1.
Using the concept of lumped masses and rigid floor slabs, several mathematical models were built using a popular PC‐based finite element program to model a tall building with a frame‐core wall structural system. These models were analysed to obtain the first nine mode shapes and their natural frequencies which were compared with those from field measurements, using numerical correlation indicators. The comparison shows several factors that can have a significant effect on the analysis results. Firstly, outriggers connecting the outer framed tube system to the inner core walled tube system have a significant effect on fundamental translational mode behaviour. Secondly, detailed modelling of the core considering major and minor openings as well as internal thin walls has the strongest influence on torsional behaviour, whose measurements were shown to be an important aspect of the dynamic behaviour for the structure studied. Fine tuning of an analytical model requires not just considering variation in values of structural parameters but also attention to fine detail. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

2.
The outrigger system is an effective means of controlling the seismic response of core‐tube type tall buildings by mobilizing the axial stiffness of the perimeter columns. This study investigates the damped‐outrigger, incorporating the buckling‐restrained brace (BRB) as energy dissipation device (BRB‐outrigger system). The building's seismic responses are expected to be effectively reduced because of the high BRB elastic stiffness during minor earthquakes and through the stable energy dissipation mechanism of the BRB during large earthquakes. The seismic behavior of the BRB‐outrigger system was investigated by performing a spectral analysis considering the equivalent damping to incorporate the effects of BRB inelastic deformation. Nonlinear response history analyses were performed to verify the spectral analysis results. The analytical models with building heights of 64, 128, and 256 m were utilized to investigate the optimal outrigger elevation and the relationships between the outrigger truss flexural stiffness, BRB axial stiffness, and perimeter column axial stiffness to achieve the minimum roof drift and acceleration responses. The method of determining the BRB yield deformation and its effect on overall seismic performance were also investigated. The study concludes with a design recommendation for the single BRB‐outrigger system.  相似文献   

3.
For almost a decade, a 66‐storey, 280m tall building in Singapore has been instrumented to monitor its dynamic responses to wind and seismic excitations. The dynamic characteristics of the tall building have been investigated via both the finite element method and the experimental modal analysis. The properties of the finite element model have been shown to correlate well with those derived from the data recorded during the ambient vibration tests. During the study period, 21 sets of earthquake ground motions have been recorded at the building site. The basement motions may be divided into three categories based on their predominant frequency components with respect to the building's fundamental frequency. The calibrated three‐dimensional finite element model is employed to simulate the seismic response of the tall building. Correlation analysis of the time histories between the recorded data and the simulated results has been carried out. The correlation analysis results show that the simulated dynamic response time histories match well with those of the recorded dynamic responses at the roof level. The results also show that the simulated maximum response at the roof level is close to the peak response recorded during the earthquakes. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

4.
This paper presents a methodology to estimate element‐by‐element demand‐to‐capacity ratios in instrumented steel moment‐resisting frames subject to earthquakes. The methodology combines a finite element model and acceleration measurements at various points throughout the building to estimate time history of displacements and internal force demands in all members. The estimated demands and their uncertainty are compared with code‐based capacity from which probabilistic bounds of demand‐to‐capacity ratios are obtained. The proposed methodology is verified using a simulated six‐story building and validated using acceleration data from California Strong Motion Instrumentation Programstation 24370 during the Northridge and Sierra Madre earthquakes.  相似文献   

