1.
生物样品中微量元素硒的分析检测,经典方法是湿法消解-氢化物发生原子荧光光谱法(HGAFS)。湿法消解处理生物样品需使用大量试剂,并且消解时间长,样品背景值高;HG-AFS的分辨率较低,已经不能满足微量硒的分析需求。解决生物样品的消解过程缓慢、试剂用量大的问题是提高样品中微量元素硒的检出限和分辨率的前提。本文采用湿法消解和微波消解两种消解体系处理样品,对两种方法制备的溶液分别采用HG-AFS和电感耦合等离子体质谱法(ICP-MS)进行测定,通过对比试验确定了微波消解ICP-MS方法可以实现生物样品中微量硒的准确测定。对比试验表明:采用高压密闭微波消解前处理样品技术可以大大缩短消解时间,减少试剂用量,降低了样品背景值;利用ICP-MS直接进行测定,方法检出限为0.01μg/g,精密度(RSD,n=12)小于4%,低于HG-AFS的检出限(0.03μg/g)和精密度(10%)。微波消解ICP-MS方法操作简单快捷,降低了方法检出限,提高了样品分析的准确度和精密度。  相似文献   

2.
微波消解-磷钒钼黄光度法测定海洋沉积物中总磷   总被引:1,自引:1,他引:0  
采用微波消解样品,磷钒钼黄光度法测定海洋沉积物中总磷。优化了消解用酸的种类和用量、消解时间、消解温度等微波消解条件。选择HNO3作为消解剂,消解最终温度190℃,保持时间15 min,总磷的测定快速和准确。探讨了显色酸度(微波消解液是否需要赶酸)和稀释倍数等测定条件。对两种国家一级沉积物标准物质GBW07314和GBW07311进行分析验证,测定值与标准值相符,相对标准偏差(RSD,n=6)分别为0.74%和1.66%。与常规消解方法进行比对实验,测定结果无显著性差异。与国标GB 17378.5方法相比,该法具有简单、快速、准确、空白值低、环境污染少等优点。在实际样品测定中,取得了满意的结果,适用于海洋沉积物中总磷的测定。  相似文献   

3.
陈海杰  于兆水  邢夏 《物探与化探》2014,(2):393-395,401
为了简化测量植物中汞含量的方法,提高灵敏度及结果的可信度,实验采用微波消解植物样品的办法,使样品经氯化亚锡还原,再用冷原子荧光测定出植物样品中汞的含量。确定了消解样品的方法和微波消解样品的条件,优化了仪器的最佳工作参数。方法检出限0.30×10-9(稀释因子100倍),精密度(n=12)在2.09%~6.05%,加标回收率94.1%~105.5%,方法经生物国家一级标准物质验证方法准确可靠。  相似文献   

4.
微波消解法是处理生物样品的主要技术,但存在处理效率不高等问题还有待进一步研究。本文采用高压低通量(12位)和低压高通量(41位)微波消解法对蔬菜样品进行前处理,电感耦合等离子体质谱法(ICP-MS)测定砷、镉、铬、铜、镍、铅和锌,氢化物发生-冷原子荧光光谱法(HG-CAFS)测定汞。采用两种前处理方法消解标准物质GBW 10010(大米)和GBW 10014(圆白菜),ICP-MS的测定值与标准值基本吻合,全流程加标回收率为91.5%~103.8%;用于测定GBW 10010和GBW 10014,因GBW 10010中铬、铅、砷,GBW 10014中砷的含量较低,测定值与标准值的相对误差较大;其余元素的测定值与标准值基本相符,表明两种前处理方法均能满足分析要求。但在保证测定结果质量的前提下,低压高通量微波消解处理样品,试剂用量少,单次样品处理量大,更加适合大批量生物样品的前处理。  相似文献   

5.
本文采用微波消解-电感耦合等离子体发射光谱法(ICP-OES)对土壤样品中硼含量的测定进行了实验。对微波消解样品前处理条件和测定时的仪器参数进行了优化,最终确定了以HF-HNO_3-H_3PO_4体系,逐级升温的方式来消解土壤样品。该方法对硼元素的检出限为0.093μg/g。经标准物质验证,其准确度、精密度均达到行业标准的要求,适用于土壤样品中硼的测定。  相似文献   

6.
采用微量滴定法测定铜盐中铜的含量,结果表明,方法分析速度快,试剂用量少,与常量滴定法无显著性差异。采用湿法消解、微波消解微量滴定法同时测定铜合金和铜精矿中铜的含量,结果表明,对铜合金的测定,湿法消解和微波消解两者无显著性差异;而对于铜精矿的测定,样品的溶解效果微波消解方法明显优于湿法消解。  相似文献   

