首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 611 毫秒
1.
Concentration data obtained by instrumental neutron activation analysis (INAA) are presented for up to 36 chemical elements in 93 geochemical reference samples, including some for which there are little previous data. Because all data are based on at least three independent analyses, and for many of the data the uncertainty associated with counting is an insignificant source of error, the values presented here are considered of higher precision than generally reported by INAA. Information on subsampling error (sample heterogeneity) is also presented.  相似文献   

2.
National Institute of Science and Technology (NIST) silicate glass SRM 610 is widely used as a certified reference material for various micro-analytical techniques such as SIMS or laser ablation ICP-MS. SRM 610 has been nominally doped with sixty one trace elements at the 500 μg g−1 level, but certified concentration data exist for only a few of these elements. This study reports concentration data for fifty nine trace elements obtained by ICP-MS, SSMS, LIMS, TIMS, INAA, AAS, and PIXE analyses of two different SRM 610 wafers. Most elements fall within a 10% band around a median value of about 440 μg g−1. The REE concentrations are shown to be constant to 3% (1 σ), thus emphasizing the value of SRM 610 as a reference material for REE analyses.
Comparison of our values with published data suggests that different SRM 610 wafers are, within errors, chemically identical for most elements. Exceptions to this general rule appear to be restricted to elements which were partly lost during the production of the glass, e.g. Ag and Br. On the basis of six independent determinations of Rb concentrations, which are systematically lower by a few percent than the reported NIST value, we argue that the certified Rb concentration may not be representative for all distributed SRM 610 wafers.  相似文献   

3.
Cerium has been determined in thirty-six international geochemical reference samples using candoluminescence emission analysis. Samples are fused with sodium peroxide in nickel crucibles and interfering elements are removed by an ion exchange technique.
Cerium values obtained in the present work generally lie within ranges reported in the literature or close to the upper or lower ends of these ranges. Candoluminescence values for cerium compare favourably with previously reported INAA values for most of the geochemical reference samples analysed in the present study.  相似文献   

4.
Six roches standards de I'USGS : GXR-1 à GXR-6 ont été analysées par activation neutronique instrumentale (INAA) pour le dosage de 17 éléments traces et par fluorescence X (XRF) pour les autres éléments difficiles à doser par activation neutronique. Les travaux précédemment publiés par Gladney et al. ont été pris comme référence en particulier les valeurs recommandées (R.V.) qui sont généralement en bon accord avec nos résultats. Quelques remarques et corrections sont proposées pour expliquer certaines disparités.
Six United States Geological Survey's (USGS) Geochemical Exploration References Samples (GXR) have been analyzed by instrumental neutron activation analysis (INAA) for the determination of seventeen trace elements and by X-ray fluorescence spectrometry (XRFS) for other trace elements difficult to determine by INAA. Our results compare favourably with the values recommended by E.S. Gladney et al. Some suggestions and corrections are proposed to explain some discrepancies.  相似文献   

5.
The paper presents data on the leaching efficiency of rare-earth (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) and radioactive (Th and U) elements by various reagents from alkaline rocks of the Lovozero Massif. Element concentrations were analyzed by ICP-MS and instrumental neutral activation (INAA). A new complex technique is suggested for analyzing elements on the solid phase of polymer hydrogels. This technique makes it possible to enhance the sensitivity and selectivity of INAA when these elements are simultaneously contained in rocks. Data are presented on the selective leaching of trace elements and the application of environmentally safe reagents.  相似文献   

6.
Instrumental neutron activation analysis results for 20 trace elements (Sc, Cr, Co, Ni, Rb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Tm, Yb, Lu, Hf, Ta, Th) and for two major elements (Na and Fe) in two geochemical reference samples issued by the "Centre de Recherches Pétrographiques et Géochimiques" are reported and compared with available literature values. In general our results agree well with recommended or proposed values.  相似文献   

