首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper reviews the theoretical principles of subspace system identification as applied to the problem of estimating black‐box state‐space models of support‐excited structures (e.g., structures exposed to earthquakes). The work distinguishes itself from past studies by providing readers with a powerful geometric interpretation of subspace operations that relates directly to theoretical structural dynamics. To validate the performance of subspace system identification, a series of experiments are conducted on a multistory steel frame structure exposed to moderate seismic ground motions; structural response data is used off‐line to estimate black‐box state‐space models. Ground motions and structural response measurements are used by the subspace system identification method to derive a complete input–output state‐space model of the steel frame system. The modal parameters of the structure are extracted from the estimated input–output state‐space model. With the use of only structural response data, output‐only state‐space models of the system are also estimated by subspace system identification. The paper concludes with a comparison study of the modal parameters extracted from the input–output and output‐only state‐space models in order to quantify the uncertainties present in modal parameters extracted from output‐only models. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
Although structural mechanical impedance is a direct representation of the structural parameters, its measurement is difficult at high frequencies owing to practical considerations. This paper presents a new method of damage diagnosis by means of changes in the structural mechanical impedance at high frequencies. The mechanical impedance is extracted from the electro‐mechanical admittance signatures of piezoelectric‐ceramic (PZT) patches surface bonded to the structure using the electro‐mechanical impedance (EMI) technique. The main feature of the newly developed approach is that both the real as well as the imaginary component of the admittance signature is used in damage quantification. A complex damage metric is proposed to quantify damage parametrically based on the extracted structural parameters, i.e. the equivalent single degree of freedom (SDOF) stiffness, the mass, and the damping associated with the drive point of the PZT patch. The proposed scheme eliminates the need for any a priori information about the phenomenological nature of the structure or any ‘model’ of the structural system. As proof of concept, the paper reports a damage diagnosis study conducted on a model reinforced concrete (RC) frame subjected to base vibrations on a shaking table. The proposed methodology was found to perform better than the existing damage quantification approaches, i.e. the low‐frequency vibration methods as well as the traditional raw‐signature based damage quantification in the EMI technique. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
The viability of a complete structural characterization of civil structures is explored and discussed. In particular, the identification of modal (i.e. natural frequencies, damping ratios and modal shapes) and physical properties (i.e. mass and stiffness) using only the structure’s free decay response is studied. To accomplish this, modal analysis from free vibration response only (MAFVRO) and mass modification (MM) methodologies are engaged along with Wavelet based techniques for optimal signal processing and modal reconstruction. The methodologies are evaluated using simulated and experimental data. The simulated data are extracted from a simple elastic model of a 5 story shear building and from a more realistic nonlinear model of a RC frame structure. The experimental data are gathered from shake table test of a 2-story scaled shear building. Guidelines for the reconstruction procedure from the data are proposed as the quality of the identified properties is shown to be governed by adequate selection of the frequency bands and optimal modal shape reconstruction. Moreover, in cases where the structure has undergone damage, the proposed identification scheme can also be applied for preliminary assessment of structural health.  相似文献   

