首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Elemental concentration data on up to 73 individual constituents in BIR-1, DNC-1, and W-2 have been collected from 94 journal articles and technical reports. These data are summarized in consensus (mean) values with uncertainties expressed as one standard deviation. Mean values are also calculated as a function of analytical procedure and all raw data are given in the tables.
Ce rapport rassemble des données analytiques sur 73 éléments dans trois échantillons, BIR-1, DNC-1 et W-2, publiées dans 94 articles scientifiques ou rapports techniques. Quand cela a été possible, les valeurs de consensus (moyenne) sont présentées pour chaque élément avec l'incertitude exprimée un écart-type. Des valeurs moyennes en fonction des procédures analytiques sont également présentées.  相似文献   

2.
Elemental composition data on BHVO-1, MAG-1, QLO-1, RGM-1, SCo-1, SDC-1, SGR-1 and STM-1 have been compiled from 80 journal papers and reports. Mean values with standard deviations are provided for 76 elements.  相似文献   

3.
The trace elements Ce, Co, Cr, Cs, Dy, Eu, Gd, Hf, La, Nd, Ni, Rb, Sb, Sc, Sm, Ta, Tb, Th, Tm, U, V, Yb and Zr have been determined by instrumental neutron activation analysis and U by delayed neutron counting in the USGS standard rock samples STM-1, RGM-1, QLO-1, SDC-1, BHVO-1, SCo-1, SGR-1 and MAG-1. The results are compared with those found in the literature.  相似文献   

4.
A simplified calcium oxalate and ferric hydroxide coprecipitation procedure was applied for quantitative separation and concentration of yttrium and the rare-earth elements from eight USGS (STM-1, RGM-1, QLO-1, SCo-1, MAG-1, SDC-1, BHVO-1, SGR-1), three French (MA-N, AN-G, BE-N), four South African (NIM-35/71–38/71) reference rocks and one NBS coal (1632) before determination by flame and graphite furnace atomic absorption and optical-emission spectroscopy. The results agree or fall near mid-range of other published values, where available. The chondrite normalized distribution patterns are generally smooth and conform to the shapes of other analyzed samples of similar nature.  相似文献   

5.
A series of five Belgian sedimentary rock reference samples (shale AWI-1, schist SBO-1, psammite PRI-1, limestone CCH-1 and dolomite DWA-1) have been prepared for collaborative studies on their chemical composition. Tables of results compiled from 18 laboratories are presented for about 60 major, minor and trace elements. These data are summarized into means, associated standard deviations, medians and ranges. The values received from the participating laboratories are also listed.
Cinq échantillons de roches sédimentaires belges (argilite AWI-1, schiste SBO-1, psammite PRI-1, calcaire CCH-1 et dolomie DWA-1) ont été préparés comme étalons géochimiques. Des valeurs provisoires sont proposés pour 60 éléments majeurs, mineurs et en traces basées sur les données analytiques de 18 laboratoires ayant participé' cette étude coopérative. Les résultats communiqués sont intégralement présentés. Les laboratoires intéressés sont invités à contribuer aux données analytiques sur ces étalons.  相似文献   

6.
Cinquième de la serie des rapports d'étude coopérative sur les standards géochimiques du CRPG, ce rapport est consacré exclusivement aux éeléments en traces dans trois éahantillons en circulation depuis 1963: les Granites GA et GH et le Basalte BR. La pré-sentation de plus de 2000 données analytiques réporties sur 50 éléments est accompagnée d'une évaluation statistique et critique, échantillon par éahmtillon et élément par élément. La discussion est menée dans le sens d'un dialogue direct avec I'utilisateur en nuançant et en hiérarchieant les valeurs que nous veoamnandons ou proposons. Quant à I'analyste practician, il trouvera une table des valeurs "utilisables" pour une trentaine d'éléments dans les trois échantillons de référence (Table 4). Rappelons que ces échantillons sont déjà bien caractérises en ce qui concerne leurs constituants majeurs et mineurs, grâce aux quatre rapports d'étude coopérative dont le dernier est paru en 1370.  相似文献   

7.
Twenty-two geochemical reference standards obtained from the U.S. Geological Survey (AGV-1, PCC-1, G-2, GSP-1, BHVO-1, MAG-1, QLO-1, RGM-1, SCo-1, SDC-1, SGR-1, STM-1, BIR-1, DNC-1, W-2, Nod A-1, Nod P-1), the National Bureau of Standards (SRM 278 Obsidian, SRM 688 Basalt), the International Atomic Energy Agency (Soil-5, SL-1 Lake Sediment), and Batelle Pacific Northwest Laboratories (COS-1 Oil Shale) have been analyzed for up to twenty-one major, minor, and trace elements from the group of H, B, C, N, Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Mn, Fe, Co, Ni, Cu, Cd, Nd, Sm and Gd. The technique used, in-beam neutron-capture prompt γ-ray activation analysis (PGAA), is described and the data are compared to those from other studies.  相似文献   

