首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
DyeLIF? is a new version of laser‐induced fluorescence (LIF) for high‐resolution three‐dimensional subsurface mapping of nonaqueous phase liquids (NAPLs) in the subsurface. DyeLIF eliminates the requirement that the NAPL contains native fluorophores (such as those that occur in compounds like polynuclear aromatic hydrocarbons [PAHs]) and can therefore be used to detect chlorinated solvents and other nonfluorescing NAPLs that had previously been undetectable with conventional LIF tools. With DyeLIF, an aqueous solution of water and nontoxic hydrophobic dye is continuously injected ahead of the sapphire detection window while the LIF probe is being advanced in the subsurface. If soil containing NAPL is penetrated, the injected dye solvates into the NAPL within a few milliseconds, creating strong fluorescence that is transmitted via fiber‐optic filaments to aboveground optical sensors. A detailed field evaluation of the novel DyeLIF technology was performed at a contaminated industrial site in Lowell, Massachusetts, USA where chlorinated solvent dense nonaqueous phase liquid (DNAPL) persists below the water table in sandy sediments. Continuously cored boreholes were drilled adjacent to 5 of 30 DyeLIF probes that were advanced at that site. The cores were subsampled in high resolution to generate discrete‐depth soil samples as splits at the same depths where DNAPL was detected in the colocated DyeLIF probes. The cores were analyzed above ground using (1) colorimetric screening using hydrophobic dye tests, (2) laboratory extraction and quantitative chemical analysis, (3) “Benchtop” DyeLIF, and (4) volumetric moisture content. Correlation between DyeLIF and aboveground analyses of the soil cores was excellent: 98% agreement with positive DNAPL detections in samples where DNAPL pore saturations were >0.7% (based on quantitative soil analyses) and the ex situ tests. DyeLIF produced the equivalent of one aboveground colorimetric dye test every 0.2 inch (0.5 cm) of probing. With average daily probing of 395 linear feet (120.4 m), this was the equivalent of 12,039 discrete‐depth colorimetric dye tests/day. Because DyeLIF is an in situ measurement, there are no issues with soil core recovery like there would be for conventional ex situ colorimetric dye tests and 100% characterization of the probed intervals is achieved. Tracking the injection rate and pressure of the dye solution provides simultaneous data regarding relative soil permeability, similar to other direct push (DP) hydraulic profiling tools. Conventional LIF is considered the premier DP tool to identify and map NAPL containing PAHs in the subsurface or confirm its absence. While chlorinated solvent DNAPLs at some field sites contain impurities (e.g., solvated greases or oils) that make them detectable with conventional LIF techniques, at other sites, the DNAPL cannot be detected with conventional LIF. At such sites, the injection of a hydrophobic dye ahead of the sapphire window with the DyeLIF system now makes the LIF technology applicable to the many types of NAPLs that were previously invisible using conventional LIF techniques.  相似文献   

2.
A field demonstration was performed at Edwards Air Force Base to assess bioaugmentation for treatment of a well‐characterized tetrachloroethene (PCE) dense nonaqueous phase liquid (DNAPL) source area in fractured rock. Groundwater recirculation was employed to deliver remedial amendments, including bacteria, to facilitate reductive dechlorination and enhance DNAPL dissolution. An active treatment period of 9 months was followed by a 10‐month posttreatment rebound evaluation. Dechlorination daughter products were observed in both the shallow and deep fracture zones following treatment. In the shallow fracture zone, the calculated DNAPL mass removed was approximately equal to the DNAPL mass estimated using partitioning tracer testing, and no rebound in chlorinated ethenes or ethene was observed during the posttreatment period. A maximum DNAPL dissolution enhancement factor of 5 was observed in the shallow fracture zone. In the deep fracture zone, only approximately 45% of the DNAPL mass—as estimated via partitioning tracer testing—was removed and rebound in the total molar chlorinated ethenes + ethene was observed. The difference in behavior between the shallow and deep fracture zones was attributed to DNAPL architecture and the fracture flow field.  相似文献   

