1.
Real‐time hybrid simulation provides a viable method to experimentally evaluate the performance of structural systems subjected to earthquakes. The structural system is divided into substructures, where part of the system is modeled by experimental substructures, whereas the remaining part is modeled analytically. The displacements in a real‐time hybrid simulation are imposed by servo‐hydraulic actuators to the experimental substructures. Actuator delay compensation has been shown by numerous researchers to vitally achieve reliable real‐time hybrid simulation results. Several studies have been performed on servo‐hydraulic actuator delay compensation involving single experimental substructure with single actuator. Research on real‐time hybrid simulation involving multiple experimental substructures, however, is limited. The effect of actuator delay during a real‐time hybrid simulation with multiple experimental substructures presents challenges. The restoring forces from experimental substructures may be coupled to two or more degrees of freedom (DOF) of the structural system, and the delay in each actuator must be adequately compensated. This paper first presents a stability analysis of actuator delay for real‐time hybrid simulation of a multiple‐DOF linear elastic structure to illustrate the effect of coupled DOFs on the stability of the simulation. An adaptive compensation method then proposed for the stable and accurate control of multiple actuators for a real‐time hybrid simulation. Real‐time hybrid simulation of a two‐story four‐bay steel moment‐resisting frame with large‐scale magneto‐rheological dampers in passive‐on mode subjected to the design basis earthquake is used to experimentally demonstrate the effectiveness of the compensation method in minimizing actuator delay in multiple experimental substructures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
Hydraulic actuators are typically used in a real‐time hybrid simulation to impose displacements to a test structure (also known as the experimental substructure). It is imperative that good actuator control is achieved in the real‐time hybrid simulation to minimize actuator delay that leads to incorrect simulation results. The inherent nonlinearity of an actuator as well as any nonlinear response of the experimental substructure can result in an amplitude‐dependent behavior of the servo‐hydraulic system, making it challenging to accurately control the actuator. To achieve improved control of a servo‐hydraulic system with nonlinearities, an adaptive actuator compensation scheme called the adaptive time series (ATS) compensator is developed. The ATS compensator continuously updates the coefficients of the system transfer function during a real‐time hybrid simulation using online real‐time linear regression analysis. Unlike most existing adaptive methods, the system identification procedure of the ATS compensator does not involve user‐defined adaptive gains. Through the online updating of the coefficients of the system transfer function, the ATS compensator can effectively account for the nonlinearity of the combined system, resulting in improved accuracy in actuator control. A comparison of the performance of the ATS compensator with existing linearized compensation methods shows superior results for the ATS compensator for cases involving actuator motions with predefined actuator displacement histories as well as real‐time hybrid simulations. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
Real‐time hybrid testing is a method that combines experimental substructure(s) representing component(s) of a structure with a numerical model of the remaining part of the structure. These substructures are combined with the integration algorithm for the test and the servo‐hydraulic actuator to form the real‐time hybrid testing system. The inherent dynamics of the servo‐hydraulic actuator used in real‐time hybrid testing will give rise to a time delay, which may result in a degradation of accuracy of the test, and possibly render the system to become unstable. To acquire a better understanding of the stability of a real‐time hybrid test with actuator delay, a stability analysis procedure for single‐degree‐of‐freedom structures is presented that includes both the actuator delay and an explicit integration algorithm. The actuator delay is modeled by a discrete transfer function and combined with a discrete transfer function representing the integration algorithm to form a closed‐loop transfer function for the real‐time hybrid testing system. The stability of the system is investigated by examining the poles of the closed‐loop transfer function. The effect of actuator delay on the stability of a real‐time hybrid test is shown to be dependent on the structural parameters as well as the form of the integration algorithm. The stability analysis results can have a significant difference compared with the solution from the delay differential equation, thereby illustrating the need to include the integration algorithm in the stability analysis of a real‐time hybrid testing system. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
Compensation of delay and dynamic response of servo‐hydraulic actuators is critical for stability and accuracy of hybrid experimental and numerical simulations of seismic response of structures. In this study, current procedures for compensation of actuator delay are examined and improved procedures are proposed to minimize experimental errors. The new procedures require little or no a priori information about the behavior of the test specimen or the input excitation. First, a simple approach is introduced for rapid online estimation of system delay and actuator command gain, thus capturing the variability of system response through a simulation. Second, an extrapolation procedure for delay compensation, based on the same kinematics equations used in numerical integration procedures is examined. Simulations using the proposed procedures indicate a reduction in high‐frequency noise in force measurements that can minimize the excitation of high‐frequency modes. To further verify the effectiveness of the compensation procedures, the artificial energy added to a hybrid simulation as a result of actuator tracking errors is measured and used for demonstrating the improved accuracy in the simulations. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
