首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Compensation pumping is used to alleviate deficiencies in streamflow discharge during dry seasons. Short-term groundwater pumping can use aquifer storage instead of catchment-zone water until the drawdown reaches the edge of the stream. The capacitance is a complex, dimensionless parameter of an aquifer system that defines the delayed effect on streamflow when there is groundwater pumping. This parameter is a function of aquifer hydraulic characteristics, pumping time, and distance between the well and stream edge; the latter can involve stream leakance and vertical leakance of an associated aquitard. Three typical hydraulic cases of combined water systems (major catchment-zone wells close to the stream and compensation pumping wells) were classified depending on their capacitance structure (i.e. the relationship between surface water and groundwater): (1) perfect hydraulic connection between the stream and aquifer; (2) imperfect hydraulic connection between the stream and aquifer; and (3) essentially imperfect hydraulic connection between the stream and the underlying confined aquifer. The impact of various hydraulic characteristics and engineering factors on stream depletion was examined by conceptual and numerical modeling. To predict the suitability and efficiency of a combined water system application, regression tests were undertaken on unit stream depletion and capacitance, and power dependencies were defined.  相似文献   

2.
In the Apalachicola-Chattahoochee-Flint (ACF) river basin in Alabama, Georgia, and Florida (USA), population growth in the city of Atlanta and increased groundwater withdrawal for irrigation in southwest Georgia are greatly affecting the supply of freshwater to downstream regions. This study was conducted to understand and quantify the effect of irrigation pumpage on the karst Upper Floridan Aquifer and river–aquifer interactions in the lower ACF river basin in southwest Georgia. The groundwater MODular Finite-Element model (MODFE) was used for this study. The effect of two drought years, a moderate and a severe drought year, were simulated. Comparison of the results of the irrigated and non-irrigated scenarios showed that groundwater discharge to streams is a major outflow from the aquifer, and irrigation can cause as much as 10 % change in river–aquifer flux. The results also show that during months with high irrigation (e.g., June 2011), storage loss (34 %), the recharge and discharge from the upper semi-confining unit (30 %), and the river–aquifer flux (31 %) are the major water components contributing towards the impact of irrigation pumpage in the study area. A similar scenario plays out in many river basins throughout the world, especially in basins in which underlying karst aquifers are directly connected to a nearby stream. The study suggests that improved groundwater withdrawal strategies using climate forecasts needs to be developed in such a way that excessive withdrawals during droughts can be reduced to protect streams and river flows.  相似文献   

3.
Field observation and numerical simulations were carried out to evaluate the hydraulic relationship between the shallow and deep aquifer of a High Plains Aquifer system, in which shallow and deep aquifers are separated by an aquitard. Pumping from the lower aquifer resulted in a small drawdown in the upper aquifer and a larger drawdown in the aquitard; pumping from the shallow aquifer caused a small drawdown in the aquitard and the deep aquifer. Analysis of pumping test data gives the values of the hydraulic conductivity of the aquitard and the deep aquifer. Long-term observation of groundwater levels in the shallow and deep aquifers showed that a strong downward hydraulic gradient was maintained during an irrigation season. Numerical simulations were used to calculate the induced leakage of water from the shallow to the deep aquifer. Water budget analyses suggested that after pumping continues for a couple of days, the leakage from the overlying layers begins to supply the majority of the withdrawal from the deep aquifer. However, the induced leakage from the upper shallow aquifer can travel only a few meters into the aquitard, and it can not reach the lower aquifer during a 90 day pumping period. The major portion of the induced leakage occurred during the pumping period, but a small leakage can continue as a residual effect after the pumping period. The vertical hydraulic conductivity of the aquitard plays a major role in partitioning the ratio of the induced leakage for the pumping and after-pumping periods.  相似文献   

4.