3.
DNAPL Characterization Methods and Approaches, Part 2: Cost Comparisons   总被引:1,自引:1,他引:1  
Contamination from the use of chlorinated solvents, often classified as dense nonaqueous phase liquids (DNAPLs) when in an undissolved state, pose environmental threats to ground water resources worldwide. DNAPL site characterization method performance comparisons are presented in a companion paper (Kram et al. 2001). This study compares the costs for implementing various characterization approaches using synthetic unit model scenarios (UMSs), each with particular physical characteristics. Unit costs and assumptions related to labor, equipment, and consumables are applied to determine costs associated with each approach for various UMSs. In general, the direct-push sensor systems provide cost-effective characterization information in soils that are penetrable with relatively shallow (less than 10 to 15 m) water tables. For sites with impenetrable lithology using direct-push techniques, the Ribbon NAPL Sampler Flexible Liner Underground Technologies Everting (FLUTe) membrane appears to be the most cost-effective approach. For all scenarios studied, partitioning interwell tracer tests (PITTs) are the most expensive approach due to the extensive pre-and post-PITT requirements. However, the PITT is capable of providing useful additional information, such as approximate DNAPL saturation, which is not generally available from any of the other approaches included in this comparison.  相似文献   

4.
5.
Air sparging was evaluated for remediation of tetrachloroethylene (PCE) present as dense nonaqueous phase liquid (DNAPL) in aquifers. A two-dimensional laboratory tank with a transparent front wall allowed for visual observation of DNAPL mobilization. A DNAPL zone 50 cm high was created, with a PCE pool accumulating on an aquitard. Detailed process control and analysis yielded accurate mass balances and insight into the mass-transfer limitations during air sparging. Initial PCE recovery rates were high, corresponding to fast removal of residual DNAPL within the zone influenced directly by air channels. The vadose zone DNAPL was removed within a few days, and the recovery in the extracted soil vapors decreased to low values. Increasing the sparge rate and pulsing the air injection led to improved mass recovery, as the pulsing induced water circulation and increased the DNAPL dissolution rate. Dissolved PCE concentrations both within and outside the zone of air channels were affected by the pulsing. Inside the sparge zone, aqueous concentrations decreased rapidly, matching the declining effluent PCE flux. Outside the sparge zone, PCE concentrations increased because highly contaminated water was pushed away from the air injection point. This overall circulation of water may lead to limited spreading of the contaminant, but accelerated the time-weighted average mass removal by 40% to 600%, depending on the aggressiveness of the pulsing. For field applications, pulsing with a daily or diurnal cycling time may increase the average mass removal rate, thus reducing the treatment time and saving in the order of 40% to 80% of the energy cost used to run the blowers. However, air sparging will always fail to remove DNAPL pools located below the sparge point because the air will rise upward from the top of a screen, unless very localized geological layers force the air to migrate horizontally. Unrecognized presence of DNAPL at chlorinated solvent sites residual and pools could potentially hamper success of air sparging cleanups, since the presence of small DNAPL pools, ganglia or droplets can greatly extend the treatment time.  相似文献   

6.
This study presents a multiphase flow and multispecies reactive transport model for the simultaneous simulation of NAPL and groundwater flow, dissolution, and reactive transport with isotope fractionation, which can be used for better interpretation of NAPL-involved Compound Specific Isotope Analysis in 3D heterogeneous hydrogeologic systems. The model was verified for NAPL-aqueous phase equilibrium partitioning, aqueous phase multi-chain and multi-component reactive transport, and aqueous phase multi-component transport with isotope fractionation. Several illustrative examples are presented to investigate the effect of DNAPL spill rates, degradation rate constants, and enrichment factors on the temporal and spatial distribution of the isotope signatures of chlorinated aliphatic hydrocarbon groundwater plumes. The results clearly indicate that isotope signatures can be significantly different when considering multiphase flow within the source zone. A series of simulations indicate that degradation and isotope enrichment compete with dissolution to determine the isotope signatures in the source zone: isotope ratios remain the same as those of the source if dissolution dominates the reaction, while heavy isotopes are enriched in reactants along groundwater plume flow paths when degradation becomes dominant. It is also shown that NAPL composition can change from that of the injected source due to the partitioning of components between the aqueous and NAPL phases even when degradation is not allowed in NAPL phase. The three-dimensional simulation is presented to mechanistically illustrate the complexities in determining and interpreting the isotopic signatures with evolving DNAPL source architecture.  相似文献   

