首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
In this paper, the efficiency of providing elastic‐gap devices (EGDs) to improve the performance of seismic‐isolated bridges (SIBs) in near‐fault (NF) zones is investigated. The device is primarily made of an assembly of circular rubber bearings and steel plates to provide additional elastic stiffness to the SIB upon closure of a gap. The EDG is intended to function at two performance levels under service and maximum considered design level (MCDL) NF earthquakes to reduce isolator displacements while keeping the substructure forces at reasonable levels. A parametric study, involving more than 500 nonlinear time history analyses of realistic and simplified structural models of typical SIBs, is conducted using simulated and actual NF ground motions to investigate the applicability of the proposed solution. It is found that providing EGD is beneficial for reducing the isolator displacements to manageable ranges for SIBs subjected to MCDL NF ground motions regardless of the distance from the fault and characteristics of the isolator. It is also found that providing EGD resulted in an improved performance of the isolators in terms of the reduction of heat generated by the isolators. Further analyses conducted using a realistic structural model of an existing bridge and five NF earthquakes confirmed that EGD may be used to reduce the displacement of the isolators while keeping the substructure base shear forces at reasonable ranges for SIBs located in NF zones. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
A broader consensus on the number of ground motions to be used and the method of scaling to be adopted for nonlinear response history analysis (RHA) of structures is yet to be reached. Therefore, in this study, the effects of selection and scaling of ground motions on the response of seismically isolated structures, which are routinely designed using nonlinear RHA, are investigated. For this purpose, isolation systems with a range of properties subjected to bidirectional excitation are considered. Benchmark response of the isolation systems is established using large sets of unscaled ground motions systematically categorized into pulse-like, non-pulse-like, and mixed set of motions. Different subsets of seven to 14 ground motions are selected from these large sets using (a) random selection and (b) selection based on the best match of the shape of the response spectrum of ground motions to the target spectrum. Consequences of weighted scaling (also commonly referred to as amplitude scaling or linear scaling) as well as spectral matching are investigated. The ground motion selection and scaling procedures are evaluated from the viewpoint of their accuracy, efficiency, and consistency in predicting the benchmark response. It is confirmed that seven time histories are sufficient for a reliable prediction of isolation system displacement demands, for all ground motion subsets, selection and scaling procedures, and isolation systems considered. If ground motions are selected based on their best match to the shape of the target response spectrum (which should be preferred over randomly selected motions), weighted scaling should be used if pulse-like motions are considered, either of weighted scaling or spectral matching can be used if non-pulse-like motions are considered, and an average of responses from weighted-scaled and spectrum-matched ground motions should be used for a mixed set of motions. On the other hand, the importance of randomly selected motions in representing inherent variability of response is recognized and it is found that weighted scaling is more appropriate for such motions.  相似文献   

3.
In this paper, the effect of lead core heating and associated strength deterioration on the seismic response of bridges isolated with lead rubber bearings (LRB) is investigated as a function of the characteristics of the isolator and near fault ground motions with forward rupture directivity effect. Furthermore, the ability of bounding analyses to provide a design envelope for maximum isolator force and maximum isolator displacement is verified. For this purpose, a series of nonlinear dynamic analyses are conducted for LRB isolated bridges where both deteriorating and non‐deteriorating force‐deformation relationship of LRB were employed. The analyses are performed for both simulated and recorded ground motions. It is found that while the temperature rise in the lead core generally increases with increasing magnitude and number of near fault ground motion velocity pulses, it decreases with larger distances from the fault. It is also found that bounding analysis method provides conservative (envelope) estimates of maximum isolator displacement and maximum isolator force for design purposes that fulfill its intended purpose. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Researchers and practitioners in earthquake engineering have recognized geographic information systems (GIS) to be a significant tool in modeling spatial phenomenon related to hazard and risk. GIS, as an engineering tool, has been primarily used for its spatial data storing and presentation features. Models are often simplified to be more compatible with the light computational capabilities of many GIS. If not simplified, heavy computations are generally performed external to the GIS. A prototype vector-based GIS was developed that employs a rigorous approach to Newmark's displacement method for assessing earthquake triggered landslide hazards. The rigorous Newmark's analysis provides desirable flexibility by allowing input of actual ground motions. The prototype hazard GIS incorporates a popular shot filtered noise technique for generating artificial ground motions. The rigorous approach was compared to a popular simplified approach for computing Newmark displacements. Distribution of regional displacements was found to be similar with the simplified approach giving more and larger extreme displacements. The rigorous approach is suitable for large scales to model various seismic scenarios and their effect on seismically induced landslide potential.  相似文献   

