首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Plate anchors are extensively used in civil engineering constructions as they provide an economical alternative to gravity and other embedded anchors. The rate of loading is one of the important factors that affects the magnitude of soil resistance as well as soil suction force. This article outlines the effect of pullout rate on uplift behavior of plate anchors (70 mm diameter) buried in soft saturated clay by varying the pullout rate from 1.4 mm/min to 21.0 mm/min. The variation of breakout force and suction force with embedment depth and rate of pull are presented. A correlation between the rate of increase of undrained strength of clay and anchor capacity with rate of strain has been established. Finally an empirical equation has been proposed that includes the rate of pull in the estimation of breakout capacity of anchors.  相似文献   

2.
To study the feasibility and efficiency of underwater suction anchors in soil, the performance of eight model anchors was evaluated in a 30 in. (76·2 cm) by 72 in. (183·0 cm) by 32 in. (81·3 cm) deep test tank. The soil studied were a medium fine sand, a silt and a clay. A gantry-type loading mechanisms was used to apply the vertical breakout force. A pullout rate of approximately 0·1 in/min (0·25 cm/min) was used for all tests.For the range of conditions studied, the test results indicate that the underwater suction anchor is feasible and effective. The breakout behavior of the suction anchors depends upon the anchor geometry including anchor diameter and skirt length, soil strength properties, soil-anchor friction and adhesion, and suction; i.e. the difference between the pressure underneath the porous plate and the ambient pressure. For the anchors and soils tested, the anchor capacity increases linearly with increasing suction provided the anchor skirt length to diameter ratio remains constant. An increase in the anchor capacity results with increasing suction and with increasing internal friction angle of the test soils. To study the results suggest that the underwater suction anchor is particularly useful for short-term anchorage.  相似文献   

3.
In the field of ocean engineering, a beginning has been made in the use of large‐sized suction anchors for safe anchoring of large compliant structures. Suction anchors derive most of their uplift resistance from passive suction developed during the pullout movement. This article describes a set of laboratory tests on model suction anchors of three different embedment ratios to estimate the pullout behavior of suction anchors in soft clays typical of Indian marine clays. Tests were conducted on model anchors installed in soil beds prepared at four different consistencies in a test tank. This study shows the influence of soil consistency and embedment ratio (L/D) on the pullout behavior of suction anchors and on the variation of suction pressure at the top of the soil plug. The test results reveal that the behavior of suction anchors is much better than the behavior of open‐ended anchors from the considerations of both capacity and deformation. The consistent development of suction inside the anchor top confirms the plug formation and significant breakout resistance in the form of suction‐induced reversed end bearing. The results are further analyzed in terms of suction breakout factors. Further, the effect of burial depth of suction anchor on pullout behavior is shown.  相似文献   

4.
As offshore energy developments move towards deeper water, moored floating production facilities are increasingly preferred to fixed structures. Anchoring systems are therefore of great interest to engineers working on deep water developments. Suction embedded plate anchors (SEPLAs) are rapidly becoming a popular solution, possessing a more accurate and predictable installation process compared to traditional alternatives. In this paper, finite element analysis has been conducted to evaluate the ultimate pullout capacity of SEPLAs in a range of post-keying configurations. Previous numerical studies of anchor pullout capacity have generally treated the soil as an elastic-perfectly plastic medium. However, the mechanical behaviour of natural clays is affected by inter-particle bonding, or structure, which cannot be accounted for using simple elasto-plastic models. Here, an advanced constitutive model formulated within the kinematic hardening framework is used to accurately predict the degradation of structure as an anchor embedded in a natural soft clay deposit is loaded to its pullout capacity. In comparison with an idealised, non-softening clay, the degradation of clay structure due to plastic strains in the soil mass results in a lower pullout capacity factor, a quantity commonly used in design, and a more complex load–displacement relationship. It can be concluded that clay structure has an important effect on the pullout behaviour of plate anchors.  相似文献   

