首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 381 毫秒
1.
Two approximate methods for decomposing complicated inelastic dynamic responses of wall buildings into simple modal responses are presented. Both methods are based on the equivalent linear concept, where a non‐linear structure is represented by a set of equivalent linear models. One linear model is used for representing only one vibration mode of the non‐linear structure, and its equivalent linear parameters are identified from the inelastic response time histories by using a numerical optimizer. Several theoretical relations essential for the modal decomposition are derived under the framework of complex modal analysis. Various numerical examinations have been carried out to check the validity of the proposed modal decomposition methods, and the results are quite satisfactory in all cases. Fluctuating bending moment and shear at any location along the wall height contributed by each individual vibration mode can be obtained. Modal contributions to shear and flexural strength demands, as well as the corresponding modal properties, under various seismic loading conditions can also be identified and examined in detail. Furthermore, the effects of higher vibration modes on seismic demands of wall buildings are investigated by using the modal decomposition methods. Several new insights into the complicated inelastic dynamics of multi‐story wall buildings are presented. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

2.
This paper rigorously assesses the efficiency of viscous dampers connecting two walls to result in “viscously coupled shear walls”. This assessment also holds for viscous dampers in wall structures as they are mounted on frames parallel to the walls leading to “wall-viscous frame” systems. A continuum approach is adopted to model the structure so as to enable non-dimensional formulation of the governing equations. Those equations reveal that, under the approximations considered, the system damping ratio (defined here by 0.5 sqrt(c^2/(m*EI))) is a convenient compact single parameter controlling the response reduction w.r.t. the response of the corresponding undamped system. In contrast to coupled shear walls, this controlling parameter does not depend on the height of the building; therefore, the viscously damped system is efficient for low-rise buildings as well. The continuum approach also allows a semi-analytical solution of the eigenproblem in the complex domain followed by a complex modal spectral analysis. Those solutions reveal the efficiency of the added damping in reducing not only the displacements, inter-story drifts, and wall moments but also the absolute accelerations, wall shear, total shear, and total overturning moments. The results of the analyses and the non-dimensional tables and graphs developed for important response parameters lead to a simple method that could easily be implemented in practice for the purpose of initial design. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
This paper presents an efficient procedure to determine the natural frequencies, modal damping ratios and mode shapes for torsionally coupled shear buildings using earthquake response records. It is shown that the responses recorded at the top and first floor levels are sufficient to identify the dominant modal properties of a multistoried torsionally coupled shear building with uniform mass and constant eccentricity even when the input excitation is not known. The procedure applies eigenrealization algorithm to generate the state‐space model of the structure using the cross‐correlations among the measured responses. The dynamic characteristics of the structure are determined from the state‐space realization matrices. Since the mode shapes are obtained only at the instrumented floor (top and first floors) levels, a new mode shape interpolation technique has been proposed to estimate the mode shape coefficients at the remaining floor levels. The application of the procedure has been demonstrated through a numerical experiment on an eight‐storied torsionally coupled shear building subjected to earthquake base excitation. The results show that the proposed parameter identification technique is capable of identifying dominant modal parameters and responses even with significant noise contamination of the response records. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
This paper examines higher mode effects in systems where the ductile mechanism for seismic design is the base moment‐rotation response. The modal properties of flexural and shear beams with uniform mass and elasticity and with a variable amount of base rotational restraint are derived. As the base fixity is released, the first mode becomes the rigid body rotation of the beam about the base, but the higher modes change much less, particularly for the shear beam model. Most response quantities that are of interest in the seismic design of typical mid‐rise buildings are controlled by the first two lateral modes, except at locations along the height where the second mode contributes little. However, the third and higher lateral modes are more significant for high‐rise buildings. Based on the theory of uniform cantilever shear beams, expressions are developed to avoid the need for a modal analysis to estimate the overturning moment, storey shear, and floor acceleration envelopes. Considering the measured response from the shake table testing of a large‐scale eight‐storey controlled rocking steel braced frame, the proposed expressions are shown to be of similar or better accuracy to a modified modal superposition technique, which combines the higher mode response from an elastic modal analysis with the response associated with achieving the maximum base overturning moment according to an inverted triangular load distribution. Because the proposed method uses only parameters that are available at the initial design stage, avoiding the analysis of a structural model, it is likely to be especially useful for preliminary design. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
With the aid of perturbation analysis of vibration frequencies and mode shapes it is shown that any lower vibration mode of a torsionally coupled building may be approximated as a linear combination of three vibration modes of the corresponding torsionally uncoupled system (a system with coincident centres of mass and resistance but all other properties are identical to the actual system): one translational mode along each of the two principal axes of resistance and one mode in torsional vibration. This result provides the motivation for a simpler—relative to the standard—procedure for analysing the response of torsionally coupled multistorey buildings to earthquake ground motion. To illustrate the application and accuracy of this procedure two numerical examples are presented.  相似文献   