4.
In the inelastic time history analyses of structures in seismic motion, part of the seismic energy that is imparted to the structure is absorbed by the inelastic structural model, and Rayleigh damping is commonly used in practice as an additional energy dissipation source. It has been acknowledged that Rayleigh damping models lack physical consistency and that, in turn, it must be carefully used to avoid encountering unintended consequences as the appearance of artificial damping. There are concerns raised by the mass proportional part of Rayleigh damping, but they are not considered in this paper. As far as the stiffness proportional part of Rayleigh damping is concerned, either the initial structural stiffness or the updated tangent stiffness can be used. The objective of this paper is to provide a comprehensive comparison of these two types of Rayleigh damping models so that a practitioner (i) can objectively choose the type of Rayleigh damping model that best fits her/his needs and (ii) is provided with useful analytical tools to design Rayleigh damping model with good control on the damping ratios throughout inelastic analysis. To that end, a review of the literature dedicated to Rayleigh damping within these last two decades is first presented; then, practical tools to control the modal damping ratios throughout the time history analysis are developed; a simple example is finally used to illustrate the differences resulting from the use of either initial or tangent stiffness‐based Rayleigh damping model. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A structure's health or level of damage can be monitored by identifying changes in structural or modal parameters. This research directly identifies changes in structural stiffness due to modelling error or damage for a post‐tensioned pre‐cast reinforced concrete frame building with rocking beam column connections and added damping and stiffness (ADAS) elements. A structural health monitoring (SHM) method based on adaptive least mean squares (LMS) filtering theory is presented that identifies changes from a simple baseline model of the structure. This method is able to track changes in the stiffness matrix, identifying when the building is (1) rocking, (2) moving in a hybrid rocking–elastic regime, or (3) responding linearly. Results are compared for two different LMS‐based SHM methods using an L 2 error norm metric. In addition, two baseline models of the structure, one using tangential stiffness and the second a more accurate bi‐linear stiffness model, are employed. The impact of baseline model complexity is then delineated. The LMS‐based methods are able to track the non‐linearity of the system to within 15% using this metric, with the error due primarily to filter convergence rates as the structural response changes regimes while undergoing the El Centro ground motion record. The use of a bi‐linear baseline model for the SHM problem is shown to result in error metrics that are at least 50% lower than those for the tangential baseline model. Errors of 5–15% with this L 2 error norm are fairly stringent compared to the greater than 2 × changes in stiffness undergone by the structure, however, in practice the usefulness of the results is dependent on the resolution required by the user. The impact of sampling rate is shown to be negligible over the range of 200–1000Hz, along with the choice of LMS‐based SHM method. The choice of baseline model and its level of knowledge about the actual structure is seen to be the dominant factor in achieving good results. The methods presented require 2.8–14.0 Mcycles of computation and therefore could easily be implemented in real time. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

6.
Shaking‐table data for a tuned liquid damper with a sloped bottom of 30° with the horizontal are investigated using a non‐linear numerical model previously developed by Yu, Jin‐kyu, Nonlinear characteristics of tuned liquid dampers. Ph.D. Thesis, Department of Civil Engineering, University of Washington, Seattle, WA, 98195 (1997). Stiffness and damping parameters for this model are obtained and compared with those previously derived for box‐shaped tanks. The values for these parameters reflect the softening spring behaviour of the sloped‐bottom system in contrast to the hardening system evident for the box‐shaped TLD. Consequently, the sloped‐bottom tank should be tuned slightly higher than the fundamental structural frequency in order to obtain the most effective damping. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

7.
Substructure hybrid simulation has been actively investigated and applied to evaluate the seismic performance of structural systems in recent years. The method allows simulation of structures by representing critical components with physically tested specimens and the rest of the structure with numerical models. However, the number of physical specimens is limited by available experimental equipment. Hence, the benefit of the hybrid simulation diminishes when only a few components in a large system can be realistically represented. The objective of the paper is to overcome the limitation through a novel model updating method. The model updating is carried out by applying calibrated weighting factors at each time step to the alternative numerical models, which encompasses the possible variation in the experimental specimen properties. The concept is proposed and implemented in the hybrid simulation framework, UI‐SimCor. Numerical verification is carried out using two‐DOF systems. The method is also applied to an experimental testing, which proves the concept of the proposed model updating method. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
In this study, we determine an updated finite element model of a reinforced concrete building—which was damaged from shaking during 1994 Northridge earthquake—using forced‐vibration test data and a novel model‐updating technique. Developed and verified in the companion paper (viz. BVLSrc, Earthquake Eng. Struct. Dyn. 2006; this issue), this iterative technique incorporates novel sensitivity‐based relative constraints to avoid ill conditioning that results from spatial incompleteness of measured data. We used frequency response functions and natural frequencies as input for the model‐updating problem. These data were extracted from measurements obtained during a white‐noise excitation applied at the roof of the building using a linear inertial shaker. Flexural stiffness values of properly grouped structural members, modal damping ratios, and translational and rotational mass values were chosen as the updating parameters, so that the converged results had direct physical interpretations, and thus, comparisons with common parameters used in seismic design and evaluation of buildings could be made. We investigated the veracity of the updated finite element model by comparing the predicted and measured dynamic responses under a second, and different type of forced (sine‐sweep) vibration, test. These results indicate that the updated model replicates the dynamic behaviour of the building reasonably well. Furthermore, the updated stiffness factors appear to be well correlated with the observed building damage patterns (i.e. their location and severity). Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

