首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 30 毫秒
1.
为研究罕遇地震下复合隔震村镇建筑的地震响应特征及设计参数,采用ABAQUS有限元软件建立了复合隔震结构、滑移隔震结构、砂垫层隔震结构以及传统的砌体结构四种模型,通过对比4种模型在不同滑移层摩擦系数及不同地震烈度下的加速度、位移及底部剪力等动力响应差异,得出复合隔震体系的地震响应特征及主要设计参数。结果表明:复合隔震体系具有最优的隔震效果,且滑移层摩擦系数越小,地震烈度越大,隔震效果越好。根据预设40%隔震率的要求,确定出不同抗震设防烈度区的滑移层摩擦系数取值范围。  相似文献   

2.
A new isolation interface is proposed in this study to retrofit existing buildings with inadequate soft stories as well as new structures to be constructed with soft first story intended for architectural or functional purposes. The seismic interface is an assembly of bearings set in parallel on the top of the first story columns: the multiple‐slider bearings and rubber bearings. The multiple‐slider bearing is a simple sliding device consisting of one horizontal and two inclined plane sliding surfaces based on polytetrafluoroethylene and highly polished stainless steel interface at both ends set in series. A numerical example of a five‐story reinforced concrete shear frame with soft first story is considered and analyzed to demonstrate the efficiency of the proposed isolation system in reducing the ductility demand and damage in the structure while maintaining the superstructure above the bearings to behave nearly in the elastic range with controlled bearing displacement. Comparative study with the conventional system as well as various isolation systems such as rubber bearing interface and resilient sliding isolation is carried out. Moreover, an optimum design procedure for the multiple‐slider bearing is proposed through the trade‐off between the maximum bearing displacement and the first story ductility demand ratio. The results of extensive numerical analysis verify the effectiveness of the multiple‐slider bearing in minimizing the damage from earthquake and protecting the soft first story from excessively large ductility demand. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS) with numerous sliding interfaces.Based on the concept of subsystems,an equivalent series system that adopts existing nonlinear elements with parameters systematically calculated and mathematically proven through rigorous derivations is proposed.The aim is to simulate the characteristics of sliding motions for an MFPS isolation system with numerous concave sliding interfaces without prior knowledge of detailed information on the mobilized forces at various sliding stages.An MFPS with numerous concave sliding interfaces and one articulated or rigid slider located between these interfaces is divided into two subsystems: the fi rst represents the concave sliding interfaces above the slider,and the second represents those below the slider.The equivalent series system for the entire system is then obtained by connecting those for each subsystem in series.The equivalent series system is validated by comparing numerical results for an MFPS with four sliding interfaces obtained from the proposed method with those from a previous study by Fenz and Constantinou.Furthermore,these numerical results demonstrate that an MFPS isolator with numerous concave sliding interfaces,which may have any number of sliding interfaces,is a good isolation device to protect structures from earthquake damage through appropriate designs with controllable mechanisms.  相似文献   

4.
In this study, a series of shaking table tests are carried out on scaled models of two seismically isolated highway bridges to investigate the effect of rocking motion and vertical acceleration on seismic performance of resilient sliding isolators. In addition, performance of RSI is compared with system having solely natural rubber bearings. Test results show that variation of normal force on sliders due to rocking effect and vertical acceleration makes no significant difference in response of RSI systems. In addition, analytical response of prototype isolated bridge and the model used in experiments is obtained analytically by using non‐linear model for isolation systems. It is observed that for seismically isolated bridges, dynamic response of full‐scale complex structures can be predicted with acceptable accuracy by experiments using a simple model of the structure. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
利用实体软钢棒作为消能限位装置,将一种摩擦性能优良的二硫化钼材料作为隔震支座的滑移材料,提出并制作了一种可以应用于框架结构既能隔震又可以消能的新型摩擦滑移隔震装置。探讨了其设计方法和应用方法,并对安装了该新型摩擦滑移隔震装置的一相似比为1:5的5层框架结构模型进行了振动台试验,测试了框架结构在单向地震波作用下的地震反应规律,分析了摩擦滑移隔震结构的加速度反应、层间剪力反应、隔震层滑移量及隔震层剪力的变化规律。结果表明:一般情况下当设防烈度为8度,Ⅱ类场地时,该隔震结构的加速度响应可降低50%左右,层间剪力响应可降低50%左右,减震效果比较明显。另外,只要确定合理的构造方案和实施方案,这种新型摩擦滑移隔震装置就能满足框架结构的隔震减震要求,可应用于实际工程结构中。  相似文献   