7.
We present new concentration data for twenty four lithophile trace elements in NIST certified reference material glasses SRM 610-SRM 611 in support of their use in microanalytical techniques. The data were obtained by solution ICP-MS and isotope dilution TIMS analysis of two different sample wafers. An overall assessment of these new results, also taking into account ion probe studies that have been published in the literature, shows that these wafers can be considered to be homogeneous. Therefore, individually analysed wafers are believed to be representative of the entire batch of the SRM 610-611 glasses. Possible exceptions are the alkali metals (and a few volatile or non-lithophile trace elements). The analysed concentrations range between 370 μg g−1 (Cs) and 500 μg g−1 (Sr) and agree well with published values. On the basis of our new data and data recently published in the literature we propose "preferred average" values for the elements studied. These values are, within a few percent, identical to those proposed by other workers.  相似文献   

8.
To test whether the silicate reference glasses BAM‐S005‐A and BAM‐S005‐B from BAM (The Federal Institute for Materials Research and Testing, Germany) are suitable materials for microanalysis, we investigated the homogeneity of these reference glasses using the microanalytical techniques EPMA, LA‐ICP‐MS and SIMS. Our study indicated that all major and most trace elements are homogeneously distributed at micrometre sampling scale in both types of glass. However, some trace elements (e.g., Cs, Cl, Cr, Mo and Ni) seem to be inhomogeneously distributed. We also determined the composition of BAM‐S005‐A and BAM‐S005‐B. The EPMA data of major elements confirmed the information values specified by the certificate. With the exception of Sr, Ba, Ce and Pb, our trace element data by LA‐ICP‐MS were also in agreement with the certified values within the stated uncertainty limits. The reasons for the discrepancy in these four elements are still unclear. In addition, we report new data for twenty‐two further trace elements, for which the concentrations were not certified. Based on our investigation, we suggest that both of these materials are suitable for many microanalytical applications.  相似文献   

9.
All data reported by 200 analysts (106 laboratories) are presented for the four ANRT samples: Diorite DR-N, Serpentine UB-N, Bauxite BX-N and Disthène DT-N. Recommended values are given for the major and minor elements. As far as the as trace elements are concerned, DR-N has been characterized for 35 elements whereas the other three samples have been for only 20 elements. Wherever possible, brief comments have been inserted so as to explain our way of assigning recommended or proposed values.
After more than a decade of existence the total number of data reported for all the four samples reach only 3200 units which are not sufficient enough for a valid evaluation of compiled data. It is also pointed out that these samples are most likely to be available even during the next century as they have been prepared in large quantities of the order of one ton. A plea is therefore made for contribution of more data particularly for trace elements and for major elements which are present as trace elements in UB-N, BX-N and DT-N.  相似文献   

10.
Literature data show that refractory-lithophile elements in most chondrite groups are unfractionated relative to CI chondrites; the principal exception is the EL-chondrite group whose observed falls (all of which are type 6) are depleted in Ca and light REE. In contrast, literature data and our new INAA data on EL3 PCA 91020, EL3 MAC 88136 and EL4 Grein 002 show that some replicates of these samples have nearly flat REE patterns (unlike those of EL6 chondrites); other replicates exhibit fractionated REE patterns similar to those of EL6 chondrites. Petrographic examination shows that many EL6 (and some EL3 and EL4) chondrites are impact-melt breccias or contain impact-melted portions. We suggest that the same impact processes that formed these breccias and produced melt are responsible for the observed bulk compositional fractionations in refractory-lithophile elements, i.e., EL6 chondrites were produced from initially unequilibrated EL3 material. When large amounts of impact heat were deposited, plagioclase and/or oldhamite (CaS) (the major REE carriers in enstatite chondrites) may have been melted and then transported appreciable (>10 cm) distances. EL6 chondrites represent the residuum that is depleted in REE (particularly in LREE) and Ca. Unlike the case for EL chondrites, our new INAA data on ALH 84170, EET 87746 and SAH 97096 (all EH3) show some scatter but are consistent with the EH group having uniform refractory-lithophile abundances.  相似文献   

