The elastic and inelastic seismic response of plan‐asymmetric regular multi‐storey steel‐frame buildings has been investigated under bi‐directional horizontal ground motions. Symmetric variants of these buildings were designed according to Eurocodes 3 and 8. Asymmetric buildings were created by assuming a mass eccentricity in each of the two principal directions. The torsional response in the elastic and inelastic range is qualitatively similar with the exception of the stiff edge in the strong direction of torsionally stiff buildings and the stiff edge in the weak direction of torsionally flexible buildings. The response is influenced by the intensity of ground motion, i.e. by the magnitude of plastic deformation. In the limiting case of very strong ground motion, the behaviour of initially torsionally stiff and initially torsionally flexible buildings may become qualitatively similar. A decrease in stiffness due to plastic deformations in one direction may substantially influence the behaviour in the orthogonal direction. The response strongly depends on the detailed characteristics of the ground motion. On average, torsional effects are reduced with increasing plastic deformations, unless the plastic deformations are small. Taking into account also the dispersion of results which is generally larger in the inelastic range than in the elastic one, it can be concluded that (a) the amplification of displacements determined by the elastic analysis can be used as a rough estimate also in the inelastic range and (b) any favourable torsional effect on the stiff side of torsionally stiff buildings, which may arise from elastic analysis, may disappear in the inelastic range. The conclusions are limited to fairly regular buildings and subject to further investigations. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

2.
An Erratum has been published for this article in Earthquake Engng. Struct. Dyn. 2004; 33:1429. Based on structural dynamics theory, the modal pushover analysis (MPA) procedure retains the conceptual simplicity of current procedures with invariant force distribution, now common in structural engineering practice. The MPA procedure for estimating seismic demands is extended to unsymmetric‐plan buildings. In the MPA procedure, the seismic demand due to individual terms in the modal expansion of the effective earthquake forces is determined by non‐linear static analysis using the inertia force distribution for each mode, which for unsymmetric buildings includes two lateral forces and torque at each floor level. These ‘modal’ demands due to the first few terms of the modal expansion are then combined by the CQC rule to obtain an estimate of the total seismic demand for inelastic systems. When applied to elastic systems, the MPA procedure is equivalent to standard response spectrum analysis (RSA). The MPA estimates of seismic demand for torsionally‐stiff and torsionally‐flexible unsymmetric systems are shown to be similarly accurate as they are for the symmetric building; however, the results deteriorate for a torsionally‐similarly‐stiff unsymmetric‐plan system and the ground motion considered because (a) elastic modes are strongly coupled, and (b) roof displacement is underestimated by the CQC modal combination rule (which would also limit accuracy of RSA for linearly elastic systems). Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

3.
Static torsional provisions in most seismic codes require that the lateral force at each floor level be applied at some distance from the reference centre at that floor. However, codes do not specify how to determine the locations of these centres. As a result, several different definitions of the reference centres are being used to implement the code analysis. This investigation examined how the results using various reference centres differ and which of these centres would lead to results that are in agreement with those of dynamic analysis. For this purpose three different buildings ranging form torsionally stiff to torsionally flexible were analysed. It was shown that for the class of buildings studied in this investigation that although the locations of the reference centres were quite different, the results were very similar and nearly independent of the reference centre. Comparison of results calculated from static code equivalent lateral force procedures and results from dynamic response spectrum analyses showed that the static code procedures led to design forces very close (flexible wall) or slightly conservative (stiff wall) when compared to the dynamic analysis for the torsionally stiff building. However, the static code procedures significantly underestimated the design forces of the stiff walls and significantly overestimated the design forces of the flexible walls for the torsionally flexible buildings. © 1998 John Wiley & Sons, Ltd.  相似文献   