5.
A simplified response spectrum superposition method has been generalized for the dynamic analysis of the multistoried building-soil response to earthquake ground motions via Fourier-transformed frequency domain. It involves the “scaling” of the Fourier amplitudes of the freefield translational and rocking motions to account for the soil-structure interaction effects, and then analyzing the building as fixed at the base. Envelopes of peak displacements, shear forces and overturning moments in the building are illustrated in terms of the order statistics of the response peaks.  相似文献   

6.
This study focuses on the response of seismic isolated bridges subjected to near-field ground motions with distinct pulse type behavior in terms of maximum isolator displacements (MIDs) and maximum isolator forces (MIFs) transferred to the substructure. The employed isolation systems are composed of lead rubber bearings (LRBs) with bi-linear force-deformation relations that consider cycle-to-cycle deterioration in the yield strength of the LRBs due to heating of the lead core. MIDs and MIFs with due consideration of cycle-to-cycle deterioration are compared with that of non-deteriorating ones. Bounding analyses are also performed for comparison purposes. Nonlinear response history analyses are conducted with two bins of ground motions recorded at different soil conditions to investigate the effect of ground motion characteristics. Results indicate that MIDs are overestimated by lower bound analyses when seismic isolated bridges are subjected to near-field motions with high velocity pulses especially for the bearings with higher Q/W ratios.  相似文献   

7.
A retrofit procedure for existing buildings called the "weakening and damping technique" (WED) is presented in this paper. Weakening of structures can limit the maximum response accelerations during severe ground motions, but leads to an increase in the displacements or inter-story drifts. Added damping by using viscous dampers, on the other hand, reduces the inter-story drifts and has no significant effect on total accelerations, when structures behave inelastically. The weakening and damping technique addresses the two main causes for both structural and nonstructural damage in structures. The weakening retrofit is particularly suitable for structures that have overstressed components and weak brittle components. In this paper, the advantages of the WeD are verified by nonlinear dynamic analysis and simplified spectral approach that has been modified to fit structures with additional damping devices. A hospital structure located in the San Femando Valley in California is selected as a case study. The results from both analyses show that the retrofit solution is feasible to reduce both structural acceleration and displacement. A sensitivity analysis is also carried out to evaluate the effectiveness of the retrofitting method using different combinations of performance thresholds in accelerations and displacements through fragility analysis.  相似文献   

8.
This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. Three-dimensional models of 4-, 8-, and 12-story base-isolated buildings with nonlinear effects in the isolation system and the superstructure are investigated, and nonlinear response history analysis is carried out. The bounding values of isolation system properties that incorporate the aging effect of isolators are also taken into account, as is the current state of practice in the design and analysis of base-isolated buildings. The response indicators of the buildings are studied for near-fault and far-fault motions weight-scaled to represent the design earthquake (DE) level and the risk-targeted maximum considered earthquake (MCER) level. Results of the nonlinear response history analyses indicate no structural damage under DE-level motions for near-fault and far-fault motions and for MCER-level far-fault motions, whereas minor structural damage is observed under MCER-level near-fault motions. Results of the base-isolated buildings are compared with their fixed-base counterparts. Significant reduction of the superstructure response of the 12-story base-isolated building compared to the fixed-base condition indicates that base isolation can be effectively used in taller buildings to enhance performance. Additionally, the applicability of a rigid superstructure to predict the isolator displacement demand is also investigated. It is found that the isolator displacements can be estimated accurately using a rigid body model for the superstructure for the buildings considered.  相似文献   

9.
本文通过弹性和弹塑性时程分析,研究了水平地震作用下梁铰型屈服RC框架模型结构的楼层屈服剪力系数、基本自振周期、楼层数3个因素对弹塑性位移增大系数的影响,通过非线性回归分析给出了弹塑性层间位移增大系数经验公式;通过分析滞回耗能沿楼层高度的分布,初步确定了梁铰型屈服RC框架结构的薄弱楼层位置;基于结构损伤分析,讨论了抗震规范中RC框架结构弹塑性层间位移角限值的水准。  相似文献   

