首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
There are several methods for determining the spatial distribution and magnitude of groundwater inputs to streams. We compared the results of conventional methods [dye dilution gauging, acoustic Doppler velocimeter (ADV) differential gauging, and geochemical end‐member mixing] to distributed temperature sensing (DTS) using a fibre‐optic cable installed along 900 m of Ninemile Creek in Syracuse, New York, USA, during low‐flow conditions (discharge of 1·4 m3 s?1). With the exception of differential gauging, all methods identified a focused, contaminated groundwater inflow and produced similar groundwater discharge estimates for that point, with a mean of 66·8 l s?1 between all methods although the precision of these estimates varied. ADV discharge measurement accuracy was reduced by non‐ideal conditions and failed to identify, much less quantify, the modest groundwater input, which was only 5% of total stream flow. These results indicate ambient tracers, such as heat and geochemical mixing, can yield spatially and quantitatively refined estimates of relatively modest groundwater inflow even in large rivers. DTS heat tracing, in particular, provided the finest spatial characterization of groundwater inflow, and may be more universally applicable than geochemical methods, for which a distinct and consistent groundwater end member may be more difficult to identify. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
Exposure from groundwater contamination to aquatic receptors residing in receiving surface water is dependent upon the rate of contaminated groundwater discharge. Characterization of groundwater fluxes is challenging, especially in coastal environments where tidal fluctuations result in transient groundwater flows towards these receptors. This can also be further complicated by the high spatial heterogeneity of subsurface deposits enhanced by anthropogenic influences such as the mixing of natural sediments and backfill materials, the presence of subsurface built structures such as sheet pile walls or even occurrence of other sources of contaminant discharge. In this study, the finite volume point dilution method (FVPDM) was successfully used to characterize highly transient groundwater flows and contaminant mass fluxes within a coastal groundwater flow system influenced by marked tides. FVPDM tests were undertaken continuously for more than 48 h at six groundwater monitoring wells, in order to evaluate groundwater flow dynamics during several tide cycles. Contaminant concentrations were measured simultaneously which allowed calculating contaminant mass fluxes. The study highlighted the importance of the aquifer heterogeneity, with groundwater fluxes ranging from 10−7 to 10−3 m/s. Groundwater flux monitoring enabled a significant refinement of the conceptual site model, including the fact that inversion of groundwater fluxes was not observed at high tide. Results indicated that contaminant mass fluxes were particularly higher at a specific monitoring well, by more than three orders of magnitude, than at other wells of the investigated aquifer. This study provided crucial information for optimizing further field investigations and risk mitigation measures.  相似文献   

3.
Temperature measurements have been used by a variety of researchers to gain insight into groundwater discharge patterns. However, much of this research has reduced the problem to heat and fluid flow in one dimension for ease of analysis. This approach is seemingly at odds with the goal of determining spatial variability in specific discharge, which implies that the temperature field will vary in more than one dimension. However, it is unclear how important the resulting discrepancies are in the context of determining groundwater discharge to surface water bodies. In this study, the importance of these variations is examined by testing two popular one‐dimensional analytical solutions with stochastic models of heat and fluid flow in a two‐dimensional porous medium. For cases with low degrees of heterogeneity in hydraulic conductivity, acceptable results are possible for specific discharges between 10?7 and 10?5 m/s. However, conduction into areas with specific discharges less than 10?7 m/s from adjacent areas can lead to significant errors. In some of these cases, the one‐dimensional solutions produced estimates of specific discharge of nearly 10?6 m/s. This phenomenon is more likely in situations with greater degrees of heterogeneity.  相似文献   

