首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For the public welfare and safety, buildings such as hospitals, industrial facilities, and technology centers need to remain functional at all times; even during and after major earthquakes. The values of these buildings themselves may be insignificant when compared to the cost of loss of operations and business continuity. Seismic isolation aims to protect both the integrity and the contents of a structure. Since the tolerable acceleration levels are relatively low for continued services of vibration-sensitive high-tech contents, a better understanding of acceleration response behaviors of seismically isolated buildings is necessary. In an effort to shed light to this issue, following are investigated via bi-directional time history analyses of seismically isolated benchmark buildings subject to historical earthquakes: (i) the distribution of peak floor accelerations of seismically isolated buildings subject to seismic excitations in order to find out which floors are likely to sustain the largest accelerations; (ii) the influence of equivalent linear modeling of isolation systems on the floor accelerations in order to find out the range of possible errors introduced by this type of modeling; (iii) the role of superstructure damping in reducing floor accelerations of seismically isolated buildings with flexible superstructures in order to find out whether increasing the superstructure damping helps reducing floor accelerations notably. Influences of isolation system characteristics and superstructure flexibility are both taken into account.  相似文献   

2.
An analytical study of the seismic response of typical base isolated structures mounted on rubber bearings is presented. Isolated buildings are liable to have closely spaced lower modes of vibration with small eccentricity between centres of mass and rigidity. The isolated structure is modelled as a rigid deck with lumped masses supported on axially inextensible elastomeric rubber bearings. This simplified system has three degrees of freedom (dof), two translations and one rotation in the horizontal plane. The Green's functions for the displacement response of the 3 dof system are derived for both undamped and damped cases with small and large eccentricities. The small eccentricity case is taken from a specific isolated building, while the large eccentricity case arises from the 5 per cent accidental eccentricity which is required by various seismic codes. An interaction equation for normalized displacements is established for an idealized flat velocity spectrum or hyperbolic acceleration spectrum. An isolated building on rubber bearings would have its fundamental period fall into this range of a design spectrum. Numerical results for the specific building subjected to the El Centro earthquake of 1940 are presented. Both the time history and the response spectrum modal superposition analysis were performed. In the response spectrum analysis, the Complete Quadratic Combination (CQC) showed superiority over the Square Root of the Sum of Squares (SRSS) in estimating maximum responses. It is concluded that the effect of torsional coupling on the transient response of base isolated structures is insignificant, due to the combined effect of the time lag between the maximum translational and torsional responses and the influence of damping in the isolation system which for elastomeric bearings can be as high as 8 to 10 per cent.  相似文献   

3.
Numerical simulations and parametric studies have been used to investigate the influence of potential poundings of seismically isolated buildings with adjacent structures on the effectiveness of seismic isolation. Poundings are assumed to occur at the isolation level between the seismically isolated building and the surrounding moat wall. After assessing some common force‐based impact models, a variation of the linear viscoelastic impact model is proposed to avoid tensile impact forces during detachment, while enabling the consideration of permanent plastic deformations at the vicinity of the impact. A large number of numerical simulations of seismically isolated buildings with different characteristics have been conducted under six earthquake excitations in order to investigate the influence of various design parameters and conditions on the peak floor accelerations and interstorey deflections during poundings. The numerical simulations demonstrate that poundings may substantially increase floor accelerations, especially t the base floor where impacts occur. Higher modes of vibration are excided during poundings, increasing the interstorey deflections, instead of retaining an almost rigid‐body motion of the superstructure, which is aimed with seismic isolation. Impact stiffness seems to affect significantly the acceleration response at the isolation level, while the displacement response is more insensitive to the variation of the impact stiffness. Finally, the results indicate that providing excessive flexibility at the isolation system to minimize the floor accelerations may lead to a building vulnerable to poundings, if the available seismic gap is limited. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
The Building Standard Law of Japan and related Enforcement Order and Notifications have been substantially revised since the year 2000 to introduce a performance-based regulatory and deregulation system for building control systems. Up to then, time-history analyses were mandatory for isolated buildings and had to be specially approved by the Minster of the Ministry of Construction (MOC). Simplified design procedures based on the equivalent linear method for seismically isolated buildings have been issued as “Notification 2009 — Structural calculation procedure for buildings with seismic isolation” from MOC, and are now integrated into the Ministry of Land, Infrastructure, and Transportation (MLIT). Along with Notification 2009, “Notification 1446 of year 2000 — Standard for specifications and test methods for seismic isolation devices” was also issued. Buildings with heights equal to or less than 60m and that are designed according to these Notifications, including base isolated buildings, only need approval from local building officials, and no longer require the special approval of the Minister of MLIT. This paper summarizes: 1) some statistics related to buildings with seismic isolation completed up to the end of 2001; 2) simplified design procedures required by Notification 2009 of year 2000; and 3) performance of seismic isolation devices required by Notification 1446 of year 2000.  相似文献   