5.
The height of 101‐storey Shanghai World Financial Center Tower is 492m above ground making it possible the tallest building in the world when completed. Three parallel structural systems including mega‐frame structure, reinforced concrete and braced steel services core and outrigger trusses, are combined to resist vertical and lateral loads. The building could be classified as a vertically irregular structure due to a number of stiffened and transfer stories in the building. Complexities related to structural system layout are mainly exhibited in the design of services core, mega‐diagonals and outrigger trusses. According to Chinese Code, the height 190 m of the building clearly exceeds the stipulated maximum height of for a composite frame/reinforced concrete core building. The aspect ratio of height to width also exceeds the stipulated limit of 7 for seismic design intensity 7. A 1/50 scaled model is made and tested on shaking table under a series of one and two‐dimensional base excitations with gradually increasing acceleration amplitudes. This paper presents the dynamic characteristics, the seismic responses and the failure mechanism of the structure. The test results demonstrate that the structural system is a good solution to withstand earthquakes. The inter‐storey drift and the overall behaviour meet the requirements of Chinese Design Code. Furthermore, weak positions under seldom‐occurred earthquakes of seismic design intensity 8 are found based on the visible damages on the testing model, and some corresponding suggestions are proposed for the engineering design of the structure under extremely strong earthquake. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
In a companion paper two different modelling approaches have been described, operating at the meso‐scale of the fibre elements and at the micro‐scale of the finite element (FE) method. The aim of this paper is to explore the efficiency of these models in the pushover analysis for the seismic assessment of existing reinforced concrete (RC) structures. To this purpose a prototype reference structure, one of the RC shear walls designed according to the multi‐fuse concept and tested on shaking table for the CAMUS Project, is modelled at different levels of refinement. At the micro‐scale the reinforcement and anchorage details are described with increasing accuracy in separate models, whereas at the meso‐scale one single model is used, where each element represents a large part of the structure. Static incremental non‐linear analyses are performed with both models to derive a capacity curve enveloping the experimental results and to reproduce the damage pattern at the displacement level where failure is reached. The comparison between experimental and numerical results points out the strong and weak points of the different models inside the procedure adopted, and the utility of an integration of results from both approaches. This study confirms, even for the rather difficult case at study, the capability of the pushover in reproducing the non‐linear dynamic response, both at a global and a local level, and opens the way to the use of the models within a displacement‐based design and assessment procedure. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
This work focuses on the modelling issues related to the adoption of the pushover analysis for the seismic assessment of existing reinforced concrete (RC) structures. To this purpose a prototype reference structure, one of the RC shear walls designed according to the multi‐fuse concept and tested on shaking table for the CAMUS project, is modelled at different levels of refinement. The meso‐scale of a stiffness‐based fibre element and the micro‐scale of the finite element (FE) method are herein adopted; in the latter separate elements are adopted for the concrete, the steel and the steel–concrete interface. This first of the two companion papers presents in detail the wall under study, illustrating the design philosophy, the geometry of the wall, the instrumentation set‐up and the test programme. The two modelling approaches are then described; the most important points in terms of element formulation and constitutive relations for materials are presented and discussed for each approach, in the light of the particular design of the wall and of its experimental behaviour. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
A reliability‐based output feedback control methodology is presented for controlling the dynamic response of systems that are represented by linear state‐space models. The design criterion is based on a robust failure probability for the system. This criterion provides robustness for the controlled system by considering a probability distribution over a set of possible system models with a stochastic model of the excitation so that robust performance is expected. The control command signal can be calculated using incomplete response measurements at previous time steps without requiring state estimation. Examples of robust structural control using an active mass driver on a shear building model and on a benchmark structure are presented to illustrate the proposed method. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

10.
Reinforced concrete (R/C) frame buildings designed according to older seismic codes represent a large part of the existing building stock worldwide. Their structural elements are often vulnerable to shear or flexure‐shear failure, which can eventually lead to loss of axial load resistance of vertical elements and initiate vertical progressive collapse of a building. In this study, a hysteretic model capturing the local shear response of shear‐deficient R/C elements is described in detail, with emphasis on post‐peak behaviour; it differs from existing models in that it considers the localisation of shear strains after the onset of shear failure in a critical length defined by the diagonal failure planes. Additionally, an effort is made to improve the state of the art in post‐peak shear response modelling, by compiling the largest database of experimental results for shear and flexure‐shear critical R/C columns cycled well beyond the onset of shear failure and/or up to the onset of axial failure, and developing empirical relationships for the key parameters defining the local backbone post‐peak shear response of such elements. The implementation of the derived local hysteretic shear model in a computationally efficient beam‐column finite element model with distributed shear flexibility, which accounts for all deformation types, will be presented in a companion paper.  相似文献   

