首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The recharge and origin of groundwater and its residence time were studied using environmental isotopic measurements in samples from the Heihe River Basin, China. δ18O and δD values of both river water and groundwater were within the same ranges as those found in the alluvial fan zone, and lay slightly above the local meteoric water line (δD=6.87δ18O+3.54). This finding indicated that mountain rivers substantially and rapidly contribute to the water resources in the southern and northern sub-basins. δ18O and δD values of groundwater in the unconfined aquifers of these sub-basins were close to each other. There was evidence of enrichment of heavy isotopes in groundwater due to evaporation. The most pronounced increase in the δ18O value occurred in agricultural areas, reflecting the admixture of irrigation return flow. Tritium results in groundwater samples from the unconfined aquifers gave evidence for ongoing recharge, with mean residence times of: less than 36 years in the alluvial fan zone; about 12–16 years in agricultural areas; and about 26 years in the Ejina oasis. In contrast, groundwater in the confined aquifers had 14C ages between 0 and 10 ka BP.  相似文献   

2.
The groundwater flow system and the flow velocity in the alluvial fan plain of the Hutuo River, China, have been studied, with an emphasis on relating geochemical characteristics and isotopes factors. Seven stretches of one river, six springs and 31 wells, with depths ranging from 0 m (river waters) to 150 m, were surveyed. The groundwater has a vertical two-layer structure with a boundary at about 80–100 m depth, yielding an upper and a lower groundwater layer. The δ18O and δD values range from ?10.56 to ?7.05‰ and ?81.83 to ?59‰, respectively. The groundwater has been recharged by precipitation, and has not been subjected to significant evaporation during infiltration into the aquifer in the upper layer. Using a tritium model, the groundwater flow in the alluvial fan plain showed horizontal flow velocity to be greater than vertical velocity. Groundwater in the upper layer is characterized by Ca–HCO3 type. From the spatial distribution characteristics of the stable isotope and chemical composition of the groundwater, agricultural irrigation was considered to have an influence on the aquifer by causing excessive groundwater abstraction and irrigation return.  相似文献   

3.
为了查明曹妃甸浅层地下水水化学及咸化成因,采集研究区河水、地下淡水、微咸水、咸水、卤水、雨水和海水等不同类型水样,对其水化学组成、离子比、Piper三线图、吉布斯图、氢氧同位素组成及14C测年结果进行了分析。结果表明:(1)曹妃甸浅层地下水包括全新世沉积层潜水和晚更新世沉积层微承压水,且非原始封存在地层中而是形成于全新世中晚期。(2)地下潜水向海方向分布有淡水、微咸水、咸水水质类型,微承压水以咸水和卤水为主要水质类型;近冲洪积扇前缘水化学特征主要受岩石风化作用控制,围填海区及河口处水化学特征受海水混合作用控制,滨海平原区水化学特征主要受蒸发/结晶作用控制。(3)曹妃甸浅层地下水咸化过程主要是晚更新世以来海侵海退时期形成海洋蒸发盐经大气降水和河水多期溶滤所致,其盐分来源于海水蒸发盐,河口及围填海区地下潜水盐分主要来源于现代海水入侵。  相似文献   

4.
Environmental tracers (such as major ions, stable and radiogenic isotopes, and heat) monitored in natural waters provide valuable information for understanding the processes of river–groundwater interactions in arid areas. An integrated framework is presented for interpreting multi-tracer data (major ions, stable isotopes (2H, 18O), the radioactive isotope 222Rn, and heat) for delineating the river–groundwater interactions in Nalenggele River basin, northwest China. Qualitative and quantitative analyses were undertaken to estimate the bidirectional water exchange associated with small-scale interactions between groundwater and surface water. Along the river stretch, groundwater and river water exchange readily. From the high mountain zone to the alluvial fan, groundwater discharge to the river is detected by tracer methods and end-member mixing models, but the river has also been identified as a losing river using discharge measurements, i.e. discharge is bidirectional. On the delta-front of the alluvial fan and in the alluvial plain, in the downstream area, the characteristics of total dissolved solids values, 222Rn concentrations and δ18O values in the surface water, and patterns derived from a heat-tracing method, indicate that groundwater discharges into the river. With the environmental tracers, the processes of river–groundwater interaction have been identified in detail for better understanding of overall hydrogeological processes and of the impacts on water allocation policies.  相似文献   

