首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
The standardised growth curve (SGC) technique has the potential to save instrument time for equivalent dose (De) determination when applying single-aliquot regenerative-dose (SAR) protocol during optically stimulated luminescence (OSL) measurements. In this study, we test the applicability of two commonly used SGC procedures for OSL signals of quartz grains from aqueous deposits of the Yangtze Delta in China, which have been reported for weak luminescence signals and suffering from partial bleaching. Multiple silt-sized and sand-sized fractions of quartz samples from eight cores are used to construct SGCs by test dose standardisation (TD-SGC) and least-squares normalisation (LS-SGC), respectively. Three strategies, i.e. region-specific (SGCR), region with core-specific (SGCR + C) and core-specific (SGCC), are adopted to categorise these normalised data into different SGC datasets. The large variability of dose response signals is substantially reduced by the SGC procedures for most of these datasets. Hence, common SGCs for a variety of samples from the Yangtze Delta can be established, irrespective of their distinctive particle sizes and luminescence characteristics. The De values are then estimated using both TD-SGC and LS-SGC procedures for samples from a specific core. Comparing to the full SAR protocol, the TD-SGC procedure roughly gives reproducible De estimates lower than ∼100 Gy while the LS-SGC procedure derives generally consistent De estimates of up to ∼230 Gy. Although LS-SGCC and LS-SGCR + C procedures replicate the most consistent De values, the LS-SGCR procedure performs better in efficiency with a slightly less accuracy. In addition to careful comparison of LS-SGC and full SAR procedures, we suggest that a synchronous ratio derived by the chosen regenerative dose and its response signal for re-normalisation can be used to predict the LS-SGC De reliability on samples from similar sedimentary environments.  相似文献   

2.
《Quaternary Geochronology》2008,3(1-2):137-142
Standardized growth curves (SGCs) have recently been developed as a means to reduce measurement times when determining palaeodoses in the standardized luminescence (OSL) dating of quartz, but this approach is not without its critics. We test the performance of SGCs derived from samples from a range of environments in southern Africa and Florida (United States of America). Data presented here suggest that the method performed well when determining low (<50 Gy) equivalent dose (De) values from samples with different geological provenances within South Africa. However, the application of an SGC built from South African data performed poorly when used to estimate the palaeodoses of samples from Florida, with seven out of ten samples failing to replicate the single aliquot regenerative (SAR)-derived De value to within ±10%. We thus advocate the use only of regionally based SGCs for full De determination, although SGCs can also be utilized as a way of quickly generating SAR ‘range finders’ irrespective of sample origin. Furthermore, one sample from the Florida site did not show regenerative growth in accordance with any samples from either the South Africa or Florida data, resulting in significant De underestimation when using the SGC. Although the reasons for such behaviour are not yet understood, this re-iterates the recommendation of Burbidge et al. [2006. De determination for young samples using the standardised OSL response of coarse-grain quartz. Radiation Measurements 41(3), 278], to incorporate a single regenerative step in SGC protocols in order to check consistency.  相似文献   

3.
The establishment of standardised growth curve (SGC) for equivalent dose (De) determination can substantially reduce the amount of instrument time required for OSL measurements. In this study, we investigated the applicability of SGC for the optically stimulated luminescence (OSL) signal from single grains and small aliquots of sedimentary quartz from Haua Fteah cave, in Libya. The samples exhibit large inter-grain and inter-aliquot variation in the shape of their single grain and small aliquot dose response curves (DRCs) constructed from a range of sensitivity-corrected regenerative dose signals (Lx/Tx), which prevents the establishment of a single common SGC among different grains or small aliquots. Instead, the DRCs for the small aliquots can be divided into a minimum of three groups using the Finite Mixture Model, with the DRC saturating at a different dose level for each group. In order to establish a common DRC, or SGC, for each group, we propose a new normalisation method, the so-called least-squares normalisation procedure (‘LS-normalisation’), which largely reduces the variation between aliquots within the same group and allows the establishment of a common DRC, or SGC, for each group. In order to apply the SGC method for these samples, two regenerative dose points are needed for each aliquot to attribute it to one of the groups based on the ratio of the Lx/Tx signals for two sensitivity-corrected regenerative dose points. Equivalent dose (De) values for each aliquot can be estimated using the fitting parameters calculated for the SGC of the relevant group to which it belongs, together with measurements of the natural signal (Ln), one regenerative dose signal (Lx1) and their corresponding test dose signals (Tn, Tx1). For the samples investigated from Haua Fteah, we found that De estimates obtained from the SGCs are consistent with those obtained using a full SAR procedure. Our results suggest that small single-aliquot and single-grain De values obtained from application of the SGC may be underestimated if there is a significant proportion of early-saturating grains present in the sample; such grains or aliquots are mostly rejected due to saturation when analysed using the full SAR procedure. In this case, it is necessary to calculate the De values based only on those grains or aliquots that have relatively high saturation levels.  相似文献   

