A procedure for displacement‐based seismic design (DBD) of reinforced concrete buildings is described and applied to a 4‐storey test structure. The essential elements of the design procedure are: (a) proportioning of members for gravity loads; (b) estimation of peak inelastic member deformation demands in the so‐designed structure due to the design (‘life‐safety’) earthquake; (c) revision of reinforcement and final detailing of members to meet these inelastic deformation demands; (d) capacity design of members and joints in shear. Additional but non‐essential steps between (a) and (b) are: (i) proportioning of members for the ULS against lateral loads, such as wind or a serviceability (‘immediate occupancy’) earthquake; and (ii) capacity design of columns in flexure at joints. Inelastic deformation demands in step (b) are estimated from an elastic analysis using secant‐to‐yield member stiffnesses. Empirical expressions for the deformation capacity of RC elements are used for the final proportioning of elements to meet the inelastic deformation demands. The procedure is applied to one side of a 4‐storey test structure that includes a coupled wall and a two‐bay frame. The other side is designed and detailed according to Eurocode 8. Major differences result in the reinforcement of the two sides, with significant savings on the DBD‐side. Pre‐test calculations show no major difference in the seismic performance of the two sides of the test structure. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

2.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Distributed plasticity beam elements are commonly used to evaluate limit state demands for performance‐based analysis of reinforced concrete (RC) structures. Strain limits are often preferred to drift limits because they directly relate to damage and are therefore less dependent on member geometry and boundary conditions. However, predicting accurately strain demands still represents a major simulation challenge. Tension shift effects, which induce a linear curvature profile in the plastic hinge region of RC columns and walls, are one of the main causes for the mismatch between experimental and numerical estimates of local level quantities obtained through force‐based formulations. Classical displacement‐based approaches are instead suitable to simulate such linear curvature profile. Unfortunately, they verify equilibrium only on an average sense due to the wrong assumption on the axial displacement field, leading to poor deformation and force predictions. This paper presents a displacement‐based element in which axial equilibrium is strictly verified along the element length. The assumed transversal displacement field ensures a linear curvature profile, connecting accurately global displacement and local strain demands. The proposed finite element is validated against two sets of quasi‐static cyclic tests on RC bridge piers and walls. The results show that curvature and strain profiles for increasing ductility demands are significantly improved when axially equilibrated rather than classical displacement‐based or force‐based elements are used to model the structural members. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

4.
The seismic design of multi‐story buildings asymmetric in plan yet regular in elevation and stiffened with ductile RC structural walls is addressed. A realistic modeling of the non‐linear ductile behavior of the RC walls is considered in combination with the characteristics of the dynamic torsional response of asymmetric buildings. Design criteria such as the determination of the system ductility, taking into account the location and ductility demand of the RC walls, the story‐drift demand at the softer (most displaced) edge of the building under the design earthquake, the allowable ductility (ultimate limit state) and the allowable story‐drift (performance goals) are discussed. The definition of an eccentricity of the earthquake‐equivalent lateral force is proposed and used to determine the effective displacement profile of the building yet not the strength distribution under the design earthquake. Furthermore, an appropriate procedure is proposed to calculate the fundamental frequency and the earthquake‐equivalent lateral force. A new deformation‐based seismic design method taking into account the characteristics of the dynamic torsional response, the ductility of the RC walls, the system ductility and the story‐drift at the softer (most displaced) edge of the building is presented and illustrated with an example of seismic design of a multi‐story asymmetric RC wall building. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
Two‐story, three‐bay reinforced concrete (RC) frames with and without internal steel frame (ISF) retrofits were tested using continuous pseudo dynamic test method. The ISFs were installed to the middle bay of the RC frame. Test results indicated that ISF retrofit was beneficial in resisting deformation demands without significant damage under simulated ground motions. The ISF shifted the failure mode of the system from a brittle to a ductile mode. The test results were compared with the results of the nonlinear time history analysis. The analysis results were capable of tracing the overall behavior of global response parameters; however, estimations of local demand parameters were less accurate. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
本文通过弹性和弹塑性时程分析,研究了水平地震作用下梁铰型屈服RC框架模型结构的楼层屈服剪力系数、基本自振周期、楼层数3个因素对弹塑性位移增大系数的影响,通过非线性回归分析给出了弹塑性层间位移增大系数经验公式;通过分析滞回耗能沿楼层高度的分布,初步确定了梁铰型屈服RC框架结构的薄弱楼层位置;基于结构损伤分析,讨论了抗震规范中RC框架结构弹塑性层间位移角限值的水准。  相似文献   

7.