7.
Contamination from the use of chlorinated solvents, often classified as dense nonaqueous phase liquids (DNAPLs) when in an undissolved state, represents an environmental challenge with global implications. Mass-transfer limitations due to rate-limited dissolution can lead to long-term aquifer persistence for even small volumetric fractions. The identification of DNAPL source zones located beneath the water table is critical to ultimately achieve site remediation and aquifer restoration. This paper provides a comparison of the advantages and disadvantages of many of the methods being used for detecting and delineating DNAPL contaminant source zones. The objective is to determine which options are best to pursue based on site characteristics, method performance, and method costs. DNAPL characterization methods are grouped into approaches, which include site preparation, characterization, and data-processing activities necessary to design an effective remediation system. We compare the different approaches based on the level of chemical and hydrogeologic resolution, and the need for additional data requirements. Our findings can be used to assist with selection of appropriate site remediation management options.  相似文献   

8.
Chlorinated degreasing solvents are multicomponent liquids containing not only the chlorinated hydrocarbons with which their name is associated (e.g., trichloroethylene or |TCE]. perchloroethylene or [PCE], 1,1,1-trichlorocihane [TCA]) but also a number of organic additives included as corrosion inhibitors and antioxidants. The additives, such as 1,4-dioxane, are likely to be of significant public-health importance as ground water contaminants due to their toxicity, solubility, and mobility. Following their use in vapor degreasing systems by industry, chlorinated degreasing solvents will also contain about 25% solubilized oil and grease.
A number of physical-chemical properties become especially important in the light of the multicomponent nature of these solvents. First, the higher aqueous solubility and lower sorption of the additives makes it is reasonable to expect that faster moving plumes of these solvent additives will precede plumes of the chlorinated hydrocarbons. Second, due to high losses of chlorinated hydrocarbons by volatilization from vapor degreasers during years in the middle of the century, it is probable that background concentrations of these hydrocarbons are present in ground water flow systems due to their downwind washout. Finally, the solubilized oil and grease may cause profound changes to the wettability of aquifer materials contacted by the solvents during their subsurface migration. It is argued, therefore, that the wettability of aquifer materials contaminated by chlorinated degreasing solvents needs to be experimentally determined before remediation of DNAPL at each site, rather than being simply assumed as water wet.  相似文献   

9.
Release of an estimated 150,000 gallons (568,000 L).of 1.2–dichloroethane (EDC) from a buried pipeline into a ditch and surrounding soil resulted in shallow subsurface contamination of a Gulf Coast site. Short-term remediation included removal of EDC DNAPI. (dense nonaqueous phase liquid) by dredging and vacuuming the ditch, and by dredging the river where the ditch discharged. EDC saturation in shallow impacted sediments located beneath the ditch was at or below residual saturation and these sediments were therefore left in place. The ditch was lined, backfilled, and capped. Long-term remediation includes EDC DNAPL recovery and hydraulic containment from the shallow zone with long-term monitoring of the shallow, intermediate, and deep (200 foot) aquifers. Ground water, DNAPL., and dissolved phase models were used to guide field investigations and the selection of an effective remedial action strategy. The DNAPL. modeling was conducted for a two-dimensional vertical cross section of the site, and included the three aquifers separated by two aquitards with microfractures. These aquitards were modeled using a dual porosity approach. Matrix and fracture properties of the aquitards used for DNAPL modeling were determined from small-scale laboratory properties. These properties were consistent with effective hydraulic conductivity determined from ground water flow modeling. A sensitivity analysis demonstrated that the vertical migration of EDC was attenuated by dissolution of EDC into the matrix of the upper aquitard. When the organic/water entry pressure of the aquitard matrix, or the solubility of EDC were decreased to unrealislically low values. EDC DNAPL. accumulated in the aquifer below the upper aquitard.
EDC DNALM, did not reach the regional (deepest) aquifer in any of the cases modeled. The limited extent of vertical EDC migration predicted is supported by ground water monitoring conducted over the four years since the spill.  相似文献   

