A new semiactive independently variable damper, SAIVD, is developed and shown to be effective in achieving response reductions in smart base isolated buildings in near fault earthquakes. The semiactive device consists of four linear visco‐elastic elements, commonly known as Kelvin–Voigt elements, arranged in a rhombus configuration. The magnitude of force in the semiactive device can be adjusted smoothly in real‐time by varying the angle of the visco‐elastic elements of the device or the aspect ratio of the rhombus configuration. Such a device is essentially linear, simple to construct, and does not present the difficulties commonly associated with modelling and analysing nonlinear devices (e.g. friction devices). The smooth semiactive force variation eliminates the disadvantages associated with rapid switching devices. Experimental results are presented to verify the proposed analytical model of the device. A H control algorithm is implemented in order to reduce the response of base isolated buildings with variable damping semiactive control systems in near fault earthquakes. The central idea of the control algorithm is to design a H controller for the structural system that serves as an aid in the determination of the optimum control force in the semiactive device. The relative performance of the SAIVD device is compared to a variable friction device, recently developed by the authors in a separate study, and several key aspects of performance are discussed regarding the use of the two devices for reducing the responses of smart base isolated buildings in near fault earthquakes. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

2.
Effectiveness of a new semiactive independently variable stiffness (SAIVS) device in reducing seismic response of sliding base isolated buildings is evaluated analytically and experimentally. Through analytical and experimental study of force—displacement behaviour of the SAIVS device, it is shown that the device can vary stiffness continuously and smoothly between minimum and maximum stiffness. Passive sliding base isolation systems reduce interstorey drifts and superstructure accelerations, but with increased base displacements, which is undesirable, under large velocity near fault pulse type earthquakes. It is a common practice to incorporate non‐linear passive dampers into the isolation system to reduce bearing displacements. Incorporation of passive dampers, however, may result in increased superstructure accelerations and drifts; while, properly designed passive dampers can be beneficial. A viable alternative is to use semiactive variable stiffness systems, which can vary the period of the sliding base isolated buildings in real time, to simultaneously reduce bearing displacements and superstructure responses further than the passive systems, which deserves investigation. This study investigates the performance of a 1:5 scaled smart sliding base isolated building model equipped with the SAIVS device analytically and experimentally, under near fault earthquakes, by developing a new moving average non‐linear tangential stiffness control algorithm for control of the SAIVS device. The SAIVS device reduces bearing displacements further than the passive cases, while maintaining isolation level forces and superstructure responses at the same level as the passive minimum stiffness case, indicating the significant potential of the SAIVS system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

3.
The majority of the recent research effort on structural control considers two‐dimensional plane structures. However, not all buildings can be modelled as plane structures, thus limiting the capability of the proposed procedures only to regular and symmetrical structures. A new procedure is developed in this paper to analyse three‐dimensional buildings utilizing passive and active control devices. In the building model, the floors are assumed rigid in their own plane resulting in three degrees of freedom at each floor. Two types of active control devices utilizing an active tuned mass damper and an active bracing system are considered. The effect of passive mass dampers and active control force in the equations of motion is incorporated by using the Hamilton's principle. The passive parameters of the dampers as well as the controller gain is then optimized using a genetic based optimizer where the H2, H and L1 norms are taken as the objective functions. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