5.
黄河三角洲地区地下淡水(微咸水)的形成与演化   总被引:8,自引:0,他引:8  
黄河三角洲地区地下淡水(微咸水)资源贫乏,咸水广布。南部冲洪积平原受第二次海侵层位的影响形成大面积咸水,后被逐渐淡化。近年来由于开采量加大,又使北部咸水南侵。海积冲积平原随着黄河河道的变迁,仅在黄河现行河道两侧和充水的黄河故道带分布有淡水(微咸水)。近代,现代黄河三角洲古河道带和决口扇淡水体已被咸化。  相似文献   

6.
Huang  Xiangui  Ping  Jianhua  Leng  Wei  Yu  Yan  Zhang  Min  Zhu  Yaqiang 《Hydrogeology Journal》2021,29(6):2149-2170

Studies on groundwater recharge are essential for sustainable exploitation of groundwater resources, especially in areas of extensive groundwater exploitation such as the Anyanghe River alluvial fan (ARAF) in the North China Plain (NCP). However, the recharge sources and processes and the contribution of each recharge flow component remain unclear. This study used hydrochemistry, stable isotopes, and tritium to investigate sources and underlying processes of groundwater recharge, along with the steady flow Mixing Cell Model (MCMsf) to quantify the proportion of each source flow for the shallow confined groundwater system in the medial fan. The results showed that groundwater mainly originates from precipitation occurring on the eastern Taihang Mountain area with average elevation estimated at 700–1,000 m above sea level during the East Asia summer monsoon period since 1952. Recharge mechanisms are: (1) river water seepage for the unconfined aquifers of the proximal and medial fan; (2) lateral flow for the confined aquifers of the medial and distal fan; and (3) precipitation infiltration for the phreatic water system. The MCMsf simulation showed that the shallow confined groundwater system in the central zone of the medial fan mainly recharged by the lateral flow from the proximal fan, a constant and considerable recharge flow from the southwestern and southern hills, and river water seepage in the medial fan; the lateral recharge flow from the Zhanghe alluvial aquifer was insignificant by comparison. The results of this study can act as a valuable reference for sustainable groundwater management in the ARAF.

  相似文献   

7.
The Quaternary coastal plain aquifer down gradient of the Wadi Watir catchment is the main source of potable groundwater in the arid region of south Sinai, Egypt. The scarcity of rainfall over the last decade, combined with high groundwater pumping rates, have resulted in water-quality degradation in the main well field and in wells along the coast. Understanding the sources of groundwater salinization and amount of average annual recharge is critical for developing sustainable groundwater management strategies for the long-term prevention of groundwater quality deterioration. A combination of geochemistry, conservative ions (Cl and Br), and isotopic tracers (87/86Sr, δ81Br, δ37Cl), in conjunction with groundwater modeling, is an effective method to assess and manage groundwater resources in the Wadi Watir delta aquifers. High groundwater salinity, including high Cl and Br concentrations, is recorded inland in the deep drilled wells located in the main well field and in wells along the coast. The range of Cl/Br ratios for shallow and deep groundwaters in the delta (∼50–97) fall between the end member values of the recharge water that comes from the up gradient watershed, and evaporated seawater of marine origin, which is significantly different than the ratio in modern seawater (228). The 87/86Sr and δ81Br isotopic values were higher in the recharge water (0.70,723 < 87/86Sr < 0.70,894, +0.94 < δ81Br < +1.28‰), and lower in the deep groundwater (0.70,698 < 87/86Sr < 0.70,705, +0.22‰ < δ81Br < +0.41‰). The δ37Cl isotopic values were lower in the recharge water (−0.48 < δ37Cl < −0.06‰) and higher in the deep groundwater (−0.01 < δ37Cl < +0.22‰). The isotopic values of strontium, chloride, and bromide in groundwater from the Wadi Watir delta aquifers indicate that the main groundwater recharge source comes from the up gradient catchment along the main stream channel entering the delta. The solute-weighted mass balance mixing models show that groundwater in the main well field contains 4–10% deep saline groundwater, and groundwater in some wells along the coast contain 2–6% seawater and 18–29% deep saline groundwater.A three-dimensional, variable-density, flow-and-transport SEAWAT model was developed using groundwater isotopes (87Sr/86Sr, δ37Cl and δ81Br) and calibrated using historical records of groundwater level and salinity. δ18O was used to normalize the evaporative effect on shallow groundwater salinity for model calibration. The model shows how groundwater salinity and hydrologic data can be used in SEAWAT to understand recharge mechanisms, estimate groundwater recharge rates, and simulate the upwelling of deep saline groundwater and seawater intrusion. The model indicates that most of the groundwater recharge occurs near the outlet of the main channel. Average annual recharge to delta alluvial aquifers for 1982 to 2009 is estimated to be 2.16 × 106 m3/yr. The main factors that control groundwater salinity are overpumping and recharge availability.  相似文献   