6.
The seismic response of light secondary systems in a building is dependent on the response of the primary structural system to the seismic ground motion with the result that very high accelerations can be induced in such secondary systems. This response can be reduced through the use of aseismic base isolation which is a design strategy whereby the entire building can be decoupled from the damaging horizontal components of seismic ground motion by the use of some form of isolation system. The paper presents a theoretical analysis of the response of light equipment in isolated structures and a parallel experimental programme both of which show that the use of base isolation can not only attenuate the response of the primary structural system but also reduce the response of secondary systems. Thus, the design of equipment and piping in a base-isolated building is very much simpler than that for a conventionally founded structure: inelastic response and equipment-structure interaction need not be considered and multiple support response analysis is rendered unnecessary. Although an isolation system with linear elastic bearings can reduce the acceleration of the structure, it may be accompanied by large relative displacements between the structure and the ground. A system using lead-rubber hysteretic bearings, having a force-displacement relation which is approximately a bilinear loop, can reduce these displacements. A parallel experimental programme was carried out to investigate the response of light equipment in structures isolated using lead-rubber bearings. The experimental results show that these bearings can dissipate energy and limit the displacement and acceleration of the structure but are less effective in reducing the accelerations in the internal equipment. The results of both the analysis and the tests show that base isolation is a very effective method for the seismic protection of light equipment items in buildings.  相似文献   

7.
Base isolation has been established as the seismic design approach of choice when it comes to protecting nonstructural contents. However, while this protection technology has been widely shown to reduce seismic demands on attached oscillatory equipment and contents (EC), its effectiveness in controlling the response of freestanding EC that are prone to sliding has not been investigated. This study examines the seismic behavior of sliding EC inside base‐isolated buildings subjected to broadband ground motions. The effect of isolation system properties on the response of sliding EC with various friction coefficients is examined. Two widely used isolation models are considered: viscously damped linear elastic and bilinear. The study finds isolation to be generally effective in reducing seismic demands on sliding EC, but it also exposes certain situations where isolation in fact increases demands on EC, most notably for low friction coefficients and high earthquake intensities. Damping at the isolation level is effective in controlling the EC sliding displacements, although damping over about 20% is found to be superfluous. The study identifies a physically motivated dimensionless intensity measure and engineering demand parameter for sliding equipment in base‐isolated buildings subjected to broadband ground motions. Finally, the paper presents easy‐to‐use design fragility curves and an example that illustrates how to use them. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Vibration isolation is well recognized as an effective mitigation strategy for acceleration‐sensitive equipment subjected to earthquake. In the present paper, an equipment isolation system with nonlinear hysteretic behaviour is proposed and a methodology for the optimal design is developed. An integrable constitutive model, derived from the mathematical Duhem hysteresis operator, is adopted for the isolation system. The optimization procedure is defined through a dual‐criteria approach that involves a transmissibility criterion combined with an energy performance criterion: the former consists in limiting the absolute acceleration of the isolated equipment below an allowable threshold value; the latter, in maximizing the ratio between the energy dissipation due to hysteresis and the input energy to reduce the isolator displacements. The seismic effectiveness of the nonlinear hysteretic isolation system is numerically investigated under natural accelerograms with different frequency content and increasing levels of excitation. Both ground‐mounted and floor‐mounted equipment items are considered in the analyses; in the second case, the dynamic interaction between the equipment and its supporting structure is taken into account in the design of the isolation system, and its effects on the isolation performance and the structural response are discussed. Comparisons in terms of effectiveness and robustness with a linear isolation system with viscoelastic behaviour are eventually provided. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
村镇建筑多以砖混结构为主,抗震性能相对较弱,砂垫层摩擦滑移隔震技术由于诸多优点较适合广大农村建筑.本文介绍了砂垫层基础滑移隔震的设计原则和分析模型,以常见的两层砖混结构为例,采用Abaqus有限元软件分析不同摩擦系数、不同加速度峰值下隔震层的滑移,并在此基础上确定隔震层在多遇和罕遇地震作用下的摩擦系数及滑移量建议限值;通过验算不同砂浆的抗震受剪承载力,得出不同摩擦力作用下满足抗震受剪承载力的最低砂浆标准,所得结论对农村滑移隔震建筑的选材具有一定参考意义.  相似文献   