Estimation of peak inelastic deformation demands is a key component of any displacement-based procedure for earthquake-resistant design of new structures or for seismic evaluation of existing structures. On the basis of the results of over a thousand non-linear dynamic analyses, rules are developed for the estimation of mean and upper-characteristic peak inelastic interstorey drifts and member chord rotations in multistorey RC frame buildings, either bare or infilled in all storeys but the first. For bare frame structures, mean inelastic deformation demands can be estimated from a linear, equivalent static, or preferably multimodal response spectrum analysis with 5 per cent damping and with the RC members considered with their secant stiffness at yielding. 95 per cent characteristic values can be estimated as multiples of the mean deformations. For open-first-storey buildings, the linear analysis can be equivalent static, with the infills modelled as rigid bidiagonal struts and all RC members considered with their secant stiffness to yielding. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

8.
Vibration control systems are being used increasingly worldwide to provide enhanced seismic protection for new and retrofitted buildings. This paper presents a new vibration control system on the basis of a seesaw mechanism with viscoelastic dampers. The proposed vibration control system comprises three parts: brace, seesaw member, and viscoelastic dampers. In this system, only tensile force appears in bracing members. Consequently, the brace buckling problem is negligible, which enables the use of steel rods for bracing members. By introducing pre‐tension in rods, long steel rods are applicable as bracing between the seesaw members and the moment frame connections over some stories. Seesaw mechanisms can magnify the damper deformation according to the damper system configuration. In this paper, first, the magnification factor, that is, the ratio of the damper deformation to the story drift, is delivered, which includes the rod deformation. Results of a case study demonstrate that the magnification factor of the proposed system is greater than unity for some cases. Seismic response analysis is conducted for steel moment frames with the proposed vibration control system. Energy dissipation characteristics are examined using the time‐history response results of energy. The maximum story drift angle distributions and time‐history response results of displacement show that the proposed system can reduce the seismic response of the frames effectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Hysteretic energy dissipation in a structure during an earthquake is the key factor, besides maximum displacement, related to the amount of damage in it. This energy demand can be accurately computed only through a nonlinear time‐history analysis of the structure subjected to a specific earthquake ground acceleration. However, for multi‐story structures, which are usually modeled as multi‐degree of freedom (MDOF) systems, this analysis becomes computation intensive and time consuming and is not suitable for adopting in seismic design guidelines. An alternative method of estimating hysteretic energy demand on MDOF systems is presented here. The proposed method uses multiple ‘generalized’ or ‘equivalent’ single degree of freedom (ESDOF) systems to estimate hysteretic energy demand on an MDOF system within the context of a ‘modal pushover analysis’. This is a modified version of a previous procedure using a single ESDOF system. Efficiency of the proposed procedure is tested by comparing energy demands based on this method with results from nonlinear dynamic analyses of MDOF systems, as well as estimates based on the previous method, for several ground motion scenarios. Three steel moment frame structures, of 3‐, 9‐, and 20‐story configurations, are selected for this comparison. Bias statistics that show the effectiveness of the proposed method are presented. In addition to being less demanding on the computation time and complexity, the proposed method is also suitable for adopting in design guidelines, as it can use response spectra for hysteretic energy demand estimation. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.
