首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
A three-dimensional soil–structure–liquid interaction problem is numerically simulated in order to analyze the dynamic behavior of a base-isolated liquid storage tank subjected to seismic ground motion. A dynamic analysis of a liquid storage tank is carried out using a hybrid formulation, which combines the finite shell elements for structures and the boundary elements for liquid and soil. The system is composed of three parts: the liquid–structure interaction part, the soil–foundation interaction part, and the base-isolation part. In the liquid–structure interaction part, the tank structure is modeled using the finite elements and the liquid is modeled using the internal boundary elements, which satisfy the free surface boundary condition. In the soil–foundation interaction part, the foundation is modeled using the finite elements and the half-space soil media are modeled using the external boundary elements, which satisfy the radiation condition in the infinite domain. Finally, above two parts are connected with the base-isolation system to solve the system's behavior. Numerical examples are presented to demonstrate the accuracy of the developed method, and an earthquake response analysis is carried out to demonstrate the applicability of the developed technique. The properties of a real LNG tank located in the west coast of Korea are used. The effects of the ground and the base-isolation system on the behavior of the tank are analyzed.  相似文献   

2.
A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid–structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions.  相似文献   

3.
Seismic fragility curves for fixed-base and base-isolated liquid storage tanks are developed under non-stationary earthquakes, and their seismic performance are compared. The correlation between different earthquake intensity measure (IM) parameters and peak response quantities of the base-isolated liquid storage tanks are investigated. The failure criteria are chosen based on (1) the elastic buckling strength of the tank wall, which is defined in terms of critical base shear and critical overturning moment, and (2) in terms of the critical isolation displacement. The uncertainty involved is considered in the earthquake characteristics. Non-stationary earthquake ground motions are generated using Monte Carlo (MC) simulation. Influence of the isolator characteristic parameters and modeling approaches on the seismic fragility of the base-isolated liquid storage tanks is also investigated. Peak ground acceleration is found to be the well correlated IM parameter with the peak response quantities of the base-isolated liquid storage tanks. Substantial decrease in the seismic fragility of the base-isolated liquid storage tanks is observed as compared to the fixed-base tanks. Significant influence of the isolator characteristic parameters on the seismic fragility of the base-isolated liquid storage tanks are reported in the present study.  相似文献   

4.
The non‐stationary rocking response of liquid storage tanks under seismic base excitations including soil interaction has been developed based on the wavelet domain random vibration theory. The ground motion has been characterized through statistical functionals of wavelet coefficients of the ground acceleration history. The tank–liquid–foundation system is modelled as a multi‐degree‐of‐freedom (MDOF) system with both lateral and rocking motions of vibration of the foundation. The impulsive and convective modes of vibration of the liquid in the tank have been considered. The wavelet domain coupled dynamic equations are formulated and then solved to get the expressions of instantaneous power spectral density function (PSDF) in terms of functionals of input wavelet coefficients. The moments of the instantaneous PSDF are used to obtain the stochastic responses of the tank in the form of coefficients of hydrodynamic pressure, base shear and overturning base moment for the largest expected peak responses. Parametric variations are carried out to study the effects of various governing parameters like height of liquid in the tank, height–radius ratio of the tank, ratio of total liquid mass to mass of foundation, and shear wave velocity in the soil medium, on the responses of the tank. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

5.
In this paper, an analytical method is proposed to determine the dynamic response of 3‐D rectangular liquid storage tanks with four flexible walls, subjected to horizontal seismic ground motion. Fluid–structure interaction effects on the dynamic responses of partially filled fluid containers, incorporating wall flexibility, are accounted for in evaluating impulsive pressure. The velocity potential in which boundary conditions are satisfied is solved by the method of separation of variables using the principle of superposition. The impulsive pressure distribution is then computed. Solutions based on 3‐D modeling of the rectangular containers are obtained by applying the Rayleigh–Ritz method using the vibration modes of flexible plates with suitable boundary conditions. Trigonometrical functions that satisfy boundary conditions of the storage tank such that the flexibility of the wall is thoroughly considered are used to define the admissible vibration modes. The analysis is then performed in the time domain. Moreover, an analytical procedure is developed for deriving a simple formula that evaluates convective pressure and surface displacements in a similar rigid tank. The variation of dynamic response characteristics with respect to different tank parameters is investigated. A mechanical model, which takes into account the deformability of the tank wall, is developed. The parameters of such a model can be obtained from developed charts, and the maximum seismic loading can be predicted by means of a response spectrum characterizing the design earthquake. Accordingly, a simplified but sufficiently accurate design procedure is developed to improve code formulas for the seismic design of liquid storage tanks. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
Storage tanks are vulnerable to earthquakes, as numerous major earthquakes have demonstrated. The trend of recent revisions to make seismic design criteria for large‐scale industrial storage tanks increasingly stringent has made development of cost‐effective earthquake‐resistant design and retrofit techniques for industrial tanks imperative. This study assesses the feasibility of seismic base isolation for making liquid‐filled storage tanks earthquake resistant. The sliding‐type friction pendulum seismic (FPS) bearings are considered rather than the elastomeric bearings because the dynamic characteristics of an FPS‐isolated tank remain unchanged regardless of the storage level. This work has devised a hybrid structural‐hydrodynamic model and solution algorithm, which would permit simple, accurate and efficient assessment of the seismic response of rigid cylindrical storage tanks in the context of seismic isolation. Extensive numerical simulations confirm the effectiveness of seismic base isolation of rigid cylindrical tanks using FPS bearings. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