Real‐time hybrid testing is an experimental technique for evaluating the dynamic responses of structural systems under seismic loading. Servo‐hydraulic actuators, by nature, induce inevitable time delay between the command and the achieved displacements. This delay would lead to incorrect test results and even cause instability of the system; therefore, delay compensation is critical for stability and accuracy of hybrid simulations of structural dynamic response. In this paper, a dual delay compensation strategy is proposed by a combination of a phase lead compensator and a restoring force compensator. An outer‐loop feed‐forward phase lead compensator is derived by introducing the inverse model in the z domain. The adaptive law based on the gradient algorithm is used to estimate the system delay in the format of parametric model during the test. It is shown mathematically that the parameter in the delay estimator is guaranteed to converge. The restoring force compensator is adopted to improve the accuracy of experimental results especially when the structure is subjected to high frequency excitations. Finally, analytical simulations of an inelastic SDOF structure are conducted to investigate the feasibility of the proposed strategy. The accuracy of the dual compensation strategy is demonstrated through several shaking table tests. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Real‐time hybrid simulation represents a powerful technique capable of evaluating the structural dynamic performance by combining the physical simulation of a complex and rate‐dependent portion of a structure with the numerical simulation of the remaining portion of the same structure. Initially, this paper shows how the stability of real‐time hybrid simulation with time delay depends both on compensation techniques and on time integration methods. In particular, even when time delay is exactly known, some combinations of numerical integration and displacement prediction schemes may reduce the response stability with conventional compensation methods and lead to unconditional instability in the worst cases. Therefore, to deal with the inaccuracy of prediction and the uncertainty of delay estimation, a nearly exact compensation scheme is proposed, in which the displacement is compensated by means of an upper bound delay and the desired displacement is picked out by an optimal process. Finally, the advantages of the proposed scheme over conventional delay compensation techniques are shown through numerical simulation and actual tests. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
Real‐time dynamic substructuring is an experimental technique for testing the dynamic behaviour of complex structures. It involves creating a hybrid model of the entire structure by combining an experimental test piece—the substructure—with a numerical model describing the remainder of the system. The technique is useful when it is impractical to experimentally test the entire structure or complete numerical modelling is insufficient. In this paper, we focus on the influence of delay in the system, which is generally due to the inherent dynamics of the transfer systems (actuators) used for structural testing. This naturally gives rise to a delay differential equation (DDE) model of the substructured system. With the case of a substructured system consisting of a single mass–spring oscillator we demonstrate how a DDE model can be used to understand the influence of the response delay of the actuator. Specifically, we describe a number of methods for identifying the critical time delay above which the system becomes unstable. Because of the low damping in many large structures a typical situation is that a substructuring test would operate in an unstable region if additional techniques were not implemented in practice. We demonstrate with an adaptive delay compensation technique that the substructured mass–spring oscillator system can be stabilized successfully in an experiment. The approach of DDE modelling also allows us to determine the dependence of the critical delay on the parameters of the delay compensation scheme. Using this approach we develop an over‐compensation scheme that will help ensure stable experimental testing from initiation to steady state operation. This technique is particularly suited to stiff structures or those with very low natural damping as regularly encountered in structural engineering. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents the implementation details of a real‐time pseudodynamic test system that adopts an implicit time integration scheme. The basic configuration of the system is presented. Physical tests were conducted to evaluate the performance of the system and validate a theoretical system model that incorporates the dynamics and nonlinearity of a test structure and servo‐hydraulic actuators, control algorithm, actuator delay compensation methods, and the flexibility of an actuator reaction system. The robustness and accuracy of the computational scheme under displacement control errors and severe structural softening are examined with numerical simulations using the model. Different delay compensation schemes have been implemented and compared. One of the schemes also compensates for the deformation of an actuator reaction system. It has been shown that the test method is able to attain a good performance in terms of numerical stability and accuracy. However, it has been shown that test results obtained with this method can underestimate the inelastic displacement drift when severe strain softening develops in a test structure. This can be attributed to the fact that the numerical damping effect introduced by convergence errors becomes more significant as a structure softens. In a real‐time test, a significant portion of the convergence errors is caused by the time delay in actuator response. Hence, a softening structure demands higher precision in displacement control. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
