1.
The seismic response of liquid-filled cylindrical storage tanks has been investigated using finite element techniques implemented in the general purpose structural analysis computer code ANSYS. Both added mass concepts and displacement-based fluid finite elements were employed to allow for the effects of the liquid. Simplified response spectrum modal analyses of a tank making use of the axisymmetric harmonic displacement patterns of the principal modes of deformation were found to give accurate predictions of the tank behaviour with a rigidly anchored base. Time history analyses of three-dimensional finite element models of unanchored and flexibly anchored tanks, with gap conditions between the tank base and the supporting floor to allow lift-off of the base, indicated that stresses in the tank and resultant loads on the floor can be much greater than for a rigidly restrained tank. These results demonstrate the importance of carefully considering the restraint conditions when performing seismic design calculations on storage tanks.  相似文献   

2.
A performance‐based earthquake engineering approach is developed for the seismic risk assessment of fixed‐roof atmospheric steel liquid storage tanks. The proposed method is based on a surrogate single‐mass model that consists of elastic beam‐column elements and nonlinear springs. Appropriate component and system‐level damage states are defined, following the identification of commonly observed modes of failure that may occur during an earthquake. Incremental dynamic analysis and simplified cloud are offered as potential approaches to derive the distribution of response parameters given the seismic intensity. A parametric investigation that engages the aforementioned analysis methods is conducted on 3 tanks of varying geometry, considering both anchored and unanchored support conditions. Special attention is paid to the elephant's foot buckling formation, by offering extensive information on its capacity and demand representation within the seismic risk assessment process. Seismic fragility curves are initially extracted for the component‐level damage states, to compare the effect of each analysis approach on the estimated performance. The subsequent generation of system‐level fragility curves reveals the issue of nonsequential damage states, whereby significant damage may abruptly appear without precursory lighter damage states.  相似文献   

3.
Scalar and vector intensity measures are developed for the efficient estimation of limit‐state capacities through incremental dynamic analysis (IDA) by exploiting the elastic spectral shape of individual records. IDA is a powerful analysis method that involves subjecting a structural model to several ground motion records, each scaled to multiple levels of intensity (measured by the intensity measure or IM), thus producing curves of structural response parameterized by the IM on top of which limit‐states can be defined and corresponding capacities can be calculated. When traditional IMs are used, such as the peak ground acceleration or the first‐mode spectral acceleration, the IM‐values of the capacities can display large record‐to‐record variability, forcing the use of many records to achieve reliable results. By using single optimal spectral values as well as vectors and scalar combinations of them on three multistorey buildings significant dispersion reductions are realized. Furthermore, IDA is extended to vector IMs, resulting in intricate fractile IDA surfaces. The results reveal the most influential spectral regions/periods for each limit‐state and building, illustrating the evolution of such periods as the seismic intensity and the structural response increase towards global collapse. The ordinates of the elastic spectrum and the spectral shape of each individual record are found to significantly influence the seismic performance and they are shown to provide promising candidates for highly efficient IMs. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
The non‐stationary rocking response of liquid storage tanks under seismic base excitations including soil interaction has been developed based on the wavelet domain random vibration theory. The ground motion has been characterized through statistical functionals of wavelet coefficients of the ground acceleration history. The tank–liquid–foundation system is modelled as a multi‐degree‐of‐freedom (MDOF) system with both lateral and rocking motions of vibration of the foundation. The impulsive and convective modes of vibration of the liquid in the tank have been considered. The wavelet domain coupled dynamic equations are formulated and then solved to get the expressions of instantaneous power spectral density function (PSDF) in terms of functionals of input wavelet coefficients. The moments of the instantaneous PSDF are used to obtain the stochastic responses of the tank in the form of coefficients of hydrodynamic pressure, base shear and overturning base moment for the largest expected peak responses. Parametric variations are carried out to study the effects of various governing parameters like height of liquid in the tank, height–radius ratio of the tank, ratio of total liquid mass to mass of foundation, and shear wave velocity in the soil medium, on the responses of the tank. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