10.
This paper verifies the feasibility of the proposed system identification methods by utilizing shaking table tests of a full‐scale four‐story steel building at E‐Defense in Japan. The natural frequencies, damping ratios and modal shapes are evaluated by single‐input‐four‐output ARX models. These modal parameters are prepared to identify the mass, damping and stiffness matrices when the objective structure is modelled as a four degrees of freedom (4DOF) linear shear building in each horizontal direction. The nonlinearity in stiffness is expressed as a Bouc–Wen hysteretic system when it is modelled as a 4DOF nonlinear shear building. The identified hysteretic curves of all stories are compared to the corresponding experimental results. The simple damage detection is implemented using single‐input‐single‐output ARX models, which require only two measurements in each horizontal direction. The modal parameters are equivalent‐linearly evaluated by the recursive Least Squares Method with a forgetting factor. When the structure is damaged, its natural frequencies decrease, and the corresponding damping ratios increase. The fluctuation of the identified modal properties is the indirect information for damage detection of the structure. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
This paper presents a method for evaluating the residual structural capacity of earthquake‐affected steel structures. The method first quantifies the damage severity of a beam by computing the dynamic‐strain‐based damage index. Next, the model used to analyze the structure is updated based on the damage index, to reflect the observed damage conditions. The residual structural capacity is then estimated in terms of changes in stiffness and strength, which can be applied by structural engineers, via a nonlinear static analysis of the updated model. The main contributions of this paper are in performance evaluation of the dynamic‐strain‐based damage index for seismically induced damage using a newly developed substructure testing environment, consideration of various damage patterns in composite beams, and extension of a local damage evaluation technique to a residual capacity estimation procedure by incorporating the model‐updating technique. In laboratory testing, the specimens were damaged quasi‐statically, and vibration tests were conducted as the damage proceeded. First, a bare steel beam–column connection was tested, and then a similar one with a floor slab was used for a more realistic case. The estimated residual structural capacities for these specimens were compared with the static test results. The results verified that the proposed method can provide fine estimates of the stiffness and strength deteriorations within 10% for the specimen without the floor slab and within 30% for that with the floor slab. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

12.
Structural identification based on measured dynamic data is formulated in a multi‐objective context that allows the simultaneous minimization of the various objectives related to the fit between measured and model predicted data. Thus, the need for using arbitrary weighting factors for weighting the relative importance of each objective is eliminated. For conflicting objectives there is no longer one solution but rather a whole set of acceptable compromise solutions, known as Pareto solutions, which are optimal in the sense that they cannot be improved in any objective without causing degradation in at least one other objective. The strength Pareto evolutionary algorithm is used to estimate the set of Pareto optimal structural models and the corresponding Pareto front. The multi‐objective structural identification framework is presented for linear models and measured data consisting of modal frequencies and modeshapes. The applicability of the framework to non‐linear model identification is also addressed. The framework is illustrated by identifying the Pareto optimal models for a scaled laboratory building structure using experimentally obtained modal data. A large variability in the Pareto optimal structural models is observed. It is demonstrated that the structural reliability predictions computed from the identified Pareto optimal models may vary considerably. The proposed methodology can be used to explore the variability in such predictions and provide updated structural safety assessments, taking into consideration all Pareto structural models that are consistent with the measured data. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

