首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The Gaussian model of plume dispersion is commonly used for pollutant concentration estimates. However, its major parameters, dispersion coefficients, barely account for terrain configuration and surface roughness. Large-scale roughness elements (e.g. buildings in urban areas) can substantially modify the ground features together with the pollutant transport in the atmospheric boundary layer over urban roughness (also known as the urban boundary layer, UBL). This study is thus conceived to investigate how urban roughness affects the flow structure and vertical dispersion coefficient in the UBL. Large-eddy simulation (LES) is carried out to examine the plume dispersion from a ground-level pollutant (area) source over idealized street canyons for cross flows in neutral stratification. A range of building-height-to-street-width (aspect) ratios, covering the regimes of skimming flow, wake interference, and isolated roughness, is employed to control the surface roughness. Apart from the widely used aerodynamic resistance or roughness function, the friction factor is another suitable parameter that measures the drag imposed by urban roughness quantitatively. Previous results from laboratory experiments and mathematical modelling also support the aforementioned approach for both two- and three-dimensional roughness elements. Comparing the UBL plume behaviour, the LES results show that the pollutant dispersion strongly depends on the friction factor. Empirical studies reveal that the vertical dispersion coefficient increases with increasing friction factor in the skimming flow regime (lower resistance) but is more uniform in the regimes of wake interference and isolated roughness (higher resistance). Hence, it is proposed that the friction factor and flow regimes could be adopted concurrently for pollutant concentration estimate in the UBL over urban street canyons of different roughness.  相似文献   

2.
Our study employed large-eddy simulation (LES) based on a one-equation subgrid-scale model to investigate the flow field and pollutant dispersion characteristics inside urban street canyons. Unstable thermal stratification was produced by heating the ground of the street canyon. Using the Boussinesq approximation, thermal buoyancy forces were taken into account in both the Navier–Stokes equations and the transport equation for subgrid-scale turbulent kinetic energy (TKE). The LESs were validated against experimental data obtained in wind-tunnel studies before the model was applied to study the detailed turbulence, temperature, and pollutant dispersion characteristics in the street canyon of aspect ratio 1. The effects of different Richardson numbers (Ri) were investigated. The ground heating significantly enhanced mean flow, turbulence, and pollutant flux inside the street canyon, but weakened the shear at the roof level. The mean flow was observed to be no longer isolated from the free stream and fresh air could be entrained into the street canyon at the roof-level leeward corner. Weighed against higher temperature, the ground heating facilitated pollutant removal from the street canyon.  相似文献   

3.
A large-eddy simulation (LES) model, using the one-equation subgrid-scale (SGS) parametrization, was developed to study the flow and pollutant transport in and above urban street canyons. Three identical two-dimensional (2D) street canyons of unity aspect ratio, each consisting of a ground-level area source of constant pollutant concentration, are evenly aligned in a cross-flow in the streamwise direction x. The flow falls into the skimming flow regime. A larger computational domain is adopted to accurately resolve the turbulence above roof level and its influence on the flow characteristics in the street canyons. The LES calculated statistics of wind and pollutant transports agree well with other field, laboratory and modelling results available in the literature. The maximum wind velocity standard deviations σ i in the streamwise (σ u ), spanwise (σ v ) and vertical (σ w ) directions are located near the roof-level windward corners. Moreover, a second σ w peak is found at z ≈ 1.5h (h is the building height) over the street canyons. Normalizing σ i by the local friction velocity u *, it is found that σ u /u * ≈ 1.8, σ v /u * ≈ 1.3 and σ w /u * ≈ 1.25 exhibiting rather uniform values in the urban roughness sublayer. Quadrant analysis of the vertical momentum flux u′′w′′ shows that, while the inward and outward interactions are small, the sweeps and ejections dominate the momentum transport over the street canyons. In the x direction, the two-point correlations of velocity R v,x and R w,x drop to zero at a separation larger than h but R u,x (= 0.2) persists even at a separation of half the domain size. Partitioning the convective transfer coefficient Ω T of pollutant into its removal and re-entry components, an increasing pollutant re-entrainment from 26.3 to 43.3% in the x direction is revealed, suggesting the impact of background pollutant on the air quality in street canyons.  相似文献   