4.
This paper presents an innovative set of high‐seismic‐resistant structural systems termed Advanced Flag‐Shaped (AFS) systems, where self‐centering elements are used with combinations of various alternative energy dissipation elements (hysteretic, viscous or visco‐elasto‐plastic) in series and/or in parallel. AFS systems is developed using the rationale of combining velocity‐dependent with displacement‐dependent energy dissipation for self‐centering systems, particularly to counteract near‐fault earthquakes. Non‐linear time‐history analyses (NLTHA) on a set of four single‐degree‐of‐freedom (SDOF) systems under a suite of 20 far‐field and 20 near‐fault ground motions are used to compare the seismic performance of AFS systems with the conventional systems. It is shown that AFS systems with a combination in parallel of hysteretic and viscous energy dissipations achieved greater performance in terms of the three performance indices. Furthermore, the use of friction slip in series of viscous energy dissipation is shown to limit the peak response acceleration and induced base‐shear. An extensive parametric analysis is carried out to investigate the influence of two design parameters, λ1 and λ2 on the response of SDOF AFS systems with initial periods ranging from 0.2 to 3.0 s and with various strength levels when subjected to far‐field and near‐fault earthquakes. For the design of self‐centering systems with combined hysteretic and viscous energy dissipation (AFS) systems, λ1 is recommended to be in the range of 0.8–1.6 while λ2 to be between 0.25 and 0.75 to ensure sufficient self‐centering and energy dissipation capacities, respectively. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
In this paper, we propose a new actuator control algorithm that achieves the design flexibility, robustness, and tracking accuracy to give real‐time hybrid‐simulation users the power to achieve highly accurate and robust actuator control. The robust integrated actuator control (RIAC) strategy integrates three key control components: loop shaping feedback control based on H optimization, a linear‐quadratic‐estimation block for minimizing noise effect, and a feed‐forward block that reduces small residual delay/lag. The combination of these components provides flexible controller design to accommodate setup limits while preserving the stability of the H algorithm. The efficacy of the proposed strategy is demonstrated through two illustrative case studies: one using large capacity but relatively slow actuator of 2500 kN and the second using a small‐scale fast actuator. Actuator tracking results in both cases demonstrate that the RIAC algorithm is effective and applicable for different setups. Real‐time hybrid‐simulation validation is implemented using a three‐DOF building frame equipped with a magneto‐rheological damper on both setups. Results using the two very different physical setups illustrate that RIAC is efficient and accurate. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
In this work, we present a new method in designing static output‐feedback H controllers suitable for vibrational control of buildings under seismic excitation. The method produces a Linear Matrix Inequality (LMI) formulation that allows obtaining static output‐feedback controllers with different information structure constraints by imposing a convenient zero–nonzero structure on the LMI variables. The application of the proposed methodology is illustrated by designing centralized and decentralized velocity‐feedback H controllers to mitigate the seismic response of a five‐story building. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
Sliding base‐isolation systems used in bridges reduce pier drifts, but at the expense of increased bearing displacements under near‐source pulse‐type earthquakes. It is common practice to incorporate supplemental passive non‐linear dampers into the isolation system to counter increased bearing displacements. Non‐linear passive dampers can certainly reduce bearing displacements, but only with increased isolation level forces and pier drifts. The semi‐active controllable non‐linear dampers, which can vary damping in real time, can reduce bearing displacements without further increase in forces and pier drifts; and hence deserve investigation. In this study performance of such a ‘smart’ sliding isolation system, used in a 1:20 scaled bridge model, employing semi‐active controllable magneto‐rheological (MR) dampers is investigated, analytically and experimentally, under several near‐fault earthquakes. A non‐linear analytical model, which incorporates the non‐linearities of sliding bearings and the MR damper, is developed. A Lyapunov control algorithm for control of the MR damper is developed and implemented in shake table tests. Analytical and shake table test results are compared. It is shown that the smart MR damper reduces bearing displacements further than the passive low‐ and high‐damping cases, while maintaining isolation level forces less than the passive high‐damping case. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
Study on in-situ stress measurement around coastal marginal land in Fujian   总被引:1,自引:1,他引:1  
Introduction The southeast coastal margin of Chinese mainland is important to understand the mutual movement, matter exchange and energy transfer between ocean and land lithospheres, as well as their effects. The coastal area in Fujian Province is advanced in economy development but it has frequent earthquakes, or even strong earthquakes. Therefore, the current study on in-situ stress state measurement is of great significance for studying continental dynamics, marginal sea dy- namics, seismo…  相似文献   

