1.
A Double-Canyon Radiation Scheme for Multi-Layer Urban Canopy Models   总被引:1,自引:0,他引:1  
We develop a double-canyon radiation scheme (DCEP) for urban canopy models embedded in mesoscale numerical models based on the Building Effect Parametrization (BEP). The new scheme calculates the incoming and outgoing longwave and shortwave radiation for roof, wall and ground surfaces for an urban street canyon characterized by its street and building width, canyon length, and the building height distribution. The scheme introduces the radiative interaction of two neighbouring urban canyons allowing the full inclusion of roofs into the radiation exchange both inside the canyon and with the sky. In contrast to BEP, we also treat direct and diffuse shortwave radiation from the sky independently, thus allowing calculation of the effective parameters representing the urban diffuse and direct shortwave radiation budget inside the mesoscale model. Furthermore, we close the energy balance of incoming longwave and diffuse shortwave radiation from the sky, so that the new scheme is physically more consistent than the BEP scheme. Sensitivity tests show that these modifications are important for urban regions with a large variety of building heights. The evaluation against data from the Basel Urban Boundary Layer Experiment indicates a good performance of the DCEP when coupled with the regional weather and climate model COSMO-CLM.  相似文献   

2.
MM5模式中城市冠层参数化方案的设计及其数值试验   总被引:15,自引:5,他引:15  
文中在综合国外一些较先进的中尺度模式城市作用参数化方案的基础上 ,从城市下垫面结构对城市边界层大气作用的物理机制及实际应用两方面出发 ,对城市下垫面结构和人为活动等因素对边界层结构的影响及中尺度模式中城市化作用的合理体现等问题进行了较全面的考虑 ,改进和设计出能够较全面、细致地描述城市结构对大气边界层动力、热力结构的影响 ,且适合中尺度模式结构特点的城市冠层参数化方案 (UCP) ,并实现了其与MM5模式的耦合。进行了耦合后的UCP方案及采用原城市作用方案的MM5模式对BECAPEX试验期间北京地区气象条件多重嵌套细尺度进行了模拟试验 ,并与观测结果对比 ,结果表明 :相比于MM 5模式中原有表示城市作用的参数化方案来讲 ,设计的UCP方案在很大程度上提高了MM 5模式对城市边界层热力和动力结构的模拟能力。  相似文献   

3.
Flow characteristics in the lower part of theatmospheric boundary layer developing immediatelyabove building roofs have been studied by physicalmodelling under neutral stratification conditions. Thevertical profiles of velocity, turbulence intensityand Reynolds stress were measured in detail above amodel urban fetch consisting of parallel streetcanyons. Two different street densities and roofshapes were tested. It is found that the influence ofthe buildings on the oncoming wind remains confined towithin three overall building heights above ground.Furthermore, the effect on the wind at roof levelfrom the areal building density is relatively weak, butstrong from the roof shape. Thus, altering roof shapecan have a much more beneficial impact on urban airquality than increasing the spacing betweenbuildings. Moreover, these findings yield a novelmethodology for reliable prediction of urban airquality, by combining numerical mesoscale wind flowmodels with physical street canyon pollutiondispersion models.  相似文献   

4.
The heat generated in buildings and the manner in which this heat is exchanged with the ambient environment can play an important role in urban climate. Recent studies have shown that anthropogenic heat from air-conditioning facilities can increase the exterior ambient temperature and should be taken into account for a more complete urban heat island (UHI) mitigation study. For this purpose, the first part of the present work is focused on the coupling of a new building energy model (BEM) and an urban canopy parameterisation (UCP). The new scheme is implemented in a finite volume mesoscale model (MM) and tested in a two-dimensional (2D) configuration of a city over flat terrain. A sensitivity study is performed with respect to different parameters in order to test the simulation system and enhance the understanding of the possible impacts of the BEM on the exterior microclimate.  相似文献   