The time delay resulting from the servo hydraulic systems can potentially destabilize the real‐time dynamic hybrid testing (RTDHT) systems. In this paper, the discrete‐time root locus technique is adopted to investigate the delay‐dependent stability performance of MDOF RTDHT systems. Stability analysis of an idealized two‐story shear frame with two DOFs is first performed to illustrate the proposed method. The delay‐dependent stability condition is presented for various structural properties, time delay, and integration time steps. Effects of delay compensation methods on stability are also investigated. Then, the proposed method is applied to analyze the delay‐dependent stability of a single shaking table RTDHT system with an 18‐DOF finite element numerical substructure, and corresponding RTDHTs are carried out to verify the theoretical results. Furthermore, the stability behavior of a finite element RTDHT system with two physical substructures, loaded by twin shaking tables, is theoretically and experimentally investigated. All experimental results convincingly demonstrate that the delay‐dependent stability analysis on the basis of the discrete‐time root locus technique is feasible. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Real‐time pseudodynamic (PSD) and hybrid PSD test methods are experimental techniques to obtain the response of structures, where restoring force feedback is used by an integration algorithm to generate command displacements. Time delays in the restoring force feedback from the physical test structure and/or the analytical substructure cause inaccuracies and can potentially destabilize the system. In this paper a method for investigating the stability of structural systems involved in real‐time PSD and hybrid PSD tests with multiple sources of delay is presented. The method involves the use of the pseudodelay technique to perform an exact mapping of fixed delay terms to determine the stability boundary. The approach described here is intended to be a practical one that enables the requirements for a real‐time testing system to be established in terms of system parameters when multiple sources of delay exist. Several real‐time testing scenarios with delay that include single degree of freedom (SDOF) and multi‐degree of freedom (MDOF) real‐time PSD/hybrid PSD tests are analyzed to illustrate the method. From the stability analysis of the real‐time hybrid testing of an SDOF test structure, delay‐independent stability with respect to either experimental or analytical substructure delay is shown to exist. The conditions that the structural properties must satisfy in order for delay‐independent stability to exist are derived. Real‐time hybrid PSD testing of an MDOF structure equipped with a passive damper is also investigated, where observations from six different cases related to the stability plane behavior are summarized. Throughout this study, root locus plots are used to provide insight and explanation of the behavior of the stability boundaries. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
Real‐time hybrid testing is a very effective technique for evaluating the dynamic responses of rate‐dependent structural systems subjected to earthquake excitation. A smart base isolation system has been proposed by others using conventional low‐damping isolators and controllable damping devices such as magnetorheological (MR) dampers to achieve specified control target performance. In this paper, real‐time hybrid tests of a smart base isolation system are conducted. The simulation is for a base‐isolated two‐degrees‐of‐freedom building model where the superstructure and the low‐damping base isolator are numerically simulated, and the MR damper is physically tested. The target displacement obtained from the step‐by‐step integration of the numerical substructure is imposed on the MR damper, which is driven by three different control algorithms in real‐time. To compensate the actuator delay and improve the accuracy of the test, an adaptive phase‐lead compensator is implemented. The accuracy of each test is investigated by using the root mean square error and the tracking indicator. Experimental results demonstrate that the hybrid testing procedure using the proposed actuator compensation techniques is effective for investigating the control performance of the MR damper in a smart base isolation system. