelastic deformation or energy dissipation in structures. In addition, the formulation and application of most damage indices have until now been based primarily on flexural modes of failure. However, evidence from earthquakes suggests that shear failure or combined shear‐flexure behavior is responsible for a large proportion of failures. Empirical considerations have been made in this paper for evaluating structural damage of low‐rise RC walls under earthquake ground motions by means of a new energy‐based low‐cycle fatigue damage index. The proposed empirical damage index is based on the results of an experimental program that comprised six shake table tests of RC solid walls and walls with openings; results of six companion walls tested under QS‐cyclic loading were used for comparison purposes. Variables studied were the wall geometry, type of concrete, web shear steel ratio, type of web shear reinforcement, and testing method. The index correlates the stiffness degradation and the destructiveness of the earthquake in terms of the duration and intensity of the ground motions. The stiffness degradation model considers simultaneously the increment of damage associated to the low‐cycle fatigue, energy dissipation, and the cumulative cyclic parameters, such as displacement demand and hysteretic energy dissipated. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
The paper presents a hysteretic damage model for the response simulation of structural components with strength and stiffness deterioration under cyclic loading. The model is based on 1D continuum damage mechanics and relates any 2 work‐conjugate response variables such as force‐displacement, moment‐rotation, or stress‐strain. The strength and stiffness deterioration is described by a continuous damage variable. The formulation uses a criterion based on the hysteretic energy and the maximum or minimum deformation for damage initiation with a cumulative probability distribution function for the damage evolution. A series of structural component response simulations showcase the ability of the model to describe different types of hysteretic behavior. The relation of the model's damage variable to the Park‐Ang damage index is also discussed. Because of its consistent and numerically robust formulation, the model is suitable for the large‐scale seismic response simulation of structural systems with strength and stiffness deterioration.  相似文献   

7.
A probabilistic approach to lifetime assessment of seismic resilience of deteriorating concrete structures is presented. The effects of environmental damage on the seismic performance are evaluated by means of a methodology for lifetime assessment of concrete structures in aggressive environment under uncertainty. The time‐variant seismic capacity associated with different limit states, from damage limitation up to collapse, is assumed as functionality indicator. The role of the deterioration process on seismic resilience is then investigated over the structural lifetime by evaluating the post‐event residual functionality and recovery of the deteriorating system as a function of the time of occurrence of the seismic event. The proposed approach is applied to a three‐story concrete frame building and a four‐span continuous concrete bridge under corrosion. The results show the combined effects of structural deterioration and seismic damage on the time‐variant system functionality and resilience and indicate the importance of a multi‐hazard life‐cycle‐oriented approach to seismic design of resilient structure and infrastructure systems. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
Seismic performance of structures is related to the damage inflicted on the structure by the earthquake, which means that formulation of performance‐based design is inherently coupled with damage assessment of the structure. Although the potential for cumulative damage during a long‐duration earthquake is generally recognized, most design codes do not explicitly take into account the damage potential of such events. In this paper, the classical low‐cycle fatigue model commonly used for seismic damage assessment is cast in a framework suitable for incorporating cumulative damage into seismic design. The model, in conjunction with a seismic input energy spectrum, may be used to establish an energy‐based seismic design. In order to ensure satisfactory performance in a structure, the cyclic plastic strain energy capacity of the structure is designed to be larger than or equal to the portion of seismic input energy contributing to cumulative damage. The resulting design spectrum, which depends on the duration of the ground motion, indicates that the lateral strength of the structure must be increased in order to compensate for the increased damage due to an increased number of inelastic cycles that occur in a long‐duration ground motion. Examples of duration‐dependent inelastic design spectra are developed using parameters currently available for the low‐cycle fatigue model. The resulting spectra are also compared with spectra developed using a different cumulative damage model. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

