首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effect of extraordinary degradation of phenol organics on the SnO2‐Sb2O3/Ti electrode is investigated through experimental research and theoretical analysis. The phenol organics contained 4‐chloro‐phenol, 4‐bromo‐phenol, and 2‐iodo‐phenol. At a current density of 4 mA cm–2 and an electrolysis time of 12 h, the degradation efficiency of the phenols was over 98% with a relatively short degradation time, whereas the degradation time of the PbO2/Ti electrode surpassed 40 h while delivering 100% disposal efficiency. Therefore, the effectiveness of electrochemical (EC) oxidation by the SnO2‐Sb2O3/Ti was superior to that of the PbO2/Ti electrode. At the same time, the SnO2‐Sb2O3/Ti had higher oxygen generation potential and lower electron consumption than the other electrodes. This was mainly due to the effect of the middle Sb2O3 layer, which due to its high porosity and good catalytic effect, contributed to a better catalysis than the SnO2 part.  相似文献   

2.
In this work, the treatment of photographic processing wastewaters (PPW) by electro‐Fenton process has been investigated. The Influence of operating conditions on kinetics and efficiency of electro‐Fenton process has been evaluated using carbon felt cathode and platinium (Pt) or boron‐doped diamond (BDD) anode. The results of electro‐Fenton treatment of PPW have shown that nearly complete removal of total phenols was obtained for all combinations with pseudo‐first rate constants of 0.07, 0.012, and 0.018/min for carbon felt/Pt, carbon felt/BDD and Pt/BDD cathode/anode combinations, respectively. The combination of carbon felt cathode with BDD anode achieved the highest total organic carbon (TOC) removal of 90%, while it did not exeed 40% for carbon felt/Pt combination. Increasing current intensity and Fe2+ dose enhances the efficiency of electro‐Fenton process. However, increasing pH decreases TOC removal during the treatment of PPW by electro‐Fenton process. The highest efficiency of electro‐Fenton process using BDD anode can be explained by the contribution of direct and indirect oxidation routes in the degradation mechanism of organics including (i) oxidation via hydroxyl radicals generated from the catalytic decomposition of H2O2 and from water discharge on BDD anode, (ii) direct oxidation of certain organic compounds on BDD anode, and (iii) mediated oxidation with inorganic oxidants electrogenerated from anodic oxidation of supporting salts.  相似文献   

3.
Micropollutants cover a variety of compounds that mainly originate from the pharmaceutical and agricultural sectors. Even at trace concentrations, the discharge of micropollutants into water bodies pose a serious threat to the environment and human health. Their removal from wastewaters at treatment plants before their discharge into the environment has become one of the leading topics of research. Physical, chemical, and biological treatment methods have been listed in the literature for efficient removal of a variety of pollutants. In this study, seven micropollutants, namely 4‐tert‐octylphenol, atrazine, 2,4,6‐trichlorophenol, fluoxetine, estrone, penconazole, and di‐n‐octyl phthalate, are spiked into municipal simulated synthetic wastewater and treated by a laboratory‐scale electrooxidation (EO) system using oxidized titanium and graphite electrode as anode and cathode, respectively. Sensitive determination of the selected micropollutants by gas chromatography–mass spectrometry (GC‐MS) before and after treatment is performed after their pre‐concentration using an eco‐friendly switchable solvent liquid‐phase microextraction method (SSLPME). The pH value, applied current, and reaction period are optimized to enhance the removal efficiency of micropollutants. Results show that the highest removal efficiency of all micropollutants is obtained at pH 3, 20 min reaction period, and 3 A applied current. The operational costs are also investigated in this study.  相似文献   

4.
Bezafibrate (BZF), a widely used lipid regulator, is a potential threat to ecosystems and human health in water, and the recent research showed that advanced oxidation processes (AOPs) are much more effective for BZF degradation. In this study, we investigated the photochemical decomposition of BZF in surface water and effluent from waste water treatment plants (WWTP) by UV/H2O2 process. The results showed that the UV/H2O2 process was a promising method to remove BZF at low concentration, generally at µg L?1 level. When initial concentrations reach 100 µg L?1 in the deionized water, >99.8% of BZF could be removed in 16 min under UV intensity of 61.4 µm cm?2, at the H2O2 concentration of 0.1 mg L?1, and neutral pH condition. Moreover, BZF degradation was inhibited in this process when humic acid (HA) and inorganic solution anions were added to the deionized water solutions, including chloride, nitrate, bicarbonate, and sulfate, significantly. In the surface water and effluent of WWTP, however, the removal efficiency of BZF was lower than that in the deionized water because of the interference of complex constituents in the surface water and effluent. Some main intermediates at the m/z range of 100–400 were observed by high performance LC‐MS (HPLC/MS) and a simple pathway of BZF degradation by UV/H2O2 was proposed.  相似文献   