The Kosi Fan region of India and Nepal hosts a productive aquifer system. Regional hydrology is highly seasonal, and both groundwater and surface water are used for irrigation. Groundwater depletion is not currently occurring, but there is concern that plans to increase groundwater irrigation will reduce river baseflow, potentially affecting downstream water users. This study presents a model-based analysis of the impacts of groundwater withdrawal on dry-period streamflow and evaluation of management alternatives. A sensitivity analysis was performed in which a range of model parameters were tested around a best-estimate, base-case scenario. A high-reduction scenario was then developed which combined the factors that produced the greatest pumping-induced reduction in dry-season baseflow. Management strategies for 2.5, 5, and 10-km no-pumping buffers around the rivers were tested for the base-case and high-reduction scenarios. Simulations show that groundwater withdrawal equivalent to 30% and 60% of dry-season streamflow for the Kosi and Mahananda rivers, respectively, reduces the current dry-season flow by less than 4%. In the base-case scenario, simulated dry-season baseflow reduction is 1.8% and 2.6% for the rivers, respectively; these reduce to ~1% with a 2.5-km buffer zone. For the high-reduction scenario, dry-season baseflow reductions are 4.7% and 7.0% with no buffer; these reduce to 1.3% and 0.9% with a 5-km buffer for the Kosi and Mahananda rivers, respectively. The small reductions in baseflow relative to the total amount of pumping are due to a pumping-induced increase in rainfall recharge, thus the effects of additional pumping are mitigated.

  相似文献   

5.
The Tabriz area is a densely populated area of northwestern Iran (more than 1.5 million in population) with a large proportion of its drinking, domestic, industrial and agricultural water supplied from groundwater resources. The average rate of drinking and industrial water use in the city of Tabriz is about 3.45 m3 s–1. The Plio-Pleistocene unconfined alluvial tuff aquifer (about 1,275 km2), the most important aquifer in the area, has been known for many years as a reliable resource. The greatest estimated thickness of the alluvial tuff lies in the Saidabad area, with 350 m thickness. There are 994 deep and 284 shallow active pumping wells and 83 qanats operate in the alluvial tuff aquifer. The total water withdrawal from all these artificial discharge points has been measured at 72, 3.8 and 17 million m3/year, respectively. Analytical and numerical methods have been applied to the constant rate pumping test data from the Saidabad wellfield (eight pumping and three observation wells). The values of electrical conductivity in the groundwater of alluvial tuff aquifer range from 203 to 960 μS cm–1 and bicarbonate type water dominates.  相似文献   

6.
Natural or artificial hydraulic connections between a granular aquifer in contact with a fractured-rock aquifer can have significant physical and chemical impacts at both a local and a regional scale. In this study, numerical simulations are conducted in order to illustrate the hydrogeological consequences of such hydraulic relationships. The numerical investigation, based on a conceptual model, focuses on the effects of the hydraulic connections when conducting a pumping test in a well that is set into a granular confined aquifer overlying a fractured-rock aquifer which presents a few fractures directly connected to the granular aquifer. It is illustrated that when interpreting the pumping test with the conventional methods consisting of plotting the drawdown versus time, a bias is introduced on the estimation of the transmissivity of the granular aquifer due to groundwater flowing from the fractured-rock aquifer via connecting fractures. However, it is underlined that plotting drawdown log-derivative versus time helps to diagnose the existence of these hydraulic relationships and therefore avoids committing a bias on the transmissivity estimation of the granular aquifer. Numerical simulation results also illustrate that hydraulic connections between the two aquifers can have significant impacts on the hydrogeochemical signature of the granular aquifer under investigation.  相似文献   

