首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 321 毫秒
1.
A semi‐active fuzzy control strategy for seismic response reduction using a magnetorheological (MR) damper is presented. When a control method based on fuzzy set theory for a structure with a MR damper is used for vibration reduction of a structure, it has an inherent robustness, and easiness to treat the uncertainties of input data from the ground motion and structural vibration sensors, and the ability to handle the non‐linear behavior of the structure because there is no longer the need for an exact mathematical model of the structure. For a clipped‐optimal control algorithm, the command voltage of a MR damper is set at either zero or the maximum level. However, a semi‐active fuzzy control system has benefit to produce the required voltage to be input to the damper so that a desirable damper force can be produced and thus decrease the control force to reduce the structural response. Moreover, the proposed control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. The results of the numerical simulations show that the proposed semi‐active control system consisting of a fuzzy controller and a MR damper can be beneficial in reducing seismic responses of structures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

2.
This research investigates the development of a semi‐active piezoelectric friction damper for controlling the seismic response of large‐scale structures. The proposed device is made of Duplex steel and leads to high friction capacity, which can be developed either in passive or semi‐active modes. For the later, piezoelectric actuators react against a stiff clamping system and apply a variable normal force on the multiple contact surfaces. To validate the design, a prototype, which contact surfaces were made of stainless steel and brake pad material, was built and tested in both friction modes. Moreover, an analytical model of the damper was developed to estimate the performance of the piezoelectric actuators within the clamping system. Experimental results showed that the proposed device achieves a force range factor of 1.9. These experimental results also compare well with those obtained from the analytical model of the damper. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Semi‐active control of buildings and structures for earthquake hazard mitigation represents a relatively new research area. Two optimal displacement control strategies for semi‐active control of seismic response of frame structures using magnetorheological (MR) dampers or electrorheological (ER) dampers are proposed in this study. The efficacy of these displacement control strategies is compared with the optimal force control strategy. The stiffness of brace system supporting the smart damper is also taken into consideration. An extensive parameter study is carried out to find the optimal parameters of MR or ER fluids, by which the maximum reduction of seismic response may be achieved, and to assess the effects of earthquake intensity and brace stiffness on damper performance. The work on example buildings showed that the installation of the smart dampers with proper parameters and proper control strategy could significantly reduce seismic responses of structures, and the performance of the smart damper is better than that of the common brace or the passive devices. The optimal parameters of the damper and the proper control strategy could be identified through a parameter study. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

4.
Sliding base‐isolation systems used in bridges reduce pier drifts, but at the expense of increased bearing displacements under near‐source pulse‐type earthquakes. It is common practice to incorporate supplemental passive non‐linear dampers into the isolation system to counter increased bearing displacements. Non‐linear passive dampers can certainly reduce bearing displacements, but only with increased isolation level forces and pier drifts. The semi‐active controllable non‐linear dampers, which can vary damping in real time, can reduce bearing displacements without further increase in forces and pier drifts; and hence deserve investigation. In this study performance of such a ‘smart’ sliding isolation system, used in a 1:20 scaled bridge model, employing semi‐active controllable magneto‐rheological (MR) dampers is investigated, analytically and experimentally, under several near‐fault earthquakes. A non‐linear analytical model, which incorporates the non‐linearities of sliding bearings and the MR damper, is developed. A Lyapunov control algorithm for control of the MR damper is developed and implemented in shake table tests. Analytical and shake table test results are compared. It is shown that the smart MR damper reduces bearing displacements further than the passive low‐ and high‐damping cases, while maintaining isolation level forces less than the passive high‐damping case. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
This paper proposes a hybrid control strategy combining passive and semi‐active control systems for seismic protection of cable‐stayed bridges. The efficacy of this control strategy is verified by examining the ASCE first‐generation benchmark problem for a seismically excited cable‐stayed bridge, which employs a three‐dimensional linearized evaluation bridge model as a testbed structure. Herein, conventional lead–rubber bearings are introduced as base isolation devices, and semi‐active dampers (e.g., variable orifice damper, controllable fluid damper, etc.) are considered as supplemental damping devices. For the semi‐active dampers, a clipped‐optimal control algorithm, shown to perform well in previous studies involving controllable dampers, is considered. Because the semi‐active damper is a controllable energy‐dissipation device that cannot add mechanical energy to the structural system, the proposed hybrid control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. Numerical simulation results show that the performance of the proposed hybrid control strategy is quite effective in protecting seismically excited cable‐stayed bridges. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