5.
A first preliminary interlaboratory trial was planned to prepare ISO/DIS 12010: Water quality – determination of short chain polychlorinated alkanes (SCCP) in water – method using GC/MS and electron capture negative ionisation (ECNI). The task was to determine the sum of short chain polychlorinated n‐alkanes with carbon chain lengths of C10–C13 and a chlorine content between 49 and 67% in water by GC‐ECNI‐MS and quantification by multiple linear regression described in ISO/DIS 12010 as the compulsory method. Distributed samples were obtained from a real water extract spiked with a target concentration of 0.4 µg/mL sum of SCCP, i.e. the environmental quality target level according to the Water Framework Directive. The interlaboratory trial included the calibration, a column chromatographic clean up, a concentration step and an integration of chromatographic unresolved humps as well as the quantification with multiple linear regression. Reproducibility standard deviations between 21.5 and 22.9% were achieved by 17 participating laboratories from four countries. The method outlined no significant difference of the results between the standard solution and a real water matrix extract. On the basis of this succeeded preliminary interlaboratory trial the final interlaboratory trial for validation of ISO 12010 was prepared in autumn 2010.  相似文献   

6.
In this study, bench‐scale experiments were conducted to examine the UV/H2O2 oxidation of 17α‐ethynyestradiol (EE2) in water in a batch operation mode. The EE2 degradation exhibited pseudo‐first‐order kinetics, and the removal was ascribed to the production of hydroxyl radicals (?OH) by the UV/H2O2 system. Typically, the EE2 oxidation rate increased with increasing UV intensity and H2O2 dose, and with deceasing initial EE2 levels and solution pH. At EE20 = 650 µg/L, UV intensity = 154 µW/cm2, H2O2 = 5 mg/L, and neutral pH, the UV/H2O2 treatment was able to remove 90% of the EE2 content within 30 min. Four anions commonly present in water were found to inhibit EE2 degradation to varying degrees: > > Cl? > . Our results demonstrate that the described UV/H2O2 process is an effective method to control EE2 pollution in water.  相似文献   

7.
A portable gas chromatograph‐mass spectrometer (GC/MS) was used to investigate sources of chlorinated volatile organic compound (cVOC) contamination in indoor air at 46 residences around Hill AFB, Utah, that were potentially affected by vapor intrusion. Analytical methods were developed to allow sample turnaround times of less than 10 min and method detection limits (MDLs) generally less than 1 μg/m3 for a selected list of cVOCs. Area‐by‐area sampling was used to identify the likely vapor source locations. In many cases, individual container/enclosure sampling and subsequent field emission rate measurements from isolated consumer products were used to determine if identified products were likely to be the primary source of vapors in the residence. The portable GC/MS was also used to characterize vapor intrusion in two residences. In one of these two residences, building pressure control was used to enhance vapor entry in order to facilitate the investigation resulting in confirmation of vapor intrusion and identification of a primary route of vapor entry. cVOCs were identified in 42 of the 46 homes investigated, subsurface vapor intrusion was identified in two homes, and two homes had inconclusive results.  相似文献   

8.
In this study, electrochemical experiments were performed in non‐aqueous media in order to determine electrochemical behavior of some of the glyoxime derivatives (GDs). Phenylglyoxime (PG), p‐chloro‐phenylglyoxime (p‐CPG), and 1,2‐phenylendiamino‐p‐chlorophenylglyoxime (PACPG) were chosen as GDs. Pt wire, Ag/Ag+ (in 0.01 M AgNO3) and glassy carbon (GC) electrode were used as counter, reference, and working electrode, respectively. The multiscan cyclic voltammograms (CVs) of these compounds were registered in acetonitrile (MeCN) containing 0.1 M tetrabutylammonium tetrafluoroborat (TBATFB) at scan rate of 100 mV/s. The potential was swept from 0 to +2.0 V versus Ag/Ag+ (0.01 M). The CVs of GDs were compared with each other and the electrochemical behaviors of the compounds were investigated depending on the functional groups in their structures. The electrochemical characterization of these modified surfaces was performed and characterizations were compared with the chatacterization results of bare GC surfaces. The application areas for new surfaces were investigated. These results will be active in the disciplines of electrochemistry and industrial physical chemistry, and in related industrial fields at the dissemination of new information for scientific area.  相似文献   