10.
The response of a rigid block supported on a horizontally moving foundation through a dry‐friction contact is investigated to near‐fault ground motions. Such motions can be thought of as consisting of a coherent component (‘pulse’) and an incoherent component, which can be described as a band‐limited ‘random noise’. The equation of motion of this strongly nonlinear system is reduced to a normalized form that reveals important parameters of the problem such as the critical acceleration ratio. The response of the sliding block to a set of uniformly processed near‐fault motions, covering a sufficiently wide range of magnitudes, is evaluated numerically for selected discrete values of the acceleration ratio. For each value of the critical acceleration ratio, the numerically computed residual slips are fitted with a Weibull (Gumbel type III) extreme value probability distribution. This allows the establishment of regression equations that describe accurately design sliding curves corresponding to various levels of non‐exceedance probability. The analysis reveals that the coherent component of motion contributes significantly to the response of the sliding block. Furthermore, the relevant acceleration in specifying the critical acceleration ratio is the (normalized) amplitude, αH_pulse, of the pulse and not the (normalized) amplitude of the incoherent component αH. Finally, the incoherent component is described quantitatively in terms of the root‐mean‐square acceleration aRMS, and an attempt is made to understand its influence on the response of the sliding block. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
Complexities inherent to large‐scale modern civil structures pose many challenges in the design of feedback structural control systems for dynamic response mitigation. With the emergence of low‐cost sensors and control devices creating technologies from which large‐scale structural control systems can deploy, a future control system may contain hundreds, or even thousands, of such devices. Key issues in such large‐scale structural control systems include reduced system reliability, increasing communication requirements, and longer latencies in the feedback loop. To effectively address these issues, decentralized control strategies provide promising solutions that allow control systems to operate at high nodal counts. This paper examines the feasibility of designing a decentralized controller that minimizes the ?? norm of the closed‐loop system. ?? control is a natural choice for decentralization because imposition of decentralized architectures is easy to achieve when posing the controller design using linear matrix inequalities. Decentralized control solutions are investigated for both continuous‐time and discrete‐time ?? formulations. Numerical simulation results using a 3‐story and a 20‐story structure illustrate the feasibility of the different decentralized control strategies. The results also demonstrate that when realistic semi‐active control devices are used in combination with the decentralized ?? control solution, better performance can be gained over the passive control cases. It is shown that decentralized control strategies may provide equivalent or better control performance, given that their centralized counterparts could suffer from longer sampling periods due to communication and computation constraints. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
Passive energy dissipation devices (EDDs), such as viscous dampers, viscoelastic dampers, etc., have been used to effectively reduce the dynamic response of civil infrastructures, such as buildings and bridges, subject to earthquakes and strong winds. The design of these passive energy dissipation devices (EDDs) involves the determination of the optimal locations and the corresponding capacities. In this paper, we present two optimal design methodologies for passive EDDs based on active control theories, including H and H2 performances, respectively. The optimal design methodologies presented are capable of determining the optimal locations and the corresponding capacities of EDDs. Emphasis is placed on the application of linear matrix inequality (LMI) for the effective design of passive EDDs using the popular MATLAB toolboxes. One important advantage of the proposed approaches is that the computation of the structural response is not needed in the design process. The proposed optimal design methodologies have been applied to: (i) a 10‐storey building and a 24‐storey building both subject to earthquake excitations, and (ii) a 76‐storey wind‐excited benchmark building, to demonstrate the advantages of the proposed design methodologies over the conventional equal capacity design. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

13.
Soil H2 and CO2 surveys were carried out along seven active faults and around the aftershock region of the 2000 Tottori-ken Seibu earthquake in Japan. Diffuse CO2 effluxes were also measured along one fault and around the 2000 aftershock region. The results show highly variable H2 concentration in space and time and it seems that the maximum H2 concentration at each active fault correlates with fault activity as exemplified by the time of the latest big earthquakes. Even though observed H2 concentrations in four faults were markedly lower than those collected previously in the latter half of the 1970s, it is evident that the higher H2 concentrations in this study are due to the addition of the fault gases. Comparing the chemical composition of trapped gases (H2: 5–20% and CO2/H2: 0.5–12) in fractured rocks of drill cores bored at the Nojima fault, a soil gas sample with the highest H2 concentration showed large amounts of the trapped fault gas, diluted with atmospheric component. The profile experiment across a fracture zone at the Yamasaki fault showed higher H2 concentrations and lower CO2/H2 ratios as was observed in soil gas from the fracture zone. A few days after the 2000 Tottori-kei Seibu earthquake, no CO2 effluxes related to the occurrence of earthquakes were observed at the aftershock region. However, only above the epicenter zone, relatively high H2 concentrations in soil gases were observed.  相似文献   