4.
This paper evaluates the inelastic seismic response of torsionally unbalanced structural systems with strength distributed using elastic response spectrum analysis. The structural model is a single mass torsionally unbalanced system with lateral load resisting elements spanning in two principal directions. The element strength is distributed based on elastic response spectrum analysis and three different approaches to incorporate accidental torsion are considered: (a) without incorporating accidental torsion; (b) by applying static floor torques; (c) by shifting the location of the centre of mass. The seismic input is bidirectionally applied at the base of the model. It is shown that the inelastic responses depend strongly on the torsional stiffness of the system. For a torsionally stiff system, the torsional response leads to a decrease in the stiff edge displacement; however, for a torsionally flexible system, it tends to increase the stiff edge displacement. Using response spectrum analysis without including accidental torsion may lead to excessive additional ductility demand on the stiff edge element. With accidental torsion effect incorporated, the response spectrum analysis will give a strength distribution such that there will be no excessive additional ductility demands on the lateral load resisting elements.  相似文献   

5.
An attempt has been made to explore the general trends in the seismic response of plan‐asymmetric structures without any restrictions imposed by a particular code. Systems with structural elements in both orthogonal directions under bi‐directional excitation were studied. Idealized single‐storey models with bi‐axial eccentricity were employed. The systems were torsionally stiff and, in the majority of cases, mass‐eccentric. The main findings are: in general, inelastic torsional response is qualitatively similar to elastic torsional response. Quantitatively, the torsional effect on the flexible side, expressed as an increase of displacements due to torsion, decreases slightly with increasing plastic deformation, unless the plastic deformations are small. The response on the stiff side generally strongly depends on the effect of several modes of vibration and on the influence of the ground motion in the transverse direction. These influences depend on the structural and ground motion characteristics in both directions. Reduction of displacements due to torsion, typical for elastic torsionally stiff structures, usually decreases with increasing plastic deformations. As an additional effect of large plastic deformations, a flattening of the displacement envelopes in the horizontal plane usually occurs, indicating that torsional effects in the inelastic range are generally smaller than in the elastic range. The dispersion of the results of inelastic torsional response analysis is generally larger than that of elastic analysis. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

6.
The paper investigates the influence of design procedures on the seismic response of multi-storey asymmetric buildings. To this end, some structures are designed according to methods based on either static or modal analysis, with or without design eccentricities. The seismic response of these systems is determined by means of inelastic dynamic analyses and the design is thoroughly examined in order to explain the results of the dynamic analyses. Attention is basically focused on the ability of design methods to prevent asymmetric buildings from experiencing ductility demands much larger than those of the corresponding torsionally balanced systems. Numerical analyses underline that while design procedures based on either static or modal analysis are suitable for the design of torsionally rigid structures only those based on modal analysis lead to the satisfactory performance of torsionally flexible buildings. Furthermore, the study highlights the qualities of a design method proposed by the Authors. Its application does not require any explicit calculation of design eccentricities and leads to proper seismic response of both torsionally rigid and flexible asymmetric buildings.  相似文献   

7.
Estimation of peak inelastic deformation demands is a key component of any displacement-based procedure for earthquake-resistant design of new structures or for seismic evaluation of existing structures. On the basis of the results of over a thousand non-linear dynamic analyses, rules are developed for the estimation of mean and upper-characteristic peak inelastic interstorey drifts and member chord rotations in multistorey RC frame buildings, either bare or infilled in all storeys but the first. For bare frame structures, mean inelastic deformation demands can be estimated from a linear, equivalent static, or preferably multimodal response spectrum analysis with 5 per cent damping and with the RC members considered with their secant stiffness at yielding. 95 per cent characteristic values can be estimated as multiples of the mean deformations. For open-first-storey buildings, the linear analysis can be equivalent static, with the infills modelled as rigid bidiagonal struts and all RC members considered with their secant stiffness to yielding. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