13.
It has been shown that the operator‐splitting method (OSM) provides explicit and unconditionally stable solutions for quasi‐static pseudo‐dynamic substructure testing. However, the OSM provides only an explicit target displacement but not an explicit target velocity, so that it is essentially an implicit method for real‐time substructure testing (RST) when the velocity‐dependent restoring force is considered. This paper proposes a target velocity formulation based on the forward difference of the predicted displacements so as to render the OSM explicit for RST. The stability and accuracy of the resulting OSM‐RST algorithm are investigated. It is shown that the OSM‐RST is unconditionally stable so long as the non‐linear stiffness and damping are of the softening type (i.e. the tangent stiffness and damping never exceed the initial values). The stability of the OSM‐RST for structures with infinite tangent damping coefficient or stiffness is also proved, and the stability of the method for MDOF structures with a non‐classical damping matrix is demonstrated by an energy criterion. The effects of actuator delay and compensation are analysed based on the bilinear approximation of the actuator step response. Experiments on damped SDOF and MDOF structures verify that the stability of the OSM‐RST is preserved when the experimental substructure generates velocity‐dependent reaction forces, whereas the stability of real‐time substructure tests based on the central difference method is worsened by the damping of the specimen. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Properly fabricated triangular‐plate added damping and stiffness (TADAS) devices can sustain a large number of yield reversals without strength degradation, thereby dissipating a significant amount of earthquake‐induced energy. A pronounced isotropic‐hardening effect is recognized in the force‐deformation relationships of the TADAS devices made from two grades of low yield strength steel. The proposed plasticity‐fibre model employing two surfaces (a yield surface and a bounding surface) in plasticity theory accurately predicts the experimental responses of the TADAS devices. This model is also implemented into a computer program DRAIN2D+ to investigate a frame response with the TADAS devices. Substructure pseudo‐dynamic tests and analytical studies of a two‐storey steel frame constructed with the low yield strength steel, LYP‐100 or LYP‐235 grade, TADAS devices confirm that the dynamic structural response can only be predicted if the proposed plasticity‐fibre model is used for LYP‐100 steel TADAS device. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

16.
This paper discusses how to use the three‐dimensional (3D) time‐domain finite‐element method incorporating the least‐squares method to calculate the equivalent foundation mass, damping and stiffness matrices. Numerical simulations indicate that the accuracy of these equivalent matrices is acceptable when the applied harmonic force of 1+sine is used. Moreover, the accuracy of the least‐squares method using the 1+sine force is not sensitive to the first time step for inclusion of data. Since the finite‐element method can model problems flexibly, the equivalent mass, damping and stiffness matrices of very complicated soil profiles and foundations can be established without difficulty using this least‐squares method. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