8.
黑河干流浅层地下水与地表水相互转化的水化学特征   总被引:14,自引:0,他引:14  
通过分析黑河干流地表水与地下水的水化学特征,识别沿黑河干流不同地带地下水与地表水的相互转化关系.研究结果表明:(1)在祁连山区,地下水与地表水的转化以地下水向河流排泄为主.(2)南部盆地,在山前戈壁带,出山河水入渗转化为地下水;溢出带地下水以泉的形式转化为地表水;进入细土平原后,汛期河水补给地下水,非汛期地下水补给河水;在农灌区引河水通过田间入渗补给地下水.(3)北部盆地,在金塔灌区,地下水主要接受引水灌溉入渗补给;在金塔灌区到额济纳旗,河流入渗转化为地下水.  相似文献   

9.
Concentration and isotope ratios (δ34SSO4 and δ18OSO4) of dissolved sulfate of groundwater were analyzed in a very large anaerobic aquifer system under the Lower Central Plain (LCP) (25,000 km2) in Thailand. Groundwater samples were collected in two different kinds of aquifers; type 1 with a saline water contribution and type 2 lateritic aquifers with no saline water contribution. Two different isotopic compositional trends were observed: in type 1 aquifers sulfate isotope ratios range from low values (+2.2‰ for δ34SSO4 and +8.0‰ for δ18OSO4) to high values (+49.9‰ for δ34SSO4 and +17.9‰ for δ18OSO4); in type 2 aquifers sulfate isotope ratios range from low values (−0.1‰ for δ34SSO4 and +12.2‰ for δ18OSO4) to high δ18OSO4 ratios (+18.4‰) but with low δ34SSO4 ratios (<+12.9‰). Isotopic comparison with possible source materials and theoretical geochemical models suggests that the sulfate isotope variation for type 1 aquifer groundwater can be explained by two main processes. One is the contribution of remnant seawater, which has experienced dissimilatory sulfate reduction in the marine clay, into recharge water of freshwater origin. This process accounts for the high salinity groundwater. The other process, explaining for the modest salinity groundwater, is the bacterial sulfate reduction of the mixture water between high salinity water and fresh groundwater. Isotopic variation of type 2 aquifer groundwater may also be explained by bacterial sulfate reduction, with slower reduction rate than that of the groundwater with saline water effect. The origin of groundwater sulfate with low δ34SSO4 but high δ18OSO4 is recognized as an important topic to be examined in a future investigation.  相似文献   

