首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
提出了连排钢管混凝土柱带钢板耗能键组合剪力墙,它由钢管混凝土连排柱、柱间钢板耗能键、钢板耗能键外包混凝土条带三种单元组合而成。进行了4个不同设计参数试件的低周反复荷载试验研究。分析了各试件的承载力、刚度及其退化过程、滞回特性、延性和破坏特征,探讨了分灾耗能机制。研究表明:连排钢管混凝土柱带钢板耗能键组合剪力墙,承载力较大,后期刚度较稳定;混凝土条带在开裂与闭合过程中消耗地震能量,钢板耗能键通过弯剪变形消耗地震能量,钢管与混凝土条带共同工作协同耗能,具有良好的抗震耗能机制;这种新型组合剪力墙具有较强综合抗震耗能能力。  相似文献   

2.
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete(SRC) columns, steel plate(SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carried out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens(designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out; they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP’s to repair a deformed wall is a practicable technique.  相似文献   

3.
In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a double composite shear wall; the first composite being the use of three different force systems, CFT, steel truss and shear wall, and the second the use of two different materials, steel and concrete. Three 1/5 scaled experimental specimens: a traditional RC shear wall, a shear wall with CFT columns, and a shear wall with CFT columns and concealed steel trusses, were tested under cyclic loading and the seismic performance indices of the shear walls were comparatively analyzed. Based on the data from these experiments, a thorough elastic-plastic finite element analysis and parametric analysis of the new shear walls were carried out using ABAQUS software. The finite element results of deformation, stress distribution, and the evolution of cracks in each phase were compared with the experimental results and showed good agreement. A mechanical model was also established for calculating the load-carrying capacity of the new composite shear walls. The results show that this new type of shear wall has improved seismic performance over the other two types of shear walls tested.  相似文献   

4.
圆钢管混凝土边框剪力墙抗震性能试验研究   总被引:1,自引:0,他引:1  
圆钢管混凝土边框剪力墙是在普通混凝土剪力墙基础上研发的一种新型组合剪力墙。其将圆钢管混凝土柱和普通混凝土剪力墙进行了优势组合,形成多道抗震防线。为了解该组合剪力墙的抗震性能,进行了3个1/5缩尺试件的低周反复荷载试验,其中包括1个圆钢管混凝土柱框架结构、1个普通混凝土剪力墙和1个圆钢管混凝土边框剪力墙。在试验研究基础上,分析了圆钢管混凝土边框剪力墙的承载力、刚度及其退化过程、延性、滞回特性、耗能能力及破坏特征。研究表明:圆钢管混凝土边框剪力墙的抗震性能比普通混凝土剪力墙显著提高,且其承载力、抗震耗能能力均高于圆钢管混凝土柱框架和普通混凝土剪力墙承载力、抗震耗能能力之和,可用于高层和超高层建筑的抗震设计。  相似文献   

5.
圆钢管混凝土边框内藏桁架剪力墙是一种新型组合剪力墙.为了解这种剪力墙的抗震性能,进行了 3个1/5缩尺试件的低周反复荷载试验.3个试件中,1个为圆钢管混凝土柱框架结构,1个为圆钢管混凝土边框-钢桁架结构,1个为圆钢管混凝土边框内藏钢桁架剪力墙.基于试验,对比分析了各试件的承载力、刚度及其退化过程、滞回特性、耗能能力及破...  相似文献   

6.
为进一步研究真实火灾工况下钢管混凝土组合框架的抗火性能,基于有限元软件ABAQUS建立了单层单跨圆形钢管混凝土柱-组合梁平面框架经历火灾全过程的数值分析模型。通过合理选取热工参数,进行了组合框架在ISO-834标准升降温曲线下的热传分析,研究了组合框架钢管混凝土柱与组合梁截面温度场的变化规律;在热传模型的基础上,通过合理选取材料本构模型、单元类型、边界条件以及网格划分等,对经历常温加载、升温、降温以及火灾后的钢管混凝土柱-组合梁平面框架的力学性能进行初步探讨。结果表明,由于钢筋混凝土楼板在受火过程中的吸热与约束作用使组合框架在受火后仍具有较高承栽力。该方法可进一步完善钢管混凝土结构抗火分析理论,也可供实际工程应用参考。  相似文献   

