首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 93 毫秒
1.
A series of model tests were performed on steel- and Perspex-made suction caissons in saturated dense marine sand to explore installation and extraction behaviors. The extractions of the caisson were conducted by applying monotonic loading or by pumping water into the caisson. Responses of suction caissons to pullout rates, aspect ratios, and extraction manners were examined. Test results show that a cone-shaped subsidence region occurs around the suction caisson during the suction-assisted installation. The pullout bearing capacity of the suction caisson in sand is dominated by the loading rate and the loading manner. For the suction caisson subjected to monotonic loading, the maximum bearing capacity is reached at the pullout rate of about 20.0?mm/s. The mobilized vertical displacement corresponding to the pullout capacity increases with increasing the pullout rate. The passive suction beneath the suction caisson lid reaches the maximum value when the pullout bearing capacity is mobilized. In addition, during the suction caisson extracted by pumping water into the caisson, the maximum pore water pressure in the caisson is obtained under the displacement of approximately 0.04 times the caisson diameter. The absolute values of the maximum pore water pressures for the suction caissons approximately equal those of the maximum vertical resistances at the monotonic pullout rate of 5 mm/s. When the vertical displacements of the suction caissons with the aspect ratio of 1.0 and 2.0 reach 0.92 and 1.77 times the caisson diameter, respectively, the seepage failure occurs around the caissons. Using a scaling method, the test results can be used to predict the time length required for the prototype suction caisson to be extracted from the seabed.  相似文献   

2.
A suction caisson can be extracted by applying reverse pumping water,which cannot be regarded as the reverse process of installation because of the dramatically different soil?structure interaction behavior.Model tests were first carried out in this study to investigate the extraction behavior of the modified suction caisson(MSC)and the regular suction caisson(RSC)in sand by reverse pumping water.The effects of the installation ways(suction-assisted or jacking installation)and the reverse pumping rate on the variations of the over-pressure resulting form reverse pumping water were investigated.It was found that neither the RSC nor the MSC can be fully extracted from sand.When the maximum extraction displacement is obtained,the hydraulic gradient of the sand in the suction caisson reaches the critical value,leading to seepage failure.In addition,the maximum extraction displacement decreases with the increasing reverse pumping rate.Under the same reverse pumping rate,the final extraction displacements for the RSC and MSC installed by suction are lower than those for the RSC and MSC installed by jacking.The final extraction displacement of MSC is almost equal to that of the RSC with the same internal compartment length.Based on the force equilibrium,a method of estimating the maximum extraction displacement is proposed.It has been proved that the proposed method can rationally predict the maximum extraction displacement and the corresponding over-pressure.  相似文献   

3.
Monotonic lateral load model tests were carried out on steel skirted suction caissons embedded in the saturated medium sand to study the bearing capacity. A three-dimensional continuum finite element model was developed with Z_SOIL software. The numerical model was calibrated against experimental results. Soil deformation and earth pressures on skirted caissons were investigated by using the finite element model to extend the model tests. It shows that the "skirted" structure can significantly increase the lateral capacity and limit the deflection, especially suitable for offshore wind turbines, compared with regular suction caissons without the "skirted" at the same load level. In addition, appropriate determination of rotation centers plays a crucial role in calculating the lateral capacity by using the analytical method. It was also found that the rotation center is related to dimensions of skirted suction caissons and loading process, i.e. the rotation center moves upwards with the increase of the "skirted" width and length; moreover, the rotation center moves downwards with the increase of loading and keeps constant when all the sand along the caisson's wall yields. It is so complex that we cannot simply determine its position like the regular suction caisson commonly with a specified position to the length ratio of the caisson.  相似文献   

4.
An investigation was conducted to obtain analytical solutions for the pullout behavior of a suction caisson undergoing inclined loads in sand. The inclined load is transformed into an equivalent load system in which the vertical, horizontal, and moment loads are applied on the center of the lid of the suction caisson. The vertical and lateral stiffness coefficients along the skirt of the suction caisson in sands are presented using the new three-dimensional elastic solutions taking into account the nonhomogeneous and nonlinear properties of the sand. The vertical, lateral, and rocking stiffness coefficients on the base of the suction caisson are presented considering the solutions of a hollow rigid cylindrical punch acting on the surface of a soil. The yield, pullout, and failure for sands with the nonhomogeneous and nonlinear characteristics are taken into consideration. The effects of the load inclination, the loading depth, and the aspect ratio on the pullout load capacity of the suction caisson are presented. Behaviour of the suction caisson in sand prior to failure is clarified from the relationship between tensile load, displacement, and rotation and that between depth, vertical pressure, and lateral pressure.  相似文献   

5.
Concrete suction caissons have been successfully used as breakwaters or seawalls in recent years. The relative large wall thickness-to-diameter ratio of a concrete caisson can lead to the formation of a full soil heave plug that may cause difficulties in the installation of concrete caisson in clay. One way to overcome this limitation is to use a tampered tip for the caisson wall. An analytical method is proposed in this article to calculate the minimum suction pressure required to penetrate a caisson and the maximum allowable suction pressure that can be applied to avoid too much soil heave plug during the installation of the suction caisson. Four model tests were conducted in normally consolidated clay to study the installation process of a concrete suction caisson with tampered tip and to verify the proposed analytical method. The height of the soil heave plug in the caisson with a tampered tip is observed to be about half of that in the caisson with a flat tip.  相似文献   