10.
High As contents in groundwater were found in two neighboring catchments – the Chianan plain and the southern Choushui river alluvial fan in Taiwan. The groundwater quality, the redox potential and the As distribution of the Chianan plain were characterized using factor analysis, redox zoning and a geochemical program. The results were compared with those of the southern Choushui river alluvial fan. Possible As release mechanisms are also elucidated. Factors 1 and 2 of the groundwater in the Chianan plain – the salinization factor and the As enrichment factor – are similar to those in the southern Choushui river alluvial fan. However, the spatial distribution of reductive tendency in the Chianan plain is different to that in the Choushui river alluvial fan, and yields spatially distinct hydrogeochemical environments in these two neighboring areas. The reduction potential in the Chianan plain is stronger than that in the Choushui river alluvial fan. The difference between the reduction potentials in these two vicinal areas influences the concentrations of As in groundwater. The reductive dissolution of As-rich Fe oxyhydroxide is suggested to be the major mechanism for release of As to the groundwater in the Chianan plain and the Choushui river alluvial fan of Taiwan.  相似文献   

11.
This paper investigated the sources and behaviors of sulfate in groundwater of the western North China Plain using sulfur and oxygen isotopic ratios. The groundwaters can be categorized into karst groundwater (KGW), coal mine drainage (CMD) and pore water (subsurface saturated water in interstices of unconsolidated sediment). Pore water in alluvial plain sediments could be further classified into unconfined groundwater (UGW) with depth of less than 30 m and confined groundwater (CGW) with depth of more than 60 m. The isotopic compositions of KGW varied from 9.3‰ to 11.3‰ for δ34SSO4 with the median value of 10.3‰ (n = 4) and 7.9‰ to 15.6‰ for δ18OSO4 with the median value of 14.3‰ (n = 4) respectively, indicating gypsum dissolution in karst aquifers. δ34SSO4 and δ18OSO4 values of sulfate in CMD ranged from 10.8‰ to 12.4‰ and 4.8‰ to 8.7‰ respectively. On the basis of groundwater flow path and geomorphological setting, the pore water samples were divided as three groups: (1) alluvial–proluvial fan (II1) group with high sulfate concentration (median values of 2.37 mM and 1.95 mM for UGW and CGW, respectively) and positive δ34SSO4 and δ18OSO4 values (median values of 8.8‰ and 6.9‰ for UGW, 12.0‰ and 8.0‰ for CGW); (2) proluvial slope (II2) group with low sulfate concentration (median values of 1.56 mM and 0.84 mM for UGW and CGW, respectively) and similar δ34SSO4 and δ18OSO4 values (median values of 9.0‰ and 7.4‰ for UGW, 10.2‰ and 7.7‰ for CGW); and (3) low-lying zone (II3) group with moderate sulfate concentration (median values of 2.13 mM and 1.17 mM for UGW and CGW, respectively) and more positive δ34SSO4 and δ18OSO4 values (median values of 10.7‰ and 7.7‰ for UGW, 20.1‰ and 8.8‰ for CGW). In the present study, three major sources of sulfate could be differentiated as following: sulfate dissolved from Ordovician to Permian rocks (δ34SSO4 = 10–35‰ and δ18OSO4 = 7–20‰), soil sulfate (δ34SSO4 = 5.9‰ and δ18OSO4 = 5.8‰) and sewage water (δ34SSO4 = 10.0‰ and δ18OSO4 = 7.6‰). Kinetic fractionations of sulfur and oxygen isotopes as a result of bacterial sulfate reduction (BSR) were found to be evident in the confined aquifer in stagnant zone (II3), and enrichment factors of sulfate–sulfur and sulfate–oxygen isotopes calculated by Rayleigh equation were −12.1‰ and −4.7‰ respectively along the flow direction of groundwater at depths of 60–100 m. The results obtained in this study confirm that detailed hydrogeological settings and identification of anthropogenic sources are critical for elucidating evolution of δ34SSO4 and δ18OSO4 values along with groundwater flow path, and this work also provides a useful framework for understanding sulfur cycling in alluvial plain aquifers.  相似文献   