4.
Dating of quartz by optically stimulated luminescence (OSL) has been revolutionized with introduction of the test dose (TD) in development of a measurement sequence known as the single-aliquot regenerative-dose (SAR), whereby a valid sensitivity correction for the luminescence signal is provided in the measurement cycle. However, the size of the TD used in the SAR protocol remains controversial. Previous studies show that the TD has little effect on the equivalent dose (De) for young samples in luminescence dating in which the applicability of different deposits varies greatly in different regions. However, detailed studies are lacking on how TD size affects SAR–OSL results of samples with a relatively high De range. In this study, typical loess samples with high De values (∼60 Gy–∼250 Gy) from the eastern Tibetan Plateau were selected to investigate the effects of variation in TD size on the quartz SAR–OSL protocol. Dose recovery tests show that a known dose could be recovered successfully by applying different TDs. Test dose size has an effect on shapes of regenerated dose–response curves (DRCs) and has different influences on Des and characteristic saturation doses for quartz samples with a high dose range. A TD size of 20%–30% De is a good compromise for Tibetan loess with De of ∼60–120 Gy in the quartz SAR protocol, and a TD size larger than 30% should be considered for samples with a larger De. The results of this study highlight the importance of TD size in the SAR–OSL protocol for quartz samples with a high dose range.  相似文献   

5.
We simulated the variability in measured quartz optically stimulated luminescence (OSL) signals and dose response curves (DRCs) caused by measurement uncertainties, including counting statistics and instrumental irreproducibility. We find that these measurement errors can give rise to large variations in the observed luminescence signal and contribute to among-aliquot or among-grain scatter in DRCs and equivalent dose (De) values. Different measurement systems (i.e., luminescence readers) may have different counting statistics properties and, hence, may exhibit differing extents of variation in the observed OSL signal, even for the same sample. Our simulation shows that the random measurement uncertainties may result in some grains or aliquots being ‘saturated’ (that is, the measured natural signal is consistent with, or lies above, the saturation level of the measured DRC) and that the rejection of these ‘saturated’ grains may result in a truncated De distribution, with De underestimation for samples with natural doses close to saturation (e.g., twice the characteristic saturation dose, D0). We propose a new method to deal with this underestimation problem, in which standardised growth curves (SGCs) are established and the weighted-mean natural signal (Ln/Tn) from all measured grains is projected on to the corresponding SGCs to determine De. Our simulation results show that this method can produce reliable De estimates up to 5D0, which is far beyond the conventional limit of ∼2D0 using the standard SAR procedure.  相似文献   

6.
The standardised growth curve (SGC) for quartz OSL has recently been developed as a practical means to reduce measurement times when determining palaeodoses using quartz of aeolian sediments, especially loess and desert sand from the same section or the same geographical area. In the present study, we test the performance of SGCs for lacustrine sediments of three cores in the Qaidam Basin of the Qinghai-Tibetan Plateau (QTP) in China. A total of nine samples were collected (three samples from each of the three cores), and silt-sized (38–63 μm) quartz was extracted for the experiment. The results demonstrated that: (a) Nine samples display similar dose–response curves up to a regeneration dose of 600 Gy using single aliquot regenerative-dose (SAR) protocol, suggesting the existence of a standardised growth curve for lacustrine sediments in the Qaidam Basin; (b) For samples with Des of up to ~400 Gy, the Des determined by the SGC are in agreement with the Des by the SAR protocol, suggesting that the SGC approach could be used for De determination up to a dose of ~400 Gy for lacustrine samples from the Qaidam Basin of the Qinghai-Tibetan Plateau in China; (c) The saturation dose for these samples is more than 600 Gy, and in the growth curve a linear growth part was observed in the high dose range of >200 Gy.  相似文献   