10.
Adaptive site management and aggressive bioremediation in the source zone of a complex chlorinated dense nonaqueous phase liquid (DNAPL) site reduced total chlorinated hydrocarbon mass discharge by nearly 80%. Successful anaerobic bioremediation of chlorinated hydrocarbons can be impaired by inadequate concentrations of electron donors, competing electron acceptors, specific inhibitors such as chloroform, and potentially by high contaminant concentrations associated with residual DNAPL. At the study site, the fractured bedrock aquifer was impacted by a mixture of chlorinated solvents and associated daughter products. Concentrations of 1,1,2,2‐tetrachloroethane (1,1,2,2‐TeCA), 1,1,2‐trichloroethane (1,1,2‐TCA), and 1,2‐dichloroethane (1,2‐DCA) were on the order of 100 to 1000 mg/L. Chloroform was present as a co‐contaminant and background sulfate concentrations were approximately 400 mg/L. Following propylene glycol injections, concentrations of organohalide‐respiring bacteria including Dehalococcoides and Dehalogenimonas spp. increased by two to three orders of magnitude across most of the source area. Statistical analysis indicated that reaching volatile fatty acid concentrations greater than 1000 mg/L and depleting sulfate to concentrations less than 50 mg/L were required to achieve a Dehalococcoides concentration greater than the 104 cells/mL recommended for generally effective reductive dechlorination. In a limited area, chloroform concentrations greater than 5 mg/L inhibited growth of Dehalococcoides populations despite the availability of electron donor and otherwise appropriate geochemical conditions. After implementing a groundwater recirculation system targeting the inhibited area, chloroform concentrations decreased permitting significant increases in concentrations of Dehalococcoides and vinyl chloride reductase gene copies.  相似文献   

11.
Dense nonaqueous phase liquids (DNAPLs) are immiscible fluids with a specific gravity greater than, water. When present, DNAPLs present a serious and long-term source of continued ground water and soil contamination (Pankow and Cherry 1996). Accurate characterization and delineation of DNAPL in the subsurface is critical for evaluating restoration potential and for remedy design at a site. However, obtaining accurate and definitive direct evidence of DNAPL is difficult. A field study was recently performed comparing several approaches to DNAPL characterization at a site where anecdotal and limited direct evidence of DNAPL exists. The techniques evaluated included a three-dimensional high-resolution seismic survey, field screening of soil cores with a flame ionization detector (FID)/organic vapor analyzer (OVA), hydrophobic (Sudan IV) dye-impregnated reactive FLUTe® (Flexible Liner Underground Technologies) liner material in combination with Rotasonic drill cores, centrifuged soil with Sudan IV dye, ultraviolet light (UV) fluorescence, a Geoprobe® Membrane Interface Probe (MIP®), and phase equilibrium partitioning evaluations based on laboratory analysis of soil samples. Sonic drilling provided reliable continuous cores from which minor soil structures could be evaluated and screened with an OVA, The screening provided reliable preliminary data for identifying likely DNAPL zones and for selecting samples for further analyses. The FLUTe liner material provided the primary direct evidence of the presence of DNAPL and reliable information on the thickness and nature of its occurrence (i.e., pooled or ganglia). The MIP system provided good information regarding the subsurface lithology and rapid identification and delineation of probable DNAPL areas. The three-dimensional seismic survey was of minimal benefit to this study, and the centrifuging of samples with Sudan IV dye and the use of UV fluorescence provided no benefit. Results of phase equilibrium partitioning concentration calculations for soil samples (to infer the presence of DNAPL) were in good agreement with the site screening data. Additionally, screening data compared well with previous ground water data and supported using 1% of the pure phase solubility limit of Freon 113 (2 mg/L) as an initial means to define the DNAPL study area. Based on the results of this study, the preferred approach for identifying and delineating DNAPL in the subsurface is to initially evaluate ground water data and define an area where dissolved concentrations of the target analyte(s) approach 1% of the pure phase solubility limit. Within this study area, the MIP device is used to more specifically identify areas and lithologic zones where DNAPL may have accumulated. Core samples (either Rotasonic or Geoprobe) are then collected from zones where MIP readings are indicative of the presence of DNAPL. Soil samples from the free-product portions of the core(s) are then submitted to a laboratory for positive analyte identification. Soil analyses are then combined with site-specific geotechnical information (i.e., fraction organic carbon, soil bulk density, and porosity) and equilibrium partitioning algorithms used to estimate concentrations of organic contaminants in soil samples that would be indicative of free product. Used in combination, the soil analysis and the MIP records appear to provide accurate DNAPL identification and delineation.  相似文献   