4.
Significant attention has been given to hyporheic water fluxes induced by hydromorphologic processes in streambeds and the effects they have on stream ecology. However, the impact of hyporheic fluxes on regional groundwater flow discharge zones as well as the interaction of these flows are much less investigated. The groundwater-hyporheic interactive flow not only governs solute mass and heat transport in streams but also controls the retention of solute and contamination following the discharge of deep groundwater, such as naturally occurring solutes and leakage from geological waste disposal facilities. Here, we applied a physically based modeling approach combined with extensive hydrologic, geologic and geographical data to investigate the effect of hyporheic flow on groundwater discharge in the Krycklan catchment, located in a boreal landscape in Sweden. Regional groundwater modeling was conducted using COMSOL Multiphysics by considering geologic heterogeneity and infiltration constraint of the groundwater circulation intensity. Moreover, the hyporheic flow was analyzed using an exact spectral solution accounting for the fluctuating streambed topography and superimposed with the regional groundwater flow. By comparing the discharge flow fields with and without consideration of hyporheic flows, we found that the divergence of the discharge was substantially enhanced and the distribution of the travel times of groundwater was significantly shifted toward shorter times due to the presence of hyporheic flow. Particularly important is that the groundwater flow paths contract near the streambed interface due to the hyporheic flow, which leads to a phenomenon that we name “fragmentation” of coherent areas of groundwater upwelling in pinhole-shaped stream tubes.  相似文献   

5.
Small‐scale heterogeneities and large changes in hydraulic gradient over short distances can create preferential groundwater flow paths that discharge to lakes. A 170 m2 grid within an area of springs and seeps along the shore of Shingobee Lake, Minnesota, was intensively instrumented to characterize groundwater‐lake interaction within underlying organic‐rich soil and sandy glacial sediments. Seepage meters in the lake and piezometer nests, installed at depths of 0·5 and 1·0 m below the ground surface and lakebed, were used to estimate groundwater flow. Statistical analysis of hydraulic conductivity estimated from slug tests indicated a range from 21 to 4·8 × 10?3 m day?1 and small spatial correlation. Although hydraulic gradients are overall upward and toward the lake, surface water that flows onto an area about 2 m onshore results in downward flow and localized recharge. Most flow occurred within 3 m of the shore through more permeable pathways. Seepage meter and Darcy law estimates of groundwater discharge agreed well within error limits. In the small area examined, discharge decreases irregularly with distance into the lake, indicating that sediment heterogeneity plays an important role in the distribution of groundwater discharge. Temperature gradients showed some relationship to discharge, but neither temperature profiles nor specific electrical conductance could provide a more convenient method to map groundwater–lake interaction. These results suggest that site‐specific data may be needed to evaluate local water budget and to protect the water quality and quantity of discharge‐dominated lakes. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
Gas‐Oil Gravity Drainage is to be enhanced by steam injection in a highly fractured, low permeability carbonate field in Oman. Following a successful pilot, field‐wide steam injection is being implemented, first of this type in the world. A dedicated monitoring program has been designed to track changes in the reservoir. Various observations are to be acquired, including, surface deformation, temperature measurements, microseismic, well logs, pressure and saturation measurements to monitor the reservoir. Because significant changes in the reservoir density are expected, time‐lapse gravimetry is also being considered. In this paper we investigate the feasibility of gravimetric monitoring of the thermally enhanced gravity drainage process at the carbonate field in Oman. For this purpose, forward gravity modelling is performed. Based on field groundwater measurements, the estimates of the hydrological signal are considered and it is investigated under what conditions the groundwater influences can be minimized. Using regularized inversion of synthetic gravity data, we analyse the achievable accuracy of heat‐front position estimates. In case of large groundwater variations at the field, the gravity observations can be significantly affected and, consequently, the accuracy of heat‐front monitoring can be deteriorated. We show that, by applying gravity corrections based on local observations of groundwater, the hydrological influences can to a large extent be reduced and the accuracy of estimates can be improved. We conclude that gravimetric monitoring of the heat‐front evolution has a great potential.  相似文献   