7.
为进一步改善混凝土核心简的抗震性能,本文提出了钢管混凝土叠合柱边框内藏钢桁架组合核心筒.进行了2个1/6缩尺的核心筒模型在低周反复荷载下的抗震性能试验研究,1个为钢管混凝土叠合柱边框毛组合核心筒,1个为钢管混凝土叠合柱边框内藏钢桁架组合核心筒.通过试验,对比分析了2个核心简的承载力、延性、刚度及其衰减、滞回特性、耗能能力及破坏特征,给出了钢管混凝土叠合柱边框内藏钢桁架组合核心筒的承载力计算模型,计算结果与实测值符合较好.研究表明,钢管混凝土叠合柱边框内藏钢桁架组合核心筒与钢管混凝土叠合柱边框组合核心筒相比,其抗震性能明显提高.  相似文献   

8.
在大连国际会议中心核心筒墙体抗震设计中,采用了一种钢管混凝土叠合边框墙肢内藏钢板、连梁内藏钢桁架的组合双肢剪力墙。为研究其抗震性能,进行了1个1/7缩尺的这种新型组合双肢剪力墙模型的低周反复荷载试验,分析了其承载力、延性、刚度及其退化、滞回特性、耗能能力和破坏特征,重点研究了钢管混凝土叠合边框、墙肢内藏钢板、连梁内藏钢桁架之间的共同工作性能。研究表明:内藏钢板-钢桁架可显著提高钢管混凝土叠合边框双肢剪力墙的承载力和延性性能;钢管混凝土叠合边框可充分发挥其承载力高、不易开裂、延性好的优势。文中提出了该新型组合双肢剪力墙的承载力计算模型,计算结果与实测结果符合较好。  相似文献   

9.
The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible out-of-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at corners were shown to be an effective way to increase the energy dissipation capacity of CSPSWs.  相似文献   

10.
钢管混凝土边框高强混凝土组合剪力墙抗震性能试验研究   总被引:6,自引:1,他引:5  
钢管混凝土边框组合剪力墙是一种新型组合剪力墙。本文进行了2个1/4缩尺的高强混凝土剪力墙模型的低周反复荷载试验,模型1为普通钢筋混凝土剪力墙,模型2为钢管混凝土边框组合剪力墙。在试验研究基础上,对比分析它们的承载力、延性、刚度及其衰减过程、滞回特性、耗能能力及破坏特征,建立了组合剪力墙的承载力计算模型,计算结果与实测结果符合较好。研究表明,钢管混凝土边框高强混凝土组合剪力墙与普通剪力墙相比抗震性能显著提高。  相似文献   

11.
张家广  吴斌  梅洋 《地震学刊》2014,(5):637-642
提出了一种既有钢筋混凝土框架结构的抗震加固方法,该法采用防屈曲支撑提高框架结构体系的水平承载力和耗能能力,利用外包钢进一步提高柱子的抗弯和抗剪承载力。采用开源有限元程序OpenSees,分别建立空钢筋混凝土框架和防屈曲支撑加固钢筋混凝土框架的分析模型,对2榀钢筋混凝土框架的抗震性能进行模拟。防屈曲支撑采用了弹塑性桁架单元模型,加固框架柱混凝土考虑了外包钢的约束作用。将分析结果与拟静力试验结果进行比较,以检验分析模型的准确性,以及研究防屈曲支撑和外包钢对混凝土框架抗震性能的影响。分析结果表明,数值模拟与试验结果吻合较好,验证了基于OpenSees建立的数值模型的准确性;外包钢有效改善了框架柱的抗弯承载力和变形能力;防屈曲支撑显著提高了加固框架体系的水平刚度、水平承载力和耗能能力。  相似文献   

12.
Reinforced concrete (RC) frame structures are one of the mostly common used structural systems, and their seismic performance is largely determined by the performance of columns and beams. This paper describes horizontal cyclic loading tests often column and three beam specimens, some of which were designed according to the current seismic design code and others were designed according to the early non-seismic Chinese design code, aiming at reporting the behavior of the damaged or collapsed RC frame strctures observed during the Wenchuan earthquake. The effects of axial load ratio,shear span ratio, and transverse and longitudinal reinforcement ratio on hysteresis behavior, ductility and damage progress were incorporated in the experimental study. Test results indicate that the non-seismically designed columns show premature shear failure, and yield larger maximum residual crack widths and more concrete spalling than the seismically designed columns. In addition, longitudinal steel reinforcement rebars were severely buckled. The axial load ratio and shear span ratio proved to be the most important factors affecting the ductility, crack opening width and closing ability, while the longitudinal reinforcement ratio had only a minor effect on column ductility, but exhibited more influence on beam ductility. Finally, the transverse reinforcement ratio did not influence the maximum residual crack width and closing ability of the seismically designed columns.  相似文献   

