首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Incremental dynamic analysis (IDA) is presented as a powerful tool to evaluate the variability in the seismic demand and capacity of non‐deterministic structural models, building upon existing methodologies of Monte Carlo simulation and approximate moment‐estimation. A nine‐story steel moment‐resisting frame is used as a testbed, employing parameterized moment‐rotation relationships with non‐deterministic quadrilinear backbones for the beam plastic‐hinges. The uncertain properties of the backbones include the yield moment, the post‐yield hardening ratio, the end‐of‐hardening rotation, the slope of the descending branch, the residual moment capacity and the ultimate rotation reached. IDA is employed to accurately assess the seismic performance of the model for any combination of the parameters by performing multiple nonlinear timehistory analyses for a suite of ground motion records. Sensitivity analyses on both the IDA and the static pushover level reveal the yield moment and the two rotational‐ductility parameters to be the most influential for the frame behavior. To propagate the parametric uncertainty to the actual seismic performance we employ (a) Monte Carlo simulation with latin hypercube sampling, (b) point‐estimate and (c) first‐order second‐moment techniques, thus offering competing methods that represent different compromises between speed and accuracy. The final results provide firm ground for challenging current assumptions in seismic guidelines on using a median‐parameter model to estimate the median seismic performance and employing the well‐known square‐root‐sum‐of‐squares rule to combine aleatory randomness and epistemic uncertainty. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
SPO2IDA is introduced, a software tool that is capable of recreating the seismic behaviour of oscillators with complex quadrilinear backbones. It provides a direct connection between the static pushover (SPO) curve and the results of incremental dynamic analysis (IDA), a computer‐intensive procedure that offers thorough demand and capacity prediction capability by using a series of nonlinear dynamic analyses under a suitably scaled suite of ground motion records. To achieve this, the seismic behaviour of numerous single‐degree‐of‐freedom (SDOF) systems is investigated through IDA. The oscillators have a wide range of periods and feature pinching hysteresis with backbones ranging from simple bilinear to complex quadrilinear with an elastic, a hardening and a negative‐stiffness segment plus a final residual plateau that terminates with a drop to zero strength. An efficient method is introduced to treat the backbone shape by summarizing the analysis results into the 16, 50 and 84% fractile IDA curves, reducing them to a few shape parameters and finding simpler backbones that reproduce the IDA curves of complex ones. Thus, vast economies are realized while important intuition is gained on the role of the backbone shape to the seismic performance. The final product is SPO2IDA, an accurate, spreadsheet‐level tool for performance‐based earthquake engineering that can rapidly estimate demands and limit‐state capacities, strength reduction R‐factors and inelastic displacement ratios for any SDOF system with such a quadrilinear SPO curve. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

3.
A new concept to determine state of the damage in concrete gravity dams is introduced. The Pine Flat concrete gravity dam has been selected for the purpose of the analysis and its structural capacity, assuming no sliding plane and rigid foundation, has been estimated using the two well‐known methods: nonlinear static pushover (SPO) and incremental dynamic analysis (IDA). With the use of these two methods, performance and various limit states of the dam have been determined, and three damage indexes have been proposed on the basis of the comparison of seismic demands and the dam's capacity. It is concluded that the SPO and IDA can be effectively used to develop indexes for seismic performance evaluation and damage assessment of concrete gravity dams. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Incremental dynamic analysis (IDA)—a procedure developed for accurate estimation of seismic demand and capacity of structures—requires non‐linear response history analysis of the structure for an ensemble of ground motions, each scaled to many intensity levels, selected to cover the entire range of structural response—all the way from elastic behaviour to global dynamic instability. Recognizing that IDA of practical structures is computationally extremely demanding, an approximate procedure based on the modal pushover analysis procedure is developed. Presented are the IDA curves and limit state capacities for the SAC‐Los Angeles 3‐, 9‐, and 20‐storey buildings computed by the exact and approximate procedures for an ensemble of 20 ground motions. These results demonstrate that the MPA‐based approximate procedure reduces the computational effort by a factor of 30 (for the 9‐storey building), at the same time providing results to a useful degree of accuracy over the entire range of responses—all the way from elastic behaviour to global dynamic instability—provided a proper hysteretic model is selected for modal SDF systems. The accuracy of the approximate procedure does not deteriorate for 9‐ and 20‐storey buildings, although their dynamics is more complex, involving several ‘modes’ of vibration. For all three buildings, the accuracy of the MPA‐based approximate procedure is also satisfactory for estimating the structural capacities for the limit states of immediate occupancy, collapse prevention, and global dynamic instability. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

