首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Recharge processes of karst aquifers are difficult to assess given their strong heterogeneity and the poorly known effect of vadose zone on infiltration. However, recharge assessment is crucial for the evaluation of groundwater resources. Moreover, the vulnerability of karst aquifers depends on vadose zone behaviour because it is the place where most contamination takes place. In this work, an in situ experimental approach was performed to identify and quantify flow and storage processes occurring in karst vadose zone. Cave percolation monitoring and dye tracing were used to investigate unsaturated zone hydrological processes. Two flow components (diffuse and quick) were identified and, respectively, account for 66% and 34% of the recharge. Quickflow was found to be the result of bypass phenomenon in vadose zone related to water saturation. We identify the role of epikarst as a shunting area, most of the storage in the vadose zone occurring via the diffuse flow component in low permeability zones. Relationship between rainfall intensity and transit velocity was demonstrated, with 5 times higher velocities for the quick recharge mode than the diffuse mode. Modelling approach with KarstMod software allowed to simulate the hybrid recharge through vadose zone and shows promising chances to properly assess the recharge processes in karst aquifer based on simple physical models.  相似文献   

2.
Soil vapor extraction (SVE) is a prevalent remediation remedy for volatile organic compound (VOC) contaminants in the vadose zone. To support selection of an appropriate condition at which SVE may be terminated for site closure or for transition to another remedy, an evaluation is needed to determine whether vadose zone VOC contamination has been diminished sufficiently to keep groundwater concentrations below threshold values. A conceptual model for this evaluation was developed for VOC fate and transport from a vadose zone source to groundwater when vapor‐phase diffusive transport is the dominant transport process. A numerical analysis showed that, for these conditions, the groundwater concentration is controlled by a limited set of parameters, including site‐specific dimensions, vadose zone properties, and source characteristics. On the basis of these findings, a procedure was then developed for estimating groundwater concentrations using results from the three‐dimensional multiphase transport simulations for a matrix of parameter value combinations and covering a range of potential site conditions. Interpolation and scaling processes are applied to estimate groundwater concentrations at compliance (monitoring) wells for specific site conditions of interest using the data from the simulation results. The interpolation and scaling methodology using these simulation results provides a far less computationally intensive alternative to site‐specific three‐dimensional multiphase site modeling, while still allowing for parameter sensitivity and uncertainty analyses. With iterative application, the approach can be used to consider the effect of a diminishing vadose zone source over time on future groundwater concentrations. This novel approach and related simulation results have been incorporated into a user‐friendly Microsoft® Excel®‐based spreadsheet tool entitled SVEET (Soil Vapor Extraction Endstate Tool), which has been made available to the public.  相似文献   

3.
Low-permeability layers of the vadose zone containing volatile organic compounds (VOCs) may persist as source zones for long time periods and may provide contamination to groundwater. At sites with low recharge rates, where vapor migration is the dominant transport process, the impact of vadose zone sources on groundwater may be difficult to assess. Typical assessment methods include one-dimensional numerical and analytical techniques. The one-dimensional approaches only consider groundwater coupling options through boundary conditions at the water table and may yield artificially high mass flux results when transport is assumed to occur by gas-phase diffusion between a source and an interface with a zero concentration boundary condition. Improvements in mass flux assessments for VOCs originating from vadose zone sources may be obtained by coupling vadose zone gas transport and dissolved contaminant transport in the saturated zone and by incorporating the inherent three-dimensional nature of gas-phase transport, including the potential of density-driven advection. This paper describes a series of three-dimensional simulations using data from the U.S. Department of Energy's Hanford site, where carbon tetrachloride is present in a low-permeability zone about 30 m above the groundwater. Results show that, for most cases, only a relatively small amount of the contaminant emanating from the source zone partitions into the groundwater and that density-driven advection is only important when relatively high source concentrations are considered.  相似文献   