7.
In designing as well as in the construction of hydro-electric power plants and water-supply projects in karst, the knowledge of the location of groundwater flows is invaluable. Attempts made so far in this direction have not produced the desired results and all the methods known so far have shown to be more or less ineffective, especially with respect to deep-seated underground flows. An interesting suggestion on the possible determination of the groundwater flow location by using a specific geophysical prospecting procedure is based on the studies and knowledge of groundwater flows in the karstland of Yugoslavia. The procedure is as follows: a time-bomb thrown down a swallow-hole travels down to the groundwater flow and explodes at a predetermined moment. Elastic waves generated by the explosion propagate reaching the surface, where they are detected by properly arranged geophones that are connected with a standard seismic apparatus. By a specific graphical or arithmetical method the coordinates of the epicentre and hypocentre of the underground explosion can be worked out, and thus the location of the groundwater flow determined. By successive repetition of the experiment, i.e. by different time activation of underground explosion of the time-bomb, the location of the groundwater flow can be defined over longer paths. The success of the experiment depends upon a number of factors all of which must be met. If only one of them is overlooked, the experiment will not succeed. All this calls for great care both in preliminary work and in the course of the experiment. Substantial funds invested in and considerable time required in executing the experiment are multiply recompensed by the success of the experiment. The information obtained about the location of groundwater flows will directly affect the maximum operating pool adopted for hydro-electric power projects and the most favourable point in cutting off groundwater flows and bringing them to the surface for water-supply purposes.  相似文献   

8.
Peter G. Cook 《水文研究》2013,27(25):3694-3707
Environmental tracer methods have been used to quantify groundwater discharge to rivers for the past few decades. A number of different tracers have been used in these studies, including individual ion concentrations, electrical conductivity, stable isotopes 2H and 18O, and the dissolved gases helium, chlorofluorocarbons and radon. This paper discusses the assumptions of the method, as well as its resolution and accuracy. The method will be most accurate when the tracer concentration in groundwater is very distinct from that in the river. On the basis of typical parameters, groundwater inflow rates as low as 5 mm/day can usually be estimated with electrical conductivity and ion tracers. A lower limit of resolution of approximately 2 mm/day is usually possible with radon, principally because the ratio of the river concentration to the groundwater concentration will be higher. However, hyporheic exchange can also contribute radon to the river. Where this process is significant, it is more difficult to estimate groundwater inflow from radon activities in the river, thus reducing the accuracy of the method. For CFCs, the lower limit of resolution is approximately 30 mm/day. Helium has not been widely used but can potentially be very accurate if the groundwater is old. The method assumes steady‐state conditions and so can only be applied when river flows are stable. Sampling resolution is also particularly important for dissolved gases, and uncertainty in where groundwater inflow occurs between sampling points can cause large uncertainty in inflow rates if the distance between sample locations is large. Poor mixing of solutes within the river can limit the method if the river is wide and shallow. When correctly applied, however, the environmental tracer method is able to provide robust estimates of groundwater discharge at a scale and accuracy that is not possible with most other methods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Streamwater discharge and chemistry of two small catchments on Catoctin Mountain in north-central Maryland have been monitored since 1982. Repetitive seasonal cycles in stream-water chemistry have been observed each year, along with seasonal cycles in the volume of stream discharge and in groundwater levels. The hypothesis that the observed streamwater chemical cycles are related to seasonal changes in the hydrological flow paths that contribute to streamflow is examined using a combination of data on groundwater levels, shallow and deep groundwater chemistry, streamwater discharge, streamwater chemistry, soil-water chemistry, and estimates of water residence times. The concentrations of constituents derived from rock weathering, particularly bicarbonate and silica, increase in streamwater during the summer when the water table is below the regolith-bedrock interface and stream discharge consists primarily of deep groundwater from the fractured-bedrock aquifer. Conversely, the concentrations in streamwater of atmospherically derived components, particularly sulfate, increase in winter when the water table is above the regolith-bedrock interface and stream discharge consists primarily of shallow groundwater from the regolith. Tritium and chlorofluorocarbon (CFC) measurements suggest that the groundwater in these systems is young, with a residence time of less than several years. The results of this study have implications for the design of large-scale water-quality monitoring programs.  相似文献   