12.
Zhangye Basin, in arid northwestern China, has recently been repeatedly flooded by rising groundwater. Isotope signatures of sampled waters gained insight into the recharge source of the groundwater. The summer Heihe River water and most of the spring water in Zhangye and Yongchang basins plotted above the global meteoric water line (GMWL) on the δ18O-δD plot. The spring water had R/Ra ratio >1, low TDS and high tritium, which indicates origin from Qilian Mountain glacier meltwater. The groundwater of Qilian Mountains was transported to the Hexi Corridor (in which Zhangye Basin is located) through underground fault zones. Additionally, some of the groundwater in the alluvial plain, and all spring water surrounding Zhangye Basin, plotted below the GMWL on the δ18O-δD plot along an evaporation line, and had R/Ra ratio?<?1 and high TDS. It is proposed that the Tibetan rivers or lakes source the Hexi Corridor groundwater through either the NE-trending or NW-trending buried fault zones. The isotopic signatures presented as part of this study rule out the conventional viewpoint that groundwater of the Zhangye Basin was recharged by local precipitation and infiltration of Heihe River water on the alluvial plain.  相似文献   

13.
An investigation using environmental isotopes (δ18O and δD) was conducted to gain insight into the hydrological processes of the Ganga Alluvial Plain, northern India. River-water, shallow-groundwater and lake-water samples from the Gomati River Basin were analyzed. During the winter season, the δ18O and δD compositions of the Gomati River water ranged from ?1.67 to ?7.62 ‰ and ?25.08 to ?61.50 ‰, respectively. Deuterium excess values in the river water (+0.3 to ?13 ‰) and the lake water (?20 ‰) indicate the significance of evaporation processes. Monthly variation of δ18O and δD values of the Gomati River water and the shallow groundwater follows a similar trend, with isotope-depleted peaks for δ18O and δD synchronized during the monsoon season. The isotopically depleted peak values of the river water (δ18O?=??8.30 ‰ and δD?=??57.10 ‰) can be used as a proxy record for the isotopic signature of the monsoon precipitation in the Ganga Alluvial Plain.  相似文献   

14.
《Applied Geochemistry》2006,21(4):643-655
The groundwater B concentration in the alluvial aquifer of the upper Cecina River basin in Tuscany, Italy, often exceeds the limit of 1 mg L−1 set by the European Union for drinking water. On the basis of hydrogeological and geochemical observations, the main source of the B contamination of groundwater has been attributed to past releases into streams of exhausted, B-rich geothermal waters and/or mud derived from boric acid manufacturing in Larderello. The releases were discontinued 25–30 years ago.This study confirms that the B dissolved in groundwater is anthropogenic. In fact, the δ11B values of groundwater B match the range −12.2‰ to −13.3‰ of the Turkish B mineral (colemanite) processed in boric acid manufacturing, in the course of which no significant isotopic effects have been observed. This isotopic tracing of the Cecina alluvial aquifer occurs just below the confluence of the Possera Creek, which carries the B releases from Larderello. Strontium isotope ratios support this conclusion.At about 18 km from the Possera Creek confluence, the groundwater δ11B drops to much more negative values (−22‰ to −27‰), which are believed to be produced by adsorption–desorption interactions between dissolved B and the aquifer matrix. The δ11B of B fixed in well bottom sediments shows a similar variation. At present, desorption is prevailing over adsorption because the releases of B-rich water have ceased. A theoretical model is suggested to explain the isotopic trends observed.Thus, B isotopes appear to be a powerful tool for identifying the origin of B contamination in natural waters, although isotopic effects associated with adsorption–desorption processes may complicate the picture, to some extent.  相似文献   

15.
根据焉耆盆地开都河水及其两岸地下水中的氢氧稳定同位素资料及氘过量参数(d)值,分析了焉耆盆地内不同水体的δ(D)、δ(18O)和d值的分布规律,并得到地下水的主要补给来源及其与开都河水的相互作用关系;地下水的δ(D)在-87.60‰~-61.82‰间,δ(18O)在-10.90‰~-9.73‰间;开都河水的δ(D)在-71.95‰~-58.58‰间,δ(18O)在-9.57‰~-8.64‰间。结果表明:焉耆盆地内地下水和地表水同源于山区的降水和冰雪融水,且经历了较强的蒸发作用;地下水与地表水之间的直接水力联系较弱,深层地下水主要接受开都河水在洪积扇区的入渗补给,浅层地下水主要接受河流引水灌溉入渗;不同深度地下水之间的水力联系较为密切,为统一的地下水系统。  相似文献   