5.
This article reports the response of embedded circular plate anchors to varying frequencies of cyclic loading. The effects of time period of loading cycles and pre-loading on movement of anchors and post-cyclic monotonic pullout behavior are studied using a model circular (80 mm diameter) plate anchor, buried at embedment ratio of six in a soft saturated clay. The frequencies of loading cycles have showed considerable effect on movement of anchors. For given duration of loading, higher frequency cycles cause more movement of anchor than lower frequency cycles. Pre-loading reduces the movement of anchors in subsequent loading stages. When anchors are recycled at a load ratio level less than the pre-cycling load, the movement of anchor in recycling phase are very much reduced, but if the recycling is done at a higher load ratio level, the effect is not that much pronounced and the anchors behave as if they were not subjected to any cycling load in the past. Anchor subjected to cyclic loading and then monotonic pullout shows an increase in initial stiffness, whereas the peak pullout load was found to decrease marginally over that of an anchor not subjected to any cyclic loading. For the present test conditions, the relative post-cyclic stiffness of anchors is found to vary from 1.169 to 1.327.  相似文献   

6.
Laboratory model test results for the uplift of a shallow circular plate anchor embedded in a soft saturated clay are presented. For all tests the bottom of the anchor plate was vented to eliminate the mud suction force. The tests were divided into two categories: (1) short‐term tests to determine the variation of the net ultimate uplift capacity and hence the breakout factor with embedment ratio, and (2) creep tests with sustained uplift loads at varying embedment ratios. Based on the model test results, the variation with time, has been determined for the rate of strain of the soil located above the plate anchor. Empirical relationships for obtaining the rate of anchor uplift have been proposed.  相似文献   

7.
K.D. Jones  Y. Cho 《Ocean Engineering》2007,34(16):2107-2114
An analytical solution has been developed to estimate the horizontal, vertical, and inclined loading pullout capacities of embedded suction anchors in sand. Validation of the analytical solution on pullout capacities has been made through comparisons with the centrifuge model test results. Primary variables for the centrifuge model tests are the depth to the loading point, the load inclination angle, and the addition of flanges. The results indicate that both the horizontal and vertical pullout capacities of the embedded suction anchor in sand increase, reach the peak and then start to decrease as the loading point moves downward. The inclined loading pullout capacity is very much dependent on the load inclination angle and the loading point. The effect of flanges on the pullout capacities is also found to be significant.  相似文献   

8.
A series of model tests were performed on steel- and Perspex-made suction caissons in saturated dense marine sand to explore installation and extraction behaviors. The extractions of the caisson were conducted by applying monotonic loading or by pumping water into the caisson. Responses of suction caissons to pullout rates, aspect ratios, and extraction manners were examined. Test results show that a cone-shaped subsidence region occurs around the suction caisson during the suction-assisted installation. The pullout bearing capacity of the suction caisson in sand is dominated by the loading rate and the loading manner. For the suction caisson subjected to monotonic loading, the maximum bearing capacity is reached at the pullout rate of about 20.0?mm/s. The mobilized vertical displacement corresponding to the pullout capacity increases with increasing the pullout rate. The passive suction beneath the suction caisson lid reaches the maximum value when the pullout bearing capacity is mobilized. In addition, during the suction caisson extracted by pumping water into the caisson, the maximum pore water pressure in the caisson is obtained under the displacement of approximately 0.04 times the caisson diameter. The absolute values of the maximum pore water pressures for the suction caissons approximately equal those of the maximum vertical resistances at the monotonic pullout rate of 5 mm/s. When the vertical displacements of the suction caissons with the aspect ratio of 1.0 and 2.0 reach 0.92 and 1.77 times the caisson diameter, respectively, the seepage failure occurs around the caissons. Using a scaling method, the test results can be used to predict the time length required for the prototype suction caisson to be extracted from the seabed.  相似文献   