10.
This paper deals with floor acceleration spectra, which are used for the seismic design and assessment of acceleration‐sensitive equipment installed in buildings. In design codes and in practice, not enough attention has been paid to the seismic resistance of such equipment. An ‘accurate’ determination of floor spectra requires a complex and quite demanding dynamic response history analysis. The purpose of the study presented in this paper is the development of a direct method for the determination of floor acceleration spectra, which enables their generation directly from the design spectrum of the structure, by taking into account the structure's dynamic properties. The method is also applicable to inelastic structures, which can greatly improve the economic aspects of equipment design. A parametric study of floor acceleration spectra for elastic and inelastic single‐degree‐of‐freedom (SDOF) and multiple‐degree‐of‐freedom structures was conducted by using (non)linear response history analysis. The equipment was modelled as an elastic single‐degree‐of‐freedom system. The proposed method was validated by comparing the results obtained with the more accurate results obtained in a parametric study. Due to its simplicity, the method is an appropriate tool for practice. In the case of inelastic structural behaviour, the method should be used in combination with the N2 method, or another appropriate method for simplified nonlinear structural analysis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
变电站电气设备分级抗震设防原则研究   总被引:1,自引:0,他引:1       下载免费PDF全文
目前我国对电气设备抗震级别的规定低于国际上其他标准的要求,并且设防标准的确定考虑设防烈度、场地条件、设计地震分组等多种组合条件,不利于方便快捷地判断设备的抗震级别。通过对比国内外相关规范中对电气设备抗震设防级别的规定,分析电气设备进行分级抗震设防的优势,建议对我国的电气设备进行分级抗震设防。采用典型电气设备抗震可靠度指标作为参数,对建议的电气设备的抗震设防等级进行划分,提出高、中、低三等级原则。  相似文献   

12.
This paper focuses on seismic vulnerability assessment of restrained block‐type non‐structural components under sliding response on the basis of seismic inputs specified by current seismic codes. The general representation of restrained equipment considered in this study consists of a rigid block restrained by four post‐tensioned, symmetrically arranged cables. Two sliding‐related failure modes are considered: restraint breakage and excessive absolute acceleration. Fragility analysis is proposed as an appropriate tool to evaluate these failure modes. Sample fragility curves developed through Monte‐Carlo simulations show that the restraint breakage limit state is sensitive to the parameters of the equation of motion. For instance, fragility estimates obtained without taking into account vertical base accelerations can be significantly unconservative for relatively large values of the coefficient of friction. In contrast, the excessive absolute acceleration limit state exhibits little sensitivity to the parameters of the equation of motion. Peak absolute acceleration response is almost always equal to or greater than the horizontal peak base acceleration. Representative results suggest that reasonable response estimates for blocks located at stories other than the ground in multistorey buildings can in general be obtained by simply scaling the ground acceleration to the peak acceleration at the corresponding storey. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
Seismic response analysis of an irregular base isolated building   总被引:3,自引:0,他引:3  
This paper assesses the reliability of code-compliant linear and nonlinear dynamic analyses for irregular buildings with base isolation system (BIS). Comprehensive analyses are carried out for a case study comprising a large reinforced concrete multi-storey framed hospital with 327 high-damping rubber bearings. Spectral and time history (linear and nonlinear) analyses were performed on the three-dimensional (3D) finite element model (FEM) of the structure; simplified analyses were also conducted on single-degree-of-freedom (SDOF) systems. It is found that, at damageability limit state, the values of maximum interstorey drifts (d/h) computed with spectral analyses on the three-dimensional FEM range between 1/6 and 1/10 of the code limit (d/h = 0.33%); thus more stringent code limits should be required for buildings with BISs. The maximum floor acceleration is reduced by about 70% with respect to the ground acceleration (free field site); the acceleration profile is uniform along the height of the multi-storey frame. Threshold values of floor accelerations to assess the seismic performance of equipments in buildings with BIS are lacking. At ultimate limit state (ULS), spectral analyses provide values of actions and deformations that are less conservative than those derived through time history analyses. To perform reliable dynamic analyses of base isolated buildings it is crucial to select natural earthquake ground motions compliant with the fundamental period of vibration of the structural system. Nevertheless, it is not straightforward to select adequate natural strong motions in the catalogues available world-wide; buildings incorporating BISs possess periods of vibration which are generally higher than 2.0 s. As a result, distant and high-magnitude earthquakes are effective for base isolated buildings; nevertheless, such earthquakes are scarce in the seismic databases. The outcomes of the present study also demonstrate that simplified linear analyses tend to provide estimates of the response quantities, displacements of base isolators and base shear of the superstructure, which can be reliably employed at preliminary design stage. Spectral analysis results of the 3D model tend to match those of the SDOF systems, even for irregular superstructure, provided that modal mass participating ratios are greater than 85–90%. The results of spectral analyses on both SDOF and three-dimensional FEM envelope the outcomes of linear time histories.  相似文献   

