首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ilmenite (FeTiO3) is a common accessory mineral and has been used as a powerful petrogenetic indicator in many geological settings. Elemental fractionation and matrix effects in ilmenite (CRN63E‐K) and silicate glass (NIST SRM 610) were investigated using 193 nm ArF excimer nanosecond (ns) laser and 257 nm femtosecond (fs) laser ablation systems coupled to an inductively coupled plasma‐mass spectrometer. The concentration‐normalised 57Fe and 49Ti responses in ilmenite were higher than those in NIST SRM 610 by a factor of 1.8 using fs‐LA. Compared with the 193 nm excimer laser, smaller elemental fractionation was observed using the 257 nm fs laser. When using 193 nm excimer laser ablation, the selected range of the laser energy density had a significant effect on the elemental fractionation in ilmenite. Scanning electron microscopy images of ablation craters and the morphologies of the deposited aerosol materials showed more melting effects and an enlarged particle deposition area around the ablation site of the ns‐LA‐generated crater when compared with those using fs‐LA. The ejected material around the ns crater predominantly consisted of large droplets of resolidified molten material; however, the ejected material around the fs crater consisted of agglomerates of fine particles with ‘rough' shapes. These observations are a result of the different ablation mechanisms for ns‐ and fs‐LAs. Non‐matrix‐matched calibration was applied for the analysis of ilmenite samples using NIST SRM 610 as a reference material for both 193 nm excimer LA‐ICP‐MS and fs‐LA‐ICP‐MS. Similar analytical results for most elements in ilmenite samples were obtained using both 193 nm excimer LA‐ICP‐MS at a high laser energy density of 12.7 J cm?2 and fs‐LA‐ICP‐MS.  相似文献   

2.
LA‐ICP‐MS is one of the most promising techniques for in situ analysis of geological and environmental samples. However, there are some limitations with respect to measurement accuracy, in particular for volatile and siderophile/chalcophile elements, when using non‐matrix‐matched calibration. We therefore investigated matrix‐related effects with a new 200 nm femtosecond (fs) laser ablation system (NWRFemto200) using reference materials with different matrices and spot sizes from 10 to 55 μm. We also performed similar experiments with two nanosecond (ns) lasers, a 193 nm excimer (ESI NWR 193) and a 213 nm Nd:YAG (NWR UP‐213) laser. The ion intensity of the 200 nm fs laser ablation was much lower than that of the 213 nm Nd:YAG laser, because the ablation rate was a factor of about 30 lower. Our experiments did not show significant matrix dependency with the 200 nm fs laser. Therefore, a non‐matrix‐matched calibration for the multi‐element analysis of quite different matrices could be performed. This is demonstrated with analytical results from twenty‐two international synthetic silicate glass, geological glass, mineral, phosphate and carbonate reference materials. Calibration was performed with the certified NIST SRM 610 glass, exclusively. Within overall analytical uncertainties, the 200 nm fs LA‐ICP‐MS data agreed with available reference values.  相似文献   

3.
Previous laser ablation‐ICP‐MS bulk analyses have been confined to volcanic glasses and glass disks or powder pellets similar to those used for XRF analysis. This study proposes a method to determine twenty trace elements (fourteen rare earth elements, Sc, Y, Zr, Nb, Hf and Ta) by LA‐ICP‐MS directly from polished thick sections and rock slabs of six fine‐grained crystalline and aphanitic rocks (five volcanic rocks and one pelitic tillite). Laser scanning of eight to ten 20 mm long linear tracks using a spot size of 160 μm, with a total ablated area of 26–32 mm2, was performed. Quantification was carried out by (a) internal standardisation using Si and (b) without applying internal standardisation. In the latter method, external determination of one element in conventional LA‐ICP‐MS quantification is no longer needed. Although the fine‐grained rocks studied contained variable amounts of volatiles (up to 4%), this method gave results that agree within 10% relative with those obtained by internal standardisation using Si. Two USGS basalt glass reference materials (BCR‐2G and BHVO‐2G) were used for external calibration. The results and the associated trace element patterns and ratios of elemental pairs obtained from both methods of quantification showed good agreement with the results from solution nebulisation ICP‐MS within 20% (mostly within 10%) relative. Fine‐grained rocks are common and include volcanic, sedimentary and low‐grade metamorphic rocks (e.g., basalt, andesite, rhyolite, shale, mudstone, tillite, loess, pelite and slate) and their trace element contents and associated ratios are important geochemical tracers in studies focusing on the composition and evolution of the crust and mantle. Our method provides a simple and quantitative way to determine trace elements in fine‐grained rocks even with those displaying complex textures.  相似文献   