8.
The increasing popularity of simplified nonlinear methods in seismic design has recently led to many proposals for procedures aimed at extending pushover analysis to plan asymmetric structures. In terms of practical applications, one particularly promising approach is based on combining pushover analysis of a 3D structural model with the results of linear (modal) dynamic analysis. The effectiveness of such procedure, however, is contingent on one fundamental requirement: the elastic prediction of the envelope of lateral displacements must be conservative with respect to the actual inelastic one. This paper aims at verifying the above assumption through an extensive parametric analysis conducted with simplified single‐storey models. The main structural parameters influencing torsional response in the elastic and inelastic range of behaviour are varied, while devoting special attention to the system stiffness eccentricity and radius. The analysis clarifies the main features of inelastic torsional response of different types of building structures; in this manner, it is found that the above‐mentioned method is generally suitable for structures characterized by moderate to large torsional stiffness, whereas it cannot be recommended for extremely torsionally stiff structures, as their inelastic torsional response almost always exceeds the elastic one. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
Seismic building codes include design provisions to account for the torsional effects arising in torsionally unbalanced (asymmetric) buildings. These provisions are based on two alternative analytical procedures for determining the design load for the individual resisting structural elements. A previous study has shown that the linear elastic modal analysis procedure may not lead to conservative designs, even for multistorey buildings with regular asymmetry, when such structures are excited well into the inelastic range of response. The equivalent static force procedure as recommended by codes may also be deficient in accounting for additional ductility demand in the critical stiff-edge elements. This paper addresses the non-conservatism of existing static torsional provisions and examines aspects of element strength distribution and its influence on inelastic torsional effects. A recommendation is made for improving the effectiveness of the code-type static force procedure for torsionally unbalanced multistorey frame buildings with regular asymmetry, leading to a design approach which estimates conservatively the peak ductility demand of edge elements on both sides of the building. The modified approach also retains the simplicity of existing code provisions and results in acceptable levels of additional lateral design strength. It has recently been adopted by the new Australian earthquake code, which is due to be implemented early in 1993.  相似文献   

10.
Two one‐way eccentric, two‐storey, one‐by‐one‐bay reinforced concrete (RC) structures are pseudodynamically tested under unidirectional ground motions. Theoretical considerations about the effect of torsional coupling on modal periods and shapes agree with modal results of the test structure, considering member stiffness is equal to the secant stiffness to yielding in skew‐symmetric bending. Modal periods of such an elastic structure are in fair agreement with effective periods inferred from the measured response at the beginning of a test of a thoroughly cracked structure and at the end of the test. A time‐varying stiffness matrix and a non‐proportional damping matrix fitted to the test results may be used to reproduce the measured response approximately by modal superposition and identify the role of the four time‐varying modes. Flexible side columns sustained very large drift demands simultaneously in the two transverse directions and suffered significant but not heavy, damage at lap‐splices. RC‐jacketing of the flexible side columns practically eliminated the static eccentricity between the floor centres of twist and mass as well as the torsional response. Inelastic time‐history analysis with point‐hinge member models, using as elastic stiffness the secant stiffness to yielding and neglecting post‐ultimate‐strength cyclic degradation of resistance in members with plain bars and poor detailing, predicted fairly well the response until the peak displacements and member deformations occurred. After that, it underestimated displacement peaks and the lengthening of the apparent period and missed the gradual drifting of the response towards a permanent offset. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
In this study, the torsional response of buildings with peripheral steel‐braced frame lateral systems is evaluated. A three‐dimensional model of a three story braced frame with various levels of eccentricity is created and the effects of torsion on the seismic response is assessed for four hazard levels. The response history analysis results indicate that, unlike frame structures, the torsional amplifications in the inelastic systems exceed those of corresponding elastic systems and tend to increase with an increase in the level of inelasticity. The ability of two simplified procedures, elastic response spectrum analysis and pushover analysis, to capture the torsional amplifications in steel‐braced frames is evaluated. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
This paper aims to extend the consecutive modal pushover (CMP) procedure for estimating the seismic demands of two-way unsymmetric-plan tall buildings subjected to bi-directional seismic ground motions taking the effects of higher modes and torsion into account. Multi-stage and single-stage pushover analyses are carried out in both X and Y directions. Inelastic seismic responses obtained by multi-stage and single-stage pushover analyses for X and Y directions are combined using the SRSS combination scheme. The final seismic responses are determined by enveloping the combined results of multi-stage and single-stage pushover analyses. To evaluate the accuracy of the proposed procedure, it is applied to two-way unsymmetric-plan tall buildings which include torsionally stiff and torsionally flexible systems. The results derived from the CMP procedure are compared with those from nonlinear response history analysis (NL-RHA), as a benchmark solution. Moreover, the advantages of the proposed procedure are demonstrated by comparing the results derived from the CMP to those from pushover analysis with uniform and fundamental effective mode distributions. The proposed procedure is able to accurately predict amplification or de-amplification of the seismic displacements at the flexible and stiff edges of the two-way unsymmetric-plan tall buildings by considering the effects of higher modes and torsion. The extended CMP procedure can accurately estimate the peak inelastic responses, such as displacements and storey drifts. The CMP procedure features a higher potential in estimating plastic hinge rotations at both flexible and stiff sides of unsymmetric-plan tall buildings under bi-directional seismic excitation when compared to the uniform and fundamental effective mode force distributions.  相似文献   