6.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
The complexity of modern seismically isolated structures requires the analysis of the structural system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware.In this paper,an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift.T...  相似文献   

8.
The complexity of modern seismically isolated structures requires the analysis of the structural system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware. In this paper, an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift. The computational model has the capability of modeling various types of isolation devices with strong nonlinearities, analyzing multiple superstructures (up to five separate superstructures) on multiple bases (up to five bases), and capturing the effects of lateral loads on bearing axial forces, including bearing uplift. The model developed herein has been utilized to form the software platform 3D-BASIS-ME-MB, which provides the practicing engineering community with a versatile tool for analysis and design of complex structures with modern isolation systems.  相似文献   

9.
The aim of this paper is to evaluate the effectiveness of a concave sliding bearing system for the seismic protection of liquefied gas storage tanks through a seismic fragility analysis. An emblematic case study of elevated steel storage tanks, which collapsed during the 1999 ?zmit earthquake at Habas Pharmaceutics plant in Turkey, is studied. Firstly, a fragility analysis is conducted for the examined tank based on a lumped-mass stick model, where the nonlinear shear behaviour of support columns is taken into account by using a phenomenological model. Fragility curves in terms of an efficient intensity measure for different failure modes of structural components demonstrate the inevitable collapse of the tank mainly due to insufficient shear strength of the support columns. A seismic isolation system based on concave sliding bearings, which has been demonstrated a superior solution to seismically protect elevated tanks, is then designed and introduced into the numerical model, accounting for its non-linear behaviour. Finally, a vulnerability analysis for the isolated tank is performed, which proves a high effectiveness of the isolation system in reducing the probability of failure within an expected range of earthquake intensity levels.  相似文献   

10.
The report summarizes the observed damage to a variety of buildings near the epicenter of the M6.8 Luding earthquake in Sichuan Province, China. They include base-isolated buildings, multi-story reinforced concrete (RC) frame buildings, and masonry buildings. The near-field region is known to be tectonically highly active, and the local intensity level is the highest, that is, 0.4g peak ground acceleration (PGA) for the design basis earthquake, in the Chinese zonation of seismic ground motion parameters. The extent of damage ranged from the weak-story collapse that claimed lives to the extensive nonstructural damage that suspended occupancy. The report highlights the first observation of the destruction of rubber bearings and viscous dampers in the isolation layer of Chinese seismically isolated buildings. It also features the rare observation of the brittle shear failure of RC columns in moment-resisting frames in a region of such a high seismic design requirement. Possible reasons that may have attributed to the reported damage are suggested by providing facts observed in the field. However, careful forensic analyses are needed before any conclusive judgment can be made.  相似文献   

11.
12.
This paper presents selected indicative results from an extensive parametric investigation that has been performed in order to assess the effects of potential earthquake‐induced poundings on the overall dynamic response of seismically isolated buildings. In particular, a seismically isolated building and its adjacent fixed‐supported buildings are subjected to various earthquake excitations that induce structural impact among the buildings in series. The results indicate that the seismically isolated building may hit against the adjacent buildings at the upper floor levels before the occurrence of any pounding at the isolation level with the surrounding moat wall. The severity of the impact depends on the dynamic properties of the adjacent buildings, in combination with the earthquake characteristics. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A building with a seismic isolation system, in an earthquake, is recognized as producing substantially smaller accelerations and deformations compared with a building that use other systems. This type of system is therefore expected to better protect the building's nonstructural components, equipment, and other contents that are essential for the activities conducted in the building. Unlike many available studies on building responses, only a small number of studies on a buildings' nonstructural component responses are available, and no study has directly addressed building performance with regard to nonstructural component protection. This paper therefore measures the performance of various seismically isolated buildings. Specifically, the effects of important structural parameters, namely, isolation stiffness, isolation damping ratio, and number of stories on the response of base‐isolated structures are investigated parametrically. Ground motions with 2% exceedence in 50years Maximum Considered Earthquake (MCE) are used. Performance is compared with that of fixed‐base structures in order to present data that will be useful in justifying the more costly technology. The buildings are 3, 9, and 20 stories, represented by MDOF shear‐beam models. As examples of displacement‐sensitive and acceleration‐sensitive components, partition walls and ceilings are considered, respectively. The Pacific Earthquake Engineering Research Center performance‐based earthquake engineering methodology is adopted to evaluate the failure return periods of the examples based on their available fragility curves. In addition, the curves are varied hypothetically to understand the sensitivity of the return period to the curve features. Then, the median and dispersion of fragility curves required to satisfy the components' desired failure return period are obtained. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
In the present study, the seismic behavior of steel–concrete composite structures isolated by base-isolation devices under near-fault earthquake excitations is numerically investigated. The seismic analysis is performed by means of the static non-linear (pushover) analysis procedure conducted on two five-storey three-dimensional (3-D) buildings with steel columns and steel–concrete composite slabs and beams. The present 3-D building examples are assumed to be located at a near-fault area in order to take into account the effect of strong ground motion on the isolation devices. The results of this study allowed the verification of the adequacy of the attachment isolation system as well as the comparison of the behavior of the seismic-protected building with or without bracings to the unprotected buildings with or without bracings, showing the benefits of the application of the isolation devices, the limitations and the characteristics of their performance.  相似文献   