4.
Diminishing rates of subsurface volatile contaminant removal by soil vapor extraction (SVE) oftentimes warrants an in-depth performance assessment to guide remedy decision-making processes. Such a performance assessment must include quantitative approaches to better understand the impact of remaining vadose zone contamination on soil gas and groundwater concentrations. The spreadsheet-based Soil Vapor Extraction Endstate Tool (SVEET) software functionality has recently been expanded to facilitate quantitative performance assessments. The updated version, referred to as SVEET2, includes expansion of the input parameter ranges for describing a site (site geometry, source characteristics, etc.), an expanded list of contaminants, and incorporation of elements of the Vapor Intrusion Estimation Tool for Unsaturated-zone Sources software to provide soil gas concentration estimates for use in vapor intrusion evaluation. As part of the update, SVEET2 was used to estimate the impact of a tetrachloroethene (PCE) vadose zone source on groundwater concentrations, comparing SVEET2 results to field-observed values at an undisclosed site where SVE was recently terminated. PCE concentrations from three separate monitoring wells were estimated by SVEET2 to be within the range of 6.0–6.7 μg/L, as compared to actual field concentrations that ranged from 3 to 11 μg/L PCE. These data demonstrate that SVEET2 can rapidly provide representative quantitative estimates of impacts from a vadose zone contaminant source at field sites. In the context of the SVE performance assessment, such quantitative estimates provide a basis to support remedial and/or regulatory decisions regarding the continued need for vadose zone volatile organic compound remediation or technical justification for SVE termination, which can significantly reduce the cost to complete for a site.  相似文献   

5.
Extreme heterogeneity of karst systems makes them very challenging to study. Various processes within the system affect its global response, usually measured at karst springs. Research conducted in caves provides a unique opportunity for in situ analysis of separate processes in karst underground. The aim of the present study was to research the water and air dynamics within a deep karst system. Air and water basic physical parameters across the Lukina jama–Trojama cave system (?1,431 m) were continuously monitored during a 1‐year period. Recorded hydrograph of the siphon lake at the bottom of the cave was used to interpret the characteristics of an unexplored phreatic/epiphreatic conduit network. Water origin in the siphon was determined based on temperature and electrical conductivity. Air temperature and humidity monitoring revealed a strong inflow of air of sub‐zero temperature into the upper portion of the cave during winter. Cave passage morphology was interpreted as the main determinant of air dynamics, which caused ice to accumulate extensively in the upper portions of the cave and caused the temperature on the top of the homothermic zone to be significantly below the mean outside temperature. Air dynamics also lowered the temperature of water flowing through the cave vadose zone and feeding the phreatic zone of the massif. The pronounced temperature difference between the phreatic zone and the top of the homothermic zone probably contributed to the thermal gradient observed in the cave, which is steeper than in ice‐free caves in the area. Our results enabled the development of a conceptual model that describes coupling between air and water dynamics in the cave system and its surroundings.  相似文献   

6.
Managed aquifer recharge (MAR) provides means to remove natural organic matter (NOM) from surface waters. Recent studies have explored the degree of NOM removal in groundwater. In this study, we further elaborate the NOM removal at a lakeside natural bank infiltration site that functions as a surrogate for MAR. Our objective was to quantify the carbon budget in the aquifer based on concentration measurements of dissolved (in)organic carbon, and the molecular changes in NOM using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). According to the carbon budget, only 25% of the dissolved carbon entering the aquifer was organic, and it predominantly originated from lake water. Of the inorganic majority, on average 40% was produced in the vadose zone above the groundwater table, 31% in the lake bank, 22% in the aquifer as a result of degrading organic matter of lake water, and 7% in the lake. Seasonal concentration variations suggested that the lake bank was the main carbon source in the summer, increasing the carbon concentration of infiltrating lake water, that is, 3.0 mg/L to 7.9 mg/L. FT-ICR MS results showed 4960 to 5330 individual compounds in lake and groundwater. NOM removal in the aquifer was selective: the relative abundance of oxygen-containing species decreased from 75 to 31%, while the relative abundance of sulfur-containing species increased from 15 to 57%. The average molecular weights of both species remained unchanged. The study highlighted the role of lake bank processes and sulfur-containing species in groundwater quality.  相似文献   

7.
Natural source zone depletion (NSZD) refers to processes within chemically impacted vadose and saturated zones that reduce the mass of contaminants remaining in a defined source control volume. Studies of large petroleum hydrocarbon release sites have shown that the depletion rate by vapor phase migration of degradation products from the source control volume through the vadose zone (V‐NSZD) is often considerably higher than the rate of depletion from the source control volume by groundwater flow carrying dissolved petroleum hydrocarbons arising from dissolution, desorption, or back diffusion, and degradation products arising from biodegradation (GW‐NSZD). In this study, we quantified vadose zone and GW‐NSZD at a small unpaved fuel release site in California typical of those in settings with predominantly low permeability media. We estimated vadose zone using a dense network of efflux monitoring locations at four sampling events over 2 years, and GW‐NSZD using groundwater monitoring data downgradient of the source control volume in three depth intervals spanning up to 9 years. On average, vadose zone was 17 times greater than GW‐NSZD during the time interval of comparison, and vadose zone was in the range of rates quantified at other sites with petroleum hydrocarbon releases. Estimating vadose zone and GW‐NSZD rates is challenging but the vadose zone rate is the best indicator of overall source mass depletion, whereas GW‐NSZD rates may be useful as baselines to quantify progress of natural or engineered remediation in portions of the saturated zone in which there are impediments to loss of methane and other gases to the vadose zone.  相似文献   

