首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this report, the capabilities of the adaptively shifted integration (ASI)‐Gauss code in the analysis of the seismic responses of framed structures are verified and validated by comparing the results with detailed numerical simulations performed by the parallel finite element analysis code, E‐Simulator, and with experimental results obtained by E‐Defense. The numerical results obtained by both codes showed good agreement with the experimental results obtained by E‐Defense. Furthermore, seismic waves with unnaturally large magnitudes are applied to a high‐rise building model to demonstrate the ability of the ASI‐Gauss code to analyze the collapse behaviors of building frames. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
The implementation of buckling‐restrained braces (BRBs) for new reinforced concrete frame (RCF) constructions is limited. This study investigates the seismic forces and stability in the BRBs and gussets of a 2‐story full‐scale RCF specimen by using Abaqus models and a newly proposed stability evaluation method. The hybrid and cyclic loading test results are accurately predicted by the Abaqus analyses. Existing methods for computing the gusset interface forces for steel buildings from both the brace and the frame actions are compared with the Abaqus results. The applicability of these methods for the BRB‐RCF design is critically evaluated. It is confirmed that the Parallel‐2 method is suitable for estimating the BRB force demand imposed on the corner gusset and the generalized uniform force method is good for the corner gusset at the base. In addition, existing stability evaluation methods for BRBs and gussets are applied to investigate the out‐of‐plane (OOP) buckling of the first‐story BRB observed at the end of tests. The proposed stability model incorporates the BRB restrainer's flexural effects and 4 rotational springs in assessing the BRB's buckling. This model confirms that the BRB and the gusset's OOP buckling limit states could be coupled and must be evaluated together. By incorporating the flexural effects of the steel casing and the infilled grout, the proposed model satisfactorily predicts the OOP buckling of the first‐story BRB and gussets. These research results can be used for the implementation of BRBs in new RC frame constructions.  相似文献   

3.
The seismic performance tests of a full‐scale five‐story passively controlled steel building were conducted on the E‐Defense shaking table in Japan in March 2009. Before the tests, a blind prediction contest was held to allow researchers and practitioners from all over the world to construct analytical models and predict the dynamic responses of the steel frame specimen equipped with buckling‐restrained braces (BRBs) or viscous dampers (VDs). This paper presents the details of two refined prediction models made and results obtained before the tests. When the proposed analytical modeling techniques are adopted as in the two refined prediction models, the overall prediction accuracy is about 90%. Sensitivity studies conducted after the tests are also presented in this paper. The effects of varying each modeling feature on the response simulation accuracy have been investigated. The analytical results suggest that considering concrete full‐composite actions for beam members could improve prediction accuracy by about 20% against using the simplified bare steel beam model. Adopting refined BRB stiffness computed from incorporating finite‐element gusset stiffness only improves the overall prediction accuracy by 0.9%. Considering the BRB dynamic loading test results for analytical BRB strength reduces the error by 1.9%. For the VD frame, incorporating the brace and VD stiffness could improve the overall prediction accuracy by about 15%. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
A full‐scale shake table test on a six‐story reinforced concrete wall frame structure was carried out at E‐Defense, the world's largest three‐dimensional earthquake simulation facility, in January 2006. Story collapse induced from shear failure of shear critical members (e.g., short columns and shear walls) was successfully produced in the test. Insights gained into the seismic behavior of a full‐scale specimen subjected to severe earthquake loads are presented in this paper. To reproduce the collapse process of the specimen and evaluate the ability of analytical tools to predict post‐peak behavior, numerical simulation was also conducted, modeling the seismic behavior of each member with different kinds of models, which differ primarily in their ability to simulate strength decay. Simulated results showed good agreement with the strength‐degrading features observed in post‐peak regions where shear failure of members and concentrated deformation occurred in the first story. The simulated results tended to underestimate observed values such as maximum base shear and maximum displacement. The effects of member model characteristics, torsional