首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Cadmium Zinc Telluride (CZT) detectors are high sensitivity and high resolution devices for hard X-ray imaging and spectroscopic studies. The new series of CZT detector modules (OMS40G256) manufactured by Orbotech Medical Solutions (OMS), Israel, are used in the RT-2/CZT payload onboard the CORONAS-PHOTON satellite. The CZT detectors, sensitive in the energy range of 20 to 150 keV, are used to image solar flares in hard X-rays. Since these modules are essentially manufactured for commercial applications, we have carried out a series of comprehensive tests on these modules so that they can be confidently used in space-borne systems. These tests lead us to select the best three pieces of the ??Gold?? modules for the RT-2/CZT payload. This paper presents the characterization of CZT modules and the criteria followed for selecting the ones for the RT-2/CZT payload. The RT-2/CZT payload carries, along with three CZT modules, a high spatial resolution CMOS detector for high resolution imaging of transient X-ray events. Therefore, we discuss the characterization of the CMOS detector as well.  相似文献   

2.
Spectroscopic observation of solar flares in the hard X-ray energy range, particularly the 20 ∼ 100 keV region, is an invaluable tool for investigating the flare mechanism. This paper describes the design and performance of a balloon-borne hard X-ray spectrometer using CdTe detectors developed for solar flare observation. The instrument is a small balloon payload (gondola weight 70 kg) with sixteen 10×10×0.5 mm CdTe detectors, designed for a 1-day flight at 41 km altitude. It observes in an energy range of 20−120 keV and has an energy resolution of 3 keV at 60 keV. The second flight on 24 May 2002 succeeded in observing a class M1.1 flare.  相似文献   

3.
The Cadmium Zinc Telluride Imager (CZTI) is a high energy, wide-field imaging instrument on AstroSat. CZTI’s namesake Cadmium Zinc Telluride detectors cover an energy range from 20 keV to \(>200\) keV, with 11% energy resolution at 60 keV. The coded aperture mask attains an angular resolution of 17\(^\prime \) over a 4.6\(^\circ \) \(\times \) 4.6\(^\circ \)  (FWHM) field-of-view. CZTI functions as an open detector above 100 keV, continuously sensitive to GRBs and other transients in about 30% of the sky. The pixellated detectors are sensitive to polarization above \(\sim \)100 keV, with exciting possibilities for polarization studies of transients and bright persistent sources. In this paper, we provide details of the complete CZTI instrument, detectors, coded aperture mask, mechanical and electronic configuration, as well as data and products.  相似文献   

4.
The Astronomical Röntgen Telescope X-ray Concentrator (ART-XC) is a hard X-ray telescope with energy response up to 30 keV, to be launched on board the Spectrum Röntgen Gamma (SRG) spacecraft in 2018. ART-XC consists of seven identical co-aligned mirror modules. Each mirror assembly is coupled with a CdTe double-sided strip (DSS) focal-plane detector. Eight X-ray mirror modules (seven flight and one spare units) for ART-XC were developed and fabricated at the Marshall Space Flight Center (MSFC), NASA, USA. We present results of testing procedures performed with an X-ray beam facility at MSFC to calibrate the point spread function (PSF) of the mirror modules. The shape of the PSF was measured with a high-resolution CCD camera installed in the focal plane with defocusing of 7 mm, as required by the ART-XC design. For each module, we performed a parametrization of the PSF at various angular distances Θ. We used a King function to approximate the radial profile of the near on-axis PSF (Θ < 9 arcmin) and an ellipse fitting procedure to describe the morphology of the far off-axis angular response (9 < Θ < 24 arcmin). We found a good agreement between the seven ART-XC flight mirror modules at the level of 10%. The on-axis angular resolution of the ART-XC optics varies between 27 and 33 arcsec (half-power diameter), except for the spare module.  相似文献   

5.
Hard X-ray Imager(HXI) is one of the three scientific instruments onboard the Advanced Spacebased Solar Observatory(ASO-S) mission, which is proposed for the 25th solar maximum by the Chinese solar community. HXI is designed to investigate the non-thermal high-energy electrons accelerated in solar flares by providing images of solar flaring regions in the energy range from 30 keV to 200 keV. The imaging principle of HXI is based on spatially modulated Fourier synthesis and utilizes about 91 sets of bi-grid sub-collimators and corresponding LaBr_3 detectors to obtain Fourier components with a spatial resolution of about 3 arcsec and a time resolution better than 0.5 s. An engineering prototype has been developed and tested to verify the feasibility of design. In this paper, we present background, instrument design and the development and test status of the prototype.  相似文献   