7.
Raised beach sand deposits along the southeastern coast of Norway were dated by optical (OSL) and infrared stimulated luminescence (IRSL) and the quartz and K-feldspar luminescence characteristics were described. Due to the poor quartz luminescence characteristics, only a limited number of samples were suitable for OSL dating. More promising are the K-feldspar extracts, with typical K-feldspar luminescence characteristics and no sign of fading. For equivalent dose (De) determination, sand-size quartz and feldspar extracts were used, applying a single aliquot regenerative (SAR) protocol. Both, OSL and IRSL De estimates show a wide distribution, unexpected for beach deposits. The calculated OSL and IRSL age estimates were generally in good agreement and the correctness of the ages was confirmed by independent age control. Because only a limited number of the quartz samples were suitable for OSL dating, IRSL dating of the K-feldspar represents an alternative to OSL quartz dating.  相似文献   

8.
Chronostratigraphic records in the drylands of north China provide basic archives to reveal the dynamic connections between climate changes and the behaviour of aeolian systems. However, the interpretation of aeolian chronostratigraphy is not straightforward and may be associated with significant uncertainty due to a number of external and localised forces. Taking into account this complexity of aeolian systems, excluding preservation and sampling bias from palaeoclimatic signals requires that the interpretation of chronostratigraphic records be based on as many dates from as many sites as possible. Optically stimulated luminescence (OSL) dating provides a direct way to date aeolian sediments. However, the determination of equivalent dose (De) using the commonly applied single-aliquot regenerative dose (SAR) protocol is relatively time-consuming for samples with burial doses exceeding 50 or 100 Gy.In this study, the global standardised growth curve (gSGC) method is applied to multi-grain aliquots of coarse quartz from various sites covering a wide region of the south margin of the Tengger Desert in north China to rapidly determine De for a large number of aliquots and samples. The large between-aliquot variability in the shape of the dose response curve (DRC) is significantly reduced using a least-squares normalisation procedure. The results of a leave-one-out cross-validation (LOOCV) protocol demonstrates that De values determined using the gSGC and SAR methods are very consistent with each other up to at least 200 Gy and 400 Gy, for the 90–150 μm and 63–90 μm fractions, respectively. It suggests that the gSGC protocol can be used as an efficient procedure for De determination of a large number of aeolian samples from multiple sites. This in turn provides a better constraint for the interpretation of Late Quaternary aeolian chronostratigraphic records in drylands of north China.  相似文献   

9.
Portable optically stimulated luminescence (OSL) readers are robust devices that allow rapid determination of luminescence signals of polymineralic coarse-grained samples. To date, however, the utility of portable OSL readers has largely been confined to the construction of luminescence profiles that depict variations of luminescence signal intensities with depth. Because the luminescence signals used to construct such profiles are uncalibrated, it is neither practical to quantitatively compare portable OSL data from different sites nor is it possible to approximate sample ages. Such comparisons could be facilitated by converting portable OSL signals into equivalent doses (De). However, determining De requires the construction of unique growth curves for each sample; a laborious procedure that negates the rapidity associated with portable measurements. To circumvent that limitation, we construct standardised growth curves (SGCs) using normalized regeneration dose signals obtained using a portable OSL reader from the feldspar component of polymineralic sands from five disparate eolian dune sites in Alberta, Canada. Comparison of SGCs from different samples indicates general congruence and we merge these to construct a regionally applicable curve which we test by comparing the De obtained from given samples with that obtained using conventional OSL dating protocols. Results show that, though the uncertainties associated with the portable OSL data are high, the De values from the two approaches are linearly proportional. This direct variation enables portable OSL SGC De values to be used independently in reconnaissance studies that aim to screen samples for more detailed analysis using standard OSL methods. The affordability of portable OSL readers suggests that the approach could be attractive to researchers who do not have ready access to conventional OSL readers.  相似文献   