6.
This study uses a semi‐active viscous damper with three different control laws to reshape the structural hysteresis loop and mitigate structural response, referred to as 1–4, 1–3 and 2–4 devices, respectively. The 1–4 control law provides damping in all four quadrants of the force‐displacement graph (it behaves like a standard viscous damper), the 1–3 control law provides resisting forces only in the first and third quadrants, and the 2–4 control law provides damping in the second and fourth quadrants. This paper first outlines the linear single degree of freedom structural performance when the three types of semi‐active viscous dampers are applied. The results show that simultaneous reduction in both displacement and base‐shear demand is only available with the semi‐active 2–4 device. To enable guidelines for adding a 2–4 device into the design procedure, damping reduction factors (RFξs) are developed, as they play an important role and provide a means of linking devices to design procedures. Three methods are presented to obtain RFξ and equivalent viscous damping of a structure with a 2–4 semi‐active viscous damper. In the first method, the relationship between RFξ and the damping of a semi‐active structure can be obtained by calculating the area under the force‐deformation diagram. The second and third method modified the Eurocode8 formula of RFξ and smoothed results from analysis, respectively. Finally, a simple method is proposed to incorporate the design or retrofit of structures with simple, robust and reliable 2–4 semi‐active viscous dampers using standard design approaches. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
摩擦阻尼器是一种构造简单的耗能减振装置,已应用于国内外多座新建建筑的抗震设计和已建建筑的抗震加固.半主动磨擦阻尼器则通过调整阻尼器的起滑力来改善被动摩擦阻尼器的耗能减振性能。本文研究了被动及半主动摩擦阻尼器对于高耸塔架结构地震反应的减振效果。为满足摩擦阻尼器对高耸塔架结构风振控制的特殊需要,本文建立了合肥电视塔的空间桁架有限元模型和串联多自由度体系模型,并在形成控制力变换矩阵和计算摩擦阻尼器两端的相对位移的过程中综合地运用了这两种力学模型。在半主动摩擦阻尼器的控制策略方面,本文提出了一种基于次优控制理论的半主动控制策略.本文研究表明,摩擦阻尼器可以抑制高耸塔架结构的地震反应.而半主动摩擦阻尼辞的耗能减振效果明显优于被动摩擦阻尼器.  相似文献   