7.
The suitability of a combined water system (CWS) is assessed for meeting drinking-water demand for the city of Arkhangelsk (northwestern Russian Federation), instead of using the polluted surface water of the Northern Dvina River. An appropriate aquifer system (Permilovo groundwater basin) was found and explored in the 1980s, and there were plans then to operate an abstraction scheme using traditional pumping methods. However, the 1980s planned water system was abandoned due to projected impermissible stream depletion such that complete interception of the cone of depression with the riverbed would cause the riverbed to become dry. The design of a CWS is now offered as an approach to addressing this environmental problem. Several sets of major pumping wells associated with the CWS are located on the banks of Vaymuga River and induce infiltration from the stream. The deficiency of the stream flow in dry seasons is compensated for by pumping from aquifer storage. A numerical model was constructed using MODFLOW-2000. The results of the simulation showed the efficiency of the compensation pumping. The streamflow depletion caused by the CWS is equal to the minimum permissible stream flow and is lower than the depletion projected by the abandoned plan. Application of the CWS in the Permilovo groundwater basin makes it possible to meet water demands during water-limited periods and to avoid environmental problems.  相似文献   

8.
The hyper-arid conditions prevailing in Agua Verde aquifer in northern Chile make this system the most important water source for nearby towns and mining industries. Due to the growing demand for water in this region, recharge is investigated along with the impact of intense pumping activity in this aquifer. A conceptual model of the hydrogeological system is developed and implemented into a two-dimensional groundwater-flow numerical model. To assess the impact of climate change and groundwater extraction, several scenarios are simulated considering variations in both aquifer recharge and withdrawals. The estimated average groundwater lateral recharge from Precordillera (pre-mountain range) is about 4,482 m3/day. The scenarios that consider an increase of water withdrawal show a non-sustainable groundwater consumption leading to an over-exploitation of the resource, because the outflows surpasses inflows, causing storage depletion. The greater the depletion, the larger the impact of recharge reduction caused by the considered future climate change. This result indicates that the combined effects of such factors may have a severe impact on groundwater availability as found in other groundwater-dependent regions located in arid environments. Furthermore, the scenarios that consider a reduction of the extraction flow rate show that it may be possible to partially alleviate the damage already caused to the aquifer by the continuous extractions since 1974, and it can partially counteract climate change impacts on future groundwater availability caused by a decrease in precipitation (and so in recharge), if the desalination plant in Taltal increases its capacity.  相似文献   

9.
In this paper, fist-order reliability method (FORM) is used to evaluate the impacts of uncertainties posed by traditional deterministic models on the environment in Jining, China. Because of groundwater contamination in shallow aquifer, and an increase in water demand, the new wells target the confined aquifer with constant pumping rate of 5,000 m3/d. Using Theis equation, the groundwater drawdown is analyzed to determine whether the confined aquifer will be contaminated. Although the piezometric level is higher than the phreatic level by 11.0 m, the risk of drawdown is still 19.49% when the pumping rate of 5,000 m3/d is maintained for 2 years. The deterministic model indicates a drawdown of 8.94 m which is lower than the maximum tolerance drawdown of 11.0 m. The sensitivity and uncertainty analysis reveal that the model result is more sensitive to transmissivity than specific yield, while the reliability analysis offers significant information for the decision makers. This approach exposes and minimizes the risk of undesirable consequences such as groundwater contamination.  相似文献   

10.
The present study concerns the application of a numerical approach to describe the influence of anthropogenic modifications in surface flows (operation of a projected reservoir) on the freshwater-seawater relationships in a downstream coastal aquifer which has seasonal seawater intrusion problems (River Verde alluvial aquifer, Almuñécar, southern Spain). A steady-state finite element solution to the partial differential equation governing the regional motion of a phreatic surface and the resulting sharp interface between fresh water and salt water was used to predict the regional behavior of the River Verde aquifer under actual surface flow conditions. The present model approximates, with simple triangular elements, the regional behavior of a coastal aquifer under appropriate sinks, sources, Neumann and open boundary conditions. A steady-state solution to this numerical approach has been shown to precisely calculate freshwater heads, saltwater thicknesses, and freshwater discharges along steeply sloping coasts. Hence, the adequate treatment and interpretation of the hydrogeological data which are available for the River Verde aquifer have been of main concern in satisfactorily applying the proposed numerical model. Present simulated conditions consider steady-state yearly averaged amounts of external supplies of fresh water in order to determine the influences of the projected Otívar reservoir on the further behavior of the River Verde coastal aquifer. When recharges occur at the coastline, essentially because of freshwater deficits due to groundwater overexploitation, a hypothesis of mixing for the freshwater-saltwater transition zone is made in order to still allow the model to continue calculating groundwater heads under the sea level, and, as a consequence, the resulting seawater intrusion and recharges of saltwater from the sea. Simulations show that a considerable advance in seawater intrusion would be expected in the coastal aquifer if current rates of groundwater pumping continue and a significant part of the runoff from the River Verde is channeled from the Otívar reservoir for irrigation purposes.  相似文献   