6.
Dai  Guo-liang  Zhu  Wen-bo  Zhai  Qian  Gong  Wei-ming  Zhao  Xue-liang 《中国海洋工程》2019,33(6):685-693
Suction caisson foundation derives most of their uplift resistance from passive suction developed during the pullout movement. It was observed that the passive suction generated in soil at the bottom of the caisson and the failure mode of suction caisson foundation subjecting pullout loading behaves as a reverse compression failure mechanism.The upper bound theorems have been proved to be a powerful method to find the critical failure mechanism and critical load associated with foundations, buried caissons and other geotechnical structures. However, limited attempts have been reported to estimate the uplift bearing capacity of the suction caisson foundation using the upper bound solution. In this paper, both reverse failure mechanisms from Prandtl and Hill were adopted as the failure mechanisms for the computation of the uplift bearing capacity of the suction caisson. New equations were proposed based on both failure mechanisms to estimate the pullout capacity of the suction caisson. The proposed equations were verified by the test results and experimental data from published literature. And the two solutions agree reasonably well with the other test results. It can be proved that both failure mechanisms are reasonably and more consistent with the actual force condition.  相似文献   

7.
A series of model tests was conducted in sand to explore the anti-uplift behavior of suction caissons, considering the effects of aspect ratios, load inclination angles and loading positions. This paper emphasizes on analyzing the deformation characteristic and the mechanism of the suction caissons under various loading conditions. The movement modes of the suction caisson are different when the load inclination angle increases from 0° to 90° corresponding to various mooring positions. The pull-out bearing capacity decreases with load inclination angles increasing. When the load inclination angle changes from 0° to 60°, the bearing capacity reduces more significantly than that between inclination angle of 60° and 90°. While the load inclination angle is relatively small, the pull-out capacity of the suction caisson decreases after reaching the peak as the loading position moves downwards. Moreover, the optimum loading position locates between 2/3 and 3/4 of the caisson length. The optimum loading position is at the bottom of the caisson when the load inclination angle exceeds 60°. However, the influence of the loading position on the pull-out capacity of the caisson can be ignored while the load inclination angle equals to 90°. The pull-out bearing capacity increases as the aspect ratio increases but the aspect ratio has no effect on the deformation characteristic of the suction caisson.  相似文献   

8.
Li  Da-yong  Li  Shan-shan  Zhang  Yu-kun  Chen  Fu-quan 《中国海洋工程》2019,33(2):198-206
The modified suction caisson(MSC) is a novel type of foundation for ocean engineering, consisting of a short external closed-top cylinder-shaped structure surrounding the upper part of the regular suction caisson(RSC). The MSC can provide larger lateral bearing capacity and limit the deflection compared with the RSC. Therefore, the MSC can be much more appropriate to use as an offshore wind turbine foundation. Model tests on the MSC in saturated sand subjected to monotonic lateral loading were carried out to investigate the effects of external structure sizes on the sand surface deformation and the earth pressure distribution along the embedded depth. Test results show that the deformation range of the sand surface increases with the increasing width and length of the external structure. The magnitude of sand upheaval around the MSC is smaller than that of the RSC and the sand upheaval value around the MSC in the loading direction decreases with the increasing external structure dimensions. The net earth pressure in the loading direction acting on the internal compartment of the MSC is smaller than that of the RSC at the same embedded depth. The maximum net earth pressure acting on the external structure outer wall in the loading direction is larger than that of the internal compartment, indicating that a considerable amount of the lateral load and moment is resisted by the external skirt structure.  相似文献   

9.
A study was made to present analytical solutions of pullout load capacity for a suction caisson subjected to inclined tension in clay. The inclined tension on the skirt of the suction caisson is transformed into an equivalent system comprised of the vertical, horizontal, and moment load applied on the center of the lid. The vertical and horizontal stiffness coefficients along the skirt of the suction caisson in clay are presented by three-dimensional elastic solutions considering the nonhomogeneous and nonlinear property of clay. The vertical, horizontal, and rocking stiffness coefficient of the suction caisson on the base are presented considering the solutions of a hollow rigid cylindrical punch acting on the surface of clay. The envelopes of the horizontal and vertical ultimate load capacity for clay are presented. The yield, pullout, and failure for clay are taken into consideration. The effects of load inclination, loading depth, and aspect ratio on the pullout load capacity are shown. Behavior of the suction caisson in clay up to failure is investigated using the relationship between tensile load and displacement and that between depth, vertical, and horizontal pressure.  相似文献   

10.
Determining the ultimate capacity of suction caissons in response to combined vertical, horizontal, and moment loading is essential for their design as foundations for offshore wind turbines. However, the method implemented for stability analysis is quite limited. Numerical limit analysis has an advantage over traditional limit equilibrium methods and nonlinear finite element methods in this case because upper and lower bounds can be achieved to ensure that the exact ultimate capacity of the caisson falls within the appropriate range. This article presents theories related to numerical limit analysis. Simulations are conducted for centrifuge model tests, the findings of which reveal the ability of numerical limit analysis to deal with the inclined pullout capacity of suction caissons. Finally, this article proposes an estimation of the ultimate capacity of a 3.5 MW offshore wind turbine foundation on normally consolidated clay based on the typical environmental parameters of Bothkennar, Scotland. Undrained failure envelopes and safety factors are obtained for suction caissons with different embedment ratios. Failure mechanisms, plastic zones, clay stress distributions, and the influence of the skin friction coefficients of caissons are discussed in detail.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