8.
Critical non‐structural equipments, including life‐saving equipment in hospitals, circuit breakers, computers, high technology instrumentations, etc., are vulnerable to strong earthquakes, and the failure of these equipments may result in a heavy economic loss. In this connection, innovative control systems and strategies are needed for their seismic protections. This paper presents the performance evaluation of passive and semi‐active control in the equipment isolation system for earthquake protection. Through shaking table tests of a 3‐story steel frame with equipment on the first floor, a magnetorheological (MR)‐damper together with a sliding friction pendulum isolation system is placed between the equipment and floor to reduce the vibration of the equipment. Various control algorithms are used for this semi‐active control studies, including the decentralized sliding mode control (DSMC) and LQR control. The passive‐on and passive‐off control of MR damper is used as a reference for the discussion on the control effectiveness. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
A tuned mass damper (TMD) system consists of an added mass with properly functioning spring and damping elements for providing frequency‐dependent damping in a primary structure. The advantage of a friction‐type TMD, that is, a nonlinear TMD, is its energy dissipation via a friction mechanism. In contrast, the disadvantages of a passive friction TMD (PF‐TMD) are its fixed and predetermined slip load and loss of tuning and energy dissipation capabilities when it is in a stick state. A semi‐active friction TMD (SAF‐TMD) is used to overcome these disadvantages. The SAF‐TMD can adjust its slip force in response to structure motion. To verify its feasibility, a prototype SAF‐TMD was fabricated and tested dynamically using a shaking table test. A nonsticking friction control law was used to keep the SAF‐TMD activated and in a slip state in earthquakes at varying intensities. The shaking table test results demonstrated that: (i) the experimental results are consistent with the theoretical results; (ii) the SAF‐TMD is more effective than the PF‐TMD given a similar peak TMD stroke; and (iii) the SAF‐TMD can also prevent a residual TMD stroke in a PF‐TMD system. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
Although the design and applications of linear tuned mass damper (TMD) systems are well developed, nonlinear TMD systems are still in the developing stage. Energy dissipation via friction mechanisms is an effective means for mitigating the vibration of seismic structures. A friction‐type TMD, i.e. a nonlinear TMD, has the advantages of energy dissipation via a friction mechanism without requiring additional damping devices. However, a passive‐friction TMD (PF‐TMD) has such disadvantages as a fixed and pre‐determined slip load and may lose its tuning and energy dissipation abilities when it is in the stick state. A novel semi‐active‐friction TMD (SAF‐TMD) is used to overcome these disadvantages. The proposed SAF‐TMD has the following features. (1) The frictional force of the SAF‐TMD can be regulated in accordance with system responses. (2) The frictional force can be amplified via a braking mechanism. (3) A large TMD stroke can be utilized to enhance control performance. A non‐sticking friction control law, which can keep the SAF‐TMD activated throughout an earthquake with an arbitrary intensity, was applied. The performance of the PF‐TMD and SAF‐TMD systems in protecting seismic structures was investigated numerically. The results demonstrate that the SAF‐TMD performs better than the PF‐TMD and can prevent a residual stroke that may occur in a PF‐TMD system. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Vibration mitigation using smart, reliable and cost‐effective mechanisms that requires small activation power is the primary objective of this paper. A semi‐active controller‐based neural network for base‐isolation structure equipped with a magnetorheological (MR) damper is presented and evaluated. An inverse neural network model (INV‐MR) is constructed to replicate the inverse dynamics of the MR damper. Next, linear quadratic Gaussian (LQG) controller is designed to produce the optimal control force. Thereafter, the LQG controller and the INV‐MR models are linked to control the structure. The coupled LQG and INV‐MR system was used to train a semi‐active neuro‐controller, designated as SA‐NC, which produces the necessary control voltage that actuates the MR damper. To evaluate the proposed method, the SA‐NC is compared to passive lead–rubber bearing isolation systems (LRBs). Results revealed that the SA‐NC was quite effective in seismic response reduction for wide range of motions from moderate to severe seismic events compared to the passive systems. In addition, the semi‐active MR damper enjoys many desirable features, such as its inherent stability, practicality and small power requirements. The effectiveness of the SA‐NC is illustrated and verified using simulated response of a six‐degree‐of‐freedom model of a base‐isolated building excited by several historical earthquake records. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

12.
A damper device based on shape memory alloy (SMA) wires is developed for structural control implementation. The design procedures of the SMA damper are presented. As a case study, eight such SMA dampers are installed in a frame structure to verify the effectiveness of the damper devices. Experimental results show that vibration decay of the SMA damper controlled frame is much faster than that of the uncontrolled frame. The finite‐element method is adopted to conduct the free and forced vibration analysis of the controlled and uncontrolled frame. The experimental and numerical results illustrate that the developed SMA dampers are very effective in reducing structural response and have great potential for use as efficient energy dissipation devices with the advantages of good control of force and no lifetime limits, etc. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

