首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
Peat and soft soil deposits are abundant in Malaysia. Studies using electrokinetic geosynthetics (EKG) such as prefabricated electric vertical drains (EVD or ePVD) have shown the potential for the application of these materials in electrokinetic strengthening of soft clays and increasing solids content in mining tailings and sludges. There are no studies reported on the effectiveness of electro-osmosis using EVD in peat. Laboratory experiments were carried out to investigate the effectiveness of electro-osmotic stabilization of two peat samples and a slightly organic clayey silt sample, from the North Sarawak region. Commercially available EVD was used to induce electro-osmosis and drainage of pore water. The influence of voltage gradient, organic content, initial water content, anode–cathode configuration and presence of roots on electro-osmotic consolidation was investigated. Electro-osmotic consolidation using EVDs was effective in the improvement of peat, over a large range of initial water contents. An increase in the voltage gradient generally improved consolidation. The maximum voltage gradient for optimum results appeared to be in the region 120 V/m. The 2anodes-1cathode configuration performed better than the 1anode-1cathode configuration. The presence of roots reduced the electro-osmosis effect.  相似文献   

2.
电渗固结是促进低渗透性软土排水固结的有效方法。为了揭示不同电势梯度影响高岭土电渗固结的基本规律,在自制电渗试验装置上对高岭土进行电渗试验。试验过程中测量电流、排水量、沉降量以及有效电压随时间的变化,并进行单位排水能耗分析。基于电渗固结多场耦合控制方程,实现土体电渗固结全耦合分析的有限元数值方法,计算结果与解析解吻合良好,验证了程序的有效性。为预测不同电势梯度下土体沉降量随时间的变化关系,分别对0.5,1.0,1.5 V/cm 3种电势梯度电渗固结试验进行数值模拟分析,获得模型表面沉降量分布、阳极超静孔隙水压力时空发展规律、阳极位置固结度等曲线,计算结果和试验结果吻合良好,可为实际电渗试验提供理论指导。  相似文献   

3.
边坡电渗模型试验及能量分析法数值模拟   总被引:4,自引:0,他引:4  
庄艳峰  王钊  陈轮 《岩土力学》2008,29(9):2409-2414
采用导电塑料制成的电动土工合成材料(EKG)进行了15.5 d的边坡电渗加固试验,测定了电渗之后土体等含水率分布曲线。试验结果表明,电渗加固效果是随时间从阳极到阴极逐渐扩展的,因此,越靠近阳极接入点的土体加固效果越好,越靠近阴极末端的土体加固效果越差。提出了电渗能量分析法,该方法仅要求黏性土体在排水固结开始的初始时刻是处于饱和状态,而在排水固结进行的过程中土体可以是饱和的,也可以是非饱和的。提出了基于能量分析法的电渗过程数值模拟方法,并对试验过程进行了数值模拟,模拟结果与实测结果能够较为吻合。  相似文献   

4.
为深入研究电渗排水对土体工程性质的影响,采用铁丝为电极,在模型箱内对南京市某河道淤泥质土进行电渗排水 模拟试验。电渗前后土的物理力学性质对比分析表明:电渗后土体的液、塑限与塑性指数均降低;电渗前后土体在相同含 水量和干密度情况下进行直接剪切试验,发现电渗后土体的凝聚力和内摩擦角均降低,即电渗后土体在特定情况下出现了 强度衰减的现象。论文基于土中阳离子流失机理对土体在特定情况下的强度衰减现象进行了微观解释。另外,利用提出的 新的电渗机理从微观角度解释了电渗过程中土体开裂现象,阳极因快速失水,最早出现裂隙,但裂隙延展范围较小;阴极 含水量始终高于阳极,且失水速度较慢,裂隙延展范围较大。值得一提的是,在以往的研究中并未关注到电渗加固过程中 土中阳离子流失对电渗后土体性质的影响。  相似文献   

5.
针对传统电渗法治理淤泥质土过程中排水效率低且治理后土体不均匀等问题,从改变软黏土颗粒自身持水特性角度出发,提出采用新型有机高分子材料阴离子型聚丙烯酰胺(APAM)联合电渗法治理淤泥质土的思路。利用自制的一维电渗固结试验装置,探究絮凝−电渗法联合作用机制以及不同絮凝剂掺入比对电渗排水加固效果的影响规律。试验结果表明:与传统电渗法相比较,絮凝剂 APAM 的掺入减少了软黏土颗粒表面的结合水膜厚度,使得淤泥质土的前期电渗排水速率和累计排水量显著提升,从而降低了电渗法的平均能耗系数;同时,絮凝剂高分子长链的“吸附架桥”作用增强了土颗粒的黏结力和絮凝沉积效果,有效缓解了电渗过程中细小黏粒迁移集聚而造成的阴极淤堵问题;治理后淤泥质土的抗剪强度大幅增高,土体的均匀性也得到了明显改善,且当絮凝剂 APAM 掺入比为 0.30% 时,土体的电渗排水固结效果最佳。  相似文献   