10.
Numerical simulations are performed to assess the effects of near-fault ground motions on base-isolated buildings that consist of either lead-rubber (LRB) or friction-pendulum system (FPS) bearings in addition to supplemented viscous dampers. While LRB and FPS isolation systems have been applied for a number of years, the addition of supplemental damping devices is being currently considered for strong ground motions to reduce the isolator displacements. However, the main problem in this case is that the addition of damping may increase both internal deformation and absolute accelerations of the superstructure and thus may defeat many of the gains for which base isolation is intended. In the present paper, a detailed and systematic investigation on the performance of LRB and FPS isolation systems, provided with supplemental viscous damping under the effect of near-fault ground motions, has been carried out by using commercial finite element software.  相似文献   

11.
The accuracy of the three‐dimensional modal pushover analysis (MPA) procedure in estimating seismic demands for unsymmetric‐plan buildings due to two horizontal components of ground motion, simultaneously, is evaluated. Eight low‐and medium‐rise structures were considered. Four intended to represent older buildings were designed according to the 1985 Uniform Building Code, whereas four other designs intended to represent newer buildings were based on the 2006 International Building Code. The median seismic demands for these buildings to 39 two‐component ground motions, scaled to two intensity levels, were computed by MPA and nonlinear response history analysis (RHA), and then compared. Even for these ground motions that deform the buildings significantly into the inelastic range, MPA offers sufficient degree of accuracy. It is demonstrated that PMPA, a variant of the MPA procedure, for nonlinear systems is almost as accurate as the well‐known standard response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative to nonlinear RHA, whereby seismic demands can be estimated directly from the (elastic) design spectrum. In contrast, the nonlinear static procedure specified in the ASCE/SEI 41‐06 Standard is demonstrated to grossly underestimate seismic demands for some of the unsymmetric‐plan buildings considered. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
引入非线性动力学理论和混沌时间序列分析方法考察强震地面运动加速度时程的非线性特征。首先采用功率谱分析法、主成份分析法和Cao方法定性判断地震动加速度时程具有混沌特性,然后应用混沌时间序列分析方法定量计算了30条地震动加速度时程的三个非线性特征参数。计算表明,这些地震动时程的关联维数为2.0~4.0的分数维,Kolmogorov熵K2为大于零的有限正值,最大Lyapunov指数在o~i.0之间。结果说明,强震地面运动具有混沌特性,地震动的高度不规则和复杂性是地震过程强非线性的反映。  相似文献   

13.
This paper investigates the response of lead rubber bearings (LRBs) under bidirectional earthquake excitations when lead core heating effect is of concern. For this purpose, a series of nonlinear response history analyses were conducted with a bilinear force‐deformation relation for LRBs. In the considered bilinear representation, the strength of LRBs deteriorates because of lead core heating under cyclic motions. Response of LRBs was studied in terms of maximum isolator displacements (MIDs) and maximum lead core temperature as a function of isolator characteristics (characteristic strength to weight ratio, Q/W, and post‐yield isolation period, T). Nonlinear response history analyses were performed using two sets of ground motions clustered according to their soil classifications. To quantify the interacted effects of coupled analysis and lead core heating on MID, unidirectional analyses were also performed. Furthermore, the efficacy of equivalent lateral force procedure in estimating the MID of LRBs was also tested for the cases in which temperature‐dependent behavior of LRBs was considered. The results demonstrate that the temperature rises in the lead core of LRBs in bidirectional analyses are approximately 50% higher than that of unidirectional ones. It decreases with increasing Q/W ratio and T. It is also revealed that equivalent lateral force procedure gives close estimations for MID with some overestimation even for temperature‐dependent behavior of LRBs. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
A procedure for developing equations that estimate the isolator displacement due to strong ground motion is applied to buildings isolated with the friction pendulum system. The resulting design equations, based on rigorous non‐linear analysis, offer an alternative to the iterative equivalent‐linear methods used by current U.S. building codes. The governing equations of the system are reduced to a form such that the median normalized displacement of the system due to an ensemble of ground motions is found to depend on only the isolation period—a function of the curvature of the isolator—and the friction force at incipient slip normalized by peak ground velocity. The normalization is effective in minimizing the dispersion of the normalized displacement for an ensemble of ground motions, implying that the median normalized displacement is a reliable estimate of response. The design equations reflect the significant (20 to 38%) increase in displacement when the excitation includes two lateral components of ground motion instead of just one component. Equivalent‐linear methods are shown to underestimate by up to 30% the exact median displacement determined by non‐linear response history analysis for one component of ground motion, and building codes include at most a 4.4% increase for a second component. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