4.
Wind-tunnel studies of dispersion processes of traffic exhaust in urban street canyons with tree planting were performed and tracer gas concentrations using electron capture detection (ECD) and flow fields using laser Doppler velocimetry (LDV) were measured. It was found that tree planting reduces the air exchange between street canyons and the ambience. In comparison to treeless street canyons, higher overall pollutant concentrations and lower flow velocities were measured. In particular, for perpendicular approaching wind, markedly higher concentrations at the leeward canyon wall and slightly lower concentrations at the windward canyon wall were observed. Furthermore, a new approach is suggested to model porous vegetative structures such as tree crowns for small-scale wind-tunnel applications. The approach is based on creating different model tree crown porosities by incorporating a certain amount of wadding material into a specified volume. A significant influence of the crown porosity on pollutant concentrations was found for high degrees of porosity, however, when it falls below a certain threshold, no further changes in pollutant concentrations were observed.  相似文献   

5.
The questions on how vortices are constructed and on the relationship between the flow patterns and concentration distributions in real street canyons are the most pressing questions in pollution control studies. In this paper, the very large eddy simulation (VLES) and large eddy simulation (LES) are applied to calculate the flow and pollutant concentration fields in an urban street canyon and a cross-road respectively. It is found that the flow separations are not only related to the canyon aspect ratios, but also with the flow velocities and wall temperatures. And the turbulent dispersions are so strongly affected by the flow fields that the pollutant concentration distributions can be distinguished from the different aspect ratios, flow velocities and wall temperatures.  相似文献   

6.
A validated large-eddy simulation model was employed to study the effect of the aspect ratio and ground heating on the flow and pollutant dispersion in urban street canyons. Three ground-heating intensities (neutral, weak and strong) were imposed in street canyons of aspect ratio 1, 2, and 0.5. The detailed patterns of flow, turbulence, temperature and pollutant transport were analyzed and compared. Significant changes of flow and scalar patterns were caused by ground heating in the street canyon of aspect ratio 2 and 0.5, while only the street canyon of aspect ratio 0.5 showed a change in flow regime (from wake interference flow to skimming flow). The street canyon of aspect ratio 1 does not show any significant change in the flow field. Ground heating generated strong mixing of heat and pollutant; the normalized temperature inside street canyons was approximately spatially uniform and somewhat insensitive to the aspect ratio and heating intensity. This study helps elucidate the combined effects of urban geometry and thermal stratification on the urban canyon flow and pollutant dispersion.  相似文献   

7.
A model for the calculation of the turbulence flow field and air pollutant concentrations in urban canyons is developed. A two-dimensional set of hydrodynamical equations and a threedimensional diffusion equation are solved numerically with a personal computer. Different boundary conditions were investigated. Three flow regimes were found: without vortex, with one vortex, and with two vortexes, within an urban canyon. The influence of building density and wind speed components along the street was also investigated.  相似文献   

8.
为研究机动车辆排出的污染物在大气中的扩散规律,在北京做了小风条件下的街谷示踪试验。当楼顶风速u接近或大于1米/秒时,街谷内可形成一稳定的原生涡;u<0.6米/秒时原生涡将消失。对于楼之间空间较小的街谷,背风面和迎风面的示踪剂浓度平均比值可达8。浓度值沿楼层高度无明显变化;由于快车路旁松墙的阻挡和抬升作用,可能造成沿高度方向楼层中段的浓度偏高。在街谷外,除下风方路面上有一按下风距离的负幂指数衰减的浓度分布外,上风方路面上也有一按较大负幂指数衰减的分布。根据上述试验,给出了用以预测街谷中机动车辆排出的惰性气体污染物的扩散模式;模式中,对原生涡和小尺度湍流,做了分别处理。  相似文献   