12.
Pesticide residuals after point‐source pesticide spills in clay‐rich aquitards may potentially affect underlying groundwater for many decades due to slow release of accumulated pollution in the clayey matrix material of the aquitard. In this study, we evaluated factors behind different degrees of accumulation of phenoxy acids (MCPP, dichlorprop, 2,4‐D MCPA) and triazines (simazine and terbutylazine) observed in an old pesticide pollution described by Jørgensen et al. (2016a, this issue). By using leaching experiments, it was shown that a zone of maximum concentrations of MCPP and dichlorprop (mg/L) observed by Jørgensen et al. (2016a, this issue) represented accumulated potentially mobile pollution in anaerobic, however largely immobile pore water of the clayey matrix in the upper few meters of the unoxidized aquitard zone. By using sorption experiments, we determined 9 to16 times higher mobility by diffusion and flow for the phenoxy acids (R = 1 to 2) than for the triazines (R = 9 to 16) in the clayey matrix material of the aquitard. This indicated that more rapid and greater accumulation could occur for the phenoxy acids in the clayey matrix than for the triazines. In contrast, the relative mobility of the phenoxy acids and triazines was much closer in sand‐filled fractures and thin sand layers/lamina in the clay, suggesting that the migration of the same compounds along these textural preferential flow paths into the underlying aquifer was less different. Despite that a greater mass had originally been spilled of 2,4‐D and MCPA having similar mobility as the accumulated MCPP and dichlorprop, these compounds were not accumulated in the zone of maximum concentrations. It is suggested that the controls, which initially allowed for the observed separate accumulation of MCPP and dichlorprop as a zone of maximum pollution, were due to the combination of high persistence and high mobility for these specific pesticides in the clayey till matrix material of the aquitard. The investigation showed that over time the initial high concentrations of the accumulated phenoxy acids (MCPP, dichlorprop) transformed into high concentrations of related mobile degradation products (e.g., 4‐CPP and 2‐CPP), which extended the total time of groundwater pollution beyond the disappearance of the original phenoxyacids.  相似文献   