4.
Compared with solution ICP‐MS, LA‐ICP‐MS studies have thus far reported comparatively few external reference data for accuracy estimates of experiments. This is largely the result of a paucity of available reference materials of natural composition. Here, we report an evaluation of natural glass (obsidian) as an inexpensive and widely available external reference material. The homogeneity of over forty elements in six different obsidian samples was assessed by LA‐ICP‐MS. Accuracy was tested with two obsidian samples that were fully characterised by electron probe microanalysis and solution ICP‐MS. Laser ablation experiments were performed with a variety of ablation parameters (fluence, spot sizes, ablation repetition rates) and calibration approaches (natural vs. synthetic reference materials, and different internal standard elements) to determine the best practice for obsidian analysis. Furthermore, the samples were analysed using two different laser wavelengths (193 nm and 213 nm) to compare the effect of potential ablation‐related phenomena (e.g., fractionation). Our data indicate that ablation with fluences larger than 6 J cm?2 and repetition rates of 5 or 10 Hz resulted in the most accurate results. Furthermore, synthetic NIST SRM 611 and 612 glasses worked better as reference materials compared with lower SiO2 content reference materials (e.g., BHVO‐2G or GOR128‐G). The very similar SiO2 content of the NIST SRM glasses and obsidian (i.e., matrix and compositional match) seems to be the first‐order control on the ablation behaviour and, hence, the accuracy of the data. The use of different internal standard elements for the quantification of the obsidian data showed that Si and Na yielded accurate results for most elements. Nevertheless, for the analysis of samples with high SiO2 concentrations, it is recommended to use Si as the internal standard because it can be more precisely determined by electron probe microanalysis. At the scale of typical LA analyses, the six obsidian samples proved to be surprisingly homogenous. Analyses with a spot size of 80 μm resulted in relative standard deviations (% RSD) better than 8% for all but the most depleted elements (e.g., Sc, V, Ni, Cr, Cu, Cd) in these evolved glasses. The combined characteristics render obsidian a suitable, inexpensive and widely available, external quality‐control material in LA‐ICP‐MS analysis for many applications. Moreover, obsidian glass is suited for tuning purposes, and well‐characterised obsidian could even be used as a matrix‐matched reference material for a considerable number of elements in studies of samples with high SiO2 contents.  相似文献   

5.
Lead isotope ratio data were obtained with good precision and accuracy using a 266 nm femtosecond laser ablation (fLA) system connected to a multi‐collector ICP‐MS (MC‐ICP‐MS) and through careful control of analytical procedures. The mass fractionation coefficient induced by 266 nm femtosecond laser ablation was approximately 28% lower than that by 193 nm excimer laser ablation (eLA) with helium carrier gas. The exponential law correction method for Tl normalisation with optimum adjusted Tl ratio was utilised to obtain Pb isotopic data with good precision and accuracy. The Pb isotopic ratios of the glass reference materials NIST SRM 610, 612, 614; USGS BHVO‐2G, BCR‐2G, GSD‐1G, BIR‐1G; and MPI‐DING GOR132‐G, KL2‐G, T1‐G, StHs60/80‐G, ATHO‐G and ML3B‐G were determined using fLA‐MC‐ICP‐MS. The measured Pb isotopic ratios were in good agreement with the reference or published values within 2s measurement uncertainties. We also present the first high‐precision Pb isotopic data for GSE‐1G, GSC‐1G, GSA‐1G and CGSG‐1, CGSG‐2, CGSG‐4 and CGSG‐5 glass reference materials obtained using the femtosecond laser ablation MC‐ICP‐MS analysis technique.  相似文献   

6.
Here, we present an approach to laser ablation ICP‐MS mapping of multi‐phase assemblages that permits the use of different internal standard elements, concentration values and reference materials for each mineral. In this way, we obtain not only broad pictures of elemental distributions within samples but can also extract high accuracy concentration data for any user‐selected region. This is accomplished by assigning regions of an image to corresponding mineral phases on a pixel‐by‐pixel basis. In this way, accurate trace element concentrations can be determined for each mineral phase, despite potential variations in their ablation characteristics. We present an example where elemental maps are constructed from ablation of a gabbroic sample that includes the phases apatite, amphibole and plagioclase. This work represents an important first step towards development of a method to produce highly accurate LA‐ICP‐MS elemental maps of multi‐phase samples.  相似文献   