16.
In order to achieve a low isolation frequency, elastomeric bearings used for base isolation of buildings usually have low shear rigidity which leads to a significant reduction in the buckling load. The effects of compression load on the bearing behaviour are therefore an important consideration. A study of seismic response of base isolated buildings is presented in this paper, fully accounting for the P-Δ effects of isolation bearings. An analytical procedure is formulated that treats separately the superstructure and the supporting bearings and assembles the governing equations via the interaction forces at the base deck. The resulting equations are then solved step-by-step numerically. Numerical results obtained for a base isolated five-storey shear building show that neglecting the P-Δ effects can lead to considerable errors in the computed seismic response when the buckling safety factor of bearings is low.  相似文献   

17.
In this paper we study the sensitivity of seismically isolated structures to a small variability of the earthquake excitation and of some structural properties with respect to the probability of failure and floor spectra. In particular, the influence of the nonlinear behaviour of the isolated superstructure on the vulnerability and on the floor spectra is investigated by means of a series of Monte Carlo simulations of simple two degrees‐of‐freedom systems. Several types of passive and active isolation systems are examined and three different idealized nonlinear constitutive laws are considered for the superstructure. It is found that, in general, the probability of failure does not depend on the specific cyclic behaviour of the assumed constitutive law and general trends regarding the impact of different isolation devices on vulnerability are established. As for the floor spectra, the influence of moderate nonlinear behaviour of isolated superstructures, with the exception of the case of a non‐dissipative elastic nonlinear law, is negligible, contrary to the case of conventional structures. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
This paper examines the rocking response and stability of rigid blocks standing free on an isolated base supported: (a) on linear viscoelastic bearings, (b) on single concave and (c) on double concave spherical sliding bearings. The investigation concludes that seismic isolation is beneficial to improve the stability only of small blocks. This happens because while seismic isolation increase the ‘static’ value of the minimum overturning acceleration, this value remains nearly constant as we move to larger blocks or higher frequency pulses; therefore, seismic isolation removes appreciably from the dynamics of rocking blocks the beneficial property of increasing stability as their size increases or as the excitation pulse period decreases. This remarkable result suggests that free‐ standing ancient classical columns exhibit superior stability as they are built (standing free on a rigid foundation) rather than if they were seismically isolated even with isolation system with long isolation periods. The study further confirms this finding by examining the seismic response of the columns from the peristyle of two ancient Greek temples when subjected to historic records. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
通过对某小区小高层住宅2种结构方案的综合讨论,分析了小高层住宅的合理结构型式,提出了设计建议可供工程设计参考。异型柱框架-剪力墙结构框架柱布置灵活、隐蔽性好,但其柱截面不规则、计算理论不成熟、抗震能力较差、构造措施不理想、而且建筑自振周期长,侧向位移大,难以用于较高的高层住宅和抗震烈度较高的地区;大开洞剪力墙结构受力明确、计算理论成熟,又有较为精确的计算程序,而且墙厚可以在规范允许的范围内减薄,从而进一步降低了工程造价。通过2种方案比较,认为大开洞剪力墙体系与异型柱框剪结构相比,配筋总量基本接近,但其侧移较小,具有较好的延性,可应用于小高层住宅和地震烈度较高地区并可取得显著经济效益。  相似文献   

20.
The response of adjacent buildings in city blocks to several strong earthquakes is analysed, taking into account the mutual collisions, or pounding, resulting from insufficient or non-existing separation distances. The buildings are idealized as lumped-mass, shear beam type, multi-degree-of-freedom (MDOF) systems with bilinear force-deformation characteristics and with bases supported on translational and rocking spring-dashpots. Collisions between adjacent masses can occur at any level and are simulated by means of viscoelastic impact elements. Using five real earthquake motions the effects of the following factors are investigated: building configuration and relative size, seismic separation distance and impact element properties. It is found that pounding can cause high overstresses, mainly when the colliding buildings have significantly different heights, periods or masses. This suggests a possibility for introducing a set of conditions into the codes, combined with some special measures, as an alternative to the seismic separation requirement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