11.
As high‐rise buildings are built taller and more slender, their dynamic behavior becomes an increasingly critical design consideration. Wind‐induced vibrations cause an increase in the lateral wind design loads, but more importantly, they can be perceived by building occupants, creating levels of discomfort ranging from minor annoyance to severe motion sickness. The current techniques to address wind vibration perception include stiffening the lateral load‐resisting system, adding mass to the building, reducing the number of stories, or incorporating a vibration absorber at the top of the building; each solution has significant economic consequences for builders. Significant distributed damage is also expected in tall buildings under severe seismic loading, as a result of the ductile seismic design philosophy that is widely used for such structures. In this paper, the viscoelastic coupling damper (VCD) that was developed at the University of Toronto to increase the level of inherent damping of tall coupled shear wall buildings to control wind‐induced and earthquake‐induced dynamic vibrations is introduced. Damping is provided by incorporating VCDs in lieu of coupling beams in common structural configurations and therefore does not occupy any valuable architectural space, while mitigating building tenant vibration perception problems and reducing both the wind and earthquake responses of the structure. This paper provides an overview of this newly proposed system, its development, and its performance benefits as well as the overall seismic and wind design philosophy that it encompasses. Two tall building case studies incorporating VCDs are presented to demonstrate how the system results in more efficient designs. In the examples that are presented, the focus is on the wind and moderate earthquake responses that often govern the design of such tall slender structures while reference is made to other studies where the response of the system under severe seismic loading conditions is examined in more detail and where results from tests conducted on the viscoelastic material and the VCDs in full‐scale are presented. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
The structural response to high‐frequency ground motions is complicated due to the involvement of local‐mode vibration. At present such a characteristic is not well recognized and this can cause confusion over the analytical and experimental modelling of the corresponding response and damage. The fact that most existing regulatory guides for limits on allowable construction vibrations are necessarily simplified for administrative reasons calls upon the derivation of more sophisticated approaches for special cases. This requires accumulation of pertinent experimental evidence. This paper attempts to provide some insights into the local‐mode dynamic response characteristics, with emphasis on appropriate modelling techniques and experimental measurements. A preliminary testing program is reported, in which efforts were made to reproduce high‐frequency response with a reduced scale reinforced concrete model with shaking table facilities. The results demonstrate the dependence of the response amplitudes with the excitation frequency. On a ppv‐basis, the current test results indicate that a substantial increase of the allowable ppv value from those specified by various standards may be considered for structural damage to reinforced concrete building structures. More analytical and experimental data are needed for further evaluation of the local‐mode effects and to quantify their impact on the structural damage process. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

13.
高层建筑与相邻多层建筑间的动力相互作用   总被引:2,自引:0,他引:2  
本文阐述了高层建筑与相邻多层建筑间的动力相互作用问题,应用波动理论,采用二维显式有限元的方法对这个问题进行了分析,通过实例计算得到一些有益的结论,如高导建筑对相邻多层建筑影响较大;竖向反应影响比水平方面影响大;这种影随着距离的增大而减少等。  相似文献   

14.
This paper investigates the implications of designing for uniform hazard versus uniform risk for light‐frame wood residential construction subjected to earthquakes in the United States. Using simple structural models of one‐story residences with typical lateral force‐resisting systems (shear walls) found in buildings in western, eastern and central regions of the United States as illustrations, the seismic demands are determined using nonlinear dynamic time‐history analyses, whereas the collapse capacities are determined using incremental dynamic analyses. The probabilities of collapse, conditioned on the occurrence of the maximum considered earthquakes and design earthquakes stipulated in ASCE Standard 7‐05, and the collapse margins of these typical residential structures are compared for typical construction practices in different regions in the United States. The calculated collapse inter‐story drifts are compared with the limits stipulated in FEMA 356/ASCE Standard 41‐06 and observed in the recent experimental testing. The results of this study provide insights into residential building risk assessment and the relation between building seismic performance implied by the current earthquake‐resistant design and construction practices and performance levels in performance‐based engineering of light‐frame wood construction being considered by the SEI/ASCE committee on reliability‐based design of wood structures. Further code developments are necessary to achieve the goal of uniform risk in earthquake‐resistant residential construction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
The time delay resulting from the servo hydraulic systems can potentially destabilize the real‐time dynamic hybrid testing (RTDHT) systems. In this paper, the discrete‐time root locus technique is adopted to investigate the delay‐dependent stability performance of MDOF RTDHT systems. Stability analysis of an idealized two‐story shear frame with two DOFs is first performed to illustrate the proposed method. The delay‐dependent stability condition is presented for various structural properties, time delay, and integration time steps. Effects of delay compensation methods on stability are also investigated. Then, the proposed method is applied to analyze the delay‐dependent stability of a single shaking table RTDHT system with an 18‐DOF finite element numerical substructure, and corresponding RTDHTs are carried out to verify the theoretical results. Furthermore, the stability behavior of a finite element RTDHT system with two physical substructures, loaded by twin shaking tables, is theoretically and experimentally investigated. All experimental results convincingly demonstrate that the delay‐dependent stability analysis on the basis of the discrete‐time root locus technique is feasible. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
In this study, genetic algorithms are applied to design controllers for the wind‐excited vibration reduction of a 76‐story tall building in the second‐generation benchmark problem. Design criteria and constraints including the comfort requirement for building occupants and the control robustness are directly incorporated in the formulation and evaluation of the fitness and penalty function of the genetic algorithm‐based control design. The method is efficient in obtaining optimal design with multiple constraint conditions. Two controllers are designed with realistic constraints and different robustness criteria. The corresponding results are investigated and compared with LQG optimal control results. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