5.
An urban canopy model is developed for use in mesoscale meteorological and environmental modelling. The urban geometry is composed of simple homogeneous buildings characterized by the canyon aspect ratio (h/w) as well as the canyon vegetation characterized by the leaf aspect ratio (σ l ) and leaf area density profile. Five energy exchanging surfaces (roof, wall, road, leaf, soil) are considered in the model, and energy conservation relations are applied to each component. In addition, the temperature and specific humidity of canopy air are predicted without the assumption of thermal equilibrium. For radiative transfer within the canyon, multiple reflections for shortwave radiation and one reflection for longwave radiation are considered, while the shadowing and absorption of radiation due to the canyon vegetation are computed by using the transmissivity and the leaf area density profile function. The model is evaluated using field measurements in Vancouver, British Columbia and Marseille, France. Results show that the model quite well simulates the observations of surface temperatures, canopy air temperature and specific humidity, momentum flux, net radiation, and energy partitioning into turbulent fluxes and storage heat flux. Sensitivity tests show that the canyon vegetation has a large influence not only on surface temperatures but also on the partitioning of sensible and latent heat fluxes. In addition, the surface energy balance can be affected by soil moisture content and leaf area index as well as the fraction of vegetation. These results suggest that a proper parameterization of the canyon vegetation is prerequisite for urban modelling.  相似文献   

6.
The impact of diurnal variations of the heat fluxes from building and ground surfaces on the fluid flow and air temperature distribution in street canyons is numerically investigated using the PArallelized Large-eddy Simulation Model (PALM). Simulations are performed for a 3 by 5 array of buildings with canyon aspect ratio of one for two clear summer days that differ in atmospheric instability. A detailed building energy model with a three-dimensional raster-type geometry—Temperature of Urban Facets Indoor-Outdoor Building Energy Simulator (TUF-IOBES)—provides urban surface heat fluxes as thermal boundary conditions for PALM. In vertical cross-sections at the centre of the spanwise canyon the mechanical forcing and the horizontal streamwise thermal forcing at roof level outweigh the thermal forces from the heated surfaces inside the canyon in defining the general flow pattern throughout the day. This results in a dominant canyon vortex with a persistent speed, centered at a constant height. Compared to neutral simulations, non-uniform heating of the urban canyon surfaces significantly modifies the pressure field and turbulence statistics in street canyons. Strong horizontal pressure gradients were detected in streamwise and spanwise canyons throughout the day, and which motivate larger turbulent velocity fluctuations in the horizontal directions rather than in the vertical direction. Canyon-averaged turbulent kinetic energy in all non-neutral simulations exhibits a diurnal cycle following the insolation on the ground in both spanwise and streamwise canyons, and it is larger when the canopy bottom surface is paved with darker materials and the ground surface temperature is higher as a result. Compared to uniformly distributed thermal forcing on urban surfaces, the present analysis shows that realistic non-uniform thermal forcing can result in complex local airflow patterns, as evident, for example, from the location of the vortices in horizontal planes in the spanwise canyon. This study shows the importance of three-dimensional simulations with detailed thermal boundary conditions to explore the heat and mass transport in an urban area.  相似文献   

7.
A Physically-Based Scheme For The Urban Energy Budget In Atmospheric Models   总被引:28,自引:1,他引:27  
An urban surface scheme for atmospheric mesoscale models ispresented. A generalization of local canyon geometry isdefined instead of the usual bare soil formulation currently usedto represent cities in atmospheric models. This allows refinement ofthe radiative budgets as well as momentum, turbulent heat and ground fluxes.The scheme is aimed to be as general as possible, in order to representany city in the world, for any time or weather condition(heat island cooling by night, urban wake, water evaporation after rainfalland snow effects).Two main parts of the scheme are validated against published data.Firstly, it is shown that the evolution of the model-predictedfluxes during a night with calm winds is satisfactory, considering both the longwave budget and the surface temperatures. Secondly, the original shortwave scheme is tested off-line and compared to the effective albedoof a canyon scale model. These two validations show that the radiative energy input to the urban surface model is realistic.Sensitivity tests of the model are performed for one-yearsimulation periods, for both oceanic and continental climates. The scheme has the ability to retrieve, without ad hoc assumptions, the diurnal hysteresis between the turbulent heat flux and ground heat flux. It reproduces the damping of the daytime turbulent heat flux by the heat storage flux observed in city centres. The latent heat flux is negligible on average,but can be large when short time scales are considered (especially afterrainfall). It also suggests that in densely built areas, domesticheating can overwhelm the net radiation, and supply a continuous turbulentheat flux towards the atmosphere. This becomes very important inwinter for continental climates. Finally, a comparison with a vegetation scheme shows that the suburban environment can be represented with a bare soil formulation for large temporal or spatial averages (typical of globalclimatic studies), but that a surface scheme dedicated to the urban surface is necessary when smaller scales are considered: town meteorological forecasts, mesoscale or local studies.  相似文献   