13.
设置防屈曲支撑的钢管混凝土框架是一种新型钢管混凝土减震结构。采用有限元软件Opensees对设置防屈曲支撑的单层单跨钢管混凝土减震框架进行数值模拟,研究了框架梁柱线刚度比、防屈曲支撑初始刚度以及钢管混凝土柱轴压比等设计参数对该减震结构抗震性能的影响。研究结果表明:1数值模拟和试验结果吻合较好,验证了有限元模型的正确性;2梁柱线刚度比在0.1~0.3之间变化时,钢管混凝土减震框架的抗震性能较好;3BRB耗能支撑的初始刚度K1在40~80kN/mm变化时,减震框架的耗能减震效应较明显;4在合理的钢管混凝土柱轴压比范围内,当轴压比较大时,在钢管混凝土框架中设置防屈曲支撑能明显地提高结构的耗能能力和改善结构的强度退化现象。  相似文献   

14.
A new type of hybrid coupled wall system, consisting of rolled steel coupling beams, reinforced concrete (RC) wall piers, and concrete‐filled tube (CFT) short columns, is introduced. In this new system, the bases of the wall piers are connected to the base beams only through CFT short columns, unlike conventional coupled walls. Yield occurs in the coupling beams and the short columns; hence, in the RC wall piers, only minimum cracking appears. A total of four subassembly specimens, designed to fail in various collapse mechanisms, were cyclically loaded under constant axial force. A benchmark specimen showed ductile behavior with large energy dissipation until fracture occurred in the coupling beam. In the specimen designed to fail in shear in its CFT, substantial axial shortening was observed, but the overall behavior was ductile. Behavior of specimens with small amounts of section steel in the wall panel fringe, or with thin wall panels, also showed ductile behavior, but the strength and energy dissipation were significantly smaller than other two specimens. An analytical model was proposed for a frame analysis program using fiber elements to simulate elastic–plastic behavior of the system. Design methods to prevent shear failure of CFT and RC panels are suggested using the analytical and test results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
高轴压比下钢管混凝土边框组合剪力墙抗震性能试验研究   总被引:8,自引:1,他引:7  
钢管混凝土边框组合剪力墙是一种适用于高层及超高层建筑的新型组合剪力墙。轴压比是影响剪力墙抗震性能的一个主要因素,高层建筑底部轴压比较大。本文进行了1/4缩尺的1个普通钢筋混凝土剪力墙模型和1个钢管混凝土边框组合剪力墙模型在高轴压比下的低周反复荷载试验。在试验研究基础上,对比分析了剪力墙的承载力、延性、刚度及其衰减过程、滞回特性、耗能能力及破坏特征,建立了钢管混凝土边框组合剪力墙的承载力计算模型,计算结果与实测结果符合较好。研究表明:在高轴压比下钢管混凝土边框组合剪力墙与普通剪力墙相比抗震性能显著提高。  相似文献   

16.
The replaceable coupling beam (RCB) is an innovative structural component developed to increase the seismic resilience of reinforced concrete (RC) shear wall structures. In this study, two 1/5‐scale 5‐story 3‐dimensional RC shear wall structures—one with conventional RC coupling beams and the other with RCBs—were designed, constructed, and tested on a shaking table. The failure pattern, dynamic properties, and structural responses, including the acceleration, displacement, story force, and strain responses, of the 2 structures are compared under earthquake excitations. The test results demonstrate that the seismic performance of the structure with RCBs was improved when RCBs were working compared with the structure with conventional RC coupling beams. In addition, the replaceable devices suffering the severe damage during an earthquake can be conveniently replaced after the earthquake. However, after the sudden failure of RCBs during the severe earthquakes, the inter‐story drift and floor acceleration of the structure with RCBs became larger. The design and manufacture quality of RCBs should be improved to avoid the sudden failure. Then, numerical models for the test structures were established using the commercial software PERFORM‐3D. Numerical simulations of the tests were conducted. The simulation results correspond well with the experimental results, thus verifying the accuracy of the numerical models. The RC shear wall structure installed with RCBs can be applied as a new type of earthquake‐resilient structure in engineering practice.  相似文献   