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Real‐time hybrid testing combines experimental testing and numerical simulation, and provides a viable alternative for the dynamic testing of structural systems. An integration algorithm is used in real‐time hybrid testing to compute the structural response based on feedback restoring forces from experimental and analytical substructures. Explicit integration algorithms are usually preferred over implicit algorithms as they do not require iteration and are therefore computationally efficient. The time step size for explicit integration algorithms, which are typically conditionally stable, can be extremely small in order to avoid numerical stability when the number of degree‐of‐freedom of the structure becomes large. This paper presents the implementation and application of a newly developed unconditionally stable explicit integration algorithm for real‐time hybrid testing. The development of the integration algorithm is briefly reviewed. An extrapolation procedure is introduced in the implementation of the algorithm for real‐time testing to ensure the continuous movement of the servo‐hydraulic actuator. The stability of the implemented integration algorithm is investigated using control theory. Real‐time hybrid test results of single‐degree‐of‐freedom and multi‐degree‐of‐freedom structures with a passive elastomeric damper subjected to earthquake ground motion are presented. The explicit integration algorithm is shown to enable the exceptional real‐time hybrid test results to be achieved. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
We present a comparison of methods for the analysis of the numerical substructure in a real‐time hybrid test. A multi‐tasking strategy is described, which satisfies the various control and numerical requirements. Within this strategy a variety of explicit and implicit time‐integration algorithms have been evaluated. Fully implicit schemes can be used in fast hybrid testing via a digital sub‐step feedback technique, but it is shown that this approach requires a large amount of computation at each sub‐step, making real‐time execution difficult for all but the simplest models. In cases where the numerical substructure poses no harsh stability condition, it is shown that the Newmark explicit method offers advantages of speed and accuracy. Where the stability limit of an explicit method cannot be met, one of the several alternatives may be used, such as Chang's modified Newmark scheme or the α‐operator splitting method. Appropriate methods of actuator delay compensation are also discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents real‐time hybrid earthquake simulation (RTHS) on a large‐scale steel structure with nonlinear viscous dampers. The test structure includes a three‐story, single‐bay moment‐resisting frame (MRF), a three‐story, single‐bay frame with a nonlinear viscous damper and associated bracing in each story (called damped braced frame (DBF)), and gravity load system with associated seismic mass and gravity loads. To achieve the accurate RTHS results presented in this paper, several factors were considered comprehensively: (1) different arrangements of substructures for the RTHS; (2) dynamic characteristics of the test setup; (3) accurate integration of the equations of motion; (4) continuous movement of the servo‐controlled hydraulic actuators; (5) appropriate feedback signals to control the RTHS; and (6) adaptive compensation for potential control errors. Unlike most previous RTHS studies, where the actuator stroke was used as the feedback to control the RTHS, the present study uses the measured displacements of the experimental substructure as the feedback for the RTHS, to enable accurate displacements to be imposed on the experimental substructure. This improvement in approach was needed because of compliance and other dynamic characteristics of the test setup, which will be present in most large‐scale RTHS. RTHS with ground motions at the design basis earthquake and maximum considered earthquake levels were successfully performed, resulting in significant nonlinear response of the test structure, which makes accurate RTHS more challenging. Two phases of RTHS were conducted: in the first phase, the DBF is the experimental substructure, and in the second phase, the DBF together with the MRF is the experimental substructure. The results from the two phases of RTHS are presented and compared with numerical simulation results. An evaluation of the results shows that the RTHS approach used in this study provides a realistic and accurate simulation of the seismic response of a large‐scale structure with rate‐dependent energy dissipating devices. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
This paper focuses on the development of a linear analytical model (even though servo‐hydraulic actuation systems are inherently non‐linear, especially for large amplitude simulations — near the performance capacity of the system — linearized models proved experimentally to be quite effective overall in capturing the salient features of shaking table dynamics) of a uni‐axial, servo‐hydraulic, stroke controlled shaking table system by using jointly structural dynamics and linear control theory. This model incorporates the proportional, integral, derivative, feed‐forward, and differential pressure gains of the control system. Furthermore, it accounts for the following physical characteristics of the system: time delay in the servovalve response, compressibility of the actuator fluid, oil leakage through the actuator seals and the dynamic properties of both the actuator reaction mass and test structure or payload. The proposed model, in the form of the total shaking table transfer function (i.e. between commanded and actual table motions), is developed to account for the specific characteristics of the Rice University shaking table. An in‐depth sensitivity study is then performed to determine the effects of the table control parameters, payload characteristics, and servovalve time delay upon the total shaking table transfer function. The sensitivity results reveal: (a) a potential strong dynamic interaction between the oil column in the actuator and the payload, and (b) the very important effect of the servovalve time delay upon the total shaking table transfer function. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

16.