response, and earthquake load dimensions (i.e., three‐dimensional effects) on the collapse process of the specimen were also investigated through comprehensive dynamic analyses, which highlighted the following seismic characteristics of the full‐scale specimen: (i) a model that is incapable of simulating a specimen's strength deterioration is inadequate to simulate the post‐peak behavior of the specimen; (ii) the torsional response generated from uniaxial eccentricity in the longitudinal direction was more significant in the elastic range than in the inelastic range; and (iii) three‐dimensional earthquake loads (X–Y–Z axes) generated larger maximum displacement than any other loading cases such as two‐dimensional (X–Y or Y–Z axes) or one‐dimensional (Y axis only) excitation. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
A series of hybrid and cyclic loading tests were conducted on a three‐story single‐bay full‐scale buckling‐restrained braced frame (BRBF) at the Taiwan National Center for Research on Earthquake Engineering in 2010. Six buckling‐restrained braces (BRBs) including two thin BRBs and four end‐slotted BRBs, all using welded end connection details, were installed in the frame specimen. The BRBF was designed to sustain a design basis earthquake in Los Angeles. In the first hybrid test, the maximum inter‐story drift reached nearly 0.030 rad in the second story and one of the thin BRBs in the first story locally bulged and fractured subsequently before the test ended. After replacing the BRBs in the first story with a new pair, a second hybrid test with the same but reversed direction ground motion was applied. The maximum inter‐story drifts reached more than 0.030 rad and some cracks were found on the gusset welds in the second story. The frame responses were satisfactorily predicted by both OpenSees and PISA3D analytical models. The cyclic loading test with triangular lateral force distribution was conducted right after the second hybrid test. The maximum inter‐story drift reached 0.032, 0.031, and 0.008 rad for the first to the third story, respectively. This paper then presents the findings on the local bulging failure of the steel casing by using cyclic test results of two thin BRB specimens. It is found that the steel casing bulging resistance can be computed from an equivalent beam model constructed from the steel core plate width and restraining concrete thickness. This paper concludes with the recommendations on the seismic design of thin BRB steel casings against local bulging failure. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
To improve the efficiency of model fitting, parameter identification techniques have been actively investigated. Recently, the applications of parameter identification migrated from off‐line model fitting to on‐line model updating. The objective of this study is to develop a gradient‐based method for model updating to advance hybrid simulation also called hybrid test. A novel modification of the proposed method, which can reduce the number of design variables to improve the identification efficiency, is illustrated in detail. To investigate the model updating, simulated hybrid tests were conducted with a 5‐story steel frame equipped with buckling‐restrained braces (BRBs) utilized in the shaking table tests conducted in E‐Defense in Japan in 2009. The calibrated analytical model that was verified with the test results can serve as the reference model. In the simulated hybrid tests, the physical BRB substructure is numerically simulated by utilizing a truss element with the 2‐surface model identical to the part of the reference model. Such numerical verification allows simulation of measurement errors for investigation on the performance of the proposed method. Moreover, the feasibility of sharing the identified parameter values, which were obtained from the physical substructure responses, with the relevant numerical models is also verified with the artificial component responses derived from the physical experiments.  相似文献   

7.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents a design approach for seismic rehabilitation of frames having a beam‐collapse mechanism using a technique termed minimal‐disturbance seismic rehabilitation. This technique pursues enhancing the seismic performance of buildings with the intention of improving the continuity of business. It minimizes obstruction of the visual and physical space of building users and the use of heavy construction equipment and work requiring fire permit (welding/cutting). The developed design approach is simple to use. Yet it leads to designs that limit the beams' plastic rotations to allowable values, while minimizing the number of locations where devices are installed and the devise dimensions. Furthermore, the effectiveness of the design approach and the rehabilitation technique is numerically studied through retrofitting a four‐story steel moment‐resisting frame. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

9.