13.
Dense nonaqueous phase liquid (DNAPL) source areas containing chlorinated volatile organic compounds (cVOCs) such as trichloroethene (TCE) and perchloroethene (PCE) often give rise to significant dissolved plumes in groundwater, leading to the closure of downgradient water supply wells and creating vapor intrusion issues in buildings located above the plume. Hydraulic containment via pump‐and‐treat has often been implemented to limit migration but must continue indefinitely. Removal of the DNAPL source area by means such as in situ thermal remediation (ISTR) offers the potential to diminish or end the need for hydraulic containment if the associated dissolved plume attenuates sufficiently following source removal. A question often raised is whether this occurs or whether the back diffusion of contaminants from secondary sources such as low‐permeability lenses in the dissolved plume precludes it. The authors conducted DNAPL source removal using ISTR at dozens of sites. This paper presents a compilation of cases—10 separate DNAPL source areas at five project sites—where data indicate that the implementation of a thorough ISTR in a DNAPL source area can result in the attenuation of the associated dissolved plume, such that in several cases, long‐standing pump‐and‐treat systems could be turned off. Our findings contrast with recent assertions that aggressive source remediation may not be justifiable because dissolved plume concentrations will not decline sufficiently. We show that the application of ISTR can result in the thorough removal of the DNAPL source, effective diminution of dissolved plume groundwater concentrations, and achievement of drinking water standards.  相似文献   

14.
A release of 1,2-dichloroethane. also known as ethylene dichloride (EDC), resulted in shallow subsurface freephase contamination of a Gulf Coast site in the southern United States. The site stratigraphy consists primarily of a low permeability, surficial peat. silt, and clay zone underlain by fractured clay; a confined 12 in deep sand ground water flow zone; a confined 21 m deep fine sand zone of limited ground water flow, followed by a deep aquitard. The Gumbo clay and sandy clay aquitard below the release area overlies and protects the 61 m deep Upper Chicot Aquifer, which is a confined regional aquifer. An ongoing recovery and hydraulic containment program from the primary impacted and laterally and vertically restricted shallow 40-foot sand zone has effectively recovered dense nonaqueous phase liquid (DNAPL) and contained dissolved phase EDC.
Natural attenuation of EDC was demonstrated through (1) a laboratory microcosm study substantiating the ability of the native microbial population in the deeper aquifer lo degrade EDC under anaerobic environmental conditions found at the site. (2) field investigations showing reductions in EDC concentrations over time in many of the wells on site, and (3) an evaluation of the ground water for EDC and its degradation products and oilier geo-chemical parameters such as dissolved oxygen, redox potential, and pH. Degradation products of EDC found in the field investigations included 2-chloroeihanol, ethanol. ethene, and ethane. Dissolved EDC concentrations in selected wells between the first recorded samples and the fourth quarter of 1997 ranged from greater than 4% to 99% reductions. First-order exponential decay half-lives ranged from 0.21 to 4.2 years for wells showing decreases in FDC concentrations over time. Elevated methane concentrations indicated carbon dioxide to be the major terminal electron acceptor.  相似文献   

15.
At a low permeability clay till site contaminated with chlorinated ethenes (Gl. Kongevej, Denmark), enhanced reductive dechlorination (ERD) was applied by direct push injection of molasses and dechlorinating bacteria. The performance was investigated by long‐term groundwater monitoring, and after 4 years of remediation, the development of degradation in the clay till matrix was investigated by high‐resolution subsampling of intact cores. The formation of degradation products, the presence of specific degraders Dehalococcoides spp. with the vinyl chloride (VC) reductase gene vcrA, and the isotope fractionation of trichloroethene, cis‐dichloroethene (cis‐DCE), and VC showed that degradation of chlorinated ethenes occurred in the clay till matrix as well as in sand lenses, sand stringers, and fractures. Bioactive sections of up to 1.8 m had developed in the clay till matrix, but sections, where degradation was restricted to narrow zones around sand lenses and stringers, were also observed. After 4 years of remediation, an average mass reduction of 24% was estimated. Comparison of the results with model simulation scenarios indicate that a mass reduction of 85% can be obtained within approximately 50 years without further increase in the narrow reaction zones if no donor limitations occur at the site. Long‐term monitoring of the concentration of chlorinated ethenes in the underlying chalk aquifer revealed that the aquifer was affected by the more mobile degradation products cis‐DCE and VC generated during the remediation by ERD.  相似文献   