10.
We report investigations of the optically stimulated luminescence (OSL) signals of sedimentary quartz from different regions of Asia, Africa, Europe and North America using a single-aliquot regenerative-dose (SAR) procedure. We show that variations in the shape of dose response curves (DRCs), or growth curves, of the test dose sensitivity-corrected OSL signals among single aliquots composed of multiple grains can be greatly reduced by normalising the DRCs using one of the regenerative dose OSL signals. We refer to this regenerative-dose normalisation procedure as ‘re-normalisation’. We find a common re-normalised DRC extends to doses of ∼250 Gy for samples that differ significantly in terms of geological provenance, sedimentary context and depositional age. This feature permits the development of a ‘global standardised growth curve’ (gSGC) for OSL signals from single aliquots of quartz. The equivalent dose (De) of an aliquot can be estimated from the natural signal, one regenerative dose signal and their corresponding test dose signals. For the variety of samples investigated, we find that De estimates obtained from the gSGC are consistent with those obtained using full SAR procedures for doses of up to ∼250 Gy. Use of the gSGC for single aliquots would greatly reduce the time required to estimate the De values of older samples and for a large number of aliquots.  相似文献   

11.
A comparative study using quartz optically stimulated luminescence (OSL) and feldspar post-infrared infrared stimulated luminescence (post-IR IRSL) was undertaken on Quaternary fluvial sediments from an unnamed tributary of the Moopetsi River in South Africa. The aim is to assess whether the post-IR IRSL signal can be used to date incompletely bleached sediments. Several post-IR IRSL signals using varying stimulation and preheat temperatures were investigated; of these the post-IR IRSL225 signal was deemed most appropriate for dating because it bleached most rapidly. The feldspar post-IR IRSL225 equivalent dose (De) values from this site are consistently larger than those from quartz OSL, probably due to differences in the bleaching characteristics of the two signals. Additionally, the post-IR IRSL225 De values within a sample showed less variation in precision than the quartz De data, possibly due to greater averaging between grains in the feldspar small aliquots. The agreement between ages based on the OSL and post-IR IRSL225 signals was better for younger samples (<20 ka) than for older ones (>50 ka); the cause of this variation is unclear.  相似文献   

12.
The application of a regeneration procedure for optically stimulated luminescence (OSL) dating requires that the dose-response curve (DRC) of a natural sample is the same as that of a laboratory-generated one. However, the build-up of the laboratory-generated DRCs of quartz has been widely reported in the literature, i.e., the laboratory-generated DRCs are significantly higher than the natural counterparts in the high dose region (above 150 or 200 Gy). This results in severe underestimation of equivalent dose (De) for quartz OSL in the high dose region during the application of a single-aliquot regenerative-dose (SAR) protocol. However, the potential mechanism governing the build-up of the laboratory-generated DRC is still unclear. In this study, we performed a comprehensive investigation of the natural and laboratory-generated OSL signals and DRCs using a kinetic model for quartz. We compared the differences in charge concentrations between natural and laboratory-irradiated aliquots following irradiation and monitored the competition for holes and electrons during preheat and stimulation, for the natural, regenerative, and test dose cycles. In the course of the modelling, we could see the build-up of laboratory-generated DRCs, the underestimation of De, and a double exponential saturation characteristic of the DRCs. We demonstrated a discrepancy in competition for electrons in the deep electron trap and recombination centres during stimulation between the natural, regenerative, and test dose cycles. The simulation results are directly relevant to quartz OSL De determination using the SAR protocol and reveal the mechanisms responsible for the experimentally observed different behaviours between natural and laboratory-generated DRCs.  相似文献   