6.
为解决目前电渗应用的高能耗困境及大尺寸模拟困难等问题,提出针对低渗透性、高含水率土体的电动-水力渗流协同作用的三维固结方法。自行研制了一套阴极-集水-排水协同作用的多功能集排水系统,采用间歇式抽水代替连续抽水。采用三维电动-水力渗流固结系统对取自贡湖湾湿地和白旄堆场的2种不同太湖底泥进行了电渗试验研究,同时对白旄堆场太湖底泥进行了传统一维电渗固结试验,并对2种试验条件下的单位体积排水能耗和单位体积单位排水量能耗等关键指标进行了对比。结果表明:三维集水井设计可大大降低土体阴极附近电阻,间断性提高系统电流,提高排水效率,降低电渗总能耗;间歇式抽水可间歇性降低系统内总电流,利用电动-水力协同作用,保持系统渗流的连续性;三维电动-水力渗流固结系统的电流呈周期性减小—增大模式,并且降低速率较慢,尤其对于有机质含量较高的土体,电渗过程电流始终保持在一个较高的水平,提高了排水固结效率。三维电动-水力渗流固结系统的单位体积排水能耗和单位体积单位排水量能耗分别约为一维电渗系统的2/3和1/30。在高含水量软土固结排水中具有显著的节能效果。三维电动-水力渗流固结系统可以提高排水固结效率、大幅度降低能耗,为...  相似文献   

7.
针对真空预压作用下排水板淤堵与排水条件受限等问题,提出絮凝−真空−电渗联合加固法。首先通过沉降柱试验确定合适的有机絮凝剂,然后采用该絮凝剂,分别在 48 h(开始介入真空预压,固结度为0 )、60 h(排水速率明显下降,固结度为60%)及 84 h(排水速率近乎 0,固结度为 80%)时介入电渗,开展不同电渗介入时间的絮凝−真空−电渗联合加固试验。试验从排水量、十字板剪切强度、含水率与孔压等对比分析联合加固的有效性,确定其最佳电渗介入时间。试验结果表明:当固结度为 80% 时介入电渗,絮凝−真空−电渗联合加固法能够有效地抑制排水速率减小的趋势,增长有效排水时间。同时,土体的抗剪强度和承载力亦得到大幅提升,孔压消散更加均匀。此外,在阳离子聚丙烯酰胺絮凝剂的作用下,初始排水速率快,在一定程度上使土体的渗透性得到提升,有效地解决了排水板淤堵问题,说明絮凝−真空−电渗联合加固法具有较强的优越性。  相似文献   

8.
张雷  王宁伟  景立平  方晨  董瑞 《岩土力学》2019,40(9):3493-3501
采用辽宁沿海地区淤泥质软土对铁、铜、铝和新型复合电极等不同电极材料进行室内电渗排水固结试验,从有效电势、电流、排水量与排水速率、能耗、电渗后土体含水率和承载力等对电渗效果进行分析。新型复合电极材料是由碳纤维、塑料排水板与铁片组成,其充分利用各种材料的优点,既解决了铁与碳纤维直接相连通电后易断的问题,又解决了电极腐蚀严重的问题。多组试验结果表明:新型复合电极材料的电渗排水固结使土体的加固强度提升较高,且相对均匀,加固强度达到160 kPa以上的土体面积占加固总面积的75%,说明新型复合电极材料的优越性。金属电极的腐蚀较为严重,且主要发生在阳极。根据电渗后阳极的腐蚀比,新型复合电极的腐蚀量明显低于金属电极,且新型复合电极可提高加固效果,节约电极材料成本。  相似文献   