16.
The in situ vertical circulation column (ISVCC) is a cylindrical containment system consisting of an instrumented steel cylinder used for experimental ground water studies in sandy aquifers. Vertical flow is imposed inside the ISVCC. Although vertical wells are an option, the ISVCC installed in the Borden Aquifer is instrumented with horizontal wells and monitoring ports to avoid creating vertical preferential flow paths. The cylinder was driven downward into the aquifer using a small backhoe equipped with a vibrating plate. The ISVCC penetrates the 2.3-m-thic sand aquifer and is keyed 20 cm into the underlying clay aquitard. The cylinder was installed inside a 2 m X 2 m steel sheet pile enclosure so that the enclosed segment of aquifer could be conveniently dewatered and then excavated to allow installation of the horizontal wells. The dispersivity of the column was comparable to literature values for long sand-packed laboratory columns.
Pure phase DNAPL (tetrachloroethene and 1,1,1-trichloroethane) was slowly pumped into two ports in the center of the column. Following this DNAPL injection, an aqueous solution of vitamin B12 and reduced titanium was circulated through the column to promote degradation of the solvents. Processes observed in the ISVCC included DNAPL distribution, dissolution, and degradation, and geochemical evolution of the aquifer.
The ISVCC provides a convenient means for testing in situ technologies in the experimental stage or for selection of proven technologies to find the most effective at a specific site. It is inexpensive, easy to install, and maximizes control over flow distribution in a heterogeneous aquifer. Its application will be restricted where low hydraulic conductivity beds are present in the aquifer.  相似文献   

17.
The site characterization and analysis cone penetrometer system (SCAPS), equipped with realtime fluorophore detection capabilities, was used to delineate subsurface contaminant releases in an area where plating shop waste was temporarily stored. Records indicated that various nonaqueous phase liquids (NAPLs) were released at the site. The investigators advanced the SCAPS laser-induced fluorescence (LIF) sensor to depths beneath the water table of the principal water-bearing zone. The water table was located approximately 6 feet (1.8 m) below ground surface (bgs) across the site. Fluorescence, attributed to fuel compounds commingled with chlorinated solvents, was observed at depths ranging from 4.0 to 11.5 feet (1.2 to 3.5 m) bgs. Fluorescence, attributed to naturally occurring organic materials (by process of elimination and spectral characteristics) commingled with chlorinated solvent constituents, was observed at depths ranging from approximately 13 to 40 feet (4.0 to 12.2 m) bgs. Fluorescence responses from compounds confirmed to be commingled with chlorinated solvents indicates that the SCAPS fluorophore detection system is capable of indirectly delineating vadose zone and subaqueous chlorinated solvents and other dense nonaqueous phase liquids (DNAPLs) at contaminant release sites. This confirmation effort represents the first documented account of the successful application of LIF to identify a mixed DNAPL/LNAPL source zone.  相似文献   

18.
The migration of five dense nonaqueous phase liquids (DNAPLs) through a single fracture in a clay aquitard was numerically simulated with the use of a compositional simulator. The effects of fracture aperture, fracture dip, matrix porosity, and matrix organic carbon content on the migration of chlorobenzene, 1,2-dichloroethylene, trichloroethylene, tetra-chloroethylene, and 1,2-dibromoethane were examined. Boundary conditions were chosen such that DNAPL entry into the system was allowed to vary according to the stresses applied. The aperture is the most important factor of those studied controlling the migration rate of DNAPL through a single fracture embedded in a clay matrix. Loss of mass to the matrix through diffusion does not significantly retard the migration rate of the DNAPL, particularly in larger aperture fractures (e.g., 50 microm). With time, the ratio of diffusive loss to the matrix to DNAPL flux into the fracture approaches an asymptotic value lower than unity. The implication is that matrix diffusion cannot arrest the migration of DNAPL in a single fracture. The complex relationships between density, viscosity, and solubility that, to some extent, govern the migration of DNAPL through these systems prevent accurate predictions without the use of numerical models. The contamination potential of the migrating DNAPL is significantly increased through the transfer of mass to the matrix. The occurrence of opposite concentration gradients within the matrix can cause dissolved phase contamination to exist in the system for more than 1000 years after the DNAPL has been completely removed from the fracture.  相似文献   