13.
In the field of civil engineering, magnetorheological fluid (MRF) damper-based semi-active control systems have received considerable attention for use in protecting structures from natural hazards such as strong earthquakes and high winds. In this paper, the MRF damper-based semi-active control system is applied to a long-span spatially extended structure and its feasibility is discussed. Meanwhile, a _trust-region method based instantaneous optimal semi-active control algorithm (TIOC) is proposed to improve the performance of the semi-active control system in a multiple damper situation. The proposed TIOC describes the control process as a bounded constraint optimization problem, in which an optimal semi- active control force vector is solved by the trust-region method in every control step to minimize the structural responses. A numerical example of a railway station roof structure installed with MRF-04K dampers is presented. First, a modified Bouc- Wen model is utilized to describe the behavior of the selected MRF-04K damper. Then, two semi-active control systems, including the well-known clipped-optimal controller and the proposed TIOC controller, are considered. Based on the characteristics of the long-span spatially extended structure, the performance of the control system is evaluated under uniform earthquake excitation and travelling-wave excitation with different apparent velocities. The simulation results indicate that the MR fluid damper-based semi-active control systems have the potential to mitigate the responses of full-scale long-span spatially extended structures under earthquake hazards. The superiority of the proposed TIOC controller is demonstrated by comparing its control effectiveness with the clipped-optimal controller for several different cases.  相似文献   

14.
压电材料是一种新型智能材料。本文将压电材料和被动摩擦阻尼器相结合设计出一种新型智能摩擦阻尼器,并采用基于经典最优控制理论的半主动控制策略对高耸钢塔结构风振反应的控制进行了研究,对国内即将兴建的第一高钢电视塔──合肥翡翠电视塔进行了算例分析。为满足摩擦阻尼器对高耸钢塔结构风振控制的特殊需要、文中还建立了房耸钢塔结构的空间桁架有限元模型和串联多自由度体系模型,并在形成广义控制力作用位置矩阵和计算摩擦阻尼器两端的相对位移的过程中综合地运用了这两种力学模型。本文研究表明,压电材料智能摩擦阻尼器可以有效地抑制高耸钢塔结构的风振反应。  相似文献   

15.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
一种新型金属变摩擦耗能器的研发与应用   总被引:5,自引:0,他引:5  
基于被动控制理论,提出一种新型的金属变摩擦耗能阻尼器。通过改变金属摩擦面的摩擦面积,使摩擦系数具有随位移改变而变化的特性。在金属摩擦学理论的基础上,建立了金属变摩擦耗能器的阻尼力计算模型与产品的开发。理论计算与实验数据表明:新型金属变摩擦耗能器的减震性能显著优于常规阻尼器,避免了传统阻尼装置(如油阻尼器)存在的造价高、维护复杂、易漏油的问题;克服了常规摩擦耗能器不能在不同大小荷载作用下保持同样控制效果的缺点,能做到抗震耗能器在不同荷载下保持很好的抗震效果,真正做到"小震小位移少耗能,大震大位移多耗能"的智能控制。  相似文献   