14.
The concentration of H2 in soil gases has been measured weekly at five stations on the Atotsugawa and Ushikubi faults in northern central Main Island, Japan, since 1981 in search of possible relationship with earthquakes. The observed H2 concentration varies from lower than 1 ppm to 7.8% in time and place. When a large earthquake (M: 7.7, epicenter distance: 486 km) occurred on 26 May 1983, an outstanding discharge of H2 was observed at all five stations, preseismically at three of them, and coseismically at the other two. Simultaneous H2 emission was also observed at some stations in seven other occasions. These periods of unusual H2 discharge nearly coincided with occurrences of major earthquakes in Japan, but not of local minor earthquakes along the Atotsugawa fault. This fault, being a deep fracture zone, may be sensitive to large-scale crustal stress changes which incidentally cause the major earthquakes. Increased H2 may be produced by rock fracture caused by the increased stresses on the fault and by the earthquakes themselves. Local minor earthquakes along Atotsugawa fault with magnitude lower than 3 may be unable to cause sufficient rock fracture to produce significant H2.  相似文献   

15.
2008年2—4月,位于汶川大震初始破裂点的紫坪铺水库附近发生了一系列的小震活动,它们与汶川地震和紫坪铺水库小震的关系值得研究。本文采用CAP方法,反演了紫坪铺水库7个专用数字地震台站的数据,得到震级大于ML 1.0的28个震源机制解。结果表明:有19个地震事件集中在紫坪铺水库东南方向的都江堰附近,最大地震为逆冲型,发震机制为逆冲型带走滑分量,少量带正断层分量;从深度剖面看,地震震源深度主要集中分布在地下13km附近区域,都江堰震群丛集在前山断裂带上,其它地震散布在中央断裂带上;发震最大主压应力方向随时间的变化具有从最大主压应力方向变化比较大到趋向一致的演化过程。这些现象说明龙门山断裂带在都江堰附近存在1个凸凹体,形成应力集中点,引发都江堰震群活动,由此迫使龙门山断裂带前山断裂发生逆冲性活动,从而加剧了龙门山断裂带中央断裂的活动,在一定程度上加速了汶川地震的发生。  相似文献   

16.
The relation between the local mean lunar time τ of earthquake occurrence and their fault trends is studied in this paper. The local mean lunar times τ of 53 earthquakes in 24 groups are calculated. Because the tidal generation force arisen by the moon is a cyclic function of about 12 hours 25 minutes in the main, the two tidal generation forces anywhere in the earth arising by the moon are equal in general when the moon lies to the two sites of 180° interval of local mean lunar time. Based on this phenomenon the values Δτ of τ1–τ2 or τ1–τ2 ± 180° of two earthquakes occurring repetitiously in the same place are also calculated. The calculated results show that if the fault trends of the two earthquakes in the same place is near, the Δτ is usually smaller and if the fault trends of the two ones is not near, the Δτ is usually larger and the distribution of the local mean lunar time τ of earthquakes in different places is dispersive even if fault trends of these earthquakes are near, and the τ does not concentrate on the lower and upper transit of the moon. The above phenomena clear up that the triggering earthquake of earth solid tide arisen by the moon is relative with the fault trends of earthquakes and we ought to think over the difference of environmental conditions of earthquake preparation of each seismogenic zone and can not make statistics to earthquakes in different places when we study the relation between the solid earth tide arisen by the moon and earthquakes.  相似文献   