16.
基于谐波入射下的波动理论频域精确解,导出线性时域精确解,并在Matlab环境中编制相应的计算程序;选取8个简化的中硬场地剖面,用LSSRLI-1、精确解和SHAKE2000三种方法计算各场地在不同输入条件下的地震反应。结果表明:程序计算所得地表反应谱和土体剪应变分布与SHAKE2000结果一致;LSSRLI-1方法得到的地表反应谱与前二者结果一致;LSSRLI-1方法在某些情况下得到的土体剪应变分布与另外二者结果存在较大偏差,该偏差对地表反应谱有着不可忽略甚至非常显著的影响。  相似文献   

17.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

18.
In the current code requirements for the design of base isolation systems for buildings located at near-fault sites, the design engineer is faced with very large design displacements for the isolators. To reduce these displacements, supplementary dampers are often prescribed. These dampers reduce displacements, but at the expense of significant increases in interstorey drifts and floor accelerations in the superstructure. An elementary analysis based on a simple model of an isolated structure is used to demonstrate this dilemma. The model is linear and is based on modal analysis, but includes the modal coupling terms caused by high levels of damping in the isolation system. The equations are solved by a method that avoids complex modal analysis. Estimates of the important response quantities are obtained by the response spectrum method. It is shown that as the damping in the isolation system increases, the contribution of the modal coupling terms due to isolator damping in response to the superstructure becomes the dominant term. The isolator displacement and structural base shear may be reduced, but the floor accelerations and interstorey drift are increased. The results show that the use of supplemental dampers in seismic isolation is a misplaced effort and alternative strategies to solve the problem are suggested. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

19.
A roller seismic isolation bearing is proposed for use in highway bridges. The bearing utilizes a rolling mechanism to achieve seismic isolation and has a zero post‐elastic stiffness under horizontal ground motions, a self‐centering capability, and unique friction devices for supplemental energy dissipation. The objectives of this research are to investigate the seismic behavior of the proposed bearing using parametric studies (1) with nonlinear response history analysis and (2) with equivalent linear analysis according to the AASHTO guide specifications, and by comparing the results from both analysis methods (3) to evaluate the accuracy of the AASHTO equivalent linear method for predicting the peak displacement of the proposed bearing during an earthquake. Twenty‐eight ground motions are used in the studies. The parameters examined are the sloping angle of the intermediate plate of the bearing, the amount of friction force for supplemental energy dissipation, and the peak ground acceleration levels of the ground motions. The peak displacement and base shear of the bearing are calculated. Results of the studies show that a larger sloping angle does not reduce the peak displacement for most of the parametric combinations without friction devices. However, for parametric combinations with friction devices, it allows for the use of a higher friction force, which effectively reduces the peak displacement, while keeping a self‐centering capability. The AASHTO equivalent linear method may underestimate the peak displacement by as much as 40%. Vertical ground motions have little effect on the peak displacement, but significantly increase the peak base shear. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
近断层地震动中长周期、短持时和高能量的加速度脉冲将对高层摩擦摆基础隔震结构的减震性能产生不利影响,考虑土-结构相互作用(SSI效应)后的隔震结构将产生动力耦合效应,可能进一步放大隔震结构地震响应。为此,通过一幢框架-核心筒高层摩擦摆基础隔震结构的非线性地震响应分析,考察近断层脉冲型地震动作用下框架-核心筒摩擦摆基础隔震结构的层间位移角、楼层加速度和隔震层变形等响应规律,揭示隔震体系的损伤机理。基于集总参数SR (sway-rocking)模型,分析不同场地类别与不同地震动类型对隔震体系动力响应影响规律。结果表明:高层摩擦摆基础隔震结构在近断层脉冲型地震动作用下的减震效果相比普通地震动减震效果变差,楼层剪力、层间位移角和隔震层变形等超越普通地震动作用下的1.5倍;对于Ⅲ和Ⅳ类场地类别,考虑SSI效应使隔震结构的地震响应进一步放大,弹塑性层间位移角随着土质变软增大尤为明显。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号