7.
We report homogeneity tests on large natural apatite crystals to evaluate their potential as U reference materials for apatite fission‐track (AFT) thermochronology by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS). The homogeneity tests include the measurements of major element concentrations by electron probe microanalysis (EPMA), whereas for U concentration, isotope dilution (ID) ICP‐MS and laser ablation (LA) ICP‐MS were employed. Two apatite crystals are potential reference materials for LA‐ICP‐MS analysis: a 1 cm3 fraction of a Durango crystal (7.5 μg g?1 U) and a 1 cm3 Mud Tank crystal (6.9 μg g?1 U). The relative standard deviation (1 RSD) of the U concentration determined by ID‐ICP‐MS of both apatite crystals was ≤ 1.5%, whereas 1 RSD for the LA‐ICP‐MS results was better than 4%, providing sufficient homogeneity for fission‐track dating. The results on the U homogeneity for two different apatite samples are an important step towards establishing in situ dating routines for AFT analysis by LA‐ICP‐MS.  相似文献   

8.
An in situ, medium‐resolution LA‐ICP‐MS method was developed to measure the abundances of the first‐row transition metals, Ga and Ge in a suite of geological materials, namely the MPI‐DING reference glasses. The analytical protocol established here hinged on maximising the ablation rate of the ultraviolet (UV) laser system and the sensitivity of the ICP‐MS, as well minimising the production of diatomic oxides and argides, which serve as the dominant sources of isobaric interferences. Non‐spectral matrix effects were accounted for by using multiple external calibrators, including NIST SRM 610 and the USGS basaltic glasses BHVO‐2G, BIR‐1G and BCR‐2G, and utilising 43Ca as an internal standard. Analyses of the MPI‐DING reference glasses, which represent geological matrices ranging from basaltic to rhyolitic in composition, included measurements of concentrations as low as < 100 μg g?1 and as high as > 104 μg g?1. The new data reported here were found to statistically correlate with the ‘preferred’ reference values for these materials at the 95% confidence level, though with significantly better precision, typically on the order of ≤ 3% (2sm). This analytical method may be extended to any matrix‐matched geological sample, particularly oceanic basalts, silicate minerals and meteoritic materials.  相似文献   

9.
In this study, a technique for high precision in situ Fe and Mg isotope determinations by femtosecond‐laser ablation‐multi collector‐ICP‐MS (fs‐LA‐MC‐ICP‐MS) was developed. This technique was employed to determine reference values for a series of common reference glasses that may be used for external standardisation of in situ Fe and Mg isotope determinations in silicates. The analysed glasses are part of the MPI‐DING and United States Geological Survey (USGS) reference glass series, consisting of basaltic (BIR‐1G, BCR‐2G, BHVO‐2G, KL2‐G, ML3B‐G) and komatiitic (GOR128‐G and GOR132‐G) compositions. Their Fe and Mg isotope compositions were determined by in situ fs‐LA‐MC‐ICP‐MS and by conventional solution nebulisation multi‐collector ICP‐MS. We determined δ56Fe values for these glasses ranging between ‐0.04‰ and 0.10‰ (relative to IRMM‐014) and δ26Mg values ranging between ‐0.40‰ and ‐0.15‰ (relative to DSM‐3). Our fs‐LA‐MC‐ICP‐MS results for both Fe and Mg isotope compositions agreed with solution nebulisation analyses within analytical uncertainties. Furthermore, the results of three USGS reference glasses (BIR‐1G, BHVO‐2G and BCR‐2G) agreed with previous results for powdered and dissolved aliquots of the same reference materials. Measurement reproducibilities of the in situ determinations of δ56Fe and δ26Mg values were usually better than 0.12‰ and 0.13‰ (2s), respectively. We further demonstrate that our technique is a suitable tool to resolve isotopic zoning in chemically‐zoned olivine crystals. It may be used for a variety of different applications on isotopically‐zoned minerals, e.g., in magmatic or metamorphic rocks or meteorites, to unravel their formation or cooling rates.  相似文献   