8.
Understanding the dynamics and mechanisms of soil water movement and solute transport is essential for accurately estimating recharge rates and evaluating the impacts of agricultural activities on groundwater resources. In a thick vadose zone (0–15 m) under irrigated cropland in the piedmont region of the North China Plain, soil water content, matric potential, and solute concentrations were measured. Based on these data, the dynamics of soil water and solutes were analysed to investigate the mechanisms of soil water and solute transport. The study showed that the 0–15‐m vadose zone can be divided into three layers: an infiltration and evaporation layer (0–2 m), an unsteady infiltration layer (2–6 m), and a quasi‐steady infiltration layer (6–15 m). The chloride, nitrate, and sulphate concentrations all showed greater variations in the upper soil layer (0–1 m) compared to values in the deep vadose zone (below 2 m). The average concentrations of these three anions in the deep vadose zone varied insignificantly with depth and approached values of 125, 242, and 116 mg/L. The accumulated chloride, sulphate, and nitrate were 2,179 ± 113, 1,760 ± 383, and 4,074 ± 421 kg/ha, respectively. The soil water potential and solute concentrations indicated that uniform flow and preferential flow both occurred in the deep vadose zone, and uniform flow was the dominant mechanism of soil water movement in this study. The piston‐like flow velocity of solute transport was 1.14 m per year, and the average value of calculated leached nitrate nitrogen was 107 kg/ha?year below the root zone. The results can be used to better understand recharge processes and improve groundwater resources management.  相似文献   

9.
Effective long‐term operation of soil vapor extraction (SVE) systems for cleanup of vadose‐zone sources requires consideration of the likelihood that remediation activities over time will alter the subsurface distribution and configuration of contaminants. A method is demonstrated for locating and characterizing the distribution and nature of persistent volatile organic contaminant (VOC) sources in the vadose zone. The method consists of three components: analysis of existing site and SVE‐operations data, vapor‐phase cyclic contaminant mass‐discharge testing, and short‐term vapor‐phase contaminant mass‐discharge tests conducted in series at multiple locations. Results obtained from the method were used to characterize overall source zone mass‐transfer limitations, source‐strength reductions, potential changes in source‐zone architecture, and the spatial variability and extent of the persistent source(s) for the Department of Energy's Hanford site. The results confirmed a heterogeneous distribution of contaminant mass discharge throughout the vadose zone. Analyses of the mass‐discharge profiles indicate that the remaining contaminant source is coincident with a lower‐permeability unit at the site. Such measurements of source strength and size as obtained herein are needed to determine the impacts of vadose‐zone sources on groundwater contamination and vapor intrusion, and can support evaluation and optimization of the performance of SVE operations.  相似文献   

10.
Currently, vadose zone monitoring is required under the Resource Conservation and Recovery Act (RCRA) only at land treatment facilities. Contaminant leak detection through ground water monitoring is very important, but it is considered to be after the fact. Remedial action costs can be reduced considerably by monitoring the vadose zone for compounds that exhibit high rates of movement. Volatile organic compounds (VOCs) exhibit this property and are present at many municipal landfills, recycling facilities, and treatment storage and disposal facilities (TSDFs). Through the authors'personal experience, it has been noted that gaseous phase transport of VOCs through the vadose zone is at least an order of magnitude greater than advective transport of VOCs in ground water. Therefore, VOCs in soil gas are an effective early warning leak detection parameter. Downward movement of leachate can be intercepted by porous cup lysimeters. Attenuation in the vadose zone slows the apparent movement of contaminants; however, it is only a matter of time before leachate reaches the water table. The authors believe that soil-gas and pore-water monitoring should and eventually will be required at all RCRA sites. If vadose zone monitoring becomes an additional requirement under RCRA, both the facility owner and the taxpayer will benefit. During the interim, facility owners can benefit by employing vadose zone monitoring techniques coupled with either qualitative or quantitative chemical analyses.  相似文献   