8.
The longwave upward radiation was calculated for an urban canopy by using a Monte Carlo model. The effects of the urban geometry were examined in terms of the fractional roof area, the height of the buildings and the emissivity. The urban canopy consists of identically sized buildings and the ground surfaces. The model allows for the temperature differences between the buildings and the ground surface and for multiple reflections in the canyon.The Monte Carlo results show that neglect of the geometric effects causes significant errors in calculated upward radiation: calculations with area-weighting of the radiation emitted from flat homogeneous surfaces are not appropriate. The upward flux is a nonlinear function of the fractional roof area, which may be approximated by a function of the square or cube of the fractional roof area. Neglect of the reflections by non-black surfaces (emissivity<1) underestimates the upward flux by a few percent for a canopy of emissivity=0.9. Radiation effects due to multiple reflections in the canyon are parameterized by use of the view factor and the fractional roof area. The parameterization scheme yields accurate results.  相似文献   

9.
Accurate simulation of air quality at neighbourhood scales (on order of 1-km horizontal grid spacing) requires detailed meteorological fields inside the roughness sub-layer (RSL). Since the assumptions of the roughness approach, used by most of the mesoscale models, are unsatisfactory at this scale, a detailed urban and rural canopy parameterisation, called DA-SM2-U, is developed inside the Penn State/NCAR Mesoscale Model (MM5) to simulate the meteorological fields within and above the urban and rural canopies. DA-SM2-U uses the drag-force approach to represent the dynamic and turbulent effects of the buildings and vegetation, and a modified version of the soil model SM2-U, called SM2-U(3D), to represent the thermodynamic effects of the canopy elements. The turbulence length scale is also modified inside the canopies. SM2-U(3D) assesses the sensible and latent heat fluxes from rural and urban surfaces in each of the computational layers inside the canopies by considering the shadowing effect, the radiative trapping by the street canyons, and the storage heat flux by the artificial surfaces. DA-SM2-U is tested during one simulated day above the city of Philadelphia, U.S.A. It is shown that DA-SM2-U is capable of simulating the important features observed in the urban and rural RSL, as seen in the vertical profiles of the shear stress, turbulent kinetic energy budget components, eddy diffusivity, potential air temperature, and specific humidity. Within the canopies, DA-SM2-U simulates the decrease of the wind speed inside the dense canopies, the skirting of the flow around the canopy blocks, warmer air inside the vegetation canopy than above open areas during the night and conversely during the day, and constantly warmer air inside the urban canopy. The comparison with measurements shows that the surface air temperature above rural and urban areas is better simulated by DA-SM2-U than by the `standard version' of MM5.  相似文献   

10.
多层城市冠层模式的建立及数值试验研究   总被引:4,自引:1,他引:3  
王咏薇  蒋维楣 《气象学报》2009,67(6):1013-1024
为在城市气象数值模拟中更好地体现由城市发展引起的下垫面土地利用改变及人为活动对大气过程的影响,建立了基于建筑物三维分布的多层城市冠层模式,冠层内动力方程组考虑了建筑物冠层拖曳力的作用及雷诺应力的影响,通过引入建筑物宽度、间距以及垂直分布密度指数等建筑物形态特征参数,以更好地体现城市复杂地表对大气温度、湿度及动量方程的影响.同时,该模式分屋顶、4个侧壤及地面分别考虑辐射及能量平衡求解表面温度,计算各表面与大气的通量交换,并考虑辐射阴影效应、冠层内部各个面之间的可视因子、以及与冠层内建筑物密度指数、可视因子等相关的多重反射辐射导致的辐射截陷作用.模式的离线检验结果表明:(1)冠层模式计算风廓线与风洞实验测量数据吻合良好;(2)离线冠层模式能够模拟实际小区的风速、温度垂直廓线,并能够较好地体现小区内气温日变化.冠层模式与区域边界层模式耦合检验结果表明:(1)耦合模拟的近地面(2 m处)气温及地表温度的结果明显优于传统的水泥平板方案,尤其是在夜间,水泥平板方案与实测气温最大偏差4 K左右,耦合模拟方案为1-2 K;(2)耦合模拟方案考虑了建筑物对冠层之上的拖曳力影响以及建筑物形态结构对雷诺应力的影响,风速(10 m处)计算结果与观测值相差约在1 m/s,水泥平板方案偏差3 m/s左右.  相似文献   