10.
Laser ablation inductively coupled plasma mass spectrometry (LA‐ICP‐MS) is a high spatial resolution analytical method which has been applied to the analysis of silicic tephras. With current instrumentation, around 30 trace elements can be determined from single glass shards as small as ~ 40 µm, separated from tephra deposits. As a result of element fractionation during the ablation process using a 266 nm laser, a relatively complex calibration strategy is required. Nonetheless, such a strategy gives analyses which are accurate (typically within ±5%) and have an analytical precision which varies from ~ ±2% at 100 ppm, to ~ ±15% at 1 ppm. Detection limits for elements used in correlation and discrimination studies are well below 1 ppm. Examples of the application of trace element analysis by LA‐ICP‐MS in tephra studies are presented from the USA, New Zealand and the Mediterranean. Improvements in instrumental sensitivity in recent years have the potential to lower detection limits and improve analytical precision, thus allowing the analysis of smaller glass shards from more distal tephras. Laser systems operating at shorter wavelengths (e.g. 193 nm) are now more widely available, and produce a much more controllable ablation in glasses than 266 nm lasers. Crater sizes of <10 µm are easily achieved, and at 193 nm many of the elemental fractionation issues which mar longer wavelengths are overcome. By coupling a short wavelength laser to a modern ICP‐MS it should be possible to determine the trace element composition of glass shards as small as 20 µm and, providing sample preparation issues can be overcome, the determination of the more abundant trace elements in glass shards as small as 10 µm is within instrumental capabilities. This will make it possible to chemically fingerprint tephra deposits which are far from their sources, and will greatly extend the range over which geochemical correlation of tephras can be undertaken. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
An efficient, clean procedure for the measurement of element mass fractions in bulk rock nanoparticulate pressed powder pellets (PPPs) by 193 nm laser ablation ICP‐MS is presented. Samples were pulverised by wet milling and pelletised with microcrystalline cellulose as a binder, allowing non‐cohesive materials such as quartz or ceramics to be processed. The LA‐ICP‐MS PPP analytical procedure was optimised and evaluated using six different geological reference materials (JP‐1, UB‐N, BCR‐2, GSP‐2, OKUM and MUH‐1), with rigorous procedural blank quantification employing synthetic quartz. Measurement trueness of the procedure was equivalent to that achieved by solution ICP‐MS and LA‐ICP‐MS analysis of glass. The measurement repeatability was as low as 0.5–2% (1s,= 6) and, accordingly, PPP homogeneity could be demonstrated. Calibration based on the reference glasses NIST SRM 610, NIST SRM 612, BCR‐2G and GSD‐1G revealed matrix effects for glass and PPP measurement with NIST SRM 61×; using basalt glasses eliminated this problem. Most significantly, trace elements not commonly measured (flux elements Li, B; chalcophile elements As, Sb, Tl, In, Bi) could be quantified. The PPP‐LA‐ICP‐MS method overcomes common problems and limitations in analytical geochemistry and thus represents an efficient and accurate alternative for bulk rock analysis.  相似文献   

12.
LA‐ICP‐MS is increasingly applied to obtain quantitative multi‐element data with minimal sample preparation, usually achieved by calibration using reference materials (RMs). However, some ubiquitous RMs, for example the NIST SRM 61× series glasses, suffer from reported value uncertainties for certain elements. Moreover, no long‐term data set of analyses conducted over a range of ablation and tuning conditions exists. Thus, there has been little rigorous examination of the extent to which offsets between measured and reported values are the result of error in these values rather than analytically induced fractionation. We present new software (‘LA‐MINE’), capable of extracting LA‐ICP‐MS data with no user input, and apply this to our system, yielding over 5 years of data (~ 5700 analyses of ten glass and carbonate RMs). We examine the relative importance of systematic analytical bias and possible error in reported values through a mass‐specific breakdown of fourteen of the most commonly determined elements. Furthermore, these data, obtained under a wide range of different ablation conditions, enable specific recommendations of how data quality may be improved, for example the role of diatomic gas, the effect of differential inter‐glass fractionation factors and choice of transport tubing material. Finally, these data demonstrate that the two‐volume Laurin ablation cell is characterised by no discernible spatial heterogeneity in measured trace element ratios.  相似文献   