11.
One of the greatest challenges in critical zone studies is to document the moisture dynamics, water flux,and solute chemistry of the unsaturated, fractured and weathered bedrock that lies between the soil and groundwater table. The central impediment to quantifying this component of the subsurface is the difficulty associated with direct observations. Here, we report solute chemistry as a function of depth collected over a full year across the shale-derived vadose zone of the Eel River Critical Zone Observatory using a set of novel sub-horizontal wellbores,referred to as the vadose zone monitoring system. The results of this first geochemical glimpse into the deep vadose zone indicate a dynamic temporal and depth-resolved structure. Major cation concentrations reflect seasonal changes in precipitation and water saturation, and normalized ratios span the full range of values reported for the world's largest rivers.  相似文献   

12.
Geochemical analysis of surface sediment samples collected in 2005 and 2006 was used to evaluate the potential sources of the organic matter present in sediments of southeast Poland's Solina Reservoir.Statistical analysis of sediment variables(carbon to nitrogen ratio, and the carbon 13 and nitrogen 15 isotope ratios) determined for the organic fraction indicated significant spatial variability with respect to sources of organic matter. A binary mixing model was developed from literature sources to predict the relative contributions of allochthonous and autochthonous production to sediment organic matter.Autochthonous production was shown to account for 60-75% of bulk sedimentation in the lacustrine parts of the reservoir, near the dam. In contrast, autochthonous production accounted for only 25% of sedimentation in the riverine zone receiving stream inputs. Statistical analysis identified the δ~(15)N of organic matter as the best predictor of the source of organic matter. Multiple regression analysis indicated that two water-quality variables(nitrate and dissolved silica) were significantly related to the δ~(15)N signature of organic matter. This led to a conclusion that limnetic nitrate and dissolved silica concentrations were regulating organic matter production in the Solina Reservoir.  相似文献   

13.
The effect of meteorological, landscape, geological-pedological, and hydrogeological factors on the formation of total water balance and infiltration recharge of groundwater. The results of analysis of calculated mean annual and within-year values of water balance elements on land surface and in the vadose zone were used to identify some regularities, governing the resulting input of moisture to groundwater table at different depth of its occurrence (infiltration).  相似文献   

14.
A combination of hydrometric data and observations of natural isotope (oxygen-18) variations in saturation overland flow and stream discharge were used to investigate the sources of storm run-off in a headwater swamp located in a permanent groundwater discharge zone near Toronto, Canada. The results of a two-component hydrograph separation indicated that pre-event water formed 80–90% of the stream hydrograph volume for six of the seven storms analyzed in June–November 1990. However, the instantaneous event water contribution showed considerable variability, ranging from maximum values of 20–25% for four moderate intensity storms to 63% for a high intensity thunderstorm with a return period of two years. The relative contribution of event and pre-event water to storm run-off from saturated areas and small streamlets within the swamp was similar to the main outlet stream. The dominance of pre-event water during storms could be accounted for by the mixing of a small volume of event water with a large pool of pre-event water on the surface of permanently saturated areas within the swamp. Occasional storms of high intensity or long duration produced a greater shift towards an event water signature in the saturated areas and a larger event water contribution to the outlet stream hydrograph.  相似文献   

15.
At complex sites there may be many potential sources of contaminants within the vadose zone. Screening‐level analyses are useful to identify which potential source areas should be the focus of detailed investigation and analysis. A source screening module (SSM) has been developed to support preliminary evaluation of the threat posed by vadose zone waste sites on groundwater quality. This tool implements analytical solutions to simulate contaminant transport through the unsaturated and saturated zones to predict time‐varying concentrations at potential groundwater receptors. The SSM integrates several transport processes in a single simulation that is implemented within a user‐friendly, Microsoft Excel? ‐ based interface.  相似文献   