13.
Optically stimulated luminescence (OSL) dating methods have been widely applied in Quaternary glaciology. However, glacigenic deposits are considered in general as problematic for OSL dating, mainly because they are transported shorter distances prior to burial and are usually partially bleached. Thus, most researchers choose glaciofluvial and glaciolacustrine sediments (with relatively longer transportation times) for OSL dating when constraining the age of glaciation. In this study, four samples were collected from a lateral moraine series at Zhuqing Village, northern margin of Queer Shan Mountain, eastern Tibetan Plateau, in order to investigate the applicability of OSL dating for morainic deposits. Quartz grains (38–63 μm) were extracted and measured using single aliquot regenerative-dose (SAR) protocol. Internal checks and dose recovery test show that the SAR protocol is appropriate for equivalent dose (De) determination. The effect of thermal transfer is small for all samples and the recycling ratio for each individual sample is close to unity. The symmetry in the De distributions indicates that quartz grains were well-bleached prior to burial. OSL ages show good agreement with geomorphological and field investigations, and are also concordant with an independent ESR age. It is concluded that: (a) the morainic deposits in Zhuqing were well-bleached and suitable for OSL dating; (b) SAR protocol can be applied to morainic deposits for samples under study.  相似文献   

14.
Rapid sample preparation and measurement protocols for optically stimulated luminescence (OSL) dating have been investigated as a method of increasing the throughput of samples (e.g. Roberts et al. 2009). Here, we investigate the potential of dating samples treated using only hydrochloric acid (HCl) for providing accurate range-finder ages for quartz. The equivalent dose (De) is underestimated for older samples using a standard single-aliquot regenerative-dose (SAR) protocol, but measurement of the post-IR OSL signal (e.g. Roberts and Wintle, 2003) provides De estimates within 15% of the ‘target fully prepared De’ for two-thirds of samples. The application of a standardised growth curve (SGC) is also investigated. For these dune samples, the most efficient preparation and measurement procedure from which accurate De estimates can be obtained is treatment with HCl-only, measurement of the natural and regenerative post-IR OSL signal, and calculation using a region-independent SGC. A slightly longer protocol incorporating an additional preparation stage of heavy liquid density separation can be used to improve De estimates in samples where feldspar-contamination is thought to be particularly problematic. In practice, these time savings of days to weeks in the preparation and measurement protocols mean that a large number of samples can first be rapidly treated with HCl, the post-IR blue OSL signal measured using a shortened double-SAR protocol, and De calculated by applying an independent SGC before then deciding which samples require full preparation and measurement, rather than the inefficiency of committing time and resources to all samples if this is unnecessary for the context of a particular suite of samples. The potential of this rapid preparation and measurement protocol is discussed in relation to sand dune dating studies.  相似文献   

15.
Palynostratigraphical records have been used to understand the response of vegetation to climate change, and benefit from independent dating to ensure a robust correlation with global climate and sea-level change. In order to constrain the pollen chronology of a long sedimentary core taken at Azzano Decimo in the Friulian foreland of northeastern Italy, optically stimulated luminescence (OSL) has been applied to fine grain quartz. The samples meet all the standard performance criteria set to test the reliability of the single-aliquot regenerative-dose (SAR) protocol, and still show increasing dose response at 500 Gy. OSL ages are in good agreement with radiocarbon dating and the pollen interpretation down to 70 ka, and with De values of ~140 Gy, but below this point, they display an increasing age underestimation towards the Eemian and beyond. The comparison of De values measured using both a SAR and single-aliquot regeneration and added-dose (SARA) protocol, confirmed that both were successfully correcting for sensitivity changes in the quartz during measurement of the burial dose, and this was not the reason for the age underestimation. The quartz OSL dose response curve for all samples is best described by a saturating exponential plus linear (SEPL) function. Although all underestimated ages are derived from De values that fall on the high dose linear region of this curve, it is unclear if this is the cause of the underestimation.  相似文献   

16.
When measuring samples from southern Peru, we discovered an age offset between feldspar infrared-stimulated luminescence (IRSL) and quartz optically stimulated luminescence (OSL) ages. This age offset was not only found in these particular samples but was also observed in samples from a range of geographical localities. Extensive analysis revealed that it is actually the quartz age that underestimates the true depositional age, and this is due to a very weak fast component combined with other thermally unstable OSL signal components. We discuss properties of these poorly behaving samples and how to detect such samples prior to the OSL single-aliquot regenerative-dose (SAR) measurement. Finally, existing approaches to improve equivalent dose (De) determination are discussed for samples from southern Peru.  相似文献   