9.
A series of model tests were conducted on Perspex-made suction caissons in saturated dense marine sand to study the sand plug formation during extraction. Suction caissons were extracted by pullout loading or by pumping air into the suction caisson. Effects of the pullout rates, aspect ratios and loading ways (monotonic or sustained) on the pullout capacity, and plug formation were investigated. It was found that the ultimate pullout capacity of the suction caisson increases with increasing the pullout rate. The sand plug formation under the pullout loading is significantly influenced by the pullout rate and the loading way. When the suction caisson is extracted at a relatively slow rate, the general sand boiling through the sand plug along the inner caisson wall occurs. On the contrary, the local sand boiling will occur at the bottom of the suction caisson subjected to a rapid monotonic loading or a sustained loading. Test results of the suction caisson extracted by pumping air into the caisson show that the pressure in the suction caisson almost follows a linear relationship with the upward displacement. The maximum pressures for suction caissons with aspect ratios of 1.0 and 2.0 during extraction by pumping air into the caisson are 1.70 and 2.27 times the maximum suction required to penetrate the suction caisson into sand. It was found that the sand plug moves downward during extraction by pumping air into the caisson and the variation in the sand plug height is mainly caused by the outflow of the sand particles from the inside of the suction caisson to the outside. When the suction caisson model is extracted under the pullout rate of 2?mm/s (0.28?mm/s for the prototype), the hydraulic gradient along the suction caisson wall increases to the maximum value with increasing the penetration depth and then reduces to zero. On the contrary, when extracted under the pullout rate of 10?mm/s (1.4?mm/s for the prototype), the hydraulic gradient along the suction caisson wall increases with increasing the pullout displacement. When extracted by pumping air into the caisson, the hydraulic gradient reaches the critical value, and at the same time, the seepage failure occurs around the suction caisson tip.  相似文献   

10.
Dai  Guo-liang  Zhu  Wen-bo  Zhai  Qian  Gong  Wei-ming  Zhao  Xue-liang 《中国海洋工程》2019,33(6):685-693
Suction caisson foundation derives most of their uplift resistance from passive suction developed during the pullout movement. It was observed that the passive suction generated in soil at the bottom of the caisson and the failure mode of suction caisson foundation subjecting pullout loading behaves as a reverse compression failure mechanism.The upper bound theorems have been proved to be a powerful method to find the critical failure mechanism and critical load associated with foundations, buried caissons and other geotechnical structures. However, limited attempts have been reported to estimate the uplift bearing capacity of the suction caisson foundation using the upper bound solution. In this paper, both reverse failure mechanisms from Prandtl and Hill were adopted as the failure mechanisms for the computation of the uplift bearing capacity of the suction caisson. New equations were proposed based on both failure mechanisms to estimate the pullout capacity of the suction caisson. The proposed equations were verified by the test results and experimental data from published literature. And the two solutions agree reasonably well with the other test results. It can be proved that both failure mechanisms are reasonably and more consistent with the actual force condition.  相似文献   

11.
A study was made to present analytical solutions of pullout load capacity for a suction caisson subjected to inclined tension in clay. The inclined tension on the skirt of the suction caisson is transformed into an equivalent system comprised of the vertical, horizontal, and moment load applied on the center of the lid. The vertical and horizontal stiffness coefficients along the skirt of the suction caisson in clay are presented by three-dimensional elastic solutions considering the nonhomogeneous and nonlinear property of clay. The vertical, horizontal, and rocking stiffness coefficient of the suction caisson on the base are presented considering the solutions of a hollow rigid cylindrical punch acting on the surface of clay. The envelopes of the horizontal and vertical ultimate load capacity for clay are presented. The yield, pullout, and failure for clay are taken into consideration. The effects of load inclination, loading depth, and aspect ratio on the pullout load capacity are shown. Behavior of the suction caisson in clay up to failure is investigated using the relationship between tensile load and displacement and that between depth, vertical, and horizontal pressure.  相似文献   

12.
This article reports the response of embedded circular plate anchors to varying frequencies of cyclic loading. The effects of time period of loading cycles and pre-loading on movement of anchors and post-cyclic monotonic pullout behavior are studied using a model circular (80 mm diameter) plate anchor, buried at embedment ratio of six in a soft saturated clay. The frequencies of loading cycles have showed considerable effect on movement of anchors. For given duration of loading, higher frequency cycles cause more movement of anchor than lower frequency cycles. Pre-loading reduces the movement of anchors in subsequent loading stages. When anchors are recycled at a load ratio level less than the pre-cycling load, the movement of anchor in recycling phase are very much reduced, but if the recycling is done at a higher load ratio level, the effect is not that much pronounced and the anchors behave as if they were not subjected to any cycling load in the past. Anchor subjected to cyclic loading and then monotonic pullout shows an increase in initial stiffness, whereas the peak pullout load was found to decrease marginally over that of an anchor not subjected to any cyclic loading. For the present test conditions, the relative post-cyclic stiffness of anchors is found to vary from 1.169 to 1.327.  相似文献   