17.
In spite of important differences in structural response to near‐fault and far‐fault ground motions, this paper aims at extending well‐known concepts and results, based on elastic and inelastic response spectra for far‐fault motions, to near‐fault motions. Compared are certain aspects of the response of elastic and inelastic SDF systems to the two types of motions in the context of the acceleration‐, velocity‐, and displacement‐sensitive regions of the response spectrum, leading to the following conclusions. (1) The velocity‐sensitive region for near‐fault motions is much narrower, and the acceleration‐sensitive and displacement‐sensitive regions are much wider, compared to far‐fault motions; the narrower velocity‐sensitive region is shifted to longer periods. (2) Although, for the same ductility factor, near‐fault ground motions impose a larger strength demand than far‐fault motions—both demands expressed as a fraction of their respective elastic demands—the strength reduction factors Ry for the two types of motions are similar over corresponding spectral regions. (3) Similarly, the ratio um/u0 of deformations of inelastic and elastic systems are similar for the two types of motions over corresponding spectral regions. (4) Design equations for Ry (and for um/u0) should explicitly recognize spectral regions so that the same equations apply to various classes of ground motions as long as the appropriate values of Ta, Tb and Tc are used. (5) The Veletsos–Newmark design equations with Ta=0.04 s, Tb=0.35 s, and Tc=0.79 s are equally valid for the fault‐normal component of near‐fault ground motions. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

18.
A sliding mode fuzzy control (SMFC) algorithm is presented for vibration reduction of large structures. The rule base of the fuzzy inference engine is constructed based on the sliding mode control, which is one of the non‐linear control algorithms. In general, fuzziness of the controller makes the control system robust against the uncertainties in the system parameters and the input excitation, and the non‐linearity of the control rule makes the controller more effective than linear controllers. For verification of the present algorithm, a numerical study is carried out on the benchmark problem initiated by the ASCE Committee on Structural Control. To achieve a high level of realism, various aspects are considered such as actuator–structure interaction, sensor noise, actuator time delay, precision of the A/D and D/A converters, magnitude of control force, and order of control model. Performance of the SMFC is examined in comparison with those of other control algorithms such as Hmixed 2/∞, optimal polynomial control, neural networks control, and SMC, which were reported by other researchers. The results indicate that the present SMFC is efficient and attractive, since the vibration responses of the structure can be reduced very effectively and the design procedure is simple and convenient. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
This research investigates the development of a semi‐active piezoelectric friction damper for controlling the seismic response of large‐scale structures. The proposed device is made of Duplex steel and leads to high friction capacity, which can be developed either in passive or semi‐active modes. For the later, piezoelectric actuators react against a stiff clamping system and apply a variable normal force on the multiple contact surfaces. To validate the design, a prototype, which contact surfaces were made of stainless steel and brake pad material, was built and tested in both friction modes. Moreover, an analytical model of the damper was developed to estimate the performance of the piezoelectric actuators within the clamping system. Experimental results showed that the proposed device achieves a force range factor of 1.9. These experimental results also compare well with those obtained from the analytical model of the damper. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
In this paper, according to the results of the satellite imagery interpretation and field investigation, we study the active features and the latest active times of the Chuxiong-Nanhua fault, the Quaternary basins formation mechanism, and the relationship between the fault and the 1680 Chuxiong MS6 ¾ earthquake. Several Quaternary profiles at Lvhe, Nanhua reveal that the fault has offset the late Pleistocene deposits of the T2 and T3 terraces of Longchuan river, indicating that the fault was obviously active in late Quaternary. The Chuxiong-Nanhua fault has been dominated by dextral strike slip motion in the late Quaternary, with an average rate of 1.6-2.0mm/a. Several pull apart Quaternary basins of Chuxiong, Nanhua, and Ziwu etc. have developed along the fault. The 1680 Chuxiong MS6 ¾ earthquake and several moderate earthquakes have occurred near the fault. The Chuxiong-Nanhua fault are the seismogenic structure of those earthquakes, the latest fault movement was in the late-Pleistocene, and even the Holocene. In large area, the Chuxiong-Nanhua fault and the eastern Qujiang fault and the Shiping fault composed a set of NW-trending oblique orientation active faults, and the motion characteristics are all mainly dextral strike slip. The motion characteristics, like the red river fault of the Sichuan-Yunnan Rhombic Block southwestern boundary, are concerned with the escaping movement of the Sichuan-Yunnan Rhombic Block.  相似文献   