9.
Four highly contaminated sediment samples obtained from three sampling locations of the Teltow Canal, Berlin, were investigated by quantitation of extractable and nonextractable organic contaminants. The selection of the anthropogenic contaminants (including chlorinated and brominated naphthalenes, 2, 4, 6‐tribromoaniline, phthalates, tri‐n‐butylphosphate, 2, 2, 4‐trimethyl‐1, 3‐pentanediol diisobutyrate, bisphenol A, butylated nitrophenols, 4‐nitrobenzoic acid, galaxolide, and tonalide) based on the results of extended GC‐MS screening analyses applied to the extracts of the sediment samples as well as to the extracts derived from selective chemical degradation procedures. In detail, alkaline hydrolyses, BBr3‐treatment and RuO4‐oxidation were applied to the pre‐extracted sediment samples in both a separate and a sequential mode.  相似文献   

10.
In this study the occurrence of diclofenac and sub‐products in effluent emerging from the University Hospital at the Federal University of Santa Maria was investigated. One metabolite was identified and, in aqueous solution, three degradation products. The quantification was conducted by means of HPLC‐DAD, and the determination of metabolite and degradation products by LC–ESI–MS/MS–QTrap. For the HPLC‐DAD method, a 70:30 mixture of methanol/sodium phosphate was used in isocratic mode. For the LC–ESI–MS/MS–QTrap determinations, a mobile phase, where phase A was an ammonium acetate solution 5 × 10?3 mol L?1, and phase B was methanol (5 × 10?3 mol L?1)/ammonium acetate (9:1, v/v), on gradient mode. The LDs for the HPLC and LC–MS/MS methods, respectively, were 2.5 and 0.02 µg L?1, the LQs, 8.3 and 0.05 µg L?1, and the linear range from 10 up to 2000 µg L?1 and 0.05 up to 10 µg L?1. As expected, the LC–ESI–MS/MS–QTrap method was more sensitive and less laborious. The metabolite 4′‐hydroxy‐diclofenac was identified. Photolysis was used for the degradation studies and three products of diclofenac were identified (m/z of 214, 286 and 303) in aqueous solution. These results notwithstanding, no degradation products of diclofenac were found in the hospital effluent.  相似文献   

11.
The decomposition of dichloroacetic acid (DCAA) in water using a UV/H2O2/micro‐aeration process was investigated in this paper. DCAA cannot be removed by UV radiation, H2O2 oxidation or micro‐aeration alone, while UV/H2O2/micro‐aeration combination processes have proved effective and can degrade this compound completely. With initial concentrations of about 110 μg/L, more than 95.1% of DCAA can be removed in 180 min under UV intensity of 1048.7 μW/cm2, H2O2 dosage of 30 mg/L and micro‐aeration flow rate of 2 L/min. However, more than 30 μg/L of DCAA was left after 180 min by UV/H2O2 combination process without micro‐aeration with the same UV intensity and H2O2 dosage. The effects of applied UV radiation intensity, H2O2 dose, initial DCAA concentration and pH on the degradation of DCAA have been examined in this study. Degradation mechanisms of DCAA with hydroxyl radical oxidation have been discussed. The removal rate of DCAA was sensitive to operational parameters. There was a linear relationship between rate constant k and UV intensity and initial H2O2 concentration, which indicated that a higher removal capacity can be achieved by improvement of both factors. A newly found nitrogenous disinfection by‐product (N‐DBP)‐DCAcAm, which has the potential to form DCAA, was easier to remove than DCAA by UV/H2O2 and UV/H2O2/micro‐aeration processes. Finally, a preliminary cost comparison revealed that the UV/H2O2/micro‐aeration process was more cost‐effective than the UV/H2O2 process in the removal of DCAA from drinking water.  相似文献   