17.
Shear‐wall dominant multistorey reinforced concrete structures, constructed by using a special tunnel form technique are commonly built in countries facing a substantial seismic risk, such as Chile, Japan, Italy and Turkey. In spite of their high resistance to earthquake excitations, current seismic code provisions including the Uniform Building Code (International Conference of Building Officials, Whittier, CA, 1997) and the Turkish Seismic Code (Specification for Structures to be Built in Disaster Areas, Ankara, Turkey, 1998) present limited information for their design criteria. In this study, consistency of equations in those seismic codes related to their dynamic properties are investigated and it is observed that the given empirical equations for prediction of fundamental periods of this specific type of structures yield inaccurate results. For that reason, a total of 80 different building configurations were analysed by using three‐dimensional finite‐element modelling and a set of new empirical equations was proposed. The results of the analyses demonstrate that given formulas including new parameters provide accurate predictions for the broad range of different architectural configurations, roof heights and shear‐wall distributions, and may be used as an efficient tool for the implicit design of these structures. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

18.
Most buildings in Singapore are lightly reinforced concrete structures, which are mainly designed for gravity loading only, because Singapore is an island country located in a low‐to‐moderate seismic region. The dynamic properties of a typical high‐rise residential building with a long, narrow rectangular floor plan are studied using both experimental and numerical methods. The effects of the brick infill walls and the flexible diaphragms on the dynamic characteristics of the building are discussed in detail. The results from the ambient vibration tests are correlated with the numerical results of three different finite element models with different levels of sophistication. They include a bare frame model, a frame model with brick infill walls, and a frame model with both brick infill walls and flexible diaphragms. The dynamic properties of the third model match very well with the measured results in terms of both the natural frequencies and the mode shapes. The correlation results demonstrate the respective effects of the brick infill walls and the flexible diaphragms on the dynamic characteristics of the narrow‐rectangle building structure. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

19.
A two‐story buckling‐restrained brace (BRB) frame was tested under bidirectional in‐plane and out‐of‐plane loading to evaluate the BRB stability and gusset plate design. The test comprised pseudo‐dynamic loadings using the 1999 Chi‐Chi earthquake scaled to the 50%, 10%, and 2% probability of exceedance in 50 years and a cyclic regime of increasing amplitudes of up to 3.0% story drift ratio (SDR). The specimen had a unique configuration where the beams were connected to the columns through shear tabs welded to the column flanges and bolted to the beam webs. Stable hysteretic behavior with only minor cracking at the gusset‐to‐column welds was observed under the pseudo‐dynamic tests, with maximum in‐plane and out‐of‐plane SDRs of 2.24% and 1.47% respectively. Stable behavior continued into the cyclic test where fracture of the gusset‐to‐column welds occurred in the first cycle to simultaneous bidirectional SDR of 3.0%. The observed BRB stability is consistent with a methodology developed for BRB frames under simultaneous in‐plane and out‐of‐plane drifts. The specimen behavior was studied using a finite element model. It was shown that gusset plates are subjected to a combination of BRB force and frame action demands, with the latter increasing the gusset‐to‐beam and gusset‐to‐column interface demands by an average of 69% and 83% respectively. Consistent with the test results, failure at the gusset‐to‐column interfaces is computed when frame action demands are included, thus confirming that not considering frame action demands may results in unconservative gusset plate designs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
高层建筑转换梁上短肢剪力墙抗震试验和分析   总被引:1,自引:1,他引:0  
本文依据实际工程的背景,通过高层建筑转换梁上的两个短肢剪力墙试件的拟静力试验,研究其破坏模式,抗震性能和计算方法。在试验研究的基础上,采用非线性有限元方法进行分析计算,为解决实际的复杂体型高层建筑抗震设计提供一些建议。  相似文献   