首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
毛启佑  杨云 《矿物岩石》1991,11(3):103-106
用HNO_3—HCLO_4—HF混合酸,加压分解试样,以水平式ICP—AES可同时测定岩石中痕量铍、铬、锰、钒和锆。方法简单、现性好、准确度高。Bc,Cr,Mn,V,Zr的检出限分别为0.0001,0.002,0.002,0.002,0.005mg/ml,变异系数均小于5%。结果令人满意。  相似文献   

2.
人发中铜,锌,铁,锰,钙,镁,钾,钠的测定   总被引:3,自引:1,他引:3  
  相似文献   

3.
Brick-tea-type fluorosis is a peculiar endemic disease in China, which had been discovered in minority areas of western China since 1980, and distributed mainly in Tibet, Inner Mongolia, Gansu, Xinjiang, Qinghai and parts of Sichuan Province. The prevalence rate of fluorosis in Tibetan and Mongolian nationality people was higher. Epidemiological investigation showed that fluorosis morbidity and degrees were different in different brick-tea drinking areas, and it was probably caused by drinking various kinds of brick tea from different regions. Therefore, we collected 33 samples of brick tea from six provinces where minority nationalities were accustomed to drinking a large quantity of brick tea. F concentrations were determined by the combustion hydrolysis-ion selective electrode method. The results showed that among the brick teas, the F concentrations ranged from the minimum 74.1 mg/kg in Yunnan Province to the maximum 991.2 mg/kg in Sichuan Province. Besides, there was a great difference among the various kinds of brick tea, and F concentrations decreased in the order of Kang brick tea, Green brick tea, Black brick tea, Mi brick tea, Fu brick tea, Chitsu ping tea, Puerh tea, and Tuo tea. The average F concentration in brick teas was 431.92 mg/kg.  相似文献   

4.
锰—二氯苯基荧光酮—混合表面活性剂体系测定痕量锰   总被引:4,自引:0,他引:4  
王东进  吴钦莲 《岩矿测试》1991,10(2):158-158
本文研究了在CTMAB-OP存在下,Mn(Ⅱ)与2′,4′-二氯苯基荧光酮、水杨基荧光酮(SAF)及邻硝基苯基荧光酮的显色反应。结果表明,以2′,4′-二氯苯基荧光酮体系的灵敏度为最高。其ε=1.64×10~5L·mol~(-1)·cm~(-1),线性范围在0—5μg/25ml Mn(Ⅱ)。采用MIBK萃取分离可消除Fe(Ⅲ)等的干扰,而避免使用KCN。方法已用于测定白云石、磁铁矿、高硼玻璃及铝合金中的Mn,所得结果与标准值基本符合。  相似文献   

5.
6.
7.
土壤中微量铜,锌,铁,锰的原子吸收光谱测定   总被引:2,自引:0,他引:2  
  相似文献   

8.
原子吸收法测定血清中的铜,锌,铁,锰,钴和铬   总被引:1,自引:0,他引:1  
  相似文献   

9.
10.
在Clark-Lubs缓冲溶液(pH9.8)中,锰(Ⅱ)能催化过氧化氢氧化酸性铬蓝K的反应。据此,建立了测定痕量锰的分光光度新方法。方法灵敏度为1.49×10~(-6)μg/m~2。测定范围0~50ng/25ml。据Arrhenius方程式测得催化反应表观活化能为86.41KJ/mol。方法已用于硅酸盐单矿物中锰的测定,变异系数5.90%。  相似文献   

11.
12.
湖泊沉积物—水界面铁—锰循环研究新进展   总被引:18,自引:2,他引:18  
通过云贵高原深水湖泊沉积物-水界面铁-锰循环研究,揭示了湖泊铁-锰循环不仅受氧化还原边界层化学界面的控制,而且受沉积物-水地质界面的制约;有机质生物氧化和硫酸盐还原构成界面铁-锰循环的重要机制并产生亚扩散层屏蔽效应;铁-锰循环伴随有微量金属元素地球化学形态的改变,从而影响其迁移行为;气候剧烈变化所中断的铁-锰循环,形成铁-锰富集层的古环境记录。  相似文献   

13.
14.
15.
过去对该矿田的成因有过不少讨论,但多为非火山成因模式,这里介绍一个火山喷气模式。  相似文献   

16.
方耀奎  陆远 《广西地质》1997,10(3):23-28
文章通过广西凤凰山银锰矿床中的S-Fe-Cu-Ag-Sn系列矿物黄锡矿,含银黄锡矿,银黄锡矿,硫银锡矿的化学成分标型,标型矿物组合特征的研究,为该矿床的成因,深部隐伏银矿化,矿区及其外围的找矿提供了一定的信息。  相似文献   

17.
18.
Statistical data on major,trace and rare-earth elements in wolframite from the quartz vein-and greisen-type tin deposits in the Dupangling orefield reveal(1)The components in wolframite can be divided into two relatively independent groups:the WO3-Nb-Ta-Sc-REE group,in which WO3 is negatively correlated with the others and the FeO-MnO-Sn group,in which MnO is negatively corre-lated with the other two;(2)In general ,REE fractionation is not significant,reflected mainly by the separation of Eu from other REE‘s.LREE and HREE increase or decrease simultaneously ,with HREE being more variable;(3)Nb,Ta,Sc,REE substitute for W, and Sn may enter into wolframite lattice accompanied by Fe-Mn substitution;(4)In contrast to wolframite in quartz veins,which is poor in REE,Nb,Ta and has high δEu values and LREE/HREE and Nb/Ta ratios,wolframite in greisen is rich in REE, Nb,Ta,Sc and has low δEu values and LREE/HREE and Nb/Ta ratios ;and (5)The contents and ratios of trace elements and REE parti-tioning parameters of wolframite can be used as guide for prospecting.  相似文献   

19.
研究了新合成的meso-四(2-磺酸萘基)卟啉(TNPS4)与Mn^2+的显色反应。在pH8.0的Na2B4O7-HCl缓冲溶液中,TNPS4与Mn^2+形成稳定的配合物,最大吸收波长470nm,配合物组成为TNPS4:Mn^2+=2:1,表观摩尔吸光系数ε=1.03×10^5L·mol^-1·cm^-1,线性范围0.0-5.0μgMn^2+/25ml。用于化探样品中Mn的测定,结果令人满意。  相似文献   

20.
流动注射—催化光度法测定痕量锰   总被引:3,自引:0,他引:3  
吴丽  朱化雨 《岩矿测试》1996,15(2):120-123
在非离子表面活性剂吐温-80存在的H3PO4介质中,Mn^2+对V(V)氧化二安替比林苯乙烯甲烷(DAVPM)成红色化合物的反应具有较强的催化作用,基于此采用流动注射-催化光度法测定了痕量Mn^2+,该方法的检测波长为555nm,检出限为0.02μg/L Mn,线性范围为0.02 ̄6μg/L Mn,进样频率为60次/h,对5μg/L Mn进行10次测定的相对标准偏差为1.8%。经环境标准样品分析验  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号