9.
This paper investigates the non-linear seismic behavior of structures such as slender unreinforced masonry shear walls or precast post-tensioned reinforced concrete elements, which have little hysteretic energy dissipation capacity. Even if this type of seismic response may be associated with significant deformation capacity, it is usually not considered as an efficient mechanism to withstand strong earthquakes. The objective of the investigations is to propose values of strength reduction factors for seismic analysis of such structures. The first part of the study is focused on non-linear single-degree-of-freedom (SDOF) systems. A parametric study is performed by computing the displacement ductility demand of non-linear SDOF systems for a set of 164 recorded ground motions selected from the European Strong Motion Database. The parameters investigated are the natural frequency, the strength reduction factor, the post-yield stiffness ratio, the hysteretic energy dissipation capacity and the hysteretic behavior model (four different hysteretic models: bilinear self-centring, with limited or without energy dissipation capacity, modified Takeda and Elastoplastic). Results confirm that the natural frequency has little influence on the displacement ductility demand if it is below a frequency limit and vice versa. The frequency limit is found to be around 2 Hz for all hysteretic models. Moreover, they show that the other parameters, especially the hysteretic behavior model, have little influence on the displacement ductility demand. New relationships between the displacement ductility demand and the strength reduction factor for structures having little hysteretic energy dissipation capacity are proposed. These relationships are an improvement of the equal displacement rule for the considered hysteretic models. In the second part of the investigation, the parametric study is extended to multi-degree-of-freedom (MDOF) systems. The investigation shows that the results obtained for SDOF systems are also valid for MDOF systems. However, the SDOF system overestimates the displacement ductility demand in comparison to the corresponding MDOF system by approximately 15%.  相似文献   

10.
本文提出了一种新型舌板黏滞阻尼器,通过对该黏滞阻尼器进行低周循环加载试验和抗低周疲劳性能试验,研究并验证了该阻尼器的耗能性能、抗低周疲劳性能及恢复力模型。研究结果表明:选取合适参数的舌板式黏滞阻尼器滞回曲线饱满,耗能性能与抗低周疲劳性能良好。Maxwell模型能够较好地描述该阻尼器力学行为,反映阻尼器在各种试验工况下的出力情况。该阻尼器设计与加工简单,对工程结构的耗能减震有着实际意义。  相似文献   

11.
Cable‐stayed bridges require a careful consideration of the lateral force exerted by the deck on the towers under strong earthquakes. This work explores the seismic response of cable‐stayed bridges with yielding metallic dampers composed of triangular plates that connect the deck with the supports in the transverse direction. A design method based on an equivalent single‐degree of freedom approximation is proposed. This is proved valid for conventional cable‐stayed bridges with 200‐ and 400‐m main spans, but not 600 m. The height of the plates is chosen to (1) achieve a yielding capacity that limits the maximum force transmitted from the deck to the towers, and to (2) control the hysteretic energy that the dampers dissipate by defining their design ductility. In order to select the optimal ductility and the damper configuration, a multi‐objective response factor that accounts for the energy dissipation, peak damper displacement and low‐cycle fatigue is introduced. The design method is applied to cable‐stayed bridges with different spans and deck–support connections. The results show that the dissipation by plastic deformation in the dampers prevents significant damage in the towers of the short‐to‐medium‐span bridges under the extreme seismic actions. However, the transverse response of the towers in the bridge with a 600‐m main span is less sensitive to the dampers. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