13.
Here, we present determinations of thallium (Tl) concentrations in the USGS reference materials BIR‐1G, BHVO‐2G and BCR‐2G measured by solution ICP‐MS. The Tl content in these three glasses spans a range of about 2–230 ng g?1, which is similar to the values published for the respective powder materials. The determined range of Tl concentrations in these three glass reference materials makes them ideal for investigating Tl concentrations in basaltic and andesitic volcanic glasses. We also performed a series of laser ablation ICP‐MS measurements on the three samples, which show that this technique is able to determine Tl concentrations in glass samples with concentrations as low as 2 ng g?1.  相似文献   

14.
Research in 2006 and 2007 dealing with laser ablation‐(multicollector)‐inductively coupled plasma‐mass spectrometry, LA‐(MC)‐ICP‐MS, involved studies concerned with optimising the technique itself, as well as applying the method to a variety of problems in the Earth sciences. The causes of elemental and isotopic fractionation produced during laser ablation continues to be of considerable interest, with evidence mounting that processes occurring both at the ablation site and in the argon plasma of the ICP are culpable. There is growing excitement in the use of femtosecond lasers for LA‐(MC)‐ICP‐MS, with the hope that they reduce or eliminate melting and non‐congruent volatilisation at the ablation site and thus approach stoichiometric sampling. Ablation chamber design emerged as a serious concern, particularly with respect to achieving the rapid washout needed for fine‐scale compositional mapping of geological objects. LA‐MC‐ICP‐MS provided data for a wide range of isotopic systems, especially hafnium, but also B, S, Mg, Cu, Fe, Sr, Nd, Pb and U. Measurement uncertainties in LA‐ICP‐MS were discussed by several researchers, and are critically reviewed here ‐ total uncertainties for trace element concentration measurements of silicates including errors on the calibration values of common reference materials are ~10% (95% confidence limits), though the precision of individual spot measurements (50 to 100 μm) is much better, ~1% RSD, using a 193 nm laser and a sector field‐ICP‐MS. LA‐ICP‐MS U‐Pb ages for zircon and other U‐rich accessory phases are claimed by most geoanalysts to have 2s uncertainties of ~0.7 and 1.3% respectively but the actual accuracy of the method is probably only as good as ~2% (2s), when uncertainties associated with laser‐induced Pb/U fractionation are included.  相似文献   

15.
Sphalerite (ZnS) is an abundant ore mineral and an important carrier of elements such as Ge, Ga and In used in high‐technology applications. In situ measurements of trace elements in natural sphalerite samples using LA‐ICP‐MS are hampered by a lack of homogenous matrix‐matched sulfide reference materials available for calibration. The preparation of the MUL‐ZnS1 calibration material containing the trace elements V, Cr, Mn, Co, Ni, Cu, Ga, Ge, As, Se, Mo, Ag, Cd, In, Sn, Sb, Tl and Pb besides Zn, Fe and S is reported. Commercially available ZnS, FeS, CdS products were used as the major components, whereas the trace elements were added by doping with single‐element ICP‐MS standard solutions and natural mineral powders. The resulting powder mixture was pressed to pellets and sintered at 400 °C for 100 h using argon as an inert gas. To confirm the homogeneity of major and trace element distributions within the MUL‐ZnS1 calibration material, measurements were performed using EPMA, solution ICP‐MS, ICP‐OES and LA‐ICP‐MS. The results show that MUL‐ZnS‐1 is an appropriate material for calibrating trace element determination in sphalerite using LA‐ICP‐MS.  相似文献   

16.
A range of independently characterised reference materials (RMs) for LA‐ICP‐MS, used for the determination of the platinum‐group elements (PGE) and Au in a sulfide matrix, were analysed and compared: 8b, PGE‐A, NiS‐3, Po727‐T1, Po724‐T and the Lombard meteorite. The newly developed RM NiS‐3 was used as the RM for the calibration of all LA‐ICP‐MS analyses and the measured concentrations of the other RMs compared against their published concentrations. This data were also used to assess the consistency of concentrations calibrated against the different RMs. It was found that Po727‐T1 and 8b produced results that were comparable, within uncertainty, for all elements. Po727‐T1 also produced consistent results with NiS‐3 for all elements. All other RMs showed differences for some elements, especially Ru in Po724‐T, and Os, Ir and Au in PGE‐A. The homogeneity of the PGE and Au in each RM was assessed, by comparing the precision of multiple LA‐ICP‐MS spot analyses with the average uncertainty of the signal. Po724‐T, Po727‐T1 and the Lombard meteorite were found to be homogeneous for all elements, but 8b, PGE‐A and NiS‐3 were heterogeneous for some elements. This is the first direct comparison between a range of independently characterised PGE and Au LA‐ICP‐MS RMs.  相似文献   