The design of a three‐story buckling‐restrained braced frame (BRBF) with a single‐diagonal sandwiched BRB and corner gusset was evaluated in cyclic tests of a one‐story, one‐bay BRBF subassembly and dynamic analyses of the frame subjected to earthquakes. The test focused on evaluating (1) the seismic performance of a sandwiched BRB installed in a frame, (2) the effects of free‐edge stiffeners and dual gusset configurations on the corner gusset behavior, (3) the frame and brace action forces in the corner gusset, and (4) the failure mode of the BRBF under the maximum considerable earthquake level. The subassembly frame performed well up to a drift of 2.5% with a maximum axial strain of 1.7% in the BRB. Without free‐edge stiffeners, the single corner gusset plate buckled at a significantly lower strength than that predicted by the specificationof American Institute of Steel Construction (2005). The buckling could be eliminated by using dual corner gusset plates similar in size to the single gusset plate. At low drifts, the frame action force on the corner gusset was of the same magnitude as the brace force. At high drifts, however, the frame action force significantly increased and caused weld fractures at column‐to‐gusset edges. Nonlinear time history analyses were performed on the three‐story BRBF to obtain seismic demands under both design and maximum considerable levels of earthquake loading. The analytical results confirmed that the BRB and corner gusset plate achieved peak drift under cyclic loading test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
The inelastic seismic torsional response of simple structures is examined by means of shear‐beam type models as well as with plastic hinge idealization of one‐story buildings. Using mean values of ductility factors, obtained for groups of ten earthquake motions, as the basic index of post‐elastic response, the following topics are examined with the shear‐beam type model: mass eccentric versus stiffness eccentric systems, effects of different types of motions and effects of double eccentricities. Subsequently, comparisons are made with results obtained using a more realistic, plastic hinge type model of single‐story reinforced concrete frame buildings designed according to a modern Code. The consequences of designing for different levels of accidental eccentricity are also examined for the aforementioned frame buildings. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
A two‐story buckling‐restrained brace (BRB) frame was tested under bidirectional in‐plane and out‐of‐plane loading to evaluate the BRB stability and gusset plate design. The test comprised pseudo‐dynamic loadings using the 1999 Chi‐Chi earthquake scaled to the 50%, 10%, and 2% probability of exceedance in 50 years and a cyclic regime of increasing amplitudes of up to 3.0% story drift ratio (SDR). The specimen had a unique configuration where the beams were connected to the columns through shear tabs welded to the column flanges and bolted to the beam webs. Stable hysteretic behavior with only minor cracking at the gusset‐to‐column welds was observed under the pseudo‐dynamic tests, with maximum in‐plane and out‐of‐plane SDRs of 2.24% and 1.47% respectively. Stable behavior continued into the cyclic test where fracture of the gusset‐to‐column welds occurred in the first cycle to simultaneous bidirectional SDR of 3.0%. The observed BRB stability is consistent with a methodology developed for BRB frames under simultaneous in‐plane and out‐of‐plane drifts. The specimen behavior was studied using a finite element model. It was shown that gusset plates are subjected to a combination of BRB force and frame action demands, with the latter increasing the gusset‐to‐beam and gusset‐to‐column interface demands by an average of 69% and 83% respectively. Consistent with the test results, failure at the gusset‐to‐column interfaces is computed when frame action demands are included, thus confirming that not considering frame action demands may results in unconservative gusset plate designs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
The collapse of a one‐bay, four‐story steel moment frame is simulated in this study by the proposed peer‐to‐peer (P2P) Internet online hybrid test system. The typical beam hinging mechanism, which is ensured by a strong‐column, weak‐beam design, is reproduced. The plastic hinges at the column bases are taken as the experimental portions, while the superstructure is analyzed numerically by a general‐purpose finite element program. The implicit plastic rotations of the two column bases are treated as boundary displacements. In order to account for the complex behavior of the column bases, the P2P system is modified to use the secant stiffness during iterations, and the physical specimens are designed such that the plastic hinge behavior can be obtained. For this study, the three substructures are distributed to different locations. A large ground motion is repeatedly imposed until the column bases lose their capacity to sustain the gravity load. As a result, significant deterioration is observed at both column bases. The proposed P2P system is thus demonstrated to be able to accommodate multiple‐tested substructures involving unstable behavior. The results suggest that the P2P Internet online hybrid test system provides a reliable means of studying structures up to collapse. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