17.
In this study we test, for the first time, the potential of an elevated temperature post-IR IR (pIRIR290) SAR protocol for the dating of young heated artefacts. Seven heated stones and seven potshards were collected from three different archaeological sites in Denmark: one site from the early Pre-Roman Iron Age 200 BC to AD 100, and two from the Viking period between AD 800 and 1200.We first derive quartz OSL ages for these samples, to support the archaeological age control. The luminescence characteristics of the pIRIR290 signal are then investigated; in particular the dose recovery ratios are shown to be close to unity. The performance of the feldspar pIRIR290 protocol is then examined by comparing the pIRIR290 ages with those based on the quartz OSL signal; the average ratio of pIRIR290 to OSL ages is 1.14 ± 0.05 (n = 14) and there is some suggestion that the possible overestimation of the feldspar ages compared to quartz is only of significance for the heated stone samples. Nevertheless, there is no indication of incomplete heating of the stones; the ratios of De derived from the IR50 and pIRIR290 signals are independent of sample type, and consistent with complete resetting by heating. Comparison with the archaeological age control is not able to identify whether quartz or feldspar provides the most reliable dating signal.  相似文献   

18.
Modern Mississippi Delta sediments were analyzed to investigate quartz OSL signal resetting in large river deltas and test the accuracy of OSL dating on a decadal time scale with the early background subtraction and a recently proposed burial dose estimation procedure. Both fine silt-sized and sand-sized quartz were measured with a modified single-aliquot regenerative dose (SAR) protocol and equivalent dose (De) was calculated using different background subtraction methods. Evidence of insufficient bleaching was observed, but the residual signal is equivalent to ∼100 a on average for both sandy quartz and fine silt-sized quartz. It is shown that dose distributions of sandy quartz are affected by the background subtraction. The proportion of aliquots that have De in agreement with expectation is significantly larger when an early background is subtracted compared to the late background subtraction. This is, in contrast, not observed for fine silt-sized quartz. Accurate OSL ages were obtained by employing the unlogged minimum age model to Des of sandy quartz obtained with the early background subtraction method.  相似文献   

19.
Optically stimulated luminescence of fine silt quartz was investigated to establish chronologies for lake sediments from the British Isles. Feldspar contamination and its potential effects on equivalent dose (De) determination were examined. A new feldspar contamination test based on the thermal quenching of quartz OSL and thermal assistance of feldspar OSL identified feldspar contamination in samples being treated for 20 min in 20% hydrofluoric acid. Feldspar component monitoring based on the post-IR OSL/OSL ratio was not sufficiently sensitive to monitor a feldspar component, but is a good indicator whether a standard SAR procedure can be applied successfully, despite the presence of feldspar. Based on these results we used a modified SAR protocol including a 100 s IRSL stimulation at 50 °C before OSL readout. This protocol could overcome any malign effects of feldspar even for a feldspar bearing polymineral sub-sample.  相似文献   

20.
Loess and fluvial sand are important materials for dating river terraces and alluvial fans. This study focuses on the methodological aspects of dating loess and fluvial deposits from the northern flank of the Tian Shan range, China, using sand-sized quartz and potassium (K) feldspar. Luminescence characteristics of quartz and K-feldspar were studied for searching suitable dating procedures. Our results indicate that 1) most quartz aliquots were contaminated by feldspar, and were dated using a post-infrared optically stimulated luminescence (post-IR OSL) procedure. A Fast ratio acceptance threshold of 15 can be applied to select these aliquots with post-IR OSL signals dominated by quartz OSL; 2) the multi-elevated-temperature post-IR IR stimulated luminescence (MET-pIRIR) procedures are applicable for K-feldspar. A test dose of ∼30% of the natural dose is appropriate for dating of older (>10 ka) samples. An Age (T, t) plateau test can be used to evaluate the dating results; 3) for the loess samples, both quartz and K-feldspar were well bleached and are suitable for dating. Dating using K-feldspar is preferred for its higher efficiency; 4) for the fluvial sand samples, only the quartz grains were fully bleached. Single-aliquot dating of quartz gives reliable ages.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号