5.
Uncertainties in structural engineering are often arising from the modeling assumptions and errors, or from variability in input loadings. A practical approach for dealing with them is to perform sensitivity and uncertainty analysis in the framework of stochastic and probabilistic methods. These analyses can be statically and dynamically performed through nonlinear static pushover and IDA techniques, respectively. Of the existing structures, concrete gravity dams are infrastructures which may encounter many uncertainties. In this research, probabilistic analysis of the seismic performance of gravity dams is presented. The main characteristics of the nonlinear tensile behavior of mass concrete, along with the intensity of earthquake excitations are considered as random variables in the probabilistic analysis. Using the tallest non‐overflow monolith of the Pine Flat gravity dam as a case study, its response under static and dynamic situations is reliably examined utilizing different combinations of parameters in the material and the seismic loading. The sensitivity analysis reveals the relative importance of each parameter independently. It will be shown that the undamaged modulus of elasticity and tensile strength of mass concrete have more significant roles on the seismic resistance of the dam than the ultimate inelastic tensile strain. In order to propagate the parametric uncertainty to the actual seismic performance of the dam, probabilistic simulation methods such as Monte Carlo simulation with Latin hypercube sampling, and approximate moment estimation techniques will be used. The final results illustrate the possibility of using a mean‐parameter dam model to estimate the mean seismic performance of the dam. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
应用弹塑性反应谱对IDA方法的改进研究   总被引:6,自引:1,他引:5  
针对传统IDA方法中结构的加速度反应远高于SPO分析结果的现象,采用弹塑性反应谱作为IDA的烈度度量,同时给出随地震烈度改变而不断变化的屈服强度系数,提出了改进的IDA方法,更有效地考虑了结构的非线性地震反应特征。实际工程分析表明,改进的IDA方法能够体现结构的非线性受力反应,同时兼顾结构的动力反应特征,与SPO曲线和由规范计算得到的结构承载力有更好的可比较性。  相似文献   

7.
A displacement-based design procedure is proposed for proportioning hysteretic damped braces in order to attain, for the in-plan least seismic capacity direction and a specific level of seismic intensity, a designated performance level of a reinforced concrete (r.c.) irregular framed building to be retrofitted. To this end, a computer code for the nonlinear static analysis of spatial frames is developed to obtain the pushover curve for an assigned in-plan direction of the seismic loads. The town hall of Spilinga (Italy), a two-storey r.c. framed structure with an L-shaped plan built at the beginning of the 1960s, has been considered as case study. Four alternative structural solutions are examined, derived from the first one by the insertion of hysteretic damped braces, considering: the extended N2 and the extended pushover methods combined with a proportional and an inversely proportional in-plan stiffness distributions of hysteretic damped braces. To check the effectiveness and reliability of the design procedure, the nonlinear static response of the unbraced and damped braced frames is compared for different in-plan directions of the seismic loads. Frame members are simulated with a lumped plasticity model, including a flat surface modeling of the axial load-biaxial bending moment elastic domain, while the behavior of a hysteretic damped brace is idealized through the use of a bilinear law. Vulnerability index domains are adopted to estimate the directions of least seismic capacity at the ultimate (i.e. life-safety and collapse prevention) limit states prescribed by Italian and European seismic codes.  相似文献   