17.
In real‐time hybrid simulations (RTHS) that utilize explicit integration algorithms, the inherent damping in the analytical substructure is generally defined using mass and initial stiffness proportional damping. This type of damping model is known to produce inaccurate results when the structure undergoes significant inelastic deformations. To alleviate the problem, a form of a nonproportional damping model often used in numerical simulations involving implicit integration algorithms can be considered. This type of damping model, however, when used with explicit integration algorithms can require a small time step to achieve the desired accuracy in an RTHS involving a structure with a large number of degrees of freedom. Restrictions on the minimum time step exist in an RTHS that are associated with the computational demand. Integrating the equations of motion for an RTHS with too large of a time step can result in spurious high‐frequency oscillations in the member forces for elements of the structural model that undergo inelastic deformations. The problem is circumvented by introducing the parametrically controllable numerical energy dissipation available in the recently developed unconditionally stable explicit KR‐α method. This paper reviews the formulation of the KR‐α method and presents an efficient implementation for RTHS. Using the method, RTHS of a three‐story 0.6‐scale prototype steel building with nonlinear elastomeric dampers are conducted with a ground motion scaled to the design basis and maximum considered earthquake hazard levels. The results show that controllable numerical energy dissipation can significantly eliminate spurious participation of higher modes and produce exceptional RTHS results. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Structural damage assessment under external loading, such as earthquake excitation, is an important issue in structural safety evaluation. In this regard, appropriate data analysis and feature extraction techniques are required to interpret the measured data and to identify the state of the structure and, if possible, to detect the damage. In this study, the recursive subspace identification with Bona‐fide LQ renewing algorithm (RSI‐BonaFide‐Oblique) incorporated with moving window technique is utilized to identify modal parameters such as natural frequencies, damping ratios, and mode shapes at each instant of time during the strong earthquake excitation. From which the least square stiffness method (LSSM) combined with the model updating technique, called efficient model correction method (EMCM), is used to estimate the first‐stage system stiffness matrix using the simplified model from the previously identified modal parameters (nominal model). In the second stage, 2 different damage assessment algorithms related to the nominal system stiffness matrix were derived. First, the model updating technique, called EMCM, is applied to correct the nominal model by the newly identified modal parameters during the strong motion. Second, the element damage index can be calculated using element damage index method (EDIM) to quantify the damage extent in each element. Verification of the proposed methods through the shaking table test data of 2 different types of structures and a building earthquake response data is demonstrated to specify its corresponding damage location, the time of occurrence during the excitation, and the percentage of stiffness reduction.  相似文献   

19.
The flow patterns in confluence channel and the simulation of confluence flow are more complex than that in straight channel. Additional terms in the momentum equations, i.e. dissipation terms, denoting the impact of turbulence, and dispersion terms, denoting the vertical non‐uniformity of velocity, show great impacts on the accuracy of numerical simulations. The dissipation terms, i.e. the product of eddy viscosity coefficient and velocity gradient, are much larger than those of the flow in straight channel. In this study, the zero equation model and the depth‐averaged k‐ε model are used to analyse the impact of eddy viscosity. Meanwhile, the dispersion terms in the momentum equation, depending on the vertical non‐uniformity of velocity, are usually neglected in routine simulation. With the use of detailed experimental data for verification, this study presents the distribution of parameters of vertical non‐uniformity and the intimated connection between non‐uniformity parameters and accuracy of numerical simulations of confluence flow with depth‐averaged models. The results present that simulation accuracy of confluence flow is very sensitive to the turbulence modes, which cannot be handled by normal, simple turbulence model. On the contrary, the impact of dispersion terms is both flow‐condition‐dependent and place‐dependent, and such impact is negligible when secondary circulation is weak. The results indicate the key elements in modelling confluence flow and are helpful for selecting suitable numerical model and solving engineering problems encountered in confluence channel. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
With the launch of the high‐speed train project in California, the seismic risk is a crucial concern to the stakeholders. To investigate the seismic behavior of future California High‐Speed Rail (CHSR) bridge structures, a 3D nonlinear finite‐element model of a CHSR prototype bridge is developed. Soil‐structure and track‐structure interactions are accounted for in this comprehensive numerical model used to simulate the seismic response of the bridge and track system. This paper focuses on examining potential benefits and possible drawbacks of the a priori promising application of seismic isolation in CHSR bridges. Nonlinear time history analyses are performed for this prototype bridge subjected to two bidirectional horizontal historical earthquake ground motions each scaled to two different seismic hazard levels. The effect of seismic isolation on the seismic performance of the bridge is investigated through a detailed comparison of the seismic response of the bridge with and without seismic isolation. It is found that seismic isolation significantly reduces the deck acceleration and the force demand in the bridge substructure (i.e., piers and foundations), especially for high‐intensity earthquakes. However, seismic isolation increases the deck displacement (relative to the pile cap) and the stresses in the rails. These findings imply that seismic isolation can be promisingly applied to CHSR bridges with due consideration of balancing its beneficial and detrimental effects through using appropriate isolators design. The optimum seismic isolator properties can be sought by solving a performance‐based optimum seismic design problem using the nonlinear finite‐element model presented herein. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号