16.
Channel sediment and alluvial aquifer hydraulic properties exert a major control on river–groundwater interactions. Channels and floodplains are often asymmetrical, resulting in differences in sediment hydraulic properties across the river. Floodplain asymmetry is common along Coastal Plain rivers in South Carolina and North Carolina, USA. The Tar River, North Carolina, has an asymmetrical valley. The study objective was to characterize the effects of floodplain asymmetry and geological controls on river–groundwater interactions. Floodplain and river channel sediments adjacent to the river were characterized with split spoon cores and hand auger samples along a 22-km reach. Hydrogeology was characterized with 38 piezometers and water level recorders in and adjacent to the river. Ground penetrating radar was used to define the shallow stratigraphy. Channel sediments were significantly different between the north and south sides of the river. Hydraulic conductivity and groundwater inputs were greater on the side of the river (north) that contained more permeable fluvial deposits. Groundwater chemistry (δ18O, specific conductance) data also suggested greater exchange between surface water and groundwater on the north side of the river channel. A conceptual hydrogeological model illustrates that groundwater movement and contaminant transport to the river differs across the channel due to asymmetrical geology.  相似文献   

17.
Many cities around the world are developed at alluvial fans. With economic and industrial development and increase in population, quality and quantity of groundwater are often damaged by over-exploitation in these areas. In order to realistically assess these groundwater resources and their sustainability, it is vital to understand the recharge sources and hydrogeochemical evolution of groundwater in alluvial fans. In March 2006, groundwater and surface water were sampled for major element analysis and stable isotope (oxygen-18 and deuterium) compositions in Xinxiang, which is located at a complex alluvial fan system composed of a mountainous area, Taihang Mt. alluvial fan and Yellow River alluvial fan. In the Taihang mountainous area, the groundwater was recharged by precipitation and was characterized by Ca–HCO3 type water with depleted δ18O and δD (mean value of −8.8‰ δ18O). Along the flow path from the mountainous area to Taihang Mt. alluvial fan, the groundwater became geochemically complex (Ca–Na–Mg–HCO3–Cl–SO4 type), and heavier δ18O and δD were observed (around −8‰ δ18O). Before the surface water with mean δ18O of −8.7‰ recharged to groundwater, it underwent isotopic enrichment in Taihang Mt. alluvial fan. Chemical mixture and ion exchange are expected to be responsible for the chemical evolution of groundwater in Yellow River alluvial fan. Transferred water from the Yellow River is the main source of the groundwater in the Yellow River alluvial fan in the south of the study area, and stable isotopic compositions of the groundwater (mean value of −8.8‰ δ18O) were similar to those of transferred water (−8.9‰), increasing from the southern boundary of the study area to the distal end of the fan. The groundwater underwent chemical evolution from Ca–HCO3, Na–HCO3, to Na–SO4. A conceptual model, integrating stiff diagrams, is used to describe the spatial variation of recharge sources, chemical evolution, and groundwater flow paths in the complex alluvial fan aquifer system.  相似文献   