A series of large‐scale real‐time hybrid simulations (RTHSs) are conducted on a 0.6‐scale 3‐story steel frame building with magneto‐rheological (MR) dampers. The lateral force resisting system of the prototype building for the study consists of moment resisting frames and damped brace frames (DBFs). The experimental substructure for the RTHS is the DBF with the MR dampers, whereas the remaining structural components of the building including the moment resisting frame and gravity frames are modeled via a nonlinear analytical substructure. Performing RTHS with an experimental substructure that consists of the complete DBF enables the effects of member and connection component deformations on system and damper performance to be accurately accounted for. Data from these tests enable numerical simulation models to be calibrated, provide an understanding and validation of the in‐situ performance of MR dampers, and a means of experimentally validating performance‐based seismic design procedures for real structures. The details of the RTHS procedure are given, including the test setup, the integration algorithm, and actuator control. The results from a series of RTHS are presented that includes actuator control, damper behavior, and the structural response for different MR control laws. The use of the MR dampers is experimentally demonstrated to reduce the response of the structure to strong ground motions. Comparisons of the RTHS results are made with numerical simulations. Based on the results of the study, it is concluded that RTHS can be conducted on realistic structural systems with dampers to enable advancements in resilient earthquake resistant design to be achieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
In this paper, we propose a new actuator control algorithm that achieves the design flexibility, robustness, and tracking accuracy to give real‐time hybrid‐simulation users the power to achieve highly accurate and robust actuator control. The robust integrated actuator control (RIAC) strategy integrates three key control components: loop shaping feedback control based on H optimization, a linear‐quadratic‐estimation block for minimizing noise effect, and a feed‐forward block that reduces small residual delay/lag. The combination of these components provides flexible controller design to accommodate setup limits while preserving the stability of the H algorithm. The efficacy of the proposed strategy is demonstrated through two illustrative case studies: one using large capacity but relatively slow actuator of 2500 kN and the second using a small‐scale fast actuator. Actuator tracking results in both cases demonstrate that the RIAC algorithm is effective and applicable for different setups. Real‐time hybrid‐simulation validation is implemented using a three‐DOF building frame equipped with a magneto‐rheological damper on both setups. Results using the two very different physical setups illustrate that RIAC is efficient and accurate. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A new approach to dynamic force control of mechanical systems, applicable in particular to frame structures, over frequency ranges spanning their resonant frequencies is presented. This approach is implemented using added compliance and displacement compensation. Hydraulic actuators are inherently velocity sources, that is, an electrical signal regulates their velocity response. Such systems are therefore by nature high‐impedance (mechanically stiff) systems. In contrast, for force control, a force source is required. Such a system logically would have to be a low‐impedance (mechanically compliant) system. This is achieved by intentionally introducing a flexible mechanism between the actuator and the structure to be excited. In addition, in order to obtain force control over frequencies spanning the structure's resonant frequency, a displacement compensation feedback loop is needed. The actuator itself operates in closed‐loop displacement control. The theoretical motivation, as well as the laboratory implementation of the above approach is discussed along with experimental results. Having achieved a means of dynamic force control, it can be applied to various experimental seismic simulation techniques such as the effective force method and the real‐time dynamic hybrid testing method. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
This paper presents a detailed analysis of a real‐time pseudodynamic test system using a system transfer function. The analysis considers the actuator control scheme, the dynamics of the actuator, test structure, and actuator reaction frame, the influence of actuator time delay on response computation, and methods to compensate for the time‐lag errors. It has been observed that the system can achieve an excellent performance with optimum control gains. The two error‐compensation methods presented here are also proven to be effective. Further, it has been demonstrated that the adverse effect of the inertia force developed by the test structure can be corrected for during a real‐time test, and that the influence of the reaction frame flexibility is small when the frame is reasonably massive and stiff as compared to the test structure. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

20.
基于虚拟振动台的实时耦联动力仿真试验   总被引:1,自引:1,他引:0  
实时耦联动力试验(RTDHT)是一种将物理模型试验与数值求解计算实时耦联在一起的新型结构动力试验方法.本文采用SIMULINK对液压伺服振动台系统进行了仿真,建立虚拟振动台模型对真实振动台进行离线调试.并提出基于虚拟振动台进行实时耦联动力仿真试验,从而对真实实时耦联动力试验进行指导的思想.仿真结果表明,虚拟振动台可以很好地仿真真实振动台的动力特性,离线调试结果应用于真实振动台能够得到优良的控制性能;基于虚拟振动台的实时耦联动力仿真试验能够反映真实实时耦联动力试验中存在的时滞以及由此而可能导致的系统失稳问题.采用预测补偿算法对时滞进行了补偿,结果表明补偿算法消除了时滞的影响,试验系统稳定且试验结果与数值计算结果吻合得较好.基于虚拟振动台对实时耦联动力试验进行研究,既能对真实试验提出指导又可避免试验系统失稳对设备的损害,是一种实用且必要的研究手段.  相似文献   