17.
Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission‐electron probe microanalysis (FE‐EPMA), laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and synchrotron micro X‐ray fluorescence spectroscopy (SR‐μ‐XRF). This study assesses the accuracy, precision and detection limits of these mostly non‐destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE‐EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA‐ICP‐MS analyses required larger gold particles (> 60 μm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA‐ICP‐MS measurements had lower detection limits, precision was lower than FE‐EPMA and SR‐μ‐XRF. The higher variability in absolute values measured by LA‐ICP‐MS, possibly due to micro‐inclusions, had to be critically assessed. Non‐destructive point analyses of gold alloys by SR‐μ‐XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE‐EPMA, but higher than those for elements measured by LA‐ICP‐MS.  相似文献   

18.
19.
A simple flux‐free fusion technique was developed to analyse major and trace element compositions of silicate rocks. The sample powders were melted in a molybdenum capsule sealed in a graphite tube to make a homogenous glass in a temperature‐controlled one‐atmosphere furnace. The glass was then measured for both major and trace element concentrations by LA‐ICP‐MS using a calibration strategy of total metal‐oxide normalisation. The optimum conditions (i.e., temperature and duration) to make homogeneous glasses were obtained by performing melting experiments using a series of USGS reference materials including BCR‐2, BIR‐1, BHVO‐2, AGV‐1, AGV‐2, RGM‐1, W‐2 and GSP‐2 with SiO2 contents from 47 to 73% m/m. Analytical results of the USGS reference materials using our method were generally consistent with the recommended values within a discrepancy of 5–10% for most elements. The routine precision of our method was generally better than 5–10% RSD. Compared with previous methods of LA‐ICP‐MS whole‐rock analyses, our flux‐free fusion method is convenient and efficient in making silicate powder into homogeneous glass. Furthermore, it limits contamination and loss of volatile elements during heating. Therefore, our new method has great potential to provide reliable and rapid determinations of major and trace element compositions for silicate rocks.  相似文献   

20.
This work presents an evaluation of various methods for in situ high‐precision Sr and Pb isotopic determination in archaeological glass (containing 100–500 μg g?1 target element) by nanosecond laser ablation multi‐collector‐inductively coupled plasma‐mass spectrometry (ns‐LA‐MC‐ICP‐MS). A set of four soda‐lime silicate glasses, Corning A–D, mimicking the composition of archaeological glass and produced by the Corning Museum of Glass (Corning, New York, USA), were investigated as candidates for matrix‐matched reference materials for use in the analysis of archaeological glass. Common geological reference materials with known isotopic compositions (USGS basalt glasses BHVO‐2G, GSE‐1G and NKT‐1G, soda‐lime silicate glass NIST SRM 610 and several archaeological glass samples with known Sr isotopic composition) were used to evaluate the ns‐LA‐MC‐ICP‐MS analytical procedures. When available, ns‐LA‐MC‐ICP‐MS results for the Corning glasses are reported. These were found to be in good agreement with results obtained via pneumatic nebulisation (pn) MC‐ICP‐MS after digestion of the glass matrix and target element isolation. The presence of potential spectral interference from doubly charged rare earth element (REE) ions affecting Sr isotopic determination was investigated by admixing Er and Yb aerosols by means of pneumatic nebulisation into the gas flow from the laser ablation system. It was shown that doubly charged REE ions affect the Sr isotope ratios, but that this could be circumvented by operating the instrument at higher mass resolution. Multiple strategies to correct for instrumental mass discrimination in ns‐LA‐MC‐ICP‐MS and the effects of relevant interferences were evaluated. Application of common glass reference materials with basaltic matrices for correction of ns‐LA‐MC‐ICP‐MS isotope data of archaeological glasses results in inaccurate Pb isotope ratios, rendering application of matrix‐matched reference materials indispensable. Correction for instrumental mass discrimination using the exponential law, with the application of Tl as an internal isotopic standard element introduced by pneumatic nebulisation and Corning D as bracketing isotopic calibrator, provided the most accurate results for Pb isotope ratio measurements in archaeological glass. Mass bias correction relying on the power law, combined with intra‐element internal correction, assuming a constant 88Sr/86Sr ratio, yielded the most accurate results for 87Sr/86Sr determination in archaeological glasses  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号