18.
Oxygen isotopes and strontium concentrations were used as geochemical tracers to discern the sources of water to Celestún Lagoon, a small subtropical estuary on the western side of the Yucatán Peninsula of Mexico. Celestún Lagoon is underlain by karstified limestone with numerous locations where groundwater is observed discharging directly to the lagoon. In this study, samples of groundwater, lagoon surface water, and seawater (SW) were collected in April 2008 and June 2009 and analyzed for salinity, stable isotopes of oxygen, and strontium (Sr2+) concentrations. These geochemical tracers were used in two tertiary mixing models to calculate the relative ratio inputs of fresh groundwater, brackish groundwater, and SW to the lagoon. Two sources of groundwater were found to contribute to the surface water in the lagoon; one fresh and the other brackish with an average salinity of 19 psu. The fresh groundwater had an oxygen isotopic signature (δ18O) and strontium concentration (Sr2+) of δ18O?=?-3.30‰ and Sr2+?=?0.03 mmol/l, respectively. The brackish groundwater observed in the northern end of the lagoon add a dissimilar oxygen isotopic signature and Sr2+ concentration of δ18O?=?3.01‰ and Sr2+?=?0.12 mmol/l, respectively. Local SW had an isotopic oxygen signature and Sr2+ concentration between the two fresher sources (δ18O?=?1.40‰, Sr2+?=?0.09 mmol/l). The lagoonwide results of the two tracer mixing models (δ18O and Sr2+) agreed well (within 5 %) and indicated a ratio of brackish groundwater–fresh groundwater– SW of 31 %–26 %–43 % (±5 %) for the Sr2+ model and 35 %–25 %–40 % (± 5 %) for the δ18O model. Brackish groundwater is dominant in the northern portion of the lagoon, while SW dominates the southern portion. Fresh groundwater discharge is a significant contributor of water along the entire eastern boundary of the lagoon where mangrove forests are the dominant vegetation.  相似文献   

19.
河流与地下水相互作用研究是水文学研究的难点和热点。安阳河与地下水相互作用研究,对于安阳市水资源科学开发与管理具有重要意义。安阳河冲洪积扇地表水与地下水转化率为17%~27%。潜水位标高为80 m,向下游逐渐变成多层含水层(水位40 m)。当地降水环境同位素监测数据表明,当地大气降水线与全球大气降水线接近平行,表明该线代表本地区大气降水的氢氧同位素特征。地表水同位素值较集中,2016年8月δ18O值变化范围为-9‰~-8.7‰,δD值变化范围为-65‰~-63‰,2017年1月δ18O值变化范围为-8.5‰~-8.2‰,δD值变化范围为-63‰~-61‰,河水水化学类型为HCO3·SO4—Ca型,表明流域内地表水的同位素值受距离的影响较小。地下水稳定同位素值变化较大,2016年8月δ18O值范围为-10.4‰~-5.5‰,δD值范围为-75‰~-46‰,2017年1月δ18O值范围为-10.2‰~-5.4‰,δD值范围为-75‰~-45‰,即从接近降水值到最大值形成一条“蒸发”线。河流出山口一带地下水同位素值呈现最大蒸发值,表明地表水补给地下水,地下水化学类型为HCO3·SO4·Cl—Ca,存在明显人为污染成分。下游为大气降水补给浅层地下水,中深层地下水主要来源于中游侧向径流,水化学类型主要为HCO3—Ca·Mg型,综合分析表明,安阳河中下游(冲洪积扇)地带“三水”转换积极,并影响其水质、水量。  相似文献   

20.
《Applied Geochemistry》2004,19(2):231-243
In large parts of rural Argentina people depend on groundwater whose As content exceeds the Argentine drinking water standards (0.05 mg l−1). The most affected areas are located in the Chaco-Pampean Plain, where aquifers comprise Tertiary loess deposits (in the Pampean Plain) and Tertiary and Quaternary fluvial and aeolian sediments (in the Chaco Plain). Robles county is located in the alluvial cone of the Dulce River consisting of loess (aeolian), and gravel, silt, sand and clay (alluvial) deposits. In the shallow aquifers, more than 48% of the 63 studied wells show As at toxic levels (maximum 4.8 mg l−1), while in the deep groundwater the concentration is below 0.05 mg l−1. The pH of the shallow groundwaters range between 6.5 and 9 and generally have high electrical conductivity with mean values of 2072 and 1693 μS/cm−1 in the years 1998 and 1999, respectively. Arsenic concentrations are high in the alkaline Na–HCO3 type groundwaters, where As correlates positively with Na+ and HCO3. Moreover, As correlates positively with Mo, U, and V, while a negative correlation was observed with Ca2+ and Mg2+. The potential sources of groundwater As are: (i) layers of volcanic ash with 90% of rhyolitic glass; (ii) volcanic glass dispersed in the sediments; and (iii) clastic sediments of metamorphic and igneous origin. Great lateral variability in the concentration of groundwater As is caused by several hydrogeological and hydrogeochemical factors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号