6.
The finite strip procedure is used to predict the free vibration response of both planar and non-planar coupled shear wall assemblies. The solid walls are considered as vertical cantilever strips and a comparison is made between modelling the spandrel beams as discrete beams and as an equivalent continuum with orthotropic plate properties. It is shown that both approaches lead to essentially the same frequencies. The effects of vertical inertial forces and shear deflection are included, and structures considered may have properties that vary with height. The method presented appears to be more versatile than previously published techniques and numerical comparisons with existing methods indicate the predicted results to be accurate.  相似文献   

7.
基于连续体系模型与传递矩阵法的结合,提出了一种简化方法来计算多肢剪力墙的动力特性。整个结构体系等效模拟为一个夹层结构梁;建立了相应的基本微分方程;通过求解微分方程得到了楼层间变形函数;利用边界条件及层间变形函数导出了层间传递矩阵;据此计算出了体系的振型与自振频率。算例分析表明本文方法计算结果与文献给出的解是比较吻合的。  相似文献   

8.
Lateral load pattern in pushover analysis   总被引:9,自引:2,他引:7  
The seismic capacity curves of three types of buildings including frame, frame-shear wall and shear wall obtained by pushover analysis under different lateral load patterns are compared with those from nonlinear time history analysis. Based on the numerical results obtained a two-phase load pattern; an inverted triangle (first mode) load pattern until the base shear force reachesβ times its maximum value, Vmax, followed by a (x/H)α form, hereβ and α being some coefficients depending on the type of the structures considered, is proposed in the paper, which can provide excellent approximation of the seismic capacity curve for low-to-mid-rise shear type buildings. Furthermore, it is shown both the two-phase load pattern proposed and the invariant uniform pattern can be used for low-to-mid-rise shear-bending type and low-rise bending type of buildings. No suitable load patterns have been found for high-rise buildings.  相似文献   

9.
The paper presents a continuum method for dynamic analysis of asymmetric tall buildings with uniform cross-section in which the horizontal stiffness is provided by shear walls and columns of arbitrary shape and layout, coupled by horizontal beams. The equations of motions are formulated in variational terms, including axial strain energy. Numerical solutions, obtained by using finite time differences and infinite polynomials, are presented for the response of a twenty-storey building with six shear walls to an impact load and earthquake accelerations. It is shown that omission of the axial deformations results in a substantially distorted pattern of behaviour, some of its effects being:
  • 1 Overestimation of the bending stiffness of the coupled shear walls, with corresponding changes in their stiffness ratios.
  • 2 Underestimation of the periods of the principal modes, with a corresponding change in the dynamic response.
  • 3 Distortion of the magnitude, form, time of onset and coupling of the maximum displacements.
  • 4 Pronounced change in the shear force and moment diagrams for the shear walls, the beams and the building as a whole.
  相似文献   