16.
A relationship between indirect chemical indices of organic matter content of surface waters and light absorption in the visible and ultraviolet ranges is discussed. The allochthonous and autochthonous types of organic matter are found to essentially differ in the rate of light absorption. Techniques are proposed for the calculation of the concentrations of allochthonous and autochthonous organic matter by the integral rate of light consumption in the visible region and the bichromate oxidability of water, as well as by three indirect indices: chemical oxygen demand, permanganate oxidability, and water color index. The mean concentrations of allochthonous and autochthonous organic matter in large lakes (Ladoga, Onega, and Baikal) and in rivers and smaller water bodies in Karelia (>300 water objects) are analyzed. Allochthonous organic matter was found to predominate in most surface waters of Karelia (>80%), while allochthonous organic matter predominates only in lakes with a small specific catchment area (supposedly, <5) and in highly eutrophic lakes.  相似文献   

17.
Karst landscapes underlain with phosphatic limestones are now recognized to be an important contributor of fluvial phosphorus (P) to coastal waters. Specifically, karst agroecosystems may be a hotspot for dissolved reactive P (DRP) due to chronic over-application of organic and inorganic fertilizers that create legacy P accumulation in surface soils. Nevertheless, few studies have assessed the hydrologic controls on DRP transport in these systems at the watershed scale, which is the focus of this study. We analysed soil moisture, soil water extractable P, and storm event hydrologic and water quality data from a small heterogenous karst watershed (10.7 km2) in the Inner-Bluegrass Region of Central Kentucky, USA. Four storm events were sampled in winter, 2020 and were analysed for flow pathways using hydrograph recession analysis and water source connectivity using a tracer-based unmixing model. Based on hydrograph separation results, multiple linear regression analysis was performed to assess drivers of DRP concentrations and loadings. Soil water extractable P results showed stark vertical gradients with greater concentrations at both the surface and deeper soil zones, and minimum concentrations in the root zone. Results for the storm event analysis showed that water source connectivity provided superior prediction of DRP concentrations over the flow pathway analysis, which reflected the heterogeneity of karst maturity masking intermediate flow pathways. Findings from the MLR and loading analysis suggest waters sourced from the soil/epikarst produced significantly higher loadings compared with phreatic and precipitation water source in the three largest events, although concentrations fell between the phreatic (low) and precipitation (high) sources. Findings highlight variable activation of matrix-macropore exchange at different depths throughout the event. Collectively these results suggest existing models and approaches to assess karst hydrology need revision to improve management strategies in this critical landscape.  相似文献   

18.
Extensive nitrogen loads at the soil surface exceed plant uptake and soil biochemical capacity, and therefore lead to nitrogen accumulation in the deep vadose zone. Studies have shown that stored nitrogen in the vadose zone can eventually reach the water table and affect the quality of groundwater resources. Recently, global scale models have been implemented to quantify nitrate storage and nitrate travel time in the vadose zone. These global models are simplistic and relatively easy to implement and therefore facilitate analysis of the considered transport processes at a regional scale with no further requirements. However, the suitability of applying these models at a regional scale has not been tested. Here, we evaluate, for the first time, the performance and utility of global scale models at the regional scale. Applied to the Loess Plateau of China, we compare estimates of groundwater recharge and nitrate storage derived from global scale models with results from a regional scale approach utilizing the Richards and advection-dispersion equations. The estimated nitrate storage was compared to nitrate observations collected in the deep vadose zone (>50 m) at five sites across the Loess Plateau. Although both models predict similar spatial patterns of nitrate storage, the recharge fluxes were three times smaller and the nitrate storage was two times higher compared with the regional model. The results suggest that global scale models are a potentially useful screening tool, but require refinement for local scale applications.  相似文献   

19.
The organic carbon cycle of slowly permeable, clayey glacial till deposits in the Western Interior Great Plains, southern Alberta, was investigated by examining the relationship between solid organic matter (SOM) in the till sediments and dissolved organic carbon (DOC) in the till porewaters. Geochemically, the tills can be divided into two distinct zones: an upper oxidized (low SOM) till zone, and a lower unoxidized (high SOM) till zone. Till porewaters in both zones are characterized by high DOC contents. Radiocarbon dating and comparison of SOM and DOC fractions suggest DOC in the deep unoxidized zone originated during deglaciation, and is probably representative of groundwater ages in this till zone. In the oxidized zone, DOC originates from variable mixtures of soluble organic matter emplaced during deglaciation, and Cretaceous age coal fragments in this till zone. SOM in the upper till zone was mainly oxidized to CO2 gas during lowered water table conditions of the Altithermal climatic period. The subsurface production of fossil CO2 gas has serious implications for using the conventional dissolved inorganic carbon (DIC) 14C groundwater dating method in these clayey till porewaters.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号