13.
土层抗浮锚杆承载力关键影响因素现场试验研究   总被引:3,自引:1,他引:2  
工程实践及理论研究均表明,锚土界面特性和锚杆的几何形状是影响抗浮锚杆承载力的2个关键因素。采用不同的施工工艺进行现场试验施工,得到了具有不同锚土界面特性和锚杆几何形状的抗浮锚杆。通过现场锚杆抗拔试验得到锚杆的应力应变关系及极限抗拔承载力。研究结果表明,改善锚土界面特性和采用变截面的锚固体可显著提高锚杆的抗拔承载力。同时,提出了1种经济高效的抗浮锚杆施工工法。  相似文献   

14.
拖曳锚由于其承载性能和深水中便于安装被广泛应用于海洋工程系泊系统中,如:适用于悬链式系泊系统的传统拖曳锚和适用于绷紧式系泊系统的法向承力锚。拖曳锚安装过程中涉及诸多运动特性:锚板运动方向、系缆点处拖曳力和拖曳角及运动轨迹。基于大变形有限元分析技术耦合的欧拉-拉格朗日法,并引入缆绳方程,建立起锚-缆绳-海床土耦合作用的有限元分析模型;模拟了拖曳锚在均质和线性强度黏土中的嵌入安装过程,研究了锚板运动方向、系缆点处拖曳力和拖曳角及运动轨迹等运动特性;通过与已有的有限元分析方法及理论方法进行对比,验证了该分析模型的有效性;与已有的有限元分析方法相比,提出的分析模型有效地提高了计算效率。  相似文献   

15.
ABSTRACT

The suction caisson is commonly a top-closed cylindrical steel structure with large diameter, short length and much thinner skirt wall thickness. The resistance to penetrating is calculated as the sum of the tip bearing capacity and the adhesion on the both sides of the skirt wall. Since the thickness of the skirt wall is very small, the downward adhesion produced by the skirt wall will cause the additional vertical stress and shear stress in the soil at the skirt tip level, increasing the skirt tip resistance. However, the increase in skirt tip resistance caused by the additional vertical stress rather than shear stress in soil at the skirt tip level was only considered, this may lead to an inaccurate estimation for the tip bearing capacity and the suction required. Thus, a modified slip-line field is put forward in this study to estimate the tip resistance. The expression of obtaining the minimum suction to install the suction caisson in clay is derived in terms of the force equilibrium. Results from calculations of the minimum suction have been proved to be in a good agreement with the measured data.  相似文献   

16.
Three centrifuge model tests were performed in normally consolidated Speswhite Kaolin to study the penetration of suction anchors in soft clay. The suction anchors could be penetrated by means of underpressure to a depth of about 12.4 to a little more than 14.5 times the diameter. When the anchors were penetrated by underpressure, all clay displaced by the skirt moved into the anchor. At a penetration depth of about half the maximum penetration depth, the volume of the soil heave inside the anchor actually increased more than the volume of the displaced clay. When a material coefficient of 1.5 against plug failure was mobilized, more than the clay displaced by the skirts had accumulated inside the anchor. The penetration resistance increased by 42 and 26% during rest periods of 4.5 and 0.8 days prototype time, respectively. Some uncertainty in the shear strength of the clay beds gave some uncertainty with respect to the interpretation, but the observed behaviour generally confirmed the theoretical analyses.  相似文献   