9.
Large-eddy simulations were conducted to investigate the mechanism of pollutant removal from a three-dimensional street canyon. Five block configurations with aspect ratios (building height to length) of 1, 2, 4, 8 and $\infty $ were used to create an urban-like array. A pollutant was released from a ground-level line source at the centre of the target canyon floor. For smaller aspect ratios, the relative contribution of the turbulent mass flux to net mass flux at the roof level, which was spatially averaged along the roof-level ventilation area, was closer to unity, indicating that turbulent motions mainly affected pollutant removal from the top of the canyon. As aspect ratio increased, the relative contribution became smaller, owing to strong upwind motions. However, the relative contribution again reached near unity for the infinite aspect ratio (i.e. a two-dimensional street canyon) because of lowered lateral flow convergence. At least 75 % of total emissions from the three-dimensional street canyon were attributable to turbulent motions. Pollutant removal by turbulent motions was related to the coherent structures of low-momentum fluid above the canyons. Though the coherent structure size of the low-momentum fluid differed, the positions of low-momentum fluid largely corresponded to instantaneous high concentrations of pollutant above the target canyon, irrespective of canyon geometry.  相似文献   

10.
城市湍流边界层内汽车尾气扩散规律数值模拟研究   总被引:2,自引:1,他引:1  
吕萍  袁九毅  张文煜 《高原气象》2005,24(2):167-172
以纳维斯托克斯方程组、大气平流扩散方程、湍流动能及湍流动能耗散率方程组为基础.采用伪不定常方法,建立了一个数值模式.利用该模式列城市湍流边界层内流场结构及汽车排放污染物扩散规律进行了研究。结果表明:街谷内会形成一个涡旋型流场.汽车排放污染物浓度在地面及建筑物背风面产生堆积,且其沿高度方向的梯度变化在背风面大.迎风而小。随着街谷两侧建筑物屋顶风速的增大,峡谷内形成的涡旋流场的强度增大,污染物扩散速率增大:当屋顶来流与街道之间的夹角逐渐增大时.涡旋中心位置由街道中心偏向于背风面及更高层且污染物扩散速度加快。  相似文献   

11.
The impact of ground heating on flow fields in street canyons under different ambient wind speed conditions was studied based on numerical methods.A series of numerical tests were performed,and three factors including height-to-width(H/W) ratio,ambient wind speed and ground heating intensity were taken into account.Three types of street canyon with H/W ratios of 0.5,1.0 and 2.0,respectively,were used in the simulation and seven speed values ranging from 0.0 to 3.0 m s 1 were set for the ambient wind speed.The ground heating intensity,which was defined as the difference between the ground temperature and air temperature,ranged from 10 to 40 K with an increase of 10 K in the tests.The results showed that under calm conditions,ground heating could induce circulation with a wind speed of around 1.0 m s 1,which is enough to disperse pollutants in a street canyon.It was also found that an ambient wind speed threshold may exist for street canyons with a fixed H/W ratio.When ambient wind speed was lower than the threshold identified in this study,the impact of the thermal effect on the flow field was obvious,and there existed a multi-vortex flow pattern in the street canyon.When the ambient wind speed was higher than the threshold,the circulation pattern was basically determined by dynamic effects.The tests on the impact of heating intensity showed that a higher ground heating intensity could strengthen the vortical flow within the street canyon,which would help improve pollutant diffusion capability in street canyons.  相似文献   

12.
Large-eddy simulation (LES) is conducted to investigate the mechanism of pollutant removal from a two-dimensional street canyon with a building-height to street-width (aspect) ratio of 1. A pollutant is released as a ground-level line source at the centre of the canyon floor. The mean velocities, turbulent fluctuations, and mean pollutant concentration estimated by LES are in good agreement with those obtained by wind-tunnel experiments. Pollutant removal from the canyon is mainly determined by turbulent motions, except in the adjacent area to the windward wall. The turbulent motions are composed of small vortices and small-scale coherent structures of low-momentum fluid generated close to the plane of the roof. Although both small vortices and small-scale coherent structures affect pollutant removal, the pollutant is largely emitted from the canyon by ejection of low-momentum fluid when the small-scale coherent structures appear just above the canyon where the pollutant is retained. Large-scale coherent structures also develop above the canyon, but they do not always affect pollutant removal.  相似文献   