6.
One of the scientific objectives of NASA’s Fermi Gamma-ray Space Telescope is the study of Gamma-Ray Bursts (GRBs). The Fermi Gamma-Ray Burst Monitor (GBM) was designed to detect and localize bursts for the Fermi mission. By means of an array of 12 NaI(Tl) (8 keV to 1 MeV) and two BGO (0.2 to 40 MeV) scintillation detectors, GBM extends the energy range (20 MeV to > 300 GeV) of Fermi’s main instrument, the Large Area Telescope, into the traditional range of current GRB databases. The physical detector response of the GBM instrument to GRBs is determined with the help of Monte Carlo simulations, which are supported and verified by on-ground individual detector calibration measurements. We present the principal instrument properties, which have been determined as a function of energy and angle, including the channel-energy relation, the energy resolution, the effective area and the spatial homogeneity.  相似文献   

7.
Large area X-ray propositional counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3–80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of \({\sim }6000\,\hbox {cm}^{2}\) at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at \({\sim }\)2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. In this article, we present salient features of the LAXPC detectors, their testing and characterization in the laboratory prior to launch and calibration in the orbit. Some preliminary results on timing and spectral characteristics of a few X-ray binaries and other type of sources, are briefly discussed to demonstrate that the LAXPC instrument is performing as planned in the orbit.  相似文献   

8.
We present the first results from the low-energy detector payload of the solar X-ray spectrometer (SOXS) mission, which was launched onboard the GSAT-2 Indian spacecraft on May 08, 2003 by the GSLV-D2 rocket to study solar flares. The SOXS low-energy detector (SLD) payload was designed, developed, and fabricated by the Physical Research Laboratory (PRL) in collaboration with the Space Application Centre (SAC), Ahmedabad and the Indian Space Research Organization (ISRO) Satellite Centre (ISAC), Bangalore. The SLD payload employs state-of-the-art, solid-state detectors, viz., Si PIN and Cadmium-Zinc-Telluride (CZT) devices that operate at near room temperature (−20 °C). The energy ranges of the Si PIN and CZT detectors are 4 – 25 and 4 – 56 keV, respectively. The Si PIN provides sub-keV energy resolution, while the CZT provides ~1.7 keV energy resolution throughout the energy range. The high sensitivity and sub-keV energy resolution of the Si PIN detector allows measuring the intensity, peak energy, and the equivalent width of the Fe-line complex at approximately 6.7 keV, as a function of time in all ten M-class flares studied in this investigation. The peak energy (E p) of the Fe-line feature varies between 6.4 and 6.7 keV with increase in temperature from 9 to 58 MK. We found that the equivalent width (w) of the Fe-line feature increases exponentially with temperature up to 30 MK and then increases very slowly up to 40 MK. It remains between 3.5 and 4 keV in the temperature range of 30 – 45 MK. We compare our measurements of w with calculations made earlier by various investigators and propose that these measurements may improve theoretical models. We interpret the variation of both E p and w with temperature as being to the changes in the ionization and recombination conditions in the plasma during the flare, and as a consequence, the contribution from different ionic emission lines also varies.  相似文献   

9.
Cryogenic phonon–scintillation detectors (CPSD) for rare event search experiments require reliable, efficient and robust photon detectors that can resolve individual photons in a scintillation event. We report on a cryogenic detector containing a scintillating crystal, equipped with an NTD-Ge phonon sensor and a photon detector based on a low-temperature photomultiplier tube (PMT) that is powered by a Cockcroft–Walton generator. Here we present results from the characterisation of two detector modules, one with CaWO4, the other with CaMoO4 as scintillator. The energy resolutions (FWHM) at 122.1 keV for the scintillation/PMT channel are 19.9% and 29.7% respectively for CaWO4 and CaMoO4 while the energy resolutions (FWHM) for the phonon channels are 2.17 keV (1.8%) and 0.97 keV (0.79%). These characteristics compare favourably with other CPSDs currently used in cryogenic rare-event search experiments. The detection module with PMT readout benefits from the implementation of a well-understood, reliable, and commercially available component and improved time resolution, while retaining the major advantages of conventional CPSD, such as high sensitivity, resolving power and discrimination ability.  相似文献   