12.
In this work, the treatment of actual agro‐industrial wastewaters (IWW) by a UV/H2O2 process has been investigated. The aqueous wastes were received from industrial olive oil mills and then treated by laboratory scale physicochemical methods, i. e., coagulation using ferrous and aluminum sulfate, decantation, filtration and adsorption on activated carbon. These wastes are brown colored effluents and have a residual chemical oxygen demand (COD) in the range of 1800 to 3500 mgO2 L–1, which cannot be further eliminated with physicochemical processes. The UV/H2O2 treatments were carried out under monochromatic irradiation at 254 nm using a thermostated reactor equipped with a mercury vapor lamp located in an axial position. The effects of initial H2O2 concentration, initial COD, pH and temperature have been studied in order to determine the optimum conditions for maximum color and COD removals. The experimental results reveal the suitability of the UV/H2O2 process for both removal of high levels of COD and effectively decolorizing the solution. In particular, 95% of color removal and 90% of COD removal were obtained under conditions of pH = 5 and 32°C using 2.75 g H2O2 g–1 COD L–1 during 6 h of UV‐irradiation. The treatment is unaffected by pH over the range 2 to 9. In addition, the COD removal is improved by increasing the temperature, whereas the color removal has not been affected by this parameter. The results show that the hydroxyl radicals generated from the catalytic decomposition of H2O2 by UV‐irradiation of the solution could be successfully used to mineralize the organics contained in IWW. The mineralization of the organics seems to occur in three main sequential steps: the first is the rapid decomposition of tannins leading to aromatic compounds, which are confirmed by the decolorization of the IWW; the second step corresponds to the oxidation of aromatics leading to aliphatic intermediates, which occurs by the cleavage of an aromatic ring, and is established by the removal of aromatics, and the final step is the slow oxidation of the aliphatic intermediates, which is measured by the COD removal.  相似文献   

13.
In the present study, the effects of initial COD (chemical oxygen demand), initial pH, Fe2+/H2O2 molar ratio and UV contact time on COD removal from medium density fiberboard (MDF) wastewater using photo‐assisted Fenton oxidation treatment were investigated. In order to optimize the removal efficiency, batch operations were carried out. The influence of the aforementioned parameters on COD removal efficiency was studied using response surface methodology (RSM). The optimal conditions for maximum COD removal efficiency from MDF wastewater under experimental conditions were obtained at initial COD of 4000 mg/L, Fe2+/H2O2 molar ratio of 0.11, initial solution pH of 6.5 and UV contact time of 70 min. The obtained results for maximum COD removal efficiency of 96% revealed that photo‐assisted Fenton oxidation is very effective for treating MDF wastewater.  相似文献   

14.
Remediation of the sites contaminated with organic contaminants, such as chlorobenzenes, remains a challenging issue. Electroosmotic flushing can be a promising approach which is based on mechanism of electrokinetic remediation for removal of organic contaminants from fluids in low‐permeability soil. To select an optimum surfactant that can effectively enhance electroosmotic flushing, three common surfactants, Triton X‐100 (EK2), Tween 80 (EK3), and a mixture of sodium dodecyl sulfate and Triton X‐100 (EK4) buffered with Na2HPO4/NaH2PO4 solution, were tested. The efficiency of each kind of surfactant was evaluated using a three‐dimensional box filled with a clayey soil spiked with 1,2,4‐trichlorobenzene, and compared with a test (EK1) without surfactant. The results demonstrated that the buffer solutions efficiently neutralized H+ and OH? produced by electrolysis. EK3 with Tween 80 added in the flushing solution reached the highest electroosmotic permeability of 10?4 cm2/v/s and achieved a notably high cumulative electroosmotic flow (EOF) of 5067 mL within 6 d, which was 6.3, 3.4, and 4.2 times higher than that in EK1, EK2, and EK4, respectively. There were 420 mL more cumulative EOF obtained after 50 h of electrical application in EK4 than in EK2. The introduction of nonreactive ions can increase the current, thereby benefiting the EOF. Both the higher pH caused by the buffer and the application of nonionic surfactants can make the zeta potential more negative, thereby increasing the EOF. Tween 80 can be recommended as the best flushing solution for removing organic contaminants from sites when electrokinetic remediation is applied.  相似文献   

15.
The UV/H2O2 is one of the popular techniques in the advanced oxidation processes (AOPs) and has been applied in the wastewater treatment during recent two decades. UV exposure on the H2O2 generate highly reactive hydroxyl radicals (OH?), which are used to degrade organic contaminants through oxidation processes in wastewater. This present study involves the estimation of hydroxyl radical rate constants of methyldiethanolamine (MDEA) mineralization at different temperatures by using UV/H2O2 in aqueous solution. Laboratory experiments have been conducted and the profile of MDEA mineralization has been established. The hydroxyl radical rate constants and the activation energy of mineralization process have been calculated. The estimated hydroxyl rate constants and the activation energy are in good agreement with those reported in the literature.  相似文献   