13.
The accuracy of the three‐dimensional modal pushover analysis (MPA) procedure in estimating seismic demands for unsymmetric‐plan buildings due to two horizontal components of ground motion, simultaneously, is evaluated. Eight low‐and medium‐rise structures were considered. Four intended to represent older buildings were designed according to the 1985 Uniform Building Code, whereas four other designs intended to represent newer buildings were based on the 2006 International Building Code. The median seismic demands for these buildings to 39 two‐component ground motions, scaled to two intensity levels, were computed by MPA and nonlinear response history analysis (RHA), and then compared. Even for these ground motions that deform the buildings significantly into the inelastic range, MPA offers sufficient degree of accuracy. It is demonstrated that PMPA, a variant of the MPA procedure, for nonlinear systems is almost as accurate as the well‐known standard response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative to nonlinear RHA, whereby seismic demands can be estimated directly from the (elastic) design spectrum. In contrast, the nonlinear static procedure specified in the ASCE/SEI 41‐06 Standard is demonstrated to grossly underestimate seismic demands for some of the unsymmetric‐plan buildings considered. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
Recently, a design modification has been proposed for eccentric, torsionally stiff, braced steel buildings, designed according to the current Eurocodes 3 and 8, that improves noticeably their inelastic response under the action of design level earthquakes. The improvement consists in a more uniform distribution of ductility demands throughout the building. In the present paper, a similar, though differently derived, modification is applied to torsionally flexible eccentric buildings and their response is again evaluated under pairs of design earthquake motions. A substantial improvement of their inelastic response is also observed, similar to what had been obtained for torsionally stiff buildings. The new approach is also tested with torsionally stiff buildings and leads to similarly satisfactory results. Thus it may be recommended for general application.  相似文献   

15.
A statistical analysis of the peak acceleration demands for nonstructural components (NSCs) supported on a variety of stiff and flexible inelastic regular moment‐resisting frame structures with periods from 0.3 to 3.0 s exposed to 40 far‐field ground motions is presented. Peak component acceleration (PCA) demands were quantified based on the floor response spectrum (FRS) method without considering dynamic interaction effects. This study evaluated the main factors that influence the amplification or decrease of FRS values caused by inelasticity in the primary structure in three distinct spectral regions namely long‐period, fundamental‐period, and short‐period region. The amplification or decrease of peak elastic acceleration demands depends on the location of the NSC in the supporting structure, periods of the component and building, damping ratio of the component, and level of inelasticity of the supporting structure. While FRS values at the initial modal periods of the supporting structure are reduced due to inelastic action in the primary structure, the region between the modal periods experiences an increase in PCA demands. A parameter denoted as acceleration response modification factor (Racc) was proposed to quantify this reduction/increase in PCA demands. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

16.
This investigation deals with the torsional balance of the earthquake response and design of elastic asymmetric structures with frictional dampers. Plan asymmetry leads to an uneven lateral deformation demand among structural members and to unbalanced designs with larger capacities in some resisting planes. Frictional dampers are capable of controlling lateral‐torsional coupling by placing the so‐called empirical center of balance (ECB) of the structure at equal distance from all edges of the building. This rule is developed for single‐story systems with linear and inelastic behavior. However, recently obtained theoretical and experimental results demonstrate that this rule carries over to multistory structures. Results show that the peak displacement demand at the building edges and that of resisting planes equidistant from the geometric center may be similar if the damper is optimally placed. It is also shown that torsional amplification of the edge displacements of arbitrary asymmetric structures relative to the displacement of the symmetric counterparts are approximately bound by a factor of 2. Furthermore, frictional dampers are equally effective in controlling lateral‐torsional coupling of torsionally flexible as well as stiff structures. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