11.
In the past, there has been little interest in the trace element characteristics of quartz, and in consequence little activity in the trace element characteristics of reference materials with high silicon content. The main purpose of this paper is to contribute to the characterisation of two international certified reference materials, BCS 313/1 from the Bureau of Analysed Samples, (BAS), UK and SRM 1830 from the National Institute of Standards and Technology (NIST), USA. BCS 313/1 was analysed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS), solution ICP-MS and instrumental neutron activation analysis (INAA). NIST SRM 1830 was analysed by LA-ICP-MS and INAA. Analytical results are reported for more than forty elements, most of them for the first time. For most elements, the results obtained by the different methods agree within 15 % relative. The recent, heightened interest in quartz and in particular the precise determination of trace0element contents in natural quartz samples requires the use of well characterised reference materials such as BCS 313/1 and SRM 1830, to which this study is designed to contribute.  相似文献   

12.
淮北煤中几种具有环境意义的微量元素分布   总被引:6,自引:1,他引:5  
通过中子活化法,对淮北煤田主采煤层中和相对应的灰中几种具有环境意义的微量元素含量进行了测试,分析了它们在煤中和灰中的含量分布,并与中国和华北煤田煤中的平均值进行了对比,以便为煤和煤灰的综合利用提供基础资料。   相似文献   

13.
The concentrations of 25 trace elements have been determined in 15 international standard rock samples by isotope-dilution spark source mass spectrometry (ID-SSMS). This technique yields reliable data down to the ppb concentration range. The agreement between most of our data and recommended values is within 10%. However, for reference samples with low trace element contents (BIR-1, NIM-N, PCC-1, DTS-1), differences between our data and the literature can be as large as a factor of 80.  相似文献   

14.
The National Research Council (NRC), Ottawa, Canada sandy marine sediment reference material HISS-1 was characterised for thirty-seven trace elements by neutron activation optimised irradiation, cooling and counting protocols using the low power Miniature Neutron Source Reactor (MNSR) as a neutron source. This INAA methodology quantified twenty additional elements including ten rare earth (Ce, Dy, Eu, Ho, La, Lu, Nd, Sm, Tb and Yb) and ten other elements (Ba, Br, Cs, Ga, Hf, Rb, Sc, Ta, Th and Zr) missing in the final NRCC certification. A large number of values produced by different irradiation schemes together with the use of certified reference materials in the quantification step that showed good precision, provided confidence in the results. The reliability of the REE data was checked by plotting chondrite-normalised graphs.  相似文献   

15.
Data was obtained for the rare earth elements (REE) by instrumental neutron activation analysis (INAA) and inductively coupled plasma-mass spectrometry (ICP-MS) in twenty geological reference materials. In general, the precision obtained by ICP-MS is better for the light REE, decreasing with increasing atomic number. This is partly a result of the occurrence of the heavy REE at low concentrations. The precision of the data obtained by INAA is good (5% RSD). The data obtained also showed that for the elements determined by both methods, the accuracy is similar for the light REE and better for the middle and heavy REEs by INAA. Higher uncertainty is achieved by ICP-MS mainly for elements at very low concentrations, occurring at about ten times the chondritic values.  相似文献   

16.
Data on thirty-four minor and trace elements including all rare earth elements (REE) are reported for two kimberlitic international reference materials (SARM-39, MINTEK, RSA and MY-4, IGEM, Russia) by inductively coupled plasma-mass spectrometry (ICP-MS), some of them for the first time. Four digestion techniques (open acid, closed vessel acid, microwave and lithium metaborate fusion digestion) were used for the decomposition of samples for analysis by ICP-MS. Three other reference materials (USGS BHVO-1, CRPG BR-1 and ANRT UB-N) were analysed simultaneously using the same analytical methodology to assess the precision and accuracy of the determinations. The data obtained in this study compare well with working values wherever such values are available for comparison. Though open acid digestion was found to be very rapid, effective and convenient for the determination of several trace elements in kimberlitic samples, recoveries for heavy rare earth elements (HREE) were lower than the respective recoveries obtained by the other decomposition techniques used. The precision obtained was better than ± 6% RSD in the majority of cases with comparable accuracy. Chondrite-normalised plots of each RM for all the digestion techniques were smooth. The new data reported on the two kimberlitic reference materials make these samples useful for future geochemical studies of kimberlitic rocks.  相似文献   