19.
This paper presents a full‐scale thermal remediation of a brownfields site near San Francisco, California. In Situ Thermal Desorption (ISTD) was used for treatment of chlorinated solvents in a tight clay below the water table. The site had contaminants in concentrations indicating that a tetrachloroethene (PCE)‐rich DNAPL was present. A target volume of 5097 m3 of subsurface material to a depth of 6.2 m was treated for a period of 110 d of heating. Energy was delivered through 126 thermal conduction heater borings, and vapors were extracted from a combination of vertical and horizontal vacuum wells. Approximately 2540 kg of contaminants were recovered in the extracted vapors by the end of treatment. The PCE concentration in the clay was reduced from as high as 2700 mg/kg to an average concentration of 0.012 mg/kg within 110 d of heating (a reduction of >99.999%). Similar effectiveness was documented for TCE, cis‐1,2‐DCE, and vinyl chloride. A total of 2.2 million kWh of electric power was used to heat the site. Approximately 45% of this energy was used to heat the subsurface to the target temperature. Another 53% was necessary to boil approximately 41% of the groundwater within the treatment zone, creating approximately 600 pore volumes of steam by the end of the 110‐d heating and treatment period. Steam generation thus occurred within the clay. Partitioning of the contaminants into the steam and its removal comprised the dominant remedial mechanism. The steam migrated laterally toward the ISTD heaters, where it encountered a small dry region adjacent to each of the heaters, which served as a preferential pathway allowing the steam to migrate upward along the heaters to the more permeable vadose zone. There the steam was captured by a system of vertical and horizontal vacuum extraction wells. This vapor removal strategy facilitated effective thermal treatment of the tight clays located below the water table. Features of a robust design are extension of the heaters at least 1.2 m deeper than the treatment depth, and the installation of shallow horizontal vapor collection wells which allow for establishment of pneumatic control.  相似文献   

20.
At sites where a dense nonaqueous phase liquid (DNAPL) was spilled or released into the subsurface, estimates of the mass of DNAPL contained in the subsurface from core or monitoring well data, either in the nonaqueous or aqueous phase, can be highly uncertain because of the erratic distribution of the DNAPL due to geologic heterogeneity. In this paper, a multiphase compositional model is applied to simulate, in detail, the DNAPL saturations and aqueous-phase plume migration in a highly characterized, heterogeneous glaciofluvial aquifer, the permeability and porosity data of which were collected by researchers at the University of Tübingen, Germany. The DNAPL saturation distribution and the aqueous-phase contaminant mole fractions are then reconstructed by sampling the data from the forward simulation results using two alternate approaches, each with different degrees of sampling conditioning. To reconstruct the DNAPL source zone architecture, the aqueous-phase plume configuration, and the contaminant mass in each phase, one method employs the novel transition probability/Markov chain approach (TP/MC), while the other involves a traditional variogram analysis of the sampled data followed by ordinary kriging. The TP/MC method is typically used for facies and/or hydraulic conductivity reconstruction, but here we explore the applicability of the TP/MC method for the reconstruction of DNAPL source zones and aqueous-phase plumes. The reconstructed geometry of the DNAPL source zone, the dissolved contaminant plume, and the estimated mass in each phase are compared using the two different geostatistical modeling approaches and for various degrees of data sampling from the results of the forward simulation. It is demonstrated that the TP/MC modeling technique is robust and accurate and is a preferable alternative compared to ordinary kriging for the reconstruction of DNAPL saturation patterns and dissolved-phase contaminant plumes.  相似文献   