13.
This study summarizes the effects of avenues of trees in urban street canyons on traffic pollutant dispersion. We describe various wind-tunnel experiments with different tree-avenue models in combination with variations in street-canyon aspect ratio W/H (with W the street-canyon width and H the building height) and approaching wind direction. Compared to tree-free street canyons, in general, higher pollutant concentrations are found. Avenues of trees do not suppress canyon vortices, although the air ventilation in canyons is hindered significantly. For a perpendicular wind direction, increases in wall-average and wall-maximum concentrations at the leeward canyon wall and decreases in wall-average concentrations at the windward wall are found. For oblique and perpendicular wind directions, increases at both canyon walls are obtained. The strongest effects of avenues of trees on traffic pollutant dispersion are observed for oblique wind directions for which also the largest concentrations at the canyon walls are found. Thus, the prevailing assumption that attributes the most harmful dispersion conditions to a perpendicular wind direction does not hold for street canyons with avenues of trees. Furthermore, following dimensional analysis, an estimate of the normalized wall-maximum traffic pollutant concentration in street canyons with avenues of trees is derived.  相似文献   

14.
吕萍  袁九毅  张文煜 《高原气象》2004,23(4):534-539
利用数值模拟方法研究了微尺度街道峡谷范围内街谷几何结构及街道两侧建筑物高度对称性对街谷内流场及机动车排放污染物扩散规律的影响。结果表明:当街道峡谷高宽比>2.1时,街谷内的流场结构由一个完整的垂直涡旋变为上下两个反向运动的强弱不同的垂直涡旋。各类型街谷内污染物扩散水平从强到弱依次为迎风面建筑物高度大于背风面建筑物高度的街道峡谷,迎风面建筑物高度小于背风面建筑物高度的街道峡谷;平行型街道峡谷。  相似文献   

15.
A box model to simulate mass transfer inside deep street canyons and with atmospheric flow above is introduced and discussed. Two ideal deep street canyons with aspect ratios of 3 and 5 (the aspect ratio being the ratio between building height and street width H/W) are considered. This range of aspect ratios, found in many densely populated historical centres in Mediterranean cities as well as in other cities around the world, potentially creates high air pollutant concentration levels. Our model is based on a combination of analytical solutions and computation fluid dynamics (CFD) simulations using carbon monoxide (CO) as a tracer pollutant. The analytical part of the model is based on mass transfer velocity concepts while CFD simulations are used both for a preliminary validation of the physical hypothesis underlying the model (steady-state simulations) and to evaluate the concentration pattern with time (transient or wash-out simulations). Wash-out simulation curves were fitted by model curves, and mass transfer velocities were evaluated through a best-fitting procedure. Upon introducing into the model the contribution of traffic-produced turbulence, the modelled CO concentration levels became comparable with those obtained in real-world monitoring campaigns. The mass transfer rate between the canyon and the above atmosphere was then expressed in terms of an overall mass transfer velocity, which directly allows the evaluation of the mass transfer rate between the bottom volume of the canyon (pedestrian level) with the above atmosphere. Overall mass transfer velocities are reported as a function of the operating conditions studied (H/W = 3–5 and wind speeds = 2–8 ms−1). Finally, a simple expression is reported for determining pollutant concentrations at the pedestrian level based on the overall mass transfer velocity defined.  相似文献   

16.
Large-eddy simulations are conducted to investigate the effects of the incoming turbulent structure of the flow on pollutant removal from an ideal canyon. The target canyon is a two-dimensional street canyon with an aspect ratio of 1.0 (building height to street width). Three turbulent flows upwind of the street canyon are generated by using different block configurations, and a tracer gas is released as a ground-level line source at the centre of the canyon floor. Mean velocity profiles for the three flows are similar, except near the roof. However, the root-mean-square values of the velocity fluctuations and the Reynolds shear stress increase with the friction velocity of the incoming turbulent flow. The spatially-averaged concentration within the canyon decreases with increasing friction velocity. Coherent structures of low-momentum fluid, generated above the upwind block configurations, contribute to pollutant removal, and the amount of pollutant removal is directly related to the size of the coherent structure.  相似文献   