14.
浮放设备地震滑移反应数值模拟研究   总被引:1,自引:0,他引:1  
以前人研究建立的浮放设备滑移反应分析理论为基础,给出了浮放设备在水平和竖向地震输入下滑移反应运动微分方程,选取连续型的库仑摩擦力模型,采用Runge-Kutta法求解浮放设备地震滑移反应运动微分方程,可以得到浮放设备在地震作用下的绝对加速度、相对速度和相对位移反应时程。采用编制的计算程序,进行了浮放设备地震滑移反应参数影响研究,结果表明:浮放设备水平滑移反应随着水平地震地面输入或楼层反应输入的增大而增大,随着设备与支撑面之间摩擦系数的增大而减小;当水平向输入加速度峰值大于0.3g时,需要考虑竖向激励的影响。  相似文献   

15.
层间滑移隔震结构地震作用有限元分析   总被引:4,自引:4,他引:0       下载免费PDF全文
将二硫化钼作为摩擦材料设计出一种带限位器的滑移隔震支座。根据多层框架结构变形的特点,给出适用于滑移框架隔震结构的计算模型,推导出层间滑移隔震结构的运动方程。运用SAP2000有限元软件建立一层间滑移框架隔震结构的有限元模型,对比分析El Centro地震波下摩擦系数和隔震层位置不同时隔震结构的地震反应。结果表明,上部结构的动力反应随摩擦系数的增加而不断增大,滑移隔震结构的减震效果逐渐减弱,但隔震层的滑移量却在不断减小;摩擦系数的选取应综合考虑减震效果和隔震层滑移量两个因素。随着隔震层的增高,结构的加速度反应和层间位移反应整体上呈增大趋势,隔震效果不断减弱,且隔震层的加速度值下部层比上部层要大得多,一层隔震和三层隔震时的变形主要集中于隔震层,而五层隔震时结构层间位移并未出现突变,说明隔震层设置在较高位置处对结构体系的影响较小。  相似文献   

16.
After an earthquake, non‐negligible residual displacements may affect the serviceability of a base isolated structure, if the isolation system does not possess a good restoring capability. The permanent offset does not affect the performance unless the design is problematic for utilities, also considering possible concerns related to the maintenance of the devices. Starting from experimental and analytical results of previous studies, the restoring capability of Double Concave Friction Pendulum bearings is investigated in this paper. A simplified design suggestion for the estimation of maximum expected residual displacements for currently used friction pendulum systems is then validated. The study is based on controlled‐displacement and seismic input experiments, both performed under unidirectional motion. Several shaking table tests have been carried out on a three‐dimensional isolated specimen structure. The same sequence of seismic inputs was applied considering three different conditions of sliding surfaces corresponding to low, medium and high friction. The accumulation of residual displacements is also investigated by means of nonlinear dynamic analysis. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