17.
There has been a significant increase in the size of building structures in recent years. Huge structures such as high‐rise buildings and large‐domed stadiums require high‐performance structural control, including the use of high‐capacity dampers, especially in an earthquake‐prone country like Japan. The objective of the present study was the enhancement of both human and structural safety in such structures through the development of a rate‐dependent type of damper with a high damping capacity. Among the various available types of rate‐dependent dampers, the authors focused on the oil damper owing to its stable performance against long‐duration vibrations. The target maximum damping force was 6000 kN, which is higher than that of any existing oil damper utilized in building structures. The authors developed a novel concept for achieving this high capacity while maintaining the size of the damper within acceptable dimensions from an architectural point of view. The concept involves the use of multiple damper units that produce mechanically parallel damping forces spatially arranged in series. As a prototype, a 1500‐kN oil damper was fabricated by combining three 500‐kN dampers. The 1500‐kN prototype damper was conceived as a full‐scale prototype of a damper that is more slender than comparable commercially available dampers in Japan, and as a scaled model of the proposed 6000‐kN damper. Sinusoidal loading tests were conducted on the prototype damper using a frequency range of 0.1–1.5 Hz and a velocity range of 0.4–300 mm/s. The results confirmed that the damper produced the design damping forces. The results of earthquake loading tests also revealed that the damper exerted a stable damping force against a large earthquake and maintained its performance after the earthquake. The damper is particularly effective against earthquakes with long‐period components that could increase the temperature of a damper. This is afforded by its high heat capacity compared to conventional dampers. Considering that the proposed 6000‐kN damper will generate a damping force that is about 2–3 times that of the strongest conventional oil damper, existing manufacturer test machines would be inadequate for evaluating its full performance characteristics. To address this issue, the authors also propose a test method for evaluating the overall damping force. The method is premised on the fact that the characteristic feature of the proposed damper is its combination of multiple damper units. The overall performance is thus evaluated using the test results for the individual damper units while the other dampers are bypassed. This method was verified by the results of the abovementioned sinusoidal loading tests, with the error for the 1500‐kN prototype damper found to be less than 5%. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

18.
Viscoelastic–plastic (VEP) dampers are hybrid passive damping devices that combine the advantages of viscoelastic and hysteretic damping. This paper first formulates a semi‐analytical procedure for predicting the peak response of nonlinear SDOF systems equipped with VEP dampers, which forms the basis for the generation of Performance Spectra that can then be used for direct performance assessment and optimization of VEP damped structures. This procedure is first verified against extensive nonlinear time‐history analyses based on a Kelvin viscoelastic model of the dampers, and then against a more advanced evolutionary model that is calibrated to characterization tests of VEP damper specimens built from commercially available viscoelastic damping devices, and an adjustable friction device. The results show that the proposed procedure is sufficiently accurate for predicting the response of VEP systems without iterative dynamic analysis for preliminary design purposes. A design method based on the Performance Spectra framework is then proposed for systems equipped with passive VEP dampers and is applied to enhance the seismic response of a six‐storey steel moment frame. The numerical simulation results on the damped structure confirm the use of the Performance Spectra as a convenient and accurate platform for the optimization of VEP systems, particularly during the initial design stage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
Multi‐storey main buildings constructed with a low‐rise podium structure possess some architectural merits but the setback features of such a building complex may lead to seismic response enlargement of the main buildings. This paper explores the possibility of using passive friction dampers to connect the podium structure to the main buildings to prevent their seismic response enlargement without violating the architectural features. A series of shaking table tests were carried out on one 3‐storey and one 12‐storey building models in fully‐separated, rigidly connected, and friction damper‐linked configurations. Four sets of seismic ground motions were selected as inputs to the shaking table. The control competence of two buildings linked with friction damper was evaluated by comparison of their responses with those from fully‐separated and rigidly connected cases. Experimental results showed that unfavourable seismic response amplification did occur in the building complex in the rigidly connected case. By contrast, friction damper showed effectiveness in reducing absolute acceleration and interstorey drift responses of both buildings if friction force level was appropriately applied. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
A semi‐active multi‐step predictive control (SAMPC) system with magnetorheological (MR) dampers is developed to reduce the seismic responses of structures. This system can predict the next multi‐step responses of structure according to the current state and has a function of self‐compensation for time delay that occurred in real application. To study the performance of the proposed control algorithm for addressing time delay and reducing the seismic responses, a numerical example of an 11‐story structure with MR dampers is presented. Comparison with the uncontrolled structure indicates that both the peak and the norm values of structural responses are all clearly reduced when the predictive length l?10 and the delayed time step d?20 are selected, and the SAMPC strategy can guarantee the stability of the controlled structure and reduce the effects of time delay on controlled responses to a certain extent. A performance comparison is also made between the SAMPC strategy and the passive‐off and passive‐on methods; results indicate that this SAMPC system is more effective than the two passive methods in reducing structural responses subjected to earthquakes. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号