17.
Determining the ultimate capacity of suction caissons in response to combined vertical, horizontal, and moment loading is essential for their design as foundations for offshore wind turbines. However, the method implemented for stability analysis is quite limited. Numerical limit analysis has an advantage over traditional limit equilibrium methods and nonlinear finite element methods in this case because upper and lower bounds can be achieved to ensure that the exact ultimate capacity of the caisson falls within the appropriate range. This article presents theories related to numerical limit analysis. Simulations are conducted for centrifuge model tests, the findings of which reveal the ability of numerical limit analysis to deal with the inclined pullout capacity of suction caissons. Finally, this article proposes an estimation of the ultimate capacity of a 3.5 MW offshore wind turbine foundation on normally consolidated clay based on the typical environmental parameters of Bothkennar, Scotland. Undrained failure envelopes and safety factors are obtained for suction caissons with different embedment ratios. Failure mechanisms, plastic zones, clay stress distributions, and the influence of the skin friction coefficients of caissons are discussed in detail.  相似文献   

18.
Abstract

In the field of ocean engineering, anchors are used for several purposes. This article studies the behavior of a helical anchor embedded in soft marine clay under vertical repetitive loading. Helical anchors are simple steel shafts to which one or more helical plates are attached at regular intervals. The tests are conducted on a model helical anchor installed in a soft marine clay bed prepared in a test tank. Repetitive loading is applied using a pneumatic loading arrangement. Different cyclic load ratios and time periods are adopted. In each test, after the application of repetitive loading, poststatic‐pullout tests are conducted to observe the effect of repetitive loading on anchor behavior. From the test results, it is found that, up to a cyclic load ratio of 55%, there is no reduction in capacity. Instead, there seems to be a marginal increase in capacity and reduction in displacement. The reasons for this behavior are explained in terms of induced changes in strength and deformation behavior of marine clay under repetitive load. However, at higher cyclic load ratios, there seems to be reduction in pullout capacity of the anchor, and the reason for this is explained in terms of strain criteria. From this investigation, it can be concluded that the deep anchor is more suitable to a marine environment than a shallow anchor.  相似文献   

19.
Drag anchor is a widely used economical anchor option for offshore floating structures. The anchor behavior under unidirectional loading and combined loading is important for anchor selection. The anchor behavior under combined loading, characterized by the yield envelope, can also be used for the prediction of anchor installation, which is still an issue in anchor design. However, most existing studies on anchor capacity are for plate anchors which focused only on the anchor pullout capacity in soil with uniform shear strength. The behavior of drag anchor under unidirectional and combined loading in soil with linearly increasing shear strength profile is seldom investigated. The current 2D finite element studies investigate the anchor behavior for a horizontal anchor fluke in clay with linearly increasing shear strength under unidirectional vertical, horizontal and rotational loadings first. Then based on the results of anchor unidirectional loading behavior, the yield envelopes for anchor under combined loading for both shallow and deep embedded flukes are studied. The effect of anchor embedment depth, soil non- homogeneity, soil overburden pressure and the soil/anchor interface breakaway conditions are studied to provide insight for drag anchor design.  相似文献   

20.
Gravity installed anchors (GIAs) are the most recent generation of anchoring solutions to moor floating facilities for deepwater oil and gas developments. Challenges associated with GIAs include predicting the initial embedment depth and evaluating the keying performance of the anchor. The former involves high soil strain rate due to large anchor penetration velocity, while the later influences the subsequent behavior and pullout capacity of the anchor. With the coupled Eulerian–Lagrangian method, three-dimensional large deformation finite element models are established to investigate the penetration and keying of GIAs in non-homogeneous clay. In the penetration model, a modified Tresca soil model is adopted to allow the effects of soil strain rate and strain softening, and user-defined hydrodynamic drag force and frictional resistance are introduced via concentrated forces. In the keying model, the anchor line effects are incorporated through a chain equation, and the keying, diving and pulling out behaviors of the anchor can all be replicated. Parametric studies are undertaken at first to quantify the effects of various factors on the performance of GIAs, especially on the penetration and keying behaviors. Based on the results of parametric studies, fitted formulae are proposed to give a quick evaluation of the anchor embedment depth after the installation, and the shackle horizontal displacement, shackle embedment loss and anchor inclination at the end of the keying. Comparative studies are also performed to verify the effectiveness of the fitted formulae.  相似文献   