17.
Based on an asymmetric multistorey frame building model, this paper investigates the influence of a building's higher vibration modes on its inelastic torsional response and evaluates the adequacy of the provisions of current seismic building codes and the modal analysis procedure in accounting for increased ductility demand in frames situated at or near the stiff edge of such buildings. It is concluded that the influence of higher vibration modes on the response of the upper-storey columns of stiff-edge frames increases significantly with the building's fundamental uncoupled lateral period and the magnitude of the stiffness eccentricity. The application of the equivalent static torsional provisions of certain building codes may lead to non-conservative estimates of the peak ductility demand, particularly for structures with large stiffness eccentricity. In these cases, the critical elements are vulnerable to excessive additional ductility demand and, hence, may be subject to significantly more severe structural damage than in corresponding symmetric buildings. It is found that regularly asymmetric buildings excited well into the inelastic range may not be conservatively designed using linear elastic modal analysis theory. Particular caution is required when applying this method to the design of stiff-edge frame elements in highly asymmetric structures.  相似文献   

18.
The elastic torsional stiffness of a structure has important influence on the seismic response of an asymmetric structure, both in the elastic and inelastic range. For elastic structures it is immaterial whether the stiffness is provided solely by structural elements in planes parallel to the direction of earthquake or by a combination of such elements in parallel and orthogonal planes. The issue of how the relative contribution of structural elements in orthogonal planes affects the torsional response of inelastic structures has been the subject of continuing study. Several researchers have noted that structural elements in orthogonal planes reduce the ductility demands in both the flexible and stiff edge elements parallel to the earthquake. Some have noted that the beneficial effect of structural elements in orthogonal planes is more pronounced when such elements remain elastic. These issues are further examined in this paper through analytical studies on the torsional response of single-storey building models. It is shown that, contrary to the findings of some previous studies, the torsional response of inelastic structures is affected primarily by the total torsional stiffness in the elastic range, and not so much by whether such stiffness is contributed solely by structural elements in parallel planes or by such elements in both parallel and orthogonal planes. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

19.
A suite of reinforced‐concrete frame buildings located on hill sides, with 2 different structural configurations, viz step‐back and split‐foundation, are analyzed to study their floor response. Both step‐back and split‐foundation structural configurations lead to torsional effects in the direction across the slope due to the presence of shorter columns on the uphill side. Peak floor acceleration and floor response spectra are obtained at each storey's center of rigidity and at both its stiff and flexible edges. As reported in previous studies as well, it is observed that the floor response spectra are better correlated with the ground response spectrum. Therefore, the floor spectral amplification functions are obtained as the ratio of spectral ordinates at different floor levels to the one at the ground level. Peaks are observed in the spectral amplification functions corresponding to the first 2 modes in the upper portion of the hill‐side buildings, whereas a single peak corresponding to a specific kth mode of vibration is observed on the floors below the uppermost foundation level. Based on the numerical study for the step‐back and split‐foundation hill‐side buildings, simple floor spectral amplification functions are proposed and validated. The proposed spectral amplification functions take into account both the buildings' plan and elevation irregularities and can be used for seismic design of acceleration‐sensitive nonstructural components, given that the supporting structure's dynamic characteristics, torsional rotation, ground‐motion response spectrum, and location of the nonstructural components within the supporting structure are known, because current code models are actually not applicable to hill‐side buildings.  相似文献   

20.
This paper proposes bi‐directional coupled tuned mass dampers (BiCTMDs) for the seismic response control of two‐way asymmetric‐plan buildings subjected to bi‐directional ground motions. The proposed BiCTMD was developed from the three‐degree‐of‐freedom modal system, which represents the vibration mode of a two‐way asymmetric‐plan building. The performance of the proposed BiCTMD for the seismic response control of elastic two‐way asymmetric‐plan buildings was verified by investigating the reductions of the amplitudes of the associated frequency response functions. In addition, the investigation showed that the proposed BiCTMD is effective in reducing the seismic damage of inelastic asymmetric‐plan buildings. Therefore, the BiCTMD is an effective approach for the seismic response control of both elastic and inelastic two‐way asymmetric‐plan buildings. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   