8.
This paper develops a modal pushover analysis‐ (MPA) based approximate procedure to quantify the collapse potential of structural systems. The computationally demanding incremental dynamic analysis (IDA) of the structural system is avoided by MPA of the structure in conjunction with empirical equations for the collapse strength ratio for the first‐mode single‐degree‐of‐freedom (SDF) system; higher modes of vibration play essentially no role in estimating the ground motion intensity required to cause collapse of the structure. Presented are collapse fragility curves for 6‐, 9‐, and 20‐story regular special moment‐resisting teel frames computed by the exact and approximate procedures, demonstrating that the MPA‐based approximate procedure requires only a small fraction (1% in one example) of the computational effort inherent in exact IDA and still achieves highly accurate results. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
增量动力分析(IDA)作为动力形式的静力推覆法,被广泛应用于建筑结构的抗震能力分析和性能评估中,但其在土建筑遗址地震易损性分析中的应用甚少。基于IDA方法尝试对交河故城塔林区金刚宝座式塔土建筑遗址进行在地震作用下的易损性和抗震能力分析,以谱加速度SaT1,5%)作为地震动强度指标,最大层间位移角θmax作为结构损伤指标进行IDA分析,得到土建筑遗址在一系列调幅地震动作用下的IDA曲线、地震需求概率模型和易损性曲线,计算出模型的倒塌率和CMR值。通过以上分析得出金刚宝座式塔的易损性和抗震能力,为今后土建筑遗址抗震保护提供理论基础和分析思路。  相似文献   

10.
以小雁塔结构为原型,通过试验研究建立其材料本构模型;应用IDA分析方法,建立IDA分析曲线并对小雁塔结构进行增量动力弹塑性分析,判断小雁塔结构的最不利位置,定义IDA分析的极限状态;将IDA曲线的斜率下降幅值与小雁塔结构性能水准相对应,划分小雁塔结构的性能水准指标;通过对小雁塔结构在增量地震动强度作用下地震响应分析和不同性能状态下各层的楼层位移和层间位移角的变化规律,对小雁塔结构进行了抗震性能评估;研究表明:基于IDA分析方法的小雁塔抗震性能评估可以考虑结构抗震能力的随机因素,精确地描述小雁塔结构在地震过程中的行为。该方法为类似砖石古塔结构的抗震性能评估提供了新途径。  相似文献   

11.
An Erratum has been published for this article in Earthquake Engng. Struct. Dyn. 2004; 33:1429. Based on structural dynamics theory, the modal pushover analysis (MPA) procedure retains the conceptual simplicity of current procedures with invariant force distribution, now common in structural engineering practice. The MPA procedure for estimating seismic demands is extended to unsymmetric‐plan buildings. In the MPA procedure, the seismic demand due to individual terms in the modal expansion of the effective earthquake forces is determined by non‐linear static analysis using the inertia force distribution for each mode, which for unsymmetric buildings includes two lateral forces and torque at each floor level. These ‘modal’ demands due to the first few terms of the modal expansion are then combined by the CQC rule to obtain an estimate of the total seismic demand for inelastic systems. When applied to elastic systems, the MPA procedure is equivalent to standard response spectrum analysis (RSA). The MPA estimates of seismic demand for torsionally‐stiff and torsionally‐flexible unsymmetric systems are shown to be similarly accurate as they are for the symmetric building; however, the results deteriorate for a torsionally‐similarly‐stiff unsymmetric‐plan system and the ground motion considered because (a) elastic modes are strongly coupled, and (b) roof displacement is underestimated by the CQC modal combination rule (which would also limit accuracy of RSA for linearly elastic systems). Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
An envelope‐based pushover analysis procedure is presented that assumes that the seismic demand for each response parameter is controlled by a predominant system failure mode that may vary according to the ground motion. To be able to simulate the most important system failure modes, several pushover analyses need to be performed, as in a modal pushover analysis procedure, whereas the total seismic demand is determined by enveloping the results associated with each pushover analysis. The demand for the most common system failure mode resulting from the ‘first‐mode’ pushover analysis is obtained by response history analysis for the equivalent ‘modal‐based’ SDOF model, whereas demand for other failure modes is based on the ‘failure‐based’ SDOF models. This makes the envelope‐based pushover analysis procedure equivalent to the N2 method provided that it involves only ‘first‐mode’ pushover analysis and response history analysis of the corresponding ‘modal‐based’ SDOF model. It is shown that the accuracy of the approximate 16th, 50th and 84th percentile response expressed in terms of IDA curves does not decrease with the height of the building or with the intensity of ground motion. This is because the estimates of the roof displacement and the maximum storey drift due to individual ground motions were predicted with a sufficient degree of accuracy for almost all the ground motions from the analysed sets. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents the results of a multi‐level pseudo‐dynamic seismic test program that was performed to assess the performance of a full‐scale three‐bay, two‐storey steel–concrete composite moment‐resisting frame built with partially encased composite columns and partial‐strength beam‐to‐column joints. The system was designed to develop a ductile response in the joint components of beam‐to‐column joints including flexural yielding of beam end plates and shear yielding of the column web panel zone. The ground motion producing the damageability limit state interstorey drift caused minor damage while the ultimate limit state ground motion level entailed column web panel yielding, connection yielding and plastic hinging at the column base connections. The earthquake level chosen to approach the collapse limit state induced more damage and was accompanied by further column web panel yielding, connection yielding and inelastic phenomena at column base connections without local buckling. During the final quasi‐static cyclic test with stepwise increasing displacement–amplitudes up to an interstorey drift angle of 4.6%, the behaviour was ductile although cracking of beam‐to‐end‐plate welds was observed. Correlations with numerical simulations taking into account the inelastic cyclic response of beam‐to‐column and column base joints are also presented in the paper together. Inelastic static pushover and time history analysis procedures are used to estimate the structural behaviour and overstrength factors of the structural system under study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
基于单地震动记录IDA方法的结构倒塌分析   总被引:5,自引:2,他引:3  
增量动力分析(Incremental Dynamic Analysis, IDA)作为静力Pushover分析的动力拓展,可以全面、准确地分析结构的性能变化,尤其可以很好地分析结构倒塌这一动力失稳问题.本文基于单地震动记录的IDA方法,提出了"折半取中"原则,以确定结构倒塌极限状态点.以一榀五层三跨钢筋混凝土框架结构为例,分别考虑钢筋强化模型、理想弹塑性模型和软化模型,对其进行倒塌分析.结果表明:钢筋的屈服后强化特性对结构抗倒塌能力具有显著的影响.  相似文献   