11.
利用新疆阿克苏台兰河流域冲洪积平原区非稳定流抽水试验资料,以辐射井为研究对象,结合辐射管内的水头损失及流态,建立粗颗粒潜水含水层渗流和水平管流耦合的地下水流数值模型。利用数值模型,分析在粗颗粒含水层中辐射管不同根数、不同长度、等效渗透系数、辐射井的井径以及不同含水层的渗透系数、不同降深对辐射井出水量的影响,并且根据各参数的相互关系,提出冲洪积平原辐射井的出水量的经验公式。为优化设计辐射井结构及辐射井布置提供依据,对台兰河地下水库的建设及后期运行管理提供了技术支撑。  相似文献   

12.
Under the current condition of climate change, droughts and floods occur more frequently, and events in which flooding occurs after a prolonged drought or a drought occurs after an extreme flood may have a more severe impact on natural systems and human lives. This challenges the traditional approach wherein droughts and floods are considered separately, which may largely underestimate the risk of the disasters. In our study, the sudden alternation of droughts and flood events (ADFEs) between adjacent seasons is studied using the multivariate L-moments theory and the bivariate copula functions in the Huai River Basin (HRB) of China with monthly streamflow data at 32 hydrological stations from 1956 to 2012. The dry and wet conditions are characterized by the standardized streamflow index (SSI) at a 3-month time scale. The results show that: (1) The summer streamflow makes the largest contribution to the annual streamflow, followed by the autumn streamflow and spring streamflow. (2) The entire study area can be divided into five homogeneous sub-regions using the multivariate regional homogeneity test. The generalized logistic distribution (GLO) and log-normal distribution (LN3) are acceptable to be the optimal marginal distributions under most conditions, and the Frank copula is more appropriate for spring-summer and summer-autumn SSI series. Continuous flood events dominate at most sites both in spring-summer and summer-autumn (with an average frequency of 13.78% and 17.06%, respectively), while continuous drought events come second (with an average frequency of 11.27% and 13.79%, respectively). Moreover, seasonal ADFEs most probably occurred near the mainstream of HRB, and drought and flood events are more likely to occur in summer-autumn than in spring-summer.  相似文献   

13.
Changes in hydrogeological properties of the River Choushui alluvial fan aquifer before and after the 1999 Chi-Chi earthquake, Taiwan, have been identified using pumping tests. Three wells, SH2, YL2 and SC2, located in a compressional zone with high coseismic groundwater levels, were tested. The threshold of the aquifer deformation with respect to transmissivity (T) is greater than that with respect to storage coefficient (S). Decreases in the post-earthquake S are approximately 60% at SH2 and SC2, indicating aquifer compression after the Chi-Chi earthquake. Changes in the post-earthquake T range from 61% increase to 0.8% decrease. Moreover, results from anisotropy analysis of T at SC2 further illustrate that normal stresses induced by the Chi-Chi earthquake have consolidated soil particles. Soil particles dilated laterally after the earthquake, resulting in an increase of the equivalent T. The changes in hydrogeological properties have a considerable influence on spatiotemporal fluid pressure and horizontal groundwater movement, resulting in different amounts of drawdown during post-earthquake pumping.  相似文献   