7.
An approach is formulated for the linear analysis of three-dimensional dynamic soil–structure interaction of asymmetric buildings in the time domain, in order to evaluate the seismic response behaviour of torsionally coupled buildings. The asymmetric building is idealized as a single-storey three-dimensional system resting on different soil conditions. The soil beneath the superstructure is modeled as linear elastic solid elements. The contact surface between foundation mat and solid elements of soil is discretised by linear plane interface elements with zero thickness. An interface element is further developed to function between the rigid foundation and soil. As an example, the response of soil–structure interaction of torsionally coupled system under two simultaneous lateral components of El Centro 1940 earthquake records has been evaluated and the effects of base flexibility on the response behaviour of the system are verified.  相似文献   

8.
A hybrid analytical and FEM is proposed to investigate the nonlinear sloshing in a floating‐roofed oil storage tank under long‐period seismic ground motion. The tank is composed of a rigid cylindrical wall and a flat bottom, whereas the floating roof is treated as an elastic plate undergoing large deflection. The contained liquid is assumed to be inviscid and incompressible, and the flow is assumed to be irrotational. The method of analysis is based on representation of the liquid motion by superposing the analytical modes that satisfy the Laplace equation and the rigid wall and bottom boundary conditions. The FEM is then applied to solve the remaining kinematic and dynamic boundary conditions at the moving liquid surface coupled with the nonlinear equation of motion of the floating roof. This requires only the discretization of the liquid surface and the floating roof into finite elements, thus leading to a computationally efficient and accurate method compared with full numerical analysis. As numerical examples to illustrate the applicability of the proposed method, two oil storage tanks with single‐deck type floating roofs damaged during the 2003 Tokachioki earthquake are studied. It is shown that the nonlinear oscillation modes with the circumferential wave numbers 0, 2 and 3 caused by the finite liquid surface elevation as well as the membrane action due to large deflection of the deck produce excessively large stresses in the pontoon, which may cause the catastrophic failure of pontoon followed by the submergence of the roof. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Base isolation can be used both to protect the structure and simultaneously to reduce the response of internal equipment. The seismic response of a base-isolated structure has been studied through the shaking table test or numerical calculation before. The object of this paper is to analyse a base-isolated structure by a different analytical approach—perturbation analysis. Recognizing that the horizontal stiffness of an isolation system is much smaller than that of the superstructure, the mathematical expressions of the modal properties of base-isolated structures are derived by the perturbation method in terms of the modal properties of the superstructure and used to study the dynamic response of superstructure and attached equipment in the base-isolated building. This study shows that the first base-isolated mode not only controls the superstructural response but also dominates the response of high-frequency attachment. The contribution of higher modes to the response of base-isolated structures, which is proportional to the horizontal stiffness of isolation system, is very small.  相似文献   

10.
选用胡聿贤平稳地震地面运动模型作为基础隔震结构的随机地震动输入,采用Bouc-Wen模型描述隔震结构的层间滞变位移,将滞变体系动力特性矩阵随机等效线性化,并建立等价线性状态方程。引入左右特征向量系,对振动微分方程进行解耦,推导了基础隔震结构随机地震响应的统计矩解析解。采用变形失效准则,定义了上部结构和隔震层的功能状态极限函数。在此基础上,采用首次超越破坏模型,基于Possion分布假设和串联系统可靠度模型,建立了从整体上评价基础隔震体系抗震可靠度的简化分析方法。最后,通过一个基础隔震框架结构计算实例,说明了这种方法的运用。  相似文献   