Inter‐story drift displacement data can provide useful information for story damage assessment. The authors' research group has developed photonic‐based sensors for the direct measurement of inter‐story drift displacements. This paper proposes a scheme for evaluating the degree of damage in a building structure based on drift displacement sensing. The scheme requires only measured inter‐story drift displacements without any additional finite element analysis. A method for estimating yield drift deformation is proposed, and then, the degree of beam end damage is evaluated based on the plastic deformation ratios derived with the yield drift deformation values estimated by the proposed method. The validity and effectiveness of the presented scheme are demonstrated via experimental data from a large‐scale shaking table test of a one‐third‐scale model of an 18‐story steel building structure conducted at E‐Defense. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
This study presents a seismic fragility analysis of low‐rise masonry in‐filled (MI) reinforced concrete (RC) buildings using a proposed coefficient‐based spectral acceleration method. The coefficient‐based method, without requiring any complicated finite element analysis, is a simplified procedure for assessing the spectral acceleration demand (or capacity) of buildings subjected to earthquakes. This paper begins with a calibration of the proposed coefficient‐based method for low‐rise MI RC buildings using published experimental results obtained from shaking table tests. Spectral acceleration‐based fragility curves for low‐rise MI RC buildings under various inter‐story drift limits are then constructed using the calibrated coefficient‐based method. A comparison of the experimental and estimated results indicates that the simplified coefficient‐based method can provide good approximations of the spectral accelerations at peak loads of low‐rise MI RC buildings, if a proper set of drift‐related factors and initial fundamental periods of structures are used. Moreover, the fragility curves constructed using the coefficient‐based method can provide a satisfactory vulnerability evaluation for low‐rise MI RC buildings under a given performance level. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
A new isolation interface is proposed in this study to retrofit existing buildings with inadequate soft stories as well as new structures to be constructed with soft first story intended for architectural or functional purposes. The seismic interface is an assembly of bearings set in parallel on the top of the first story columns: the multiple‐slider bearings and rubber bearings. The multiple‐slider bearing is a simple sliding device consisting of one horizontal and two inclined plane sliding surfaces based on polytetrafluoroethylene and highly polished stainless steel interface at both ends set in series. A numerical example of a five‐story reinforced concrete shear frame with soft first story is considered and analyzed to demonstrate the efficiency of the proposed isolation system in reducing the ductility demand and damage in the structure while maintaining the superstructure above the bearings to behave nearly in the elastic range with controlled bearing displacement. Comparative study with the conventional system as well as various isolation systems such as rubber bearing interface and resilient sliding isolation is carried out. Moreover, an optimum design procedure for the multiple‐slider bearing is proposed through the trade‐off between the maximum bearing displacement and the first story ductility demand ratio. The results of extensive numerical analysis verify the effectiveness of the multiple‐slider bearing in minimizing the damage from earthquake and protecting the soft first story from excessively large ductility demand. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Collapse resistance of high‐rise buildings has become a research focus because of the frequent occurrence of strong earthquakes and terrorist attacks in recent years. Research development has demonstrated that numerical simulation is becoming one of the most powerful tools for collapse analysis in addition to the conventional laboratory model tests and post‐earthquake investigations. In this paper, a finite element method based numerical model encompassing fiber‐beam element model, multilayer shell model, and elemental deactivation technique is proposed to predict the collapse process of high‐rise buildings subjected to extreme earthquake. The potential collapse processes are simulated for a simple 10‐story RC frame and two existing RC high‐rise buildings of 18‐story and 20‐story frame–core tube systems. The influences of different failure criteria used are discussed in some detail. The analysis results indicate that the proposed numerical model is capable of simulating the collapse process of existing high‐rise buildings by identifying potentially weak components of the structure that may induce collapse. The study outcome will be beneficial to aid further development of optimal design philosophy. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Many reinforced‐concrete frames collapse via a soft‐story mechanism during severe earthquakes. Such collapses are mainly attributed to concentrated deformation in a soft story. Deformation control is thus important in preventing collapse. The frame pin‐supported wall structure is a type of rocking structure that releases constraints at the bottom of the wall. Previous research has obtained good results for the deformation control of this type of structure. However, the interior forces and strength demands of the pin‐supported wall have not been systematically explored. In this paper, a distributed parameter model is developed to investigate the strength demand of the wall in a frame pin‐supported wall structure. In the model, the pin‐supported wall is simplified as a bending beam and the frame is simplified as a shear beam. The two beams are joined by distributed shear connectors, so that the shear force can be transferred at any location on the interface. The model can be solved using differential equations based on equilibrium and compatibility. The accuracy of the model is verified using SAP2000 (Computers and Structures Inc., Berkeley, CA, USA). Displacement distribution of the structure and distributions of the moment and shear force within the pin‐supported wall are obtained for two typical external force profiles. It is found that the pin‐supported wall can effectively reduce the drift concentration factor. Distributions of the displacement, moment, and shear force are closely correlated with the relative stiffness of the wall and frame. Finally, recommendations on the stiffness and strength of a pin‐supported wall are made. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
This paper uses nonlinear truss models for the analysis of shear‐dominated reinforced concrete (RC) columns subjected to cyclic loading. A previously established method, aimed to the analysis of RC walls, is enhanced to allow simulations of column members. The concrete constitutive equations are modified to account for the contribution of the aggregate interlock to the shear resistance. Additionally, an equation is proposed to determine the inclination angle of the diagonal members in the truss models. The modeling approach is validated using the results of quasi‐static and dynamic tests on shear‐dominated RC columns. The combination of predictive capabilities and conceptual simplicity establishes truss‐based models as an attractive approach for the systematic analysis of shear‐dominated RC frame construction. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
弹塑性位移谱法的振动台模型试验验证   总被引:2,自引:0,他引:2  
弹塑性位移谱法求解结构在指定强度地面运动作用下的位移需求是一种简便合理的方法。本文将弹塑性位移谱法就具体地震波计算的楼层位移需求、层间位移角需求与一比例为1/10的12层钢筋混凝土模型框架振动台试验结果作了比较。设计的12层钢筋混凝土模型框架结构在振动台上经历了7种强度等级地震波的作用,输入峰值加速度依次为:0.090g、0.258g、0.388g、0.517g、0.646g、0.775g和0.904g。求出了弹塑性位移谱法计算的楼层位移和层问位移角需求与振动台试验结果的比值,研究了二者比值的均值及方差沿楼层的分布情况。结果表明:弹塑性位移谱法的计算结果与振动台得到的位移需求值吻合较好,在基于性能的抗震设计中具有较好的应用前景。  相似文献   

17.