10.
A summary of the development of a new coupled shear‐bending model for analysis of stacked wood shear walls and multi‐story wood‐frame buildings is presented in this paper. The model focuses on dynamic response of light‐frame wood structures under seismic excitation. The formulation is intended to provide a more versatile option than present pure shear models in that the new model is capable of accurately capturing the overall lateral response of each story diaphragm and separates the inter‐story shear deformation and the deformation associated with rotation of the diaphragm due to rod elongation, which is an analogue to the bending deformation in an Euler–Bernoulli beam model. Modeling the coupling of bending and shear deformation is shown to provide more accurate representation of stacked shear wall system behavior than a pure shear model, particularly for the upper stories in the assembly. The formulation is coupled with the newly developed evolutionary parameter hysteretic model for wood shear walls. Existing data from a shake table test of an isolated three‐story wood shear wall were used to verify the accuracy of the model prediction. The numerical results agreed very well with shake table test measurements. The influence of a continuous rod hold‐down system on the dynamic behavior of the three‐story stacked wood shear wall was also successfully simulated. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
A novel model for assessing building behavior has been developed by coupling a Bernoulli beam with a quartic stiffness variation and a shear beam with a parabolic stiffness variation, trends that are expected in buildings designed for earthquake actions. Then the partial differential equation of motion governing the behavior of the model has been solved, obtaining analytic expressions (Closed form solutions) for mode shapes in terms of Legendre functions. These closed form solutions were validated with finite element model analyses and effects of non-uniformity of stiffness were assessed in a generalized manner. It was found that period lengthening is mild for the first mode, but for higher modes can be far more noticeable if shear stiffness at beam top is <20 % of its base value. Mode shapes also change notoriously for reductions beyond the same limit, potentially inducing large floor acceleration demands at unexpected locations. Also it was found that drift demands can be noticeably enhanced even if shear stiffness at top is 75 % of the base value, in what would be considered uniform buildings. This model has several applications for assessing the response or large stocks of buildings, calibrate complex models, assess damage on building contents, establishing in short time damage scenarios for large cities, and could be helpful for education, as emphasis is brought back on fundamental concepts.  相似文献   

12.
Analysis and comparison of the dynamic responses of three well instrumented (with accelerographs) high-rise buildings shaken during the 1984 Morgan Hill earthquake are presented. The buildings examined in the present work are (i) the Town Park Towers Apartment building, a 10-storey, concrete shear wall building; (ii) the Great Western Savings and Loan building, a 10-storey building with concrete frames and shear walls; and (iii) the Santa Clara County Office building, a 13-storey, moment-resistant steel frame building. The structures are located within 2 km of each other and, as may be confirmed by visual inspection of the recorded seismograms, experienced similar ground motions. One-dimensional and three-dimensional linear structural models are fitted to the observations using the modal minimization method' for structural identification, in order to determine optimal estimates of the parameters of the dominant modes of the buildings. The time-varying character of these parameters over the duration of the response is also investigated. Comparison of the recorded earthquake response of the structures reveals that the type of lateral-load-resisting system has an important effect on the dynamic behaviour of the structures because it controls the spacing of the characteristic modes on the frequency axis. The Santa Clara County Office building has closely spaced natural frequencies and exhibits strong torsional response and modal coupling. Its dynamic behaviour is contrasted with that of the Great Western Savings and Loan building which has well separated natural frequencies and exhibits small torsional response and no modal coupling. Strong modal coupling causes a beating-type phenomenon and makes earthquake response of structures different from that envisioned by codes.  相似文献   

13.
A shear wall building is considered as an assembly of plane and curvilinear shear walls tied together by floor slabs to act as a composite unit. Based on this conception and the continuous medium approach, the governing dynamic equations and boundary conditions are derived from energy principles, using Vlasov's theory of thin-walled beams. All primary and secondary inertia forces, as well as the influence of elastic foundation flexibility, have been taken into consideration. A numerical solution of the dynamic equations is achieved by employing the Ritz-Galerkin technique, yielding both natural frequencies and mode shapes. The technique is applicable to buildings containing coupled and non-coupled, open section shear walls oriented in plan in any arbitrary manner. The use of the method is illustrated by the example of a complex building with unsymmetric plan, and the analytical natural frequencies of two shear wall building models are compared with those obtained experimentally by other investigators.  相似文献   