8.
L'activation neutronique a été appliquée à l'analyse des échantillons végétaux de référence préparés par le Comité Inter-Instituts pour l'analyse foliaire. Les éléments suivants: Al, Ba, Br, Cr, Cs, Mn, La, Th qui intéressent en particulier la prospection géochimique ont ainsi été déterminés sur 13 échantillons. Les conditions analytiques sont données; la précision et la justesse sont discutées. Des comparaisons avec des résultats obtenus par d'autres méthodes sont données pour certains éléments (Mn, Al).  相似文献   

9.
Silicate rock standards AN-G, BHVO-1, QLO-1, RGM-1, SDC-1 and STM-1 have been analyzed for 7 REE (La, Ce, Sm, Eu, Tb, Yb and Lu), Na2O, FeOt, Sc, Co, Cr, Ta, Hf and Th by instrumental neutron activation analysis. The mean values are compared to those from other studies reported in the literature.  相似文献   

10.
Les teneurs de huit éléments des terres rares (La, Ce, Nd, Sm, Eu, Tb, Yb, Lu) sont déterminées par l'analyse par l'activation neutronique instrumentale sur l'Echantillon Géochimique de Référence NBS 88a. Ces teneurs proviennent de la moyenne arithmétique de dix analyses de NBS 88a. Elles se comparent bien avec d'autres déterminations de ces éléments publiées dans la littérature. Dans la limite de la précision analytique, NBS 88a paraît homogène en ce qui concerne les terres rares.  相似文献   

11.
Le Comité Inter-Instituts présente quelques résultats nouveaux, obtenus sur la série d'étalons végétaux qu'il a constitué (12 éahantillons). Le sodium est déterminé par spectrométrie d'émission de flamme, le chlore par titrimétrie potentiométrique, le soufre pap turbidimétrie, le bore par colorimétrie à l'azométhine H.
Les résultats donnés sont les moyennes de 8 à 15 laboratoires selon les éléments. L'éaart-type et le coefficient de variation sont donnés pour chaque résultat. Les résultats de Na, Cl, B sont considérés comme valeurs de référence.
Quelques résultats d'éléments trace par spectrographie d'émission, Al, Co, Cr, Li, Mo, Ni, Pb, Sn, Sr, Ti, V sont présentés comme valeurs d'orientation.  相似文献   

12.
Six roches standards de I'USGS : GXR-1 à GXR-6 ont été analysées par activation neutronique instrumentale (INAA) pour le dosage de 17 éléments traces et par fluorescence X (XRF) pour les autres éléments difficiles à doser par activation neutronique. Les travaux précédemment publiés par Gladney et al. ont été pris comme référence en particulier les valeurs recommandées (R.V.) qui sont généralement en bon accord avec nos résultats. Quelques remarques et corrections sont proposées pour expliquer certaines disparités.
Six United States Geological Survey's (USGS) Geochemical Exploration References Samples (GXR) have been analyzed by instrumental neutron activation analysis (INAA) for the determination of seventeen trace elements and by X-ray fluorescence spectrometry (XRFS) for other trace elements difficult to determine by INAA. Our results compare favourably with the values recommended by E.S. Gladney et al. Some suggestions and corrections are proposed to explain some discrepancies.  相似文献   

13.
Additional analytical data for the thirteen oxides usually determined in a rock analysis by wet methods and estimates and, conclusions from the analysis of variance are presented for the eight new USGS rock standards STM-1, RGM-1, QLO-1, SCo-1, MAG-1, SDC-1, BHVO-1 and SGR-1. The "single-solution" method of sample dissolution, and the "rapid methods" described by Shapiro were used. Three bottles of each standard were analyzed in duplicate, providing six replicate analyses of each sample. Relative standard deviations ranged from 0. 00 to 202 %, with only 12 of the possible 104 sample-oxide combinations exceeding 10 %. Most deviations exceeding 10 % occur with oxides at very low concentrations or with the determi-nation, of H2O+ and CO2, all of which often yield poor precision. These data indicate that the rapid wet chemical methods, except possibly for H2O+ and CO2, or when very low concentrations are present, can be considered reliable. Of the 104 F-ratios calculated during the analysis of variance for sample-oxide combinations, only eight equal or exceed the tabled value of 9. 55 for F0.95 (d. f. 2, 3). These data strongly support the conclusion that the contents of the bottles may be considered homogeneous for most oxides determined. When our data for an oxide in the several samples are plotted versus similar data in the USGS Prof. Paper 840 by several methods, the plots generally show good agreement for most sample-oxide combinations, but approximately thirty of the 104 show substantial differences, with no obvious correlation between the various methods used or the nature or magnitude of the differences.  相似文献   

14.
Lee réaultata interlaboratoires obtenus sur douze plantes destinées à servir d'étolons sont présentés. L'analyse porte sur les éléments N, P, K, Ca, Mg, Fe, Cu, Mn, Zn. Les résultats comprennent la moyerme calctulée arithmétiquement, la médiane, la distribution, I'éaart-type, le coefficient de variation et la valeur recommandée pour chaque élément.  相似文献   