12.
It is not common to purposely subject the web of wide‐flange or I‐sections to out‐of‐plane bending. However, yielding the web under this loading condition can be a stable source of energy dissipation as the transition at the corner from the web to the flanges is smooth and weld‐free; this prevents stress concentrations causing premature failure and eliminates uncertainties and imperfections associated with welding. Further, short segments of wide‐flange or I‐sections constitute a simple and inexpensive energy dissipating device as minimum manufacturing is required and leftovers not useful for other structural purposes can be re‐utilized. This paper proposes a new type of seismic damper in the form of braces based on yielding the web of short length segments of wide‐flange or I‐shaped steel sections under out‐of‐plane bending. The hysteretic behavior and ultimate energy dissipation capacity is investigated via component tests under cyclic loads. The experimental results indicate that the damping device has stable restoring force characteristics and a high energy dissipation capacity. Based on these results, a simple hysteretic model for predicting the load–displacement curve of the seismic damper is proposed, along with a procedure for predicting its ultimate energy dissipation capacity and anticipating its failure under arbitrarily applied cyclic loads. The procedure considers the influence of the loading path on the ultimate energy dissipation capacity. Finally, shaking table tests on half‐scale structures are conducted to further verify the feasibility and effectiveness of the new damper, and to assess the accuracy of the hysteretic model and the procedure for predicting its failure. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
In order to enhance the durability of high‐performance buckling‐restrained braces (BRBs) used in bridge engineering, which are expected to withstand severe earthquakes three times without being replaced, aluminum alloys were employed to manufacture BRBs. A series of low‐cycle fatigue tests, including 18 specimens, were conducted to address the low‐cycle fatigue strength of the aluminum alloy BRB. Test results of all specimens show that stable hysteretic curves were obtained without overall buckling occurrence. Failure mode of the welded aluminum alloy BRB is obviously affected by the ribs' welding under the variable or constant strain amplitude condition. Therefore, another type of aluminum alloy BRB, the bolt‐assembled BRB with or without spot‐welded stoppers, is proposed and tested. Results showed that the low‐cycle fatigue performance of bolt‐assembled BRBs with stoppers improved four to five times compared with welded BRBs. However, the stoppers' spot welding has an adverse effect on the failure mode because the crack, which induced the specimen's failure, initiated from the spot weld toes of the stoppers. Both bolt‐assembled BRBs with and without stoppers can meet the cumulative inelastic deformation requirement proposed for high‐performance BRBs under the constant strain amplitude, not larger than 2%. In addition, under the variable strain amplitude condition, only the bolt‐assembled BRB without stoppers has an excellent cumulative inelastic deformation capacity and sustains two cycles of 2.5% strain amplitude. Finally, recommended Manson–Coffin equations and preliminary cumulative damage formulae for welded and bolt‐assembled BRBs are given as the references of the strain‐based damage evaluation. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
The reinforced concrete (RC) shear wall serves as one of the most important components sustaining lateral seismic forces. Although they allow advanced seismic performance to be achieved, RC shear walls are rather difficult to repair once the physical plastic hinge at the bottom part has been formed. To overcome this, a damage‐controllable plastic hinge with a large energy dissipation capacity is developed herein, in which the sectional forces are decoupled and sustained separately by different components. The components sustaining the axial and the shear forces all remain elastic even under a rarely occurred earthquake, while the bending components yield and dissipate seismic energy during a design‐level earthquake. This design makes the behavior of the system more predictable and thus more easily customizable to different performance demands. Moreover, the energy dissipation components can be conveniently replaced to fully restore the occupancy function of a building. To examine the seismic behavior of the newly developed component, 3 one third‐scale specimens were tested quasi‐statically, including 1 RC wall complying with the current design codes of China and 2 installed with the damage‐controllable plastic hinges. Each wall was designed to have the same strength. The experimental results demonstrated that the plastic‐hinge‐supported walls had a better energy dissipation capacity and damage controllability than the RC specimen. Both achieved drift ratios greater than 3% under a steadily increasing lateral force.  相似文献   

15.
The seismic response spectrum defines the amplitude of the load, but it does not specify the number of cycles for which the load must be resisted by the structure. The amplitude by itself is not sufficient to evaluate the seismic resistance of a structure, because the structure's strength, stiffness and energy‐dissipation capacity reduce with an increase in the number of load cycles. This paper presents a cyclic‐demand spectrum, which, in conjunction with the amplitude spectrum, provides a more complete definition of the seismic load, hence a way to consider the degradation in strength, stiffness and energy‐dissipation capacity in a rational manner. Similarly to three amplitude parameters (peak ground acceleration, peak ground velocity, and peak ground displacement), three cyclic‐demand parameters are introduced for stiff, moderately stiff, and flexible systems. A design example is presented to illustrate the use of the cyclic‐demand spectrum. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

16.
通过14根铰支焊接工字形支撑在不同特征的循环轴向位移荷载下的低周疲劳试验,研究了循环轴向位移荷载的位移幅值、平均位移幅值及加载次序等因素对钢支撑低周疲劳及耗能性能的影响。研究发现,对称循环荷载中幅值越小,支撑翼缘局部屈曲发展越晚,其耗能及承载力退化也越平缓。文中提出了支撑在幅值6δ≤Δδ≤12δy的对称循环荷载下的疲劳寿命经验公式。试验表明,循环荷载的位移幅值是支撑疲劳损伤及耗能退化的最主要影响因素,过载峰效应及适当的平均压位移幅值改善了钢支撑低周疲劳及耗能性能。  相似文献   