9.
In this paper, a numerical solution for the electro-osmosis consolidation of clay in multi-dimensional domains at large strains is presented, with the coupling of the soil mechanical behaviour, pore water transport and electrical fields being considered. In particular, the Modified Cam Clay model is employed to describe the elasto-plastic behaviour of clay, and some empirical expressions are used to consider the nonlinear variation of the hydraulic and electrical conductivities of the soil mass during the consolidation processes. The implementation of the theoretical model in a finite element code allows for analysis of the evolution of the transient response of the clay subjected to electro-osmosis treatment. The proposed model is verified via comparison with data from a large strain electro-osmosis laboratory test, to demonstrate its accuracy and effectiveness. Various numerical examples are also investigated to study the deformation characteristics and time-dependent evolution of the excess pore pressure. Finally, a well-documented field application of electro-osmosis is simulated to provide further verification. The results show that the numerical solution is effective in predicting the nonlinear behaviour of clay during electro-osmosis consolidation.  相似文献   

10.
By applying linear poro-elasticity theory, the body force effect on steady soil consolidation, i.e., settlement, caused by constant water table depression due to groundwater pumping was investigated. The result shows that when the soil is soft or thick, or both, neglecting the body force effect can lead to severe underestimation of soil displacement and incremental effective stress. However, the transient response of soil consolidation was not analyzed. In addition, the water table depression due to groundwater pumping in fact varies with time. In this study, the body force effect on transient consolidation of soil subjected to variable water table depression is further examined. A poroelastic consolidation numerical model is developed herein to conduct this examination.  相似文献   

11.
聚丙烯纤维加固软土的试验研究   总被引:6,自引:0,他引:6  
唐朝生  施斌  蔡奕  高玮  陈峰军 《岩土力学》2007,28(9):1796-1800
为了研究聚丙烯纤维加固软土的效果和机制,改善石灰土和水泥土的脆性破坏形式。在试验中将纤维按质量百分比为0.05 %,0.15 %和0.25 %的掺量分别掺入到素土、石灰土和水泥土中,按不同的配比配制了20组试样,进行了无侧限抗压强度试验。试验结果显示:纤维的加入能在小范围内提高素土的无侧限抗压强度,并且强度值随纤维掺量的增加而增加;而在石灰土和水泥土中只要掺入少量的纤维就能使无侧限抗压强度值得到极大的提高,增加了石灰土和水泥土的抗拉强度,改善了它们的脆性破坏形式,并使其水稳性得到改善。  相似文献   

12.
A multi-column composite foundation is a new concept utilizing different column types with varying lengths and diameters to support the embankment fill and to mobilize the strength and stiffness of the soil at shallow depths. This study presents the results of finite element analyses using the finite element software PLAXIS to investigate the consolidation behavior of a road embankment constructed on a multi-column composite foundation. The finite element results are calibrated for a period of 200 days. The settlement, horizontal displacement, differential settlement, column axial force, and the development and dissipation of excess pore pressure are presented and discussed in detail. It is concluded that a multi-column composite foundation allows a fast rate of consolidation and significantly increases the embankment stability. A multi-column composite foundation formed by CFG–lime columns is more effective than one formed by SC–lime columns. The CFG–lime columns improve the long-term stability of the embankment because the compression modulus of CFG columns is significantly greater than that of SC columns.  相似文献   

13.
宋晶  王清  孙铁  李晓茹  张中琼  焦志亮 《岩土力学》2010,31(9):2935-2940
利用真空预压法处理吹填土时,细颗粒常堵塞排水管,导致土体排水不畅。为提高吹填土固结效率,采用自重沉淤排水与加负压排水固结相结合的方式在室内进行吹填土固结试验。试验第一阶段用排水管作为吹填土自重沉淤的竖向排水通道;第二阶段以装入中粗砂的排水管作吹填土排水通道,同时也是压力传递通道。试验监测到吹填土固结过程中不同位置孔隙水压力的变化,通过监测数据着重研究自重沉淤排水阶段吹填土的固结规律。借助渗流平衡方程确定吹填土在自重沉淤阶段孔隙水压力变化主要由排水管中水位、单位土面积控制,解释自重沉淤阶段孔隙水压力变化机理。同时,为了减小由于排水距离远近造成的固结不均,利用自重沉淤与加压固结结合的方法使吹填土达到较为理想的固结效果,将砂井设计理论与孔隙水压力变化曲线相结合确定排水管有效排水范围等效直径,为实际工程提供排水管间距的设计参数。  相似文献   