14.
全球气候变化影响了气象水文要素的时空分布特性,气象水文干旱事件的转化关系及风险传播特征亟待研究。基于站点、栅格观测资料和CMIP5(Coupled Model Inter-comparison Project Phase5)的19个气候模式输出数据,采用新安江等4个水文模型模拟了中国135个流域历史(1961—2005年)和未来时期(2011—2055年,2056—2100年)的水文过程,计算了SPI(Standard Precipitation Index)和SRI(Standard Runoff Index)干旱指标,通过游程理论识别了气象干旱与水文干旱事件,利用Copula函数与最大可能权函数度量二维干旱风险特征,定量评估了气象干旱至水文干旱的潜在风险传播特性。结果表明:①气象-水文干旱对气候变化响应强烈,华北和东北地区的干旱联合重现期增大,干旱潜在风险减小,华中和华南地区的干旱联合重现期减少60%~80%,干旱潜在风险增加;②气象干旱与水文干旱风险在历史和未来时段均存在显著的正相关关系,相关系数超过0.99;③各流域水文干旱风险变化对气象干旱风险变化的敏感程度不会随气候变暖发生较大变化,但未来北方地区水文干旱同气象干旱同时发生的概率将会小幅度增加。  相似文献   

15.
The Albian aquifer of the Paris Basin (France) has been exploited since 1841 and shows drastic drawdown. A three-dimensional (3D) groundwater flow model is used to study the hydrodynamic response of the multi-layered aquifers to pumping activity in the Albian, at basin scale over 167 years. This 3D flow model uses geometry and hydrodynamic parameter distributions that are inherited from a genetic approach through basin modelling, the basin model creating a geometric pattern of hydrodynamic properties constrained by geological history. The paper aims to promote the use of the basin model approach (long time scale, 248 Ma) for the study of deep-aquifer response to anthropogenic perturbation (short time scale, 167 years) in situations for which hydrodynamic data are scarce but geological data are numerous. The results show that parameter distribution is insufficient to reproduce the Albian aquifer behaviour, notably highlighting a different meaning of the specific storage coefficient between basin modelling and groundwater-flow modelling. Dividing the storage coefficient by 100 and including available transmissivity data significantly improved the model/data comparison. The potential impact on a deep aquitard is then discussed. This study sheds light on the advantages and limitations of the basin model approach for groundwater-flow modelling in 3D.  相似文献   

16.
Droughts are complex natural hazards that, to a varying degree, affect some parts of the world every year. The range of drought impacts is related to drought occurring in different stages of the hydrological cycle and usually different types of droughts such as meteorological, agricultural, hydrological, and socio-economical are the most distinguished types. Hydrological drought includes streamflow and groundwater droughts. In this paper, streamflow drought was analyzed using the method of truncation level (at 70 % level) by daily discharges at 54 stations in southwestern Iran. Frequency analysis was carried out for annual maximum series of drought deficit volume and duration. 35 factors such as physiographic, climatic, geologic and vegetation were studied to carry out the regional analysis. According to conclusions of factor analysis, the six most effective factors include watershed area, the sum rain from December to February, the percentage of area with NDVI <0.1, the percentage of convex area, drainage density and the minimum of watershed elevation, explained 89.2 % of variance. The homogenous regions were determined by cluster analysis and discriminate function analysis. The suitable multivariate regression models were ascertained and evaluated for hydrological drought deficit volume with 2 years return period. The significance level of models was 0.01. The conclusion showed that the watershed area is the most effective factor that has a high correlation with drought deficit volume. Moreover, drought duration was not a suitable index for regional analysis.  相似文献   

17.
This paper proposes a simplified analytical solution considering non-Darcian and wellbore storage effect to investigate the pumping flow in a confined aquifer with barrier and recharge boundaries. The mathematical modelling for the pumping-induced flow in aquifers with different boundaries is developed by employing image-well theory with the superposition principle, of which the non-Darcian effect is characterized by Izbash’s equation. The solutions are derived by Boltzmann and dimensionless transformations. Then, the non-Darcian effect and wellbore storage are especially investigated according to the proposed solution. The results show that the aquifer boundaries have non-negligible effects on pumping, and ignoring the wellbore storage can lead to an over-estimation of the drawdown in the first 10 minutes of pumping. The higher the degree of non-Darcian, the smaller the drawdown.  相似文献   