10.
Heat was used as a tracer to measure infiltration rates from a recharge basin. The propagation of diurnal oscillation of surface water temperature into the basin bed was monitored along a transect using Fiber Optic Distributed Temperature Sensing (FODTS). The propagation rate was related to downward specific discharge using standard theory of heat advection and dispersion in saturated porous media. An estimate of the temporal variation of heat propagation was achieved using a wavelet transform to find the phase lag between the surface temperature diurnal oscillation and the correlated oscillation at 0.33 and 0.98 m below the bed surface. The wavelet results compared well to a constant velocity model of thermal advection and dispersion during periods of relatively constant discharge rates. The apparent dispersion of heat was found to be due primarily to hydrodynamic mechanisms rather than thermal diffusion. Specific discharge estimates using the FODTS technique also compared well to water balance estimates over a four month period, although there were occasional deviations that have yet to be adequately explained. The FODTS technique is superior to water balance in that it produces estimates of infiltration rate every meter along the cable transect, every half hour. These high resolution measurements highlighted areas of low infiltration and demonstrated the degradation of basin efficiency due to source waters of high suspended solids. FODTS monitoring promises to be a useful tool for diagnosing basin performance in an era of increasing groundwater demand.  相似文献   

11.
C.D. Mackie 《Ground water》2014,52(4):613-617
Impacts of underground longwall mining on groundwater systems are commonly assessed using numerical groundwater flow models that are capable of forecasting changes to strata pore pressures and rates of groundwater seepage over the mine life. Groundwater ingress to a mining operation is typically estimated using zone budgets to isolate relevant parts of a model that represent specific mining areas, and to aggregate flows at nominated times within specific model stress periods. These rates can be easily misinterpreted if simplistic averaging of daily flow budgets is adopted. Such misinterpretation has significant implications for design of underground dewatering systems for a new mine site or it may lead to model calibration errors where measured mine water seepage rates are used as a primary calibration constraint. Improved estimates of groundwater ingress can be made by generating a cumulative flow history from zone budget data, then differentiating the cumulative flow history using a low order polynomial convolved through the data set.  相似文献   

12.
ABSTRACT

Studies of groundwater discharge to seas and oceans are important to hydrology and geology. Some concepts and notions of groundwater outflow to the world's oceans are presented. A method for evaluating submarine groundwater discharge is discussed. Discharge estimates for the Pacific Ocean along all its coastline and major islands are given. The general characteristics of groundwater discharge and the factors governing discharge values are described. The groundwater outflow to the Pacific Ocean is shown to follow latitudinal physiographic zonality.  相似文献   

13.
Unzen volcano is situated on Shimabara Peninsula, western Kyushu, Japan. On the flank of the volcano, the Obama, Unzen and Shimabara hot springs are aligned in a direction from the southwest to the northeast across the peak. At Obama and Shimabara, heat is transferred mainly by water flow. But at Unzen heat is transferred by the discharge of natural steam and by conduction as well as water flow. In order to estimate the heat discharge by mechanisms other than water flow, infrared measurements by a helicopter-borne thermocamera were conducted over the Unzen hot spring area. The heat discharge was calculated from the thermal image by a method based on heat balance of the ground surface resulting in a value of 1.9 × 106 cal/s (7.9 MW). The heat discharged by all mechanisms including that by water flow is estimated to be 5.0 × 106 cal/s (21 MW). Similar preliminary estimates have been made for heat discharge at the Obama and Shimabara hot springs giving values of about 1.2 × 107 cal/s (50 MW) and 1.0 × 105 cal/s (0.4 MW), respectively. These values indicate that the heat discharge decreases with distance from the southwest to the northeast direction across the volcano. The total heat discharge from three hot spring areas on Unzen volcano is about 1.7 × 107 cal/s (71 MW).The heat balance method appears useful for quantitative analysis of regional trends but its accuracy may not be always sufficient for detailed surveys. Several methods of determining heat flow, including the heat balance method, were compared at a test field in the Unzen hot spring area. The values obtained by the heat balance method coincide roughly with the other results but more detailed analysis is necessary to improve the accuracy of current methods of geothermal measurements.  相似文献   

14.
This paper presents a new perturbation solution of the non-linear Boussinesq equation for one-dimensional tidal groundwater flow in a coastal unconfined aquifer. Built upon the work of Parlange et al. [Parlange, J.-Y., Stagnitti, F., Starr, J.L., Braddock, R.D., 1984. Free-surface flow in porous media and periodic solution of the shallow-flow approximation, J. Hydrol., 70, 251–263], the solution adopts a new perturbation parameter that is by definition less than unit, and thus is applicable to a wider range of physical conditions within the constraint of the Boussinesq approximation. This approach avoids a secular term in the third-order perturbation equation of Parlange et al. (1984), enabling the derivation of the third- and higher-order solutions. In comparison with a numerical (“exact”) solution, the new perturbation solution is shown to be slightly more accurate than that of Parlange et al. (1984) with the second-order approximation. The obtained third-order solution exhibits considerable improvement in accuracy. In relatively simple analytical forms, the present perturbation solution will help to understand better the non-linear characteristics of tidal water table fluctuations in as modeled by the non-linear Boussinesq equation coastal unconfined aquifers.  相似文献   