17.
Ductile‐jointed connections, which generally require some form of supplementary energy dissipation to alleviate displacement response, typically employ mild steel energy dissipation devices. These devices run the risk of low‐cycle fatigue, are effective only for peak cycles that exceed prior displacements, are prone to buckling, and may require replacement following an earthquake. This study presents an experimental investigation employing an alternative to mild steel: a high force‐to‐volume (HF2V) class of damper‐based energy dissipation devices. Tests are performed on a near full‐scale beam–column joint subassembly utilizing externally mounted compact HF2V devices. Two configurations are considered: an exterior joint with two seismic beams and one gravity beam framing into a central column, and a corner joint with only one seismic beam and one gravity beam framing into a column. Quasi‐static tests are performed to column drifts up to 4%. The experiments validate the efficacy of the HF2V device concept, demonstrating good hysteretic energy dissipation, and minimal residual device force, allowing ready re‐centring of the joint. The devices dissipate energy consistently on every cycle without the deterioration observed in the yielding steel bar type of devices. The effectiveness of the HF2V devices on structural hysteretic behavior is noted to be sensitive to the relative stiffness of the anchoring elements, indicating that better efficiency would be obtained in an embedded design. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
为研究附设黏滞阻尼器的传统风格建筑混凝土梁-柱节点地震损伤演化规律,进行6个该类型构件的动力荷载试验,并分别采用位移型、能量型及位移-能量混合型损伤模型对其进行全过程评价,采用Park-Ang模型分析试件黏滞阻尼器型号、试件类型等因素对混凝土传统风格建筑梁柱节点损伤行为的影响。研究结果表明:附设黏滞阻尼器可显著提升传统风格建筑节点的承载能力、延性性能及耗能能力,结构的抗震性能得到较大幅度的提升;Park-Ang损伤模型与Banon损伤模型适用于传统风格建筑节点损伤演化规律的描述,建议对该类型节点的损伤规律表征选用该损伤模型。黏滞阻尼器型号可在一定程度上影响传统风格建筑的损伤演化发展;设计阻尼力大的试件虽然延性有所提高,但受荷过程中累积损伤也较大。  相似文献   

19.
The study investigated the cyclic behavior of unbonded, post‐tensioned, precast concrete‐filled tube segmental bridge columns by loading each specimen twice. Moreover, a stiffness‐degrading flag‐shaped (SDFS) hysteretic model was developed based on self‐centering and stiffness‐degrading behaviors. The proposed model overcomes the deficiency of cyclic behavior prediction using a FS model, which self‐centers with fixed elastic and inelastic stiffnesses. Experimental and analytical results showed that (1) deformation capabilities of the column under the first and second cyclic tests were similar; however, energy dissipation capacities significantly differed from each other, and (2) the SDFS model predicted the cyclic response of the column better than the FS model. Inelastic time‐history analyses were performed to demonstrate the dynamic response variability of a single‐degree‐of‐freedom (SDOF) system using both models. A parametric study, performed on SDOF systems subjected to eight historical earthquakes, showed that increased displacement ductility demand was significant for structures with a low period and low‐to‐medium yield strength ratio and reduced displacement ductility demand in these systems was effectively attained by increasing energy dissipation capacity. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
王尧鸿    晁磊  杨晓明    李志强  秦颖 《世界地震工程》2022,38(4):113-119
为研究橡胶集料风积沙混凝土柱的抗震性能,制作了4根相同尺寸的混凝土柱试件,其中包括普通混凝土柱、风积沙混凝土柱、橡胶集料混凝土柱和橡胶集料风积沙混凝土柱。通过低周反复荷载试验,分析各试件的破坏现象、滞回曲线、骨架曲线、刚度退化和延性等抗震性能指标。在试验的基础上,根据能量耗散原理建立累积损伤评价模型,并对结构进行了累积损伤分析。研究结果表明:10%橡胶集料的掺入能够改善混凝土柱的变形能力,但混凝土柱的承载力有所降低;30%风积沙的掺入可以改善混凝土柱的抗震性能;橡胶集料风积沙混凝土柱具有较好的滞回性能,且耗能能力和延性性能明显高于其余试件,柱的抗震性能得到提高;通过累积损伤分析表明:适量掺入橡胶集料和风积沙的可以有效减缓试件的损伤,且该累积损伤模型能够较好的反映出各试件的损伤程度。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