An application of a pin‐supported wall‐frame system in retrofitting an eleven‐story steel reinforced concrete frame is introduced. The retrofit aims at enhancing integrity and avoiding weak story failure in an existing moment‐resisting frame. Seismic performance of the building before and after the retrofit is assessed through nonlinear dynamic analysis. The results show that the pin‐supported walls are effective in controlling the deformation pattern of the ductile frame and hence in avoiding weak story failure. With the well‐controlled deformation pattern, carefully arranged energy dissipating devices are able to concentrate energy dissipations so that damage to the rest of the structure can be significantly reduced. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
碳纤维布增强混凝土框架抗震性能的有限元分析   总被引:2,自引:1,他引:1  
利用碳纤维布(CFS)对一个9层钢筋混凝土框架的底层柱进行了加固,运用有限元程序对加固前后结构的整体抗震性能进行了动力分析.分析结果表明,利用碳纤维布加固底部框架柱有助于提高框架的整体抗震性能,从而减少框架在地震作用下的最大侧移和各层间位移.  相似文献   

19.
For the purpose of estimating the earthquake response, particularly the story drift demand, of reinforced concrete (R/C) buildings with proportional hysteretic dampers, an equivalent single‐degree‐of‐freedom (SDOF) system model is proposed. Especially in the inelastic range, the hysteretic behavior of an R/C main frame strongly differs from that of hysteretic dampers due to strength and stiffness degradation in R/C members. Thus, the proposed model, unlike commonly used single‐spring SDOF system models, differentiates the restoring force characteristics of R/C main frame and hysteretic dampers to explicitly take into account the hysteretic behavior of dampers. To confirm the validity of the proposed model, earthquake responses of a series of frame models and their corresponding equivalent SDOF system models were compared. 5‐ and 10‐story frame models were studied as representative of low‐ and mid‐rise building structures, and different mechanical properties of dampers—yield strength and yield deformation—were included to observe their influence on the effectiveness of the proposed model. The results of the analyses demonstrated a good correspondence between estimated story drift demands using the proposed SDOF system model and those of frame models. Moreover, the proposed model: (i) led to better estimates than those given by a single‐spring SDOF system model, (ii) was capable of estimating the input energy demand and (iii) was capable of estimating the total hysteretic energy and the participation of dampers into the total hysteretic energy dissipation, in most cases. Results, therefore, suggest that the proposed model can be useful in structural design practice. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
This paper examined the statistical relationship between the curvature ductility demands of columns and the global displacement ductility demands of reinforced concrete (RC) frame structures when subjected to earthquakes. Elements with a designated moment–curvature relationship were adopted for both beam and column elements, and five-story and ten-story RC frame numerical structures were established. Using pushover analysis and earthquake nonlinear dynamic time-history analysis, the maximum global displacement ductility demands of the structure and the maximum curvature ductility demands of the columns were determined. The effects of the spectral acceleration and the strong column factor on ductility demands were analyzed, and the quantitative relationship between the curvature ductility demands of columns and the global displacement ductility demands of frame structures were established. Moreover, the validity of the established relationship was further tested and verified through a real-world application. The results show that the maximum curvature ductility demands of the columns and the maximum displacement ductility demands of the structure were positively associated with the spectral acceleration and negatively associated with the strong column factor. A proposed first-degree linear relationship between curvature ductility of columns and structural displacement ductility in RC frame structures with two parameters was obtained by curve fitting, while considering the effect of the strong column factor. The model was highly correlated with the sampling analysis data. Applying the empirical model established in this study is a simple and effective means to guide the design of ductility and the assessment of RC frame columns.  相似文献   