17.
钢管混凝土边框钢板剪力墙是一种新型抗震剪力墙,为了比较不同构造措施对该新型剪力墙抗震性能的影响,进行了3个剪跨比为1.5的钢管混凝土边框钢板剪力墙低周反复荷载试验。其中,试验模型1为墙体钢板与边框柱钢管焊接,试验模型2为墙体钢板与边框柱钢管螺栓连接,试验模型3为墙体钢板开孔并与边框柱钢管焊接。通过试验研究,比较了各剪力墙的破坏特征、滞回特性、承载力、刚度、延性以及耗能能力。结果表明:在墙体钢板与边框柱钢管的连接方式中,采用焊接或栓接对剪力墙的整体性能影响不大;与普通钢管混凝土边框钢板剪力墙相比,钢板开孔钢管混凝土边框钢板剪力墙在开孔率不大的情况下,其承载力、延性、刚度和耗能能力没有明显变化。  相似文献   

18.
SRC框格复合墙是在普通RC密肋复合墙基础上结合型钢混凝土概念而提出来的一种复合墙板,以轻钢龙骨代替框格内原有纵向受力钢筋,通过焊接或螺栓连接在梁柱轻钢龙骨节点处实现刚性或半刚性连接.在SRC框格复合墙模型试验基的础上,利用ANSYS程序对墙体受力过程进行了非线性有限元分析,提出了SRC框格复合墙抗剪承载力的实用计算公式,并对框格含钢率、轻钢强度等影响因素进行了有限元分析.研究结果表明:所提出的SRC框格复合墙抗剪承载力计算公式,与非线性有限元计算结果吻合较好,能够适应框格含钢率等不同因素变化的计算精度要求;提高肋梁中轻钢强度或含钢率可以有效提高墙体抗剪承载力,而不宜单独采用提高混凝土强度的方法.  相似文献   

19.
To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens were designed and tested under low cyclically lateral load. The effects of the axial load ratio and volumetric stirrup ratio were studied on the characteristics of the frame joint performance including crack pattern, failure mode, ductility, energy dissipation capacity, strength degradation and rigidity degradation. It was found that all joint specimens behaved in a ductile manner with flexural-shear failure in the joint core region while plastic hinges appeared at the beam ends. The ductility and energy absorption capacity of joints increased as the axial load ratio decreased and the volumetric stirrup ratio increased. The displacement ductility coefficient and equivalent damping coefficient of the joints fell between the corresponding coefficients of the steel reinforced concrete (SRC) frame joint and RC frame joint. The axial load ratio and volumetric stirrup ratio have less influence on the strength degradation and more influence on the stiffness degradation. The stiffness of the joint degrades more significantly for a low volumetric stirrup ratio and high axial load ratio. The characteristics obtained from the SRUHSC composite frame joint specimens with better seismic performance may be a useful reference in future engineering applications.  相似文献   

20.
The steel tube‐reinforced concrete (ST‐RC) composite column is a novel type of composite column, which consists of a steel tube embedded in RC. In this paper, the seismic behavior of ST‐RC columns is examined through a series of experiments in which 10 one‐third scale column specimens were subjected to axial forces and lateral cyclic loading. The test variables include the axial force ratio applied to the columns and the amount of transverse reinforcement. All specimens failed in a flexural mode, showing stable hysteresis loops. Thanks to the steel tube and the high‐strength concrete it is filled with, the ST‐RC column specimens had approximately 30% lower axial force ratios and 22% higher maximum bending moments relative to the comparable RC columns when subjected to identical axial compressive loads. The amount of transverse reinforcement made only a small difference to the lateral load‐carrying capacity but significantly affected the deformation and energy dissipation capacity of the ST‐RC columns. The specimens that satisfied the requirements for transverse reinforcement adopted for medium ductile RC columns as specified by the Chinese Code for Seismic Design of Buildings (GB 50011‐2010) and EuroCode 8 achieved an ultimate drift ratio of around 0.03 and a displacement ductility ratio of approximately 5. The design formulas used to evaluate the strength capacity of the ST‐RC columns were developed on the basis of the superposition method. The predictions from the formulas showed good agreement with the test results, with errors no greater than 10%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   