14.
This paper presents the theoretical background of an elastic electro-osmosis consolidation model for saturated soils experiencing large strains, which considers volumetric strains induced by changes in both the hydraulic and electric driven pore water flows. Three fully coupled governing equations, considering the soil mechanical behaviour, pore water transport and electrical field, and their numerical implementation within an updated Lagrangian finite element formulation, are presented. The proposed model is first verified against a classical one-dimensional analytical solution for electro-osmosis consolidation to demonstrate its accuracy and efficiency. Then, various numerical examples are investigated to study the deformation characteristics and time dependent evolution of excess pore pressure. Finally, the importance of considering large strains in a consistent and proper way is demonstrated, and differences compared to models based on small strain theory are highlighted.  相似文献   

15.
从原理分析,采用疏干排水、真空排水、电渗排水都能排除土料中的水分。为了确定能否在工程中使用,对三种方法进行试验。三种方法开始时排水速率较快,都能降低土体的含水量,提高土体密度。得出电渗方法排水效果最好。  相似文献   

16.
In present study, the non-linear variations of soil compressibility, hydraulic and electro-osmosis conductivities were analyzed through laboratory experiments, and incorporated in a one-dimensional model. The analytical solutions for excess pore water pressure and degree of consolidation were derived, and numerical simulations were performed to verify its effectiveness. The results indicated that both the non-linear variations of hydraulic and electro-osmosis conductivities showed remarkable impacts on the excess pore water pressure and degree of consolidation, especially for soils with relative high compressibility. A further comparison with previous analytical solutions indicated that more accurate predictions could be obtained with the proposed analytical solutions.  相似文献   

17.
孟庆山  汪稔  王吉利 《岩土力学》2004,25(Z2):482-486
介绍了利用重锤夯实法加固表层填土与排水固结法加固深层软土联合处理库内层状软土地基的方法,在填土静荷载和塑料排水板作用下淤泥质软土很快完成主固结沉降,重锤夯实法使表层填土受到动力压密,软土和填土强度得以提高.试验结果表明,排水固结过程中填土层的单位沉降量远小于淤泥质软土,重锤夯实法的有效加固深度可以达到地表下3.5 m,影响深度可达6.0 m.联合采用两种地基处理方法可以有效提高层状地基承载力.  相似文献   

18.
李瑛  龚晓南 《岩土力学》2012,33(1):89-95
通过室内1:5的模型试验进行了等电势梯度下2 m×1 m和1 m×0.5 m两种工程常见矩形布置电极间距下的软黏土电渗性状的研究。利用监测排水量、排水速率、电流、电势、含水率和pH值等指标,对不同电极间距试样的电渗处理效果、能量效率和电极腐蚀等方面进行了分析。结果表明:保持电势梯度不变而减半电极间距能够加快电渗排水,降低土体含水率,减小能量消耗和电极界面电阻,但也会导致土体pH值变化和阳极腐蚀量的增大。此外,采用较小的电极间距可使损失在电极和土接触面上的电势降减小,但损失的电势降占电源电压的比例增大。  相似文献   

19.
电阻率测试技术在水泥土深层搅拌法工程中的应用研究   总被引:18,自引:5,他引:13  
于小军  刘松玉 《岩土力学》2003,24(4):592-597
通过水泥土电阻率试验研究分析,可知水泥土电阻率与无侧限抗压强度、水泥掺入比、龄期成正相关,即随着无侧限抗压强度、水泥掺入比、龄期的增大而增大;水泥土电阻率与含水量负相关,即随着含水量增大而降低;影响水泥土电阻率的主要因素依次为含盐量、水泥掺入比、天然含水量、粉煤灰含量、石灰含量。进行了水泥土电阻率和喷粉搅拌桩桩身抗压强度、芯样力学性状和标贯击数的对比研究以及野外电测井、电测深剖面勘探,探索了电阻率测试技术在水泥土深层搅拌法工程中的应用。  相似文献   

20.
采用核磁共振技术,对不同配比的水玻璃、石灰+粉煤灰及石灰+粉煤灰+水玻璃的固化盐渍土的微观特征进行检测,结合无侧限抗压强度试验,分析了各固化方案的盐渍土固化效果,讨论了强度成因的微观特征机制。结果表明,不同固化土的孔隙特征有较大差异。石灰+粉煤灰固化盐渍土大孔隙减少;石灰+粉煤灰+水玻璃固化盐渍土孔隙总体积减少,但同时有大孔隙生成;水玻璃固化盐渍土孔隙总体增多,但随水玻璃浓度增大,孔隙体积有所减小。石灰+粉煤灰+水玻璃固化盐渍土抗压强度远大于其他固化方案,但是其孔隙结构并不是最优,说明颗粒间的胶结情况对固化效果的影响远大于孔隙特征。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