This paper investigates the implications of designing for uniform hazard versus uniform risk for light‐frame wood residential construction subjected to earthquakes in the United States. Using simple structural models of one‐story residences with typical lateral force‐resisting systems (shear walls) found in buildings in western, eastern and central regions of the United States as illustrations, the seismic demands are determined using nonlinear dynamic time‐history analyses, whereas the collapse capacities are determined using incremental dynamic analyses. The probabilities of collapse, conditioned on the occurrence of the maximum considered earthquakes and design earthquakes stipulated in ASCE Standard 7‐05, and the collapse margins of these typical residential structures are compared for typical construction practices in different regions in the United States. The calculated collapse inter‐story drifts are compared with the limits stipulated in FEMA 356/ASCE Standard 41‐06 and observed in the recent experimental testing. The results of this study provide insights into residential building risk assessment and the relation between building seismic performance implied by the current earthquake‐resistant design and construction practices and performance levels in performance‐based engineering of light‐frame wood construction being considered by the SEI/ASCE committee on reliability‐based design of wood structures. Further code developments are necessary to achieve the goal of uniform risk in earthquake‐resistant residential construction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
The growing emphasis of considering the behavior of structures at extreme performance states, such as collapse, has necessitated the characterization of the effects of varying attributes of the structural model. One source of variability that has not previously been considered is variability in the mathematical model. This study investigated the effects of changing the geometric nonlinearity approach and damping model on a four‐story buckling restrained braced frame, a four‐story steel moment resisting frame, and an eight‐story steel moment resisting frame. The variations in behavior are quantified using the maximum interstory drift ratio as the performance metric and qualified by comparing the relative displaced shapes and component response histories at the collapse performance state. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
This paper is the second part of a two‐part paper presenting the cyclic tests of four two‐story narrow steel plate shear walls (SPSWs). The first paper introduces the analytical studies and the specimen designs. This paper describes the test results. Some design implications including the capacity design for the first story column and the width‐to‐thickness ratio check for the beam web are discussed based on key observations from the tests. Test results confirm that the simplified strip model can accurately predict the inelastic responses of the specimens. Test results also confirm that the proposed capacity design method is effective in ensuring the plastic hinge formation at the bottom end of the first story column for SPSW with or without restrainers. Test results also show that the horizontal restrainers are effective in reducing the member forces in the boundary beam and column elements. Comparing the test results of the typical SPSW with those of the restrained SPSW (R‐SPSW) specimens, it is found that the R‐SPSW possesses an improved cyclic performance and reduced material weight. Analytical results predict the compressed column moments at the onset of the column plastic hinge formation well. The analytical hysteretic energy distribution in the first story column agrees very well with the observed inelastic actions developed in the four specimens. The detailed frame response analyses and the test results confirm that the assumptions made in developing the proposed column capacity design method are reasonable. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
This paper describes an analytical investigation on a reinforced concrete lateral load resisting structural system comprising a pin‐supported (base‐rocking) shear wall coupled with a moment frame on 1 or both sides of the wall. Yielding dampers are used to provide supplemental energy dissipation through the relative displacements at the vertical connections between the wall and the frames. The study extends a previous linear‐elastic model for pin‐supported wall‐frame structures by including the effects of the dampers. A closed‐form solution of the lateral load behavior of the structure is derived by approximating the discrete wall‐frame‐damper interactions with distributed (ie, continuous) properties. The validity of the model is verified by comparing the closed‐form results with computational models using OpenSees program. Then, a parametric analysis is conducted to investigate the effects of the wall, frame, and damper stiffness on the behavior of the structure. It is found that the damper stiffness significantly affects the distribution of shear forces and bending moments over the wall height. Finally, the performance‐based plastic design approach extended to the wall‐frame‐damper system is proposed. Case studies are carried out to design 2 damped pin‐supported wall‐frame structures using the proposed approach. Nonlinear dynamic time‐history analyses are conducted to verify the effectiveness of this method. Results indicate that the designed structures can achieve the performance level with the story drift ratios less than target values, and weak‐story failure mechanism is not observed. The approach can be used in engineering applications.  相似文献   

17.