15.
An analytical seismic fragility assessment framework is presented for the existing low strength reinforced concrete structures more common in the building stock of the developing countries.For realistic modelling of such substandard structures,low strength concrete stress-strain and bond-slip capacity models are included in calibrating material models.Key capacity parameters are generated stochastically to produce building population and cyclic pushover analysis is carried out to capture inelastic behaviour.Secant period values are evaluated corresponding to each displacement step on the capacity curves and used as seismic demand.A modified capacity demand diagram method is adopted for the degrading structures,which is further used to evaluate peak ground acceleration from back analysis considering each point on the capacity curve as performance point.For developing fragility curves,the mean values of peak ground acceleration are evaluated corresponding to each performance point on the series of capacity curves.A suitable probability distribution function is adopted for the secant period scatter at different mean peak ground acceleration values and probability of exceedance of limit states is evaluated.A suitable regression function is used for developing fragility curves and regression coefficients are proposed for different confidence levels.Fragility curves are presented for a low rise pre-seismic code reinforced concrete structure typical of developing countries.  相似文献   

16.
The opportunities provided by the use of fiber‐reinforced polymer (FRP) for the seismic retrofit of existing reinforced concrete (RC) structures were assessed on a full‐scale three‐story framed structure. The structure, designed only for gravity loads, was subjected to a bi‐directional pseudo‐dynamic (PsD) test at peak ground acceleration (PGA) equal to 0.20g at the ELSA Laboratory of the Joint Research Centre. The seismic deficiencies exhibited by the structure after the test were confirmed by post‐test assessment of structural seismic capacity performed by nonlinear static pushover analysis implemented on the lumped plasticity model of the structure. In order to allow the structure to withstand 0.30g PGA seismic actions, a retrofit using glass fiber‐reinforced polymer (GFRP) laminates was designed. The retrofit design was targeted to achieve a more ductile and energy dissipating global performance of the structure by increasing the ductility of columns and preventing brittle failure modes. Design assumptions and criteria along with nonlinear static pushover analysis to assess the overall capacity of the FRP‐retrofitted structure are presented and discussed. After the retrofit execution, a new series of PsD tests at both 0.20g and 0.30g PGA level were carried out. Theoretical predictions are compared with the main experimental outcomes to assess the effectiveness of the proposed retrofit technique and validate the adopted design procedures. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