10.
Solid state detectors are used in x-ray and gamma-ray astronomy primarily for their fine spectroscopy. For some cases (e.g., gamma-ray observations with Ge detectors), the spectroscopy and sensitivity requirements drive the design of the aperture systems and only moderate-quality imaging is possible. In other cases (e.g., hard x-ray observations), the detectors can be finely segmented for highquality imaging. The new room-temperature solid-state detectors like CdZnTe and HgI2 are naturally well-suited for imaging. Because of their high atomic numbers, photoelectric absorption dominates over Compton scattering to >200 keV. This, combined with their high densities, allows thin detectors to be used with segmented contacts. Position resolution in the detector plane can be on 100 m scales giving sub-arcmin angular resolutions.  相似文献   

11.
We are proposing a mission devoted to high energy X-ray astronomy that is based on a focusing telescope operating in the 1?C200?keV energy range but optimized for the hard X-ray range. The main scientific topics concern: Physics of compact objects: The proximity of compact objects provides a unique laboratory to study matter and radiation in extreme conditions of temperature and density in strong gravitational environment. The emission of high energy photons from these objects is far from being understood. The unprecedented sensitivity in the high energy domain will allow a precise determination of the non-thermal processes at work in the vicinity of compact objects. The full 1?C200?keV energy coverage will be ideal to disentangle the emission processes produced in the spacetime regions most affected by strong-gravity, as well as the physical links: disk?Cthermal emission?Ciron line?Ccomptonisation?Creflection?Cnon-thermal emission?Cjets. Neutron stars?Cmagnetic field?Ccyclotron lines: Time resolved spectroscopy (and polarimetry) at ultra-high sensitivity of AXP, milliseconds pulsars and magnetars will give new tools to study the role of the synchrotron processes at work in these objects. Cyclotron lines?Cdirect measurement of magnetic filed?Cequation of state constraints?Cshort bursts?Cgiant flares could all be studied with great details. AGN: The large sensitivity improvement will provide detailed spectral properties of the high energy emission of AGN??s. This will give a fresh look to the connection between accretion and jet emission and will provide a new understanding of the physical processes at work. Detection of high-redshift active nuclei in this energy range will allow to introduce an evolutionary aspect to high-energy studies of AGN, probing directly the origin of the Cosmic X-ray Background also in the non-thermal range (> 20?keV). Element formation?CSupernovae: The energy resolution achievable for this mission (<0.5?keV) and a large high energy effective area are ideally suited for the 44Ti line study (68 and 78?keV). This radioactive nuclei emission will give an estimate of their quantities and speed in their environment. In addition the study of the spatial structure and spectral emission of SNR will advance our knowledge of the dynamics of supernovae explosions, of particles acceleration mechanisms and how the elements are released in the interstellar medium. Instrumental design: The progress of X-ray focusing optics techniques allows a major step in the instrumental design: the collecting area becomes independent of the detection area. This drastically reduces the instrumental background and will open a new era. The optics will be based on depth-graded multi-layer mirrors in a Wolter I configuration. To obtain a significant effective area in the hundred of keV range a focal length in the 40?C50 meters range (attainable with a deployable mast) is needed. In addition such a mission could benefit from recent progress made on mirror coating. We propose to cover the 1?C200?keV energy range with a single detector, a double-sided Germanium strip detector operating at 80?K. The main features will be: (a) good energy resolution (.150?keV at 5?keV and <.5?keV at 100?keV), (b) 3 dimensional event localization with a low number of electronic chains, (c) background rejection by the 3D localization, (d) polarisation capabilities in the Compton regime.  相似文献   

12.
13.
The Large Observatory For X-ray Timing (LOFT) is one of the candidate missions selected by the European Space Agency for an initial assessment phase in the Cosmic Vision programme. It is proposed for the M3 launch slot and has broad scientific goals related to fast timing of astrophysical X-ray sources. LOFT will carry the Large Area Detector (LAD), as one of the two core science instruments, necessary to achieve the challenging objectives of the project. LAD is a collimated detector working in the energy range 2-50 keV with an effective area of approximately 10 m 2at 8 keV. The instrument comprises an array of modules located on deployable panels. Lead-glass microchannel plate (MCP) collimators are located in front of the large-area Silicon Drift Detectors (SDD) to reduce the background contamination from off-axis resolved point sources and from the diffuse X-ray background. The inner walls of the microchannel plate pores reflect grazing incidence X-ray photons with a probability that depends on energy. In this paper, we present a study performed with an ad-hoc simulator of the effects of this capillary reflectivity on the overall instrument performance. The reflectivity is derived from a limited set of laboratory measurements, used to constrain the model. The measurements were taken using a prototype collimator whose thickness is similar to that adopted in the current baseline design proposed for the LAD. We find that the experimentally measured level of reflectivity of the pore inner walls enhances the off-axis transmission at low energies, producing an almost flat-top response. The resulting background increase due to the diffuse cosmic X-ray emission and sources within the field of view does not degrade the instrument sensitivity.  相似文献   