15.
Groundwater discharge flux into rivers (riverine groundwater discharge or RGD) is essential information for the conservation and management of aquatic ecosystems and resources. One way to estimate area-integrated groundwater discharge into surface water bodies is to measure the concentration of a groundwater tracer within the water body. We assessed groundwater discharge using 222Rn, a tracer common in many surface water studies, through field measurements, surface water 222Rn mass balance model, and groundwater flow simulation, for the seldom studied but ubiquitous setting of a flooding river corridor. The investigation was conducted at the dam-regulated Lower Colorado River (LCR) in Austin, Texas, USA. We found that 222Rn in both the river water and groundwater in the river bank changed synchronously over a 12-hour flood cycle. A 222Rn mass balance model allowed for estimation of groundwater discharge into a 500-m long reach of the LCR over the flood. The groundwater discharge ranged between negative values (indicating recharge) to 1570 m3/h; groundwater discharge from groundwater flow simulations corroborated these estimates. However, for the dynamic groundwater discharge estimated by the 222Rn box model, assuming whether the groundwater 222Rn endmember was constant or dynamic led to notably different results. The resultant groundwater discharge estimates are also highly sensitive to river 222Rn values. We thus recommend that when using this approach to accurately characterize dynamic groundwater discharge, the 222Rn in near-stream groundwater should be monitored at the same frequency as river 222Rn. If this is not possible, the 222Rn method can still provide reasonable but approximate groundwater discharge given background information on surface water-groundwater exchange time scales.  相似文献   

16.
Water percolation and flow processes in subsurface geologic media play an important role in determining the water source for plants and the transport of contaminants or nutrients, which is essential for water resource management and the development of measures for pollution mitigation. During June 2013, the dynamics of the rainwater, soil water, subsurface flows and groundwater in a shallow Entisol on sloping farmland were monitored using a hydrometric and isotopic approach. The results showed that effective mixing of rainwater and soil water occurred in hours. The rebound phenomenon of δD profiles in soils showed that most isotope‐depleted rainwater largely bypassed the soil matrix when the water saturation in the soil was high. Preferential‐flow, which was the dominant water movement pattern in the vadose zone, occurred through the whole soil profile, and infrequent piston‐flow was mainly found at 20–40 cm in depth. The interflow in the soil layer, composed of 75.2% rainwater, was only generated when the soil profile had been saturated. Underflow in the fractured mudrock was the dominant flow type in this hillslope, and outflow was dominated by base flow (groundwater flow) with a mean contribution of 76.7%. The generation mechanism of underflow was groundwater ridging, which was superimposed upon preferential‐flow composed mainly of rainwater. The quick mixing process of rainwater and soil water and the rapid movement of the mixture through preferential channels in the study soil, which shows a typical bimodal pore size distribution, can explain the prompt release of pre‐event water in subsurface flow. Water sources of subsurface flows at peak discharge could be affected by the antecedent soil water content, rain characteristics and antecedent groundwater levels. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
The values of parameters in a groundwater flow model govern the precision of predictions of future system behavior. Predictive precision, thus, typically depends on an ability to infer values of system properties from historical measurements through calibration. When such data are scarce, or when their information content with respect to parameters that are most relevant to predictions of interest is weak, predictive uncertainty may be high, even if the model is "calibrated." Recent advances help recognize this condition, quantitatively evaluate predictive uncertainty, and suggest a path toward improved predictive accuracy by identifying sources of predictive uncertainty and by determining what observations will most effectively reduce this uncertainty. We demonstrate linear and nonlinear predictive error/uncertainty analyses as applied to a groundwater flow model of Yucca Mountain, Nevada, the United States' proposed site for disposal of high-level radioactive waste. Linear and nonlinear uncertainty analyses are readily implemented as an adjunct to model calibration with medium to high parameterization density. Linear analysis yields contributions made by each parameter to a prediction's uncertainty and the worth of different observations, both existing and yet-to-be-gathered, toward reducing this uncertainty. Nonlinear analysis provides more accurate characterization of the uncertainty of model predictions while yielding their (approximate) probability distribution functions. This article applies the above methods to a prediction of specific discharge and confirms the uncertainty bounds on specific discharge supplied in the Yucca Mountain Project License Application.  相似文献   