17.
Summary The paper presents an overview of the influence of street architecture on the wind and turbulence patterns in street canyons and discusses the effects on local air quality. The findings of recent experimental and numerical studies are summarized and wind-tunnel data sets are presented that illustrate the flow-field variability. It is shown that small-scale features of the street architecture play an important role. The formation of a vortex inside the street canyon is affected by the roof configuration. In shorter street canyons, the flow component along the street becomes important for pollutant transport. These results are of importance for urban air quality modeling in particular when dealing with pollution problems caused by road traffic. Furthermore, the findings should be taken into account in fast response models that are used to assess critical areas in the case of accidental or non-accidental releases of hazardous material in urban areas.  相似文献   

18.
Flow resistance, ventilation, and pollutant removal for idealized two-dimensional (2D) street canyons of different building-height to street-width (aspect) ratios $AR$ are examined using the friction factor $f$ , air exchange rate (ACH), and pollutant exchange rate (PCH), respectively, calculated by large-eddy simulation (LES). The flows are basically classified into three characteristic regimes, namely isolated roughness, wake interference, and skimming flow, as functions of the aspect ratios. The LES results are validated by various experimental and numerical datasets available in the literature. The friction factor increases with decreasing aspect ratio and reaches a peak at $AR = 0.1$ in the isolated roughness regime and decreases thereafter. As with the friction factor, the ACH increases with decreasing aspect ratio in the wake interference and skimming flow regimes, signifying the improved aged air removal for a wider street canyon. The PCH exhibits a behaviour different from its ACH counterpart in the range of aspect ratios tested. Pollutants are most effectively removed from the street canyon with $AR = 0.5$ . However, a minimum of PCH is found nearby at $AR = 0.3$ , at which the pollutant removal is sharply weakened. Besides, the ACH and PCH are partitioned into the mean and turbulent components to compare their relative contributions. In line with our earlier Reynolds-averaged Navier–Stokes calculations (Liu et al., Atmos Environ 45:4763–4769, 2011), the current LES shows that the turbulent components contribute more to both ACH and PCH, consistently demonstrating the importance of atmospheric turbulence in the ventilation and pollutant removal for urban areas.  相似文献   

19.
公路和城市街渠机动车大气污染物扩散模式发展综述   总被引:2,自引:0,他引:2  
随着城市机动车数量的增加,机动车尾气污染已经成为城市污染物的重要来源。研究机动车尾气扩散规律,可为公路建设,车流量控制,街道大气污染的监测、评价与防治提供科学依据。对公路机动车污染物扩散模型的发展进行了回顾,详细论述了高斯模式、数值模式、统计模式等模式的发展历程及其目前存在的问题,并比较了几种典型模式的性能优劣及其各种条件下的适用性。随后对城市街渠峡谷机动车污染物扩散模型进行专述,指出了街渠峡谷模式研究的难点在于街渠流场模拟,介绍了国外最新街渠流场研究方法。最后提出了当前机动车大气污染物扩散模型存在的主要困难,展望了其解决途径和发展的方向。  相似文献   

20.
Using a computational fluid dynamics(CFD)model,the effects of street-bottom and building-roof heating on flow in three-dimensional street canyons are investigated.The building and street-canyon aspect ratios are one.In the presence of street-bottom heating,as the street-bottom heating intensity increases,the mean kinetic energy increases in the spanwise street canyon formed by the upwind and downwind buildings but decreases in the lower region of the streamwise street canyon.The increase in momentum due to buoyancy force intensifies mechanically induced flow in the spanwise street canyon.The vorticity in the spanwise street canyon strengthens.The temperature increase is not large because relatively cold above-roof-level air comes into the spanwise street canyon.In the presence of both street-bottom and building-roof heating,the mean kinetic energy rather decreases in the spanwise street canyon.This is caused by the decrease in horizontal flow speed at the roof level,which results in the weakening of the mean flow circulation in the spanwise street canyon.It is found that the vorticity in the spanwise street canyon weakens.The temperature increase is relatively large compared with that in the street-bottom heating case,because relatively warm above-roof-level air comes into the spanwise street canyon.  相似文献   