17.
The seismic response of a benchmark highway bridge isolated with passive polynomial friction pendulum isolators (PFPIs) is investigated and subjected to six bidirectional ground motion records. The benchmark study is based on a lumped mass finite-element model of the 91/5 highway overcrossing located in Southern California. The PFPI system possesses two important parameters; one is horizontal flexibility and the other is energy absorbing capacity through friction. The evaluation criteria of the benchmark bridge are analyzed considering two parameters, time period of the isolator and coefficient of friction of the isolation surface. The results of the numerical study are compared with those obtained from the traditional friction pendulum system (FPS). Dual design performance of the PFPI system suppressed the displacement and acceleration response of the benchmark highway bridge. The dual design hysteresis loop of the PFPI system is the main advantage over the linear hysteresis loop of the FPS. The numerical result indicates that the seismic performance of the PFPI system is better than that of the traditional FPS isolated system. Further, it is observed that variations of the isolation time period and coefficient of friction of the FPS and PFPI systems have a significant effect on the peak responses of the benchmark highway bridge.  相似文献   

18.
A novel low-cost friction sliding system for bidirectional excitation is developed to improve the seismic performance of reinforced concrete (RC) bridge piers. The sliding system is a spherical prototype developed by combining a central flat surface with an inclined spherical segment, characterized by stable oscillation and a large reduction in response accelerations on the flat surface. The inclined part provides a restoring force that limits the residual displacements of the system. Conventional steel and concrete are employed to construct a flat-inclined spherical surface atop an RC pier. The seismic forces are dissipated through the frictions generated during the sliding movements; hence, the seismic resilience of bridges can be ensured with a low-cost design solution. The proposed system is fabricated utilizing a mold created by a three-dimensional printer, which facilitates the use of conventional concrete to construct spherical shapes. The concrete surface is lubricated with a resin material to prevent abrasion from multiple input ground motions. To demonstrate the effectiveness of the system, bidirectional shaking table tests are conducted in the longitudinal and transverse directions of a scaled bridge model. The effect of the inclination angle and the flat surface size is investigated. The results demonstrate a large decrease in response acceleration when the system exhibits circular sliding displacement. Furthermore, the inclination angle that generates the smallest residual displacement is identified experimentally.  相似文献   

19.
The seismic response of a multi‐span continuous bridge isolated with novel superelastic‐friction base isolator (S‐FBI) is investigated under near‐field earthquakes. The isolation system consists of a flat steel‐Teflon sliding bearing and a superelastic NiTi shape memory alloy (SMA) device. The key design parameters of an S‐FBI system are the natural period of the isolated bridge, the yielding displacement of the SMA device, and the friction coefficient of the sliding bearings. The goal of this study is to obtain optimal values for each design parameter by performing sensitivity analysis of a bridge isolated by an S‐FBI system. First, a three‐span continuous bridge is modeled as two‐degrees‐of‐freedom with the S‐FBI system. A neuro‐fuzzy model is used to capture rate‐ and temperature‐dependent nonlinear behavior of the SMA device. Then, a set of nonlinear time history analyses of the isolated bridge is performed. The variation of the peak response quantities of interest is shown as a function of design parameters of the S‐FBI system and the optimal values for each parameter are evaluated. Next, in order to assess the effectiveness of the S‐FBI system, the response of the bridge isolated by the S‐FBI system is compared with the response of the non‐isolated bridge and the same bridge isolated by pure‐friction (P‐F) sliding isolation system. Finally, the influence of temperature variations on the performance of the S‐FBI system is evaluated. The results show that the optimum design of a bridge with the S‐FBI system can be achieved by a judicious specification of design parameters. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction sliding surface, seismic forces may be reduced but displacements are often unconstrained. In this paper, an alternative seismic bearing system, called the cable-sliding friction bearing system, is developed by integrating seismic isolation devices with displacement restrainers consisting of cables attached to the upper and lower plates of the bearing. Restoring forces are provided to limit the displacements of the sliding component. Design parameters including the length and stiffness of the cables, friction coefficient, strength of the shear bolt in a fixed-type bearing, and movements under earthquake excitations are discussed. Laboratory testing of a prototype bearing subjected to vertical loads and quasi-static cyclic lateral loads, and corresponding numerical finite element simulation analysis, were carried out. It is shown that the numerical simulation shows good agreement with the experimental force-displacement hysteretic response, indicating the viability of the new bearing system. In addition, practical application of this bearing system to a multi-span bridge in China and its design advantages are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号