14.
Frame pin‐supported wall structure is a kind of rocking structure, which releases constraints at the bottom of the wall. The wall is affiliated to the frame and can rotate around the hinge. Previous studies have investigated seismic performance (such as deformation pattern and plastic hinge distribution) of frame pin‐supported wall structure. Strength demand of this system was investigated through static pushover analysis. However, dynamic characteristics, especially higher mode effects, remain to be quantified. As demonstrated in several researches, higher mode effects have non‐negligible effects on seismic response. For this purpose, a distributed model for analyzing higher mode effects in frame pin‐supported wall structure was proposed, where the pin‐supported wall and the frame were simplified as a bending beam and a shear beam, respectively. The model was solved by differential equations derived from equilibrium and compatibility. Displacement and inner force distribution of frame pin‐supported wall structure in higher modes were quantified according to the model. Influence of critical parameters, such as wall stiffness and structure period, was assessed on higher mode effects. It was demonstrated that response in higher modes cannot be neglected in the design of frame pin‐supported wall structure. Capacity design based on the fundamental mode is not conservative, especially in the wall. Furthermore, pin‐supported walls tend to force the frame to vibrate in the rocking mode and suppress higher mode effects in the frame. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
In this paper, a statistical study based on thirty-two strong rock motions is presented for the dynamic base shear of buildings on three different sites representing stiff soil, deep cohesionless soil and soft clay conditions. A short and squatty building and a tall and slender building are selected. For each building height, frame, wall and shearwall–frame systems are considered. It is found that short and squatty frame systems have the largest base shear. As for buildings on rock, the response of buildings on stiff and deep cohesionless soil conditions depends on the peak horizontal acceleration and peak horizontal velocity of the rock motion. Furthermore, the soil–structure interaction which affects only the stiff structures is found to reduce the dynamic base shear.  相似文献   

16.
The application of perturbation analysis in torsionally coupled buildings makes it possible to obtain an approximation of the dynamic properties of the buildings in question by combining appropriately the dynamic properties of the corresponding torsionally uncoupled buildings. This note aims to clarify the results obtained from a second-order perturbation analysis of the mode shapes of torsionally coupled buildings. Numerical examples of building models are given to illustrate the theoretical points.  相似文献   

17.
The dynamic properties of the twenty-two-story, steel-frame San Diego Gas and Electric Company Building in San Diego, California, have been determined experimentally in a series of co-operative tests between the California Institute of Technology and the University of California at Los Angeles. The building was vibrated by two eccentric mass exciters capable of frequencies up to 10 c/sec and forces as much as 5000 Ib each. The natural frequencies, associated mode shapes and the amounts of damping were determined for the first six modes of vibration in each of the two translational directions, and also in torsion. The mode shapes and frequencies showed, in general, the regularity and uniformity that appears typical of many tall buildings, but the three fundamental modes (nominally NS, EW and torsion) of the structure showed a coupling of translational and rotational components to a degree that was unexpected in a building whose structural frame is essentially symmetric. It is believed that this may be a consequence of the exceptionally small differences among the three fundamental frequencies. The damping in the first eighteen modes of the structure varied from 1.6 to 4.4 per cent, with a slight tendency for the larger values to be associated with the higher modes. Of the simpler damping models that might be used for analysis of the building, constant modal damping appears most appropriate and stiffness or mass proportional damping would not be realistic.  相似文献   

18.
The Galerkin method of weighted residuals is used to determine the frequencies and associated mode shapes of asymmetric shear wall-frame structures. The governing equations are formulated using the continuum approach by idealizing the structure as a shear-flexure beam. Varying properties along the height of the building are considered. The effect of translational, rocking and torsional flexibilities of the foundation on the natural frequencies is also investigated. The method presented herein utilizes polynomial and transcendental displacement functions, and is found to be simple, versatile and efficient.  相似文献   

19.
20.
An approximate method for linear analysis of asymmetric‐plan, multistorey buildings is specialized for a single‐storey, base‐isolated structure. To find the mode shapes of the torsionally coupled system, the Rayleigh–Ritz procedure is applied using the torsionally uncoupled modes as Ritz vectors. This approach reduces to analysis of two single‐storey systems, each with vibration properties and eccentricities (labelled ‘effective eccentricities’) similar to corresponding properties of the isolation system or the fixed‐base structure. With certain assumptions, the vibration properties of the coupled system can be expressed explicitly in terms of these single‐storey system properties. Three different methods are developed: the first is a direct application of the Rayleigh–Ritz procedure; the second and third use simplifications for the effective eccentricities, assuming a relatively stiff superstructure. The accuracy of these proposed methods and the rigid structure method in determining responses are assessed for a range of system parameters including eccentricity and structure flexibility. For a subset of systems with equal isolation and structural eccentricities, two of the methods are exact and the third is sufficiently accurate; all three are preferred to the rigid structure method. For systems with zero isolation eccentricity, however, all approximate methods considered are inconsistent and should be applied with caution, only to systems with small structural eccentricities or stiff structures. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号