17.
18.
Permian coals of the southern hemisphere are generally considered to contain lower concentrations of sulfides, halogens, and trace elements when compared to northern hemisphere Carboniferous coals. Few studies have considered the trace element content in South African coals, and little or no work has been published for Highveld coals. Of the nineteen coal fields in South Africa, the Highveld coal field is one of the nine currently producing, and is second largest in terms of production. Five run of mine samples and a high ash middlings product from the Number 4 Lower seam were analyzed, totaling six sample sets. Fourteen trace elements (As, Cd, Co, Cr, Cu, Hg, Mn, Mo, Ni, Pb, Sb, Se, V, and Zn) were selected for this study based on the global perception that these elements may be hazardous to human health and/or the environment when they are released during coal utilization. Several sample preparation techniques were tested using certified reference materials (SARMs 18, 19 and 20) to determine the most repeatable technique for these coals. The samples were analyzed by ICP-AES and CVAA (Hg only). Microwave digestion proved to be generally unreliable despite the utilization of several different methods. A slurry direct injection method into the ICP-AES provided good correlations with the reference material, but requires further development to enhance the confidence level in this relatively unexplored technique. Samples prepared based on three ASTM standards for the determination of trace elements in coal provided repeatable results in most instances, and were the preparation methods utilized for the Highveld coals.The trace element values determined for the Highveld coals are generally in good agreement with values available in literature for South African coals, with the exception of Hg, Mn and Cr. Hg values reported here are lower, Cr and Mn higher. Results generally agree well with analyses on the same samples conducted by the United States Geological Survey. When considering the global ranges for trace elements, the Highveld range values are within Swaine's range boundaries with the exception of Cr. Compared to the cited global average values for the fourteen trace elements determined, the values obtained for the Highveld coals generally fall below or well below these average values, with the exception of Cr and Mn. Concentrations of Cd and Cu are lower compared to global average values, and As, Mo, Pb, Se, Sb, and Zn can be considered low to very low. Arsenic is ten times lower compared to typical USA values. Concentrations of Co and Ni are similar to global averages, with V and Hg being very slightly higher. The middlings samples reported higher concentrations of most elements, related to the higher ash content of these samples. Of interest, the chalcophile elements determined are all depleted in the Highveld coals compared to global averages, and the siderophile elements are enriched or comparable to global averages.Risk-based health studies in the USA on coals with similar or higher Hg and significantly higher As contents have not reported negative health effects, and therefore it could be assumed that the mobilization of these trace elements from the five Highveld coals are unlikely to cause human health problems. Work is ongoing to determine the modes of occurrence of these HAPs and to address the partitioning behaviors and speciation states of these elements during coal utilization.  相似文献   

19.
The possible existence of meteoritic spherules was investigated among several silicate spherules separated from oceanic sediments and analyzed by means of INAA (instrumental neutron activation analysis).A 0.72 mg glassy spherule was found to have uniform enrichment of 4 ~ 5 for the refractory REE (rare earth elements) and Sc with substantial depletion of Ce relative to chondritic abundances. This implies that this spherule is meteoritic in origin and that the enrichment of refractory elements was established by high temperature heating in a high O/H environment, possibly at the time of entering the Earth's atmosphere.The other three analyzed spherules showed major and trace element abundances that are consistent with an origin in the oceanic environment.  相似文献   

20.
More than 130 samples of Tertiary phonolitic, trachytic and trachyandesitic rocks, representing evolved members of strongly and weakly alkaline volcanic rock series of the Ohre (Eger) Rift in the Bohemian Massif, Czech Republic, were analysed by instrumental neutron and photon activation analysis (INAA and IPAA, respectively). Forty-two major and trace elements were determined to explain the origin of such evolved rocks. Specific features of INAA and IPAA of the silicic, highly alkaline rocks are discussed, and results for selected samples are given.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号