18.
There has been a great deal of research interest regarding changes in flow path/runoff source with increases in catchment area. However, there have been very few quantitative studies taking subscale variability and convergence of flow path/runoff source into account, especially in relation to headwater catchments. This study was performed to elucidate how the contributions and discharge rates of subsurface water (water in the soil layer) and groundwater (water in fractured bedrock) aggregate and change with catchment area increase, and to elucidate whether the spatial variability of the discharge rate of groundwater determines the spatial variability of stream discharge or groundwater contribution. The study area was a 5‐km2 forested headwater catchment in Japan. We measured stream discharge at 113 points and water chemistry at 159 points under base flow conditions. End‐member mixing analysis was used to separate stream water into subsurface water and groundwater. The contributions of both subsurface water and groundwater had large variability below 1 km2. The contribution of subsurface water decreased markedly, while that of groundwater increased markedly, with increases in catchment area. The specific discharge of subsurface water showed a large degree of variability and decreased with catchment area below 0.1 km2, becoming almost constant above 0.1 km2. The specific discharge of groundwater showed large variability below 1 km2 and increased with catchment area. These results indicated that the variabilities of stream discharge and groundwater contribution corresponded well with the variability of the discharge rate of groundwater. However, below 0.1 km2, it was necessary to consider variations in the discharge rates of both subsurface water and groundwater. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
The yield (or discharge) of constant-speed pumps varies with the total dynamic head (or lift) against which the pump is discharging. The variation in yield over the operating range of the pump may be substantial. In groundwater simulations that are used for management evaluations or other purposes, where predictive accuracy depends on the reliability of future discharge estimates, model reliability may be enhanced by including the effects of head-capacity (or pump-capacity) relations on the discharge from the well. A relatively simple algorithm has been incorporated into the widely used MODFLOW groundwater flow model that allows a model user to specify head-capacity curves. The algorithm causes the model to automatically adjust the pumping rate each time step to account for the effect of drawdown in the cell and changing lift, and will shut the pump off if lift exceeds a critical value. The algorithm is available as part of a new multinode well package (MNW2) for MODFLOW.  相似文献   

20.
Coastal groundwater discharge (CGD) plays an important role in coastal hydrogeological systems as they are a water resource that needs to be managed, particularly in wetland areas. Despite its importance, identifying and monitoring CGD often presents physical and logistical constraints, restraining the application of more traditional submarine groundwater discharge surveying techniques. Here we investigate the capability of electrical resistivity imaging (ERI) in the Peníscola wetland (Mediterranean coast, Spain). ERI surveying made it possible to identify and delineate an ascending regional groundwater flow of thermal and Ra‐enriched groundwater converging with local flows and seawater intrusion. The continuous inputs of Ra‐rich groundwater have induced high activities of Ra isotopes and 222Rn into the marsh area, becoming among the highest previously reported in wetlands and coastal lagoons. Geoelectrical imaging enabled inferring focused upward discharging areas, leaking from the aquifer roof through a confining unit and culminating as spring pools nourishing the wetland system. Forward modelling over idealized subsurface configurations, borehole datasets, potentiometric records from standpipe piezometers, petrophysical analysis, and four natural and independent tracers (224Ra, 222Rn, temperature and salinity) permitted assessing the geoelectrical model and a derived hydrogeological pattern. The research highlights the potential of ERI to improve hydrogeological characterization of subsurface processes in complex contexts, with different converging flows. Additionally, a hydrogeological conceptual model for a groundwater‐fed coastal wetland was proposed, based on the integration of surveying datasets. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号