14.
The RHESSI Spectrometer   总被引:2,自引:0,他引:2  
Smith  D.M.  Lin  R.P.  Turin  P.  Curtis  D.W.  Primbsch  J.H.  Campbell  R.D.  Abiad  R.  Schroeder  P.  Cork  C.P.  Hull  E.L.  Landis  D.A.  Madden  N.W.  Malone  D.  Pehl  R.H.  Raudorf  T.  Sangsingkeow  P.  Boyle  R.  Banks  I.S.  Shirey  K.  Schwartz  Richard 《Solar physics》2002,210(1-2):33-60
RHESSI observes solar photons over three orders of magnitude in energy (3 keV to 17 MeV) with a single instrument: a set of nine cryogenically cooled coaxial germanium detectors. With their extremely high energy resolution, RHESSI can resolve the line shape of every known solar gamma-ray line except the neutron capture line at 2.223 MeV. High resolution also allows clean separation of thermal and non-thermal hard X-rays and the accurate measurement of even extremely steep power-law spectra. Detector segmentation, fast signal processing, and two sets of movable attenuators allow RHESSI to make high-quality spectra and images of flares across seven orders of magnitude in intensity. Here we describe the configuration and operation of the RHESSI spectrometer, show early results on in-flight performance, and discuss the principles of spectroscopic data analysis used by the RHESSI software.  相似文献   

15.
The “Fast X-ray Monitor” (BRM) instrument operated in the complex of the scientific instruments onboard the CORONAS-PHOTON satellite from February 19, 2009, until December 1, 2009. The instrument is intended for the registration of the hard X-ray radiation of solar flares in the 20–600 keV energy range in six differential energy channels (20–30, 30–40, 40–50, 50–70, 70–130, and 130–600 keV) with temporal resolution to 1 ms. In the instrument, a detector based on the YAP: Ce scintillator is used; this detector is 70 mm in diameter and 10 mm thick (the decay time is about 28 ns). For the decrease of the back-ground charge of the detector, the collimator limiting the angle of view of the instrument of value 12° is mounted over the scintillator. The effective area of the detector amounts to 27.7 cm2 (at the X-ray radiation energy 80 keV), and the dead time of the detector is 1 μs. Over the operation onboard the CORONAS-PHOTON satellite, the BRM instrument has registered gamma ray burst series and, perhaps, one solar flare of the class C1.3 on October 26, 2009.  相似文献   

16.
We have evaluated several solid state detectors which offer excellent energy resolution at room temperature for soft X-rays. For soft X-rays (< 1 keV to 20 keV), silicon P-intrinsic-N (PIN) and avalanche-mode photodiodes (APD's) have been studied. Using commercially available charge sensitive pre-amplifiers, these photodiodes provide 1 keV resolution without cooling. Their detection efficiencies are limited to about 20 keV and 15 keV, respectively. To overcome this constraint, we have studied thick (1.5 mm) PIN detectors made by Micron Semiconductor Ltd., U.K., as well as compound semiconducting materials with high Z constituents such as CZT and PbI2. PbI2 allows high detection efficiencies of photons up to 100 keV with detectors 100–300 microns thick. These new detectors offer the capability to study the low-energy spectral evolution of Gamma ray bursts (GRBs). A matrix of these detectors could be used as an image plane detector with moderate spatial resolution for imaging.  相似文献   

17.
《New Astronomy Reviews》2002,46(8-10):605-609
The SPI, Spectrometer aboard the ESA INTEGRAL satellite, to be launched in 2002, will study the gamma ray sky in the 20 keV to 8 MeV energy band with a spectral resolution of 2 keV for photons of 1 MeV thanks to its 19 germanium detectors. A coded mask imaging technique provides for a 2° angular resolution. An active BGO veto shield is used for background rejection. After the integration and test campaigns at CNES in Toulouse, the flight model of SPI has recently undergone a 1 month pre-launch calibration campaign at the CEA center of Bruyères le Châtel, using an accelerator for homogeneity measurements and high activity radioactive sources for imaging performance measurements. We report on the operational aspects of those measurements, whose analysis is foreseen to be published before launch.  相似文献   