5.
Buckling plays a fundamental role in the design of steel tanks because of the small thicknesses of the walls of this class of structures. The first part of the paper presents a review of this phenomenon for liquid‐containing circular cylindrical steel tanks that are fully anchored at the base, considering the different buckling modes and especially the secondary buckling occurring in the top part of the tank. A case study based on a cylindrical tank is then introduced in order to investigate various aspects of dynamic buckling. The finite element model of the case study tank is set‐up using the added mass method for fluid modelling. The influence of pre‐stress states caused by hydrostatic pressure and self‐weight on the natural periods of the structure is first studied and it is found that this influence is very small as far as the global behaviour of the tanks is considered, while it is important for local, shell‐type, vibration modes. In the following, the efficiency and sufficiency of different ground motion intensity measures is analysed by means of cloud analysis with a set of 40 recorded accelerograms. In particular, the peak ground displacement has been found being the most efficient and sufficient intensity measure so far as the maximum relative displacement of the tank walls is concerned. Finally, incremental nonlinear time‐history analyses are performed considering the case study structure under recorded earthquake ground motions in order to identify the critical buckling loads and to derive fragility curves for the buckling limit state. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
A wavelet‐based random vibration theory has been developed for the non‐stationary seismic response of liquid storage tanks including soil interaction. The ground motion process has been characterized via estimates of statistical functionals of wavelet coefficients obtained from a single time history of ground accelerations. The tank–liquid–soil system has been modelled as a two‐degree‐of‐freedom (2‐DOF) system. The wavelet domain equations have been formulated and the wavelet coefficients of the required response state are obtained by solving two linear simultaneous algebraic equations. The explicit expression for the instantaneous power spectral density function (PSDF) in terms of the functionals of the input wavelet coefficients has been obtained. The moments of this PSDF are used to estimate the expected pseudo‐spectral acceleration (PSA) response of the tank. Parametric variations are carried out to study the effects of tank height, foundation natural frequency, shear wave velocity of soil and ratio of the mass of tank (including liquid) to the mass of foundation on the PSA responses of tanks. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

7.
Liquid storage tanks are essential structures that are often located in residential and industrial areas; thus an assessment of their seismic performance is an important engineering issue. In this paper, the seismic response of unanchored steel liquid storage tanks is investigated using the endurance time (ET) dynamic analysis procedure and compared to responses obtained for anchored tanks under actual ground motions and intensifying ET records. In most cases, the results from ground motions are properly obtained with negligible differences using ET records. It is observed that uplifting of the tank base, which is closely related to the tank aspect ratio, has the greatest significance in the responses of the tank and can be predicted with reasonable accuracy by using currently available ET records.  相似文献   

8.
The ‘strength’ of an earthquake ground motion is often quantified by an Intensity Measure (IM), such as peak ground acceleration or spectral acceleration at a given period. This IM is used to predict the response of a structure. In this paper an intensity measure consisting of two parameters, spectral acceleration and epsilon, is considered. The IM is termed a vector‐valued IM, as opposed to the single parameter, or scalar, IMs that are traditionally used. Epsilon (defined as a measure of the difference between the spectral acceleration of a record and the mean of a ground motion prediction equation at the given period) is found to have significant ability to predict structural response. It is shown that epsilon is an indicator of spectral shape, explaining why it is related to structural response. By incorporating this vector‐valued IM with a vector‐valued ground motion hazard, we can predict the mean annual frequency of exceeding a given value of maximum interstory drift ratio, or other such response measure. It is shown that neglecting the effect of epsilon when computing this drift hazard curve leads to conservative estimates of the response of the structure. These observations should perhaps affect record selection in the future. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

9.
浮放储罐三维地震反应有限元分析   总被引:1,自引:0,他引:1  
针对立式储罐,考虑液固耦合效应、地基与储罐结构的相互作用,采用有限元分析方法,对储罐在三维地震荷载作用下动反应进行了数值分析。分析结果表明:储罐三维地震加速度反应较一维地震加速度反应增加、提离高度明显放大、储罐轴向应力增加、基底剪力与弯矩增大。  相似文献   

10.
液压阻尼系统控制浮放立式储罐提离失稳   总被引:1,自引:0,他引:1  
立式圆柱储罐在油田、石油化工等企业用途广泛,多用作存贮易燃、易爆介质,一旦遭遇震害,后果将十分严重。本文针对浮放立式储罐地震响应的提离失稳问题,采用液压阻尼系统(HDS)用以控制储罐的提离反应,建立了安装HDS储罐的力学分析模型并进行了数值计算,对安装HDS后储罐的提离反应进行了分析。仿真计算结果表明:HDS可以有效地减小提离应力,从而地震烈度可以降低1度进行储罐的提离设计。  相似文献   