Many reinforced‐concrete frames collapse via a soft‐story mechanism during severe earthquakes. Such collapses are mainly attributed to concentrated deformation in a soft story. Deformation control is thus important in preventing collapse. The frame pin‐supported wall structure is a type of rocking structure that releases constraints at the bottom of the wall. Previous research has obtained good results for the deformation control of this type of structure. However, the interior forces and strength demands of the pin‐supported wall have not been systematically explored. In this paper, a distributed parameter model is developed to investigate the strength demand of the wall in a frame pin‐supported wall structure. In the model, the pin‐supported wall is simplified as a bending beam and the frame is simplified as a shear beam. The two beams are joined by distributed shear connectors, so that the shear force can be transferred at any location on the interface. The model can be solved using differential equations based on equilibrium and compatibility. The accuracy of the model is verified using SAP2000 (Computers and Structures Inc., Berkeley, CA, USA). Displacement distribution of the structure and distributions of the moment and shear force within the pin‐supported wall are obtained for two typical external force profiles. It is found that the pin‐supported wall can effectively reduce the drift concentration factor. Distributions of the displacement, moment, and shear force are closely correlated with the relative stiffness of the wall and frame. Finally, recommendations on the stiffness and strength of a pin‐supported wall are made. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Collapse resistance of high‐rise buildings has become a research focus because of the frequent occurrence of strong earthquakes and terrorist attacks in recent years. Research development has demonstrated that numerical simulation is becoming one of the most powerful tools for collapse analysis in addition to the conventional laboratory model tests and post‐earthquake investigations. In this paper, a finite element method based numerical model encompassing fiber‐beam element model, multilayer shell model, and elemental deactivation technique is proposed to predict the collapse process of high‐rise buildings subjected to extreme earthquake. The potential collapse processes are simulated for a simple 10‐story RC frame and two existing RC high‐rise buildings of 18‐story and 20‐story frame–core tube systems. The influences of different failure criteria used are discussed in some detail. The analysis results indicate that the proposed numerical model is capable of simulating the collapse process of existing high‐rise buildings by identifying potentially weak components of the structure that may induce collapse. The study outcome will be beneficial to aid further development of optimal design philosophy. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A series of pseudo‐dynamic tests (PDTs) of a full‐scale 3‐story 3‐bay buckling‐restrained braced frame (BRBF) using concrete‐filled tube columns was tested in the Taiwan National Center for Research on Earthquake Engineering using networked PDT techniques in October 2003. During the tests, real‐time experimental responses and video were webcasted to Internet viewers. The input ground motions adopted for the PDTs were chosen from the 1999 Chi‐Chi and the 1989 Loma Prieta earthquakes and scaled to represent three seismic hazard levels. This paper is in two parts, focusing on the investigations of the overall structure and the local members. This paper constitutes Part I and discusses the design, analytical investigations, and key experimental results of the specimen frame, such as the buckling of the brace‐to‐gusset joints. Part II of the paper, the companion paper, describes the gusset stiffening schemes and detailed experimental behavior of the BRBs and their connections. Experimental peak inter‐story drifts of 0.019 and 0.023 radians, prescribed for the design basis and the maximum credible earthquakes, respectively, are within the target design limits of 0.020 and 0.025 radians. These tests confirmed that the PISA3D and OpenSees nonlinear structural analysis computer programs can simulate the experimental peak shears and floor displacements well. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
A series of large‐scale dynamic tests was conducted on a passively controlled five‐story steel building on the E‐Defense shaking table facility in Japan to accumulate knowledge of realistic seismic behavior of passively controlled structures. The specimen was tested by repeatedly inserting and replacing each of four damper types, that is, the buckling restrained braces, viscous dampers, oil dampers, and viscoelastic dampers. Finally, the bare steel moment frame was tested after removing all dampers. A variety of excitations was applied to the specimen, including white noise, various levels of seismic motion, and shaker excitation. System identification was implemented to extract dynamic properties of the specimen from the recorded floor acceleration data. Damping characteristics of the specimen were identified. In addition, simplified estimations of the supplemental damping ratios provided by added dampers were presented to provide insight into understanding the damping characteristics of the specimen. It is shown that damping ratios for the specimen equipped with velocity‐dependent dampers decreased obviously with the increasing order of modes, exhibiting frequency dependency. Damping ratios for the specimen equipped with oil and viscoelastic dampers remained constant regardless of vibration amplitudes, whereas those for the specimen equipped with viscous dampers increased obviously with an increase in vibration amplitudes because of the viscosity nonlinearity of the dampers. In very small‐amplitude vibrations, viscous and oil dampers provided much lower supplemental damping than the standard, whereas viscoelastic dampers could be very efficient. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号