16.
In the present study, effects of operational parameters on the electrical energy consumption for photooxidative process (UV/H2O2) for the decolorization of C. I. Acid Red 88 (AR88) have been investigated. In a series of experiments, 20 mg L?1 of AR88 solution were irradiated in the presence of different concentrations of H2O2 (to find out optimum amount of H2O2) by UV light intensity of 30 W m?2 for certain irradiation times. The decolorization of the dye followed pseudo first‐order kinetics, and hence, the figure‐of‐merit electrical energy per order (EEO) is appropriate for estimating the electrical energy efficiency. The electrical energy consumption was determined during the variation of some parameters such as initial H2O2 concentration, initial dye concentration, UV light intensity, pH, and the gap size of solution. Results showed that electrical energy could be reduced by optimizing operational parameters.  相似文献   

17.
The removal of Alphazurine FG (AF) dye from water by an electrocoagulation process has been studied. The effect of some operational parameters, such as anode material, current density, initial dye concentration, pH of solution, conductivity, and inter‐electrode distance, on the removal efficiency was investigated. Iron and aluminum were used as anodes in the electrocoagulation cell. It was found that the efficiency of the iron anode was better than that of the aluminum anode for AF removal. The factors that affected the removal efficiency were the current density and the initial dye concentration. The removal efficiency increased from about 35% at 25 A m–2 to about 97% at 100 A m–2, during 4 min of electrocoagulation. The results exhibited pseudo‐first‐order kinetics for AF removal by electrocoagulation. In addition, a mathematical model was successfully established for predicting the removal efficiency. A comparison between the model results and experimental data gave a high correlation coefficient (R2 = 0.9925), which indicates that the model is able to predict the removal efficiency of AF.  相似文献   

18.
The relative ability of Coriolus versicolor to grow on coir fiber as a ligninocellulosic material was examined. Addition of yeast extract to the culture increased laccase activity, which was further enhanced to the level of 1976 U/L by addition of 1 mM copper sulfate. Laccase thus produced was used without further purification for the decolorization of various dye solutions. Decolorization efficiency was compared with the conventional environment friendly oxidation technique using hydrogen peroxide in the presence of UV radiations. Laccase showed good decolorization in most of the cases. Excellent results were achieved when the dye solution was treated successively with laccase and UV/H2O2 wherein more than 80% decolorization was achieved. This value is remarkably higher than that attained either by the enzyme or UV/H2O2 photolysis alone.  相似文献   

19.
This experimental research deals with using steel scrap as a heterogeneous catalyst. This catalyzes the oxidation reaction of real textile dye wastewater based on a modified solar photo‐Fenton oxidation process. Morphologic analysis and mapping of the elementary composition of the steel scrap have been carried out by scanning electron microscopy. The effects of concentration of H2O2, the pH of the solution and the catalyst loading on the degradation of textile dye wastewater are elucidated. Kinetic studies have been performed for the decolorization of wastewater under optimum conditions. It could be concluded that the steel scrap is a potential substitute for ferrous salts as a catalyst for the solar photo‐Fenton reaction.  相似文献   

20.
Catechol is one of the most abundant phenolic components of olive mill wastewaters. In this article, the mineralization of this compound in synthetic aqueous solutions by the Fenton and photo‐Fenton processes is studied. It has been found that for 1.44 mM catechol, the total organic carbon of solutions is reduced about 94.4% at best after 60 min of Fenton treatment at optimized conditions of pH 3.0, 0.2 mM Fe2+, 7.09 mM H2O2, and 25°C. A faster and overall mineralization is attained by applying photo‐Fenton with UVA irradiation. o‐Benzoquinone, 1,2,3‐trihydroxybenzene and 1,2,4‐trihydroxybenzene were identified by GC–MS as primary quinonic and polyhydroxylated derivatives. Small amounts of generated carboxylic acids like muconic, maleic, malonic, acetic, oxalic, and formic acids were detected by ion‐exclusion chromatography. The Fe(III) complexes of these acids persist in the medium under Fenton conditions, while their photolysis by UVA light and that of other by‐products account for by the faster degradation and total mineralization achieved in the photo‐Fenton process. A reaction sequence for catechol mineralization by Fenton and photo‐Fenton involving all intermediates detected is proposed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号