17.
The performance‐based philosophy has been accepted as a more reasonable design concept for engineering structures. For this purpose, capacity evaluation and demand prediction procedures for civil engineering structures under earthquake excitations are of great significance. This work presents a displacement‐based seismic performance verification procedure including capacity and seismic demand predictions for steel arch bridges and investigates its applicability. Pushover analyses is employed as a basis in this method to investigate the structure's behaviors. A failure criterion for steel members accounting for the effect of local buckling is involved and an equivalent single‐degree‐of‐freedom (ESDOF) system with a simplified bilinear hysteretic model formulated using pushover analyses results is introduced to estimate the displacement capacity and maximum demand of steel arch bridges under major earthquakes. To check the accuracy of the proposed method, seismic capacities and demands from multi‐degree‐of‐freedom (MDOF) time‐history analyses with Level‐II design earthquake record inputs modeling major earthquakes are used as benchmarks for comparison. By a case study, it is clarified that the proposed prediction procedure can give accurate estimations of displacement capacities and demands of the steel arch bridge in the transverse direction, while insufficient for the longitudinal direction, which confirms the conclusion drawn in other structure types about the applicability of pushover analyses. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.

Evaluation of structural performance under seismic excitations from low intensity to high intensity is essential to verify the seismic resistant capacity of a structure, and usually carried out by the incremental dynamic analysis (IDA) method or pushover method. The recently developed endurance time (ET) method is another method that uses dynamic pushover excitations, i.e., endurance time acceleration function, to obtain results similar to those obtained by IDA or pushover methods with low computational cost and acceptable accuracy. This study proposes an improvement on the ET method by considering more restrictions for both the elastic and inelastic response spectra in the generation procedure, and by specifying a target duration. Four reinforced concrete frame structures with 4, 8, 12, and 16 stories are adopted to verify the accuracy of the improved method. Comparison of the results obtained by the proposed method, the ET method and the IDA method shows that the improved method has a higher accuracy than the ET method. For evaluation of structural responses under specific ground motion intensity, which is typically required in seismic design codes, the results obtained by the proposed method are compared with five commonly used ground motion selection methods, and shows the proposed method provides acceptable accuracy for engineering applications.

  相似文献   

19.
以某典型的12层钢筋混凝土框架结构作为研究对象,研究基于非线性动力时程分析和地震动参数的RC框架结构易损性分析方法。首先采用静力pushover分析判定结构薄弱层,并确定结构性能(capacity)参数;然后应用非线性动力时程分析估计结构地震反应,研究以峰值加速度和基本周期加速度反应谱作为地震动参数结构反应的不确定性,并进一步分析结构地震需求(demand)参数与地震动参数的关系;在此基础上,分别建立该结构基于峰值加速度和加速度反应谱的易损性曲线,通过考虑场地条件对地震动特性的影响,研究场地条件对结构易损性的影响,结果表明不同场地条件下的结构易损性曲线有一定差异。应用本文方法,根据新一代地震区划图或地震安全性评价确定的地震动参数,可以直接估计结构在未来地震中出现不同破坏的概率,这在结构的抗震性能评估和地震损失预测中有一定意义。  相似文献   

20.
The paper investigates the degree of accuracy achievable when some non‐linear static procedures based on a pushover analysis are used to evaluate the seismic performance. In order to assess the significance of different sources of errors, three types of structural systems are analysed: (i) single‐degree‐of‐freedom (SDOF) systems with different hysteretic behaviour; (ii) shear‐type multi‐degree‐of‐freedom (MDOF) systems with elastic–perfect plastic (EPP) shear force–interstorey drift relationships; (iii) a steel moment‐resisting frame with rigid joints and EPP moment–curvature relationship. In SDOF systems, the source of approximation comes only from the calibration of the demand spectrum, while in MDOF systems some further errors are introduced by the schematization with an equivalent SDOF system. The non‐linear static procedures are compared with rigorous time‐history analyses carried out by considering ten generated earthquake ground motions compatible with the Eurocode 8 elastic spectra. It was found that SDOF systems with longer periods satisfy the equal displacement approximation regardless of the hysteretic model, while hysteresis loops with smaller energy dissipated indicate lower response for shorter periods. This is the opposite of what predicted by the ATC‐40 capacity spectrum method, which underestimates and overestimates, respectively, the actual response of low‐ and high‐ductility systems. Conversely, the inelastic spectrum method proposed by Vidic, Fajfar and Fischinger leads to the most accurate results for all types of structural systems. The analyses carried out on EPP shear‐type frames point out a large concentration of the ductility demand on some storeys. However, such a concentration markedly reduces when some hardening is accounted for. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