18.
浊水溪冲积扇是台湾水资源最为丰富但也是地面沉降最严重地区。近年来该区域的地面沉降因有可能威胁高铁行车安全而备受关注。本文整合历年累积的地下水位及地面沉降等相关监测数据,验证了地下水位变化与含水层补给之机制,探讨了地下水周期性波降条件下土层压缩特性以及高铁路堤与桩基础工程结构的沉降行为。认为对于设置桩基础的线型高架结构而言,区域性地下水位波降不致增加桥墩间的差异沉降,但桩基础若承受邻近局部的额外载重,则可能伴随地下水位波降产生持续性的差异沉降,其长期效应将对线型交通结构物的平整度及安全性造成负面影响。  相似文献   

19.
工程建设中当距离抽水井r=rb处水位基本没有变化或不受抽水影响时,或当此处存在止水帷幕时,含水层系统视为侧向有限延伸,rb为有限半径。为此,构建更加符合工程实际的侧向有限延伸的典型弱透水层-承压水层系统中非完整井非稳定流计算模型,同时考虑井径和井储效应的影响,应用Laplace变换和分离变量法得到了水位降深在拉氏空间下的解析解,并应用拉氏数值逆变换Stehfest法得到真实空间下的水位降深。新建立的解析解可以进一步退化为诸多已有解,并进一步将其与已知解和有限元数值解进行对比,验证了所得解的正确性和可靠性。基于新建解重点分析了侧向边界和井的完整性对承压水层水位降深的影响。结果表明:含水层系统的侧向有限边界仅对抽水后期的水位降深影响明显,含水层系统侧向无限延伸情况下的水位降深要大于情形1(在r=rb处为定水头边界)且明显小于情形2(在r=rb处为不透水边界)下的水位降深,rb越小,两者之间的误差越大;抽水井的完整性对整个抽水期间不同情形下的水位降深均有明显的影响,承压含水层顶板处的水位降深随着抽水井滤管的长度和埋深的增加而减小。  相似文献   

20.
The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems. As groundwater flows through an aquifer, its composition and temperature may variation dependent on the aquifer condition through which it flows. Thus, hydrologic investigations can also provide useful information about the subsurface geology of a region. But because such studies investigate processes that follow under the Earth's shallow, obtaining the information necessary to answer these questions is not continuously easy. Springs, which discharge groundwater table directly, afford to study subsurface hydrogeological processes.The present study of estimation of aquifer factors such as transmissivity (T) and storativity (S) are vital for the evaluation of groundwater resources. There are several methods to estimate the accurate aquifer parameters (i.e. hydrograph analysis, pumping test, etc.). In initial days, these parameters are projected either by means of in-situ test or execution test on aquifer well samples carried in the laboratory. The simultaneous information on the hydraulic behavior of the well (borehole) that provides on this method, the reservoir and the reservoir boundaries, are important for efficient aquifer and well data management and analysis. The most common in-situ test is pumping test performed on wells, which involves the measurement of the fall and increase of groundwater level with respect to time. The alteration in groundwater level (drawdown/recovery) is caused due to pumping of water from the well. Theis (1935) was first to propose method to evaluate aquifer parameters from the pumping test on a bore well in a confined aquifer. It is essential to know the transmissivity (T = Kb, where b is the aquifer thickness; pumping flow rate, Q = TW (dh/dl) flow through an aquifer) and storativity (confined aquifer: S = bSs, unconfined: S = Sy), for the characterization of the aquifer parameters in an unknown area so as to predict the rate of drawdown of the groundwater table/potentiometric surface throughout the pumping test of an aquifer. The determination of aquifer's parameters is an important basis for groundwater resources evaluation, numerical simulation, development and protection as well as scientific management. For determining aquifer's parameters, pumping test is a main method. A case study shows that these techniques have been fast speed and high correctness. The results of parameter's determination are optimized so that it has important applied value for scientific research and geology engineering preparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号