18.
Lin  R. P.  Curtis  D. W.  Primbsch  J. H.  Harvey  P. R.  Levedahl  W. K.  Smith  D. M.  Pelling  R. M.  Duttweiler  F.  Hurley  K. 《Solar physics》1987,113(1-2):333-345

We describe a balloon payload designed to study the processes of energy release, particle acceleration, and heating of the active corona, in hard X-ray microflares and normal flares. An array of liquid nitrogen-cooled germanium detectors together with large area phoswich scintillation detectors provide the highest sensitivity (∼500 cm2) and energy resolution (≤0.7 keV) ever achieved for solar hard X-ray (∼15–600 keV) measurements. These detectors were flown in February 1987 from Australia on a long duration RAdiation COntrolled balloON (RACOON) flight (LDBF) which provided 12 days of observations before cutdown in Brazil. The payload includes solar cells for power, pointing and navigation sensors, a microprocessor controlled data system with VCR tape storage, and transmitters for GOES and ARGOS spacecraft. This successful flight illustrates the potential of LDBF's for solar flare studies.

  相似文献   

19.
The NATALYA-2M high-energy radiation spectrometer is an element of the complex of scientific equipment of the CORONAS-PHOTON satellite. The instrument intended for registering gamma radiation of solar flares in the broad energy range of 0.2–1600 MeV as well as neutrons of solar origin with energies of 20–300 MeV represents itself as a scintillation spectrometer based on CsI(Tl) crystals with a total area of 32 × 38 cm2 and the thickness of 18 cm. The spectra and time profiles of the gamma quanta count rates are measured in four subranges: R (0.2–2 MeV), L (1–18 MeV), M (7–250 MeV), and H (50–1600 MeV). Depending on the gamma radiation energy, the effective area of the instrument varies within the range from 750 to 900 cm2, and the energy resolution at the Cs-137 line (662 keV) is 10%, it being about 30% at energies higher than 50 MeV. A system of stabilization based on the signal from the generator of reference light pulses is used to provide stability and automated adjustment of the parameters of spectrometric modules. The measuring channels of the instrument are calibrated during the flight using a source of “tagged” gamma quanta on the Co-60 radioactive isotope. Polystyrene scintillation counters are used to provide protection from the background of charged particles. The “CORONAS-PHOTON” spacecraft (SC) was launched from the Plesetsk spaceport on January 30, 2009, to a low circular near-Earth orbit (the altitude is 550 km, the inclination is 82.5°). On February 27, the first scientific data were obtained from the NATALYA-2M instrument. The results of the flight calibration of the instrument detectors in different energy channels demonstrated good agreement with the ground measurements. The paper describes the instrument and observational potentials of the NATALYA-2M spectrometer, gives the results of the adjustment and calibration, and exemplifies the registration of gamma-ray bursts (GRBs)on the orbit.  相似文献   

20.
Astrosat is the first Indian satellite mission dedicated for astronomical studies. It is planned for launch during 2014 and will have five instruments for multi-wavelength observations from optical to hard X-rays. Cadmium Zing Telluride Imager (CZTI) is one of the five instruments aiming for simultaneous X-ray spectroscopy and imaging in the energy range of 10 keV to 100 keV (along with all sky photometric capability unto 250 keV). It is based on pixilated CZT detector array with total geometric area of 1024 cm2. It will have two-dimensional coded mask for medium resolution X-ray imaging. The CZT detector plane will be realized using CZT detector modules having integrated readout electronics. Each CZT detector module consists of 4 cm × 4 cm CZT with thickness of 5 mm which is further pixilated into 16 × 16 array of pixels. Thus each pixel has size of 2.5 mm × 2.5 mm and thickness of 5 mm. Such pixilated detector plane can in principle be used for hard X-ray polarization measurements based on the principle of Compton scattering by measuring azimuthal distribution of simultaneous events in two adjacent pixels. We have carried out detailed Geant4 simulations for estimating polarimetric capabilities of CZTI detector plane. The results indicate that events in the energy range of 100 keV to 250 keV, where the 5 mm thick CZT detector has significant detection efficiency, can be used for polarimetric studies. Our simulation results indicate the minimum detectable polarization (MDP) at the level of ~ 10% can be achieved for bright Crab like X-ray sources with exposure time of ~500 ks. We also carried out preliminary experiments to verify the results from our simulations. Here we present detailed method and results of our simulations as well as preliminary results from the experimental verification of polarimetric capabilities of CZT detector modules used in Astrosat CZTI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号