15.
Les roahes carbonatées et siliaatées appar-tiement à un domaine de compositions dans lequel la mesure d'un fond libre d'interférence ou d'une rate diffusée du tube peut permettre à la fois de aorriger les effets de pures absorptions et d'étalonner les fonds sous les raies analytiques. Cette propriété est illustrée sur I'exemple du dosage de 6 éléments en traces dans 30 standards géoahimiques.
La méthode proposée permet d'obtenir dans un domaine de concentration de 1 à 2000 ppm des ré-sultats dont la qualité est à rapprocher de la trés grarde rapidité de rmise en oeuvre.  相似文献   

16.
Une étude de représentativité a été effectuée sur un échantillon de sédiment de ruisseau (SRH-1) prélevéà proximité d'un gîte de Cr-EGP-Ni contenu dans la ceinture ophiolitique des Appalaches du Québec (Canada). Notre étude avait pour but de démontrer que l'analyse de quelques grammes de SRH-1 assurait une représentativité adéquate à l'utilisation des teneurs en EGP d'échantillons de sédiment de ruisseau comme outil d'exploration pour les gîtes de Cr-EGP-Ni associés aux séquences ophiolitiques. Pour ce faire, les teneurs en EGP de SRH-1 ont d'abord été caractérisées par pyroanalyse au sulfure de nickel (29 parties aliquotes de 50 g) et par pyroanalyse plombeuse (50 parties aliquotes de 25 g). Dans ce dernier cas, seulement Pt, Pd et Rh ont été mesurés. Ensuite, les EGP ont été mesurés dans des quantités de plus en plus petites de SRH-1 par pyroanalyse au sulfure de nickel (8 parties aliquotes de 15 g, 8 de 8 g et 8 de 5 g). Les résultats démontrent que des prises de 5 g de SRH-1 assurent une représentativité adéquate à l'analyse de Pt et de Ir soit des résultats analytiques similaires (moyennes et écarts types) à ceux découlant de l'analyse d'une prise de 50 g. Il nous a été impossible de juger de la représentativité d'une prise de 5 g en ce qui concerne les déterminations de Pd, Rh, Os, Ru, ces éléments se trouvant sous ou près des seuils de détection dans les prises de 15, 8, et de 5 g.  相似文献   

17.
Une méthode spectrométrique d'émission atomique à plasma conductif a été appliquée pour l'analyse multiélementaire des échantillons USGS GXR-1 à 6. Cette méthode permet de déterminer simultanément 22 éléments: Ag, As, B, Ba, Be, Cd, Co, Cr, Cu, Fe, Mn, Mo, Nb, Ni, P, Pb, Sb, Sn, V, W, Y et Zn, au niveau de traces (ppm) et le Fe en (%). Les résultats obtenus démontrent une bonne concordance avec les valeurs préalablement publiées.  相似文献   

18.
47 étalons géochimiques internationaux dont les huit nouveaux étalons de l'USGS ont été analysés par fluorescence-X et absorption atomique pour Ni, Cu, Zn et par fluorescence-X pour Ga.
Les auteurs développment ici pour la fluores-cence-X les problèmes concernant le choix des fonds, le calcul du fond véritable sous-jacent au pic mesuré, les impuretés des tubes et de l'appareillage. Une méthode directe sur échantillon pulvérulent, non destructive, sans aucune préparation est utilisée.
Trois systèmes de fluorescence-X utilisant deux appareillages (Philips PW 1540 et Siemens SSRS 1) et deux tubes molybdène et or sont confrontés et les moyennes comparée à celles d'une méthode d'absorption atomique par mise en solution de l'échantillon (IL 353).
Les résultats obtenus sont comparés soit aux valeurs recommandées, soit aux moyennes calculées à partir de la littérature. On discute tant les accords que les divergences.  相似文献   

19.
The gold content of sixty geochemical reference samples has been determined by atomic absorption spectrometry using a graphite furnace atomizer after digestion of sample with aqua regia and extraction of gold as chloride by methylisobutylketone. A comparison with published data shows clearly the need for much more data on most samples before consensus values could be assigned.
La teneur en or dans soixante échantillons géochimiques de référence a été déterminée par le spectromètre d'absorption atomique équipé d'un four à graphite. L'échantillon a été mis en solution avec de l'eau régale et l'or extrait avec du methylisobutylketone. Un examen des données publiées sur l'or montre qu'il faut davantage de résultats pour fixer des valeurs de consensus dans la plupart des échantillons.  相似文献   

20.
Data on seventeen Japanese geochemical reference samples are presented. Ten major and twenty-three trace element concentrations as well as the H2O + and H2O- were determined using x-ray fluorescence, colorimetry, coulometry and instrumental thermal neutron activation analysis. Error bars for the methods as well as information on some elements not previously published are presented. Good agreement was generally obtained with the recently published values of Ando.
Dix éléments majeurs et vingt éléments en traces ainsi que H2O+ et H2O- ont été dosés dans 17 échantillons de référence du Service Géologique du Japon. Les méthodes employées sont la spectrométrie de fluorescence-X, la coulométrie, la colorimétrie et l'activation neutronique thermique. En générale, un accord favorable est obtenu avec les valeurs publiées.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号