7.
研究建立了增压-微波消解电感耦合等离子体质谱法测定含难溶矿物(含铌钽铀矿物、锆石等)岩石样品中微量元素的测试方法。该技术有效地解决了传统湿法消解方法不能完全消解含难溶矿物(含铌钽铀矿物、锆石等)岩石样品的难题。根据超高压-微波消解原理,自行设计加工了电加热增压消解装置一台。该装置的技术创新在于对含难溶矿物岩石样品采用了在同一消解罐中先微波消解再增压消解的方式,解决了微波消解到增压消解的转换问题,实现了对含难溶矿物岩石样品的无交叉污染、低本底、快速地增压-微波消解。通过一系列研究获得了含难溶矿物(含铌钽铀矿物、锆石等)岩石样品的微波-增压消解条件参数,然后采用电感耦合等离子体质谱(ICP-MS)法测定含难溶矿物岩石样品中微量元素含量。经标准物质测试验证,分析方法的定量限为0.004~0.084μg/g,精密度小于5%,测量相对误差小于10%,该方法能满足行业分析测试质量的控制要求。  相似文献   

8.
李刚  高明远  诸堃 《岩矿测试》2010,29(1):17-22
采用过氧化氢-硝酸作溶剂,微波消解样品,外标方法校准,电感耦合等离子体质谱法同时测定植物样品中硼、镉、铜、钴、铬、钼、锂、镍、铅、镧、锗11个微量元素。确定了微波消解仪和等离子体质谱仪的最佳工作参数,研究了有机残留物和共存离子的干扰和消除方法,选择了各元素的测定同位素,以45Sc和103Rh双内标补偿基体效应,建立了样品测定方法。方法检出限(10s)在5~150 ng/g,相对标准偏差(RSD,n=12)在1.27%~5.27%。对多种国家一级生物标准物质进行分析验证,测定值与标准值相符。方法适用于植物的果实、根、茎、叶等不同类型样品中多种微量元素的测定。  相似文献   

9.
用盐酸-氢氟酸-硝酸微波消解对样品进行前处理,电感耦合等离子体发射光谱法测定岩石和矿物中的钼,选择202.03 nm为样品分析谱线,优化了微波消解的实验条件,可消解多个样品,减少了碱熔分解样品方法引入的基体干扰,避免了极谱法中汞对人体的伤害。用不同类型国家一级标准物质分析验证,测定结果与标准值吻合。方法精密度(RSD,n=8)小于2.0%,加标回收率为96.4%~101.3%,方法检出限为0.000 5%。该方法适用于岩石和矿物中钼的测定,制样速度快,操作简便安全,样品重现性好,能满足简单、快速、批量分析的要求。  相似文献   

10.
研究建立了稀氨水-微波消解-电感耦合等离子体质谱法(ICP-MS)测定生态地球化学生物样品中碘的方法。通过采用稀氨水代替硝酸对样品进行消解,较好地解决了测定结果不稳定及记忆效应严重现象;同时,采用离线内标加入法,有效地消除了检测过程中因操作因素等引起的误差和基体效应干扰。进行条件优化实验后,该方法的检出限为0.005μg/g,测定范围0.05~12.5μg/g。使用国家一级生物成分分析标准物质验证,相对误差(RE)为0.53%~7.17%,相对标准偏差(RSD)(n=8)为0.87%~5.81%。实际样品测定加标回收率在94.0%~96.7%之间。建立的方法能有效满足生态地球化学生物样品中碘的测试需求。  相似文献   

11.
建立了微波消解-电感耦合等离子体质谱法测定土壤和沉积物中15种痕量稀土元素的分析方法。研究了溶样试剂、微波消解程序、标准溶液配制、质谱干扰与内标元素对稀土元素测定的影响。加入氢氟酸能有效打开样品,以HNO3-HF-H2O2混合酸溶解样品,稀土元素的溶出率较高。采用模拟土壤、沉积物中稀土元素天然组成比值的校正溶液,对稀土元素间的干扰具有明显的抑制作用。通过测定单个La、Ce、Pr、Nd和Ba的氧化物及氢氧化物产率,计算出等效干扰浓度,进而校正多原子离子干扰。利用103Rh内标校正系统,有效地抑制了分析信号的动态漂移。方法检出限为1.2~7.1 ng/g,精密度(RSD)≤5.3%(n=6),加标回收率为86.1%~110.1%。使用土壤、沉积物标准物质进行验证,测定结果与标准值相符。建立的方法样品处理程序简单快速、线性范围宽、分析重现性好、结果准确,适用于大批量地质样品的分析。  相似文献   

12.
采用HNO3-H2O2体系对植物样品进行风冷回流消解,电感耦合等离子体质谱法(ICP-MS)同时测定植物样品中46个元素的含量。将称有样品的磨口锥形瓶加装风冷管后直接放在普通平板铝块电热板上,一次可对45个锥形瓶回流装置同时进行加热,不需要严格地规定消解时间,保证回流加热微沸消解至消解完全即可。植物标准物质(GBW 10012、GBW 10014和GBW 10019)的分析结果与标准值相一致,方法精密度(RSD,n=6)为0.44%~5.59%。与干法灰化消解和微波消解等样品处理方法相比较,操作简单快捷,试剂用量少,空白值较低,溶液盐度较小,有利于植物样品中多元素ICP-MS同时测定。采用调试液调节ICP-MS仪器测定的最佳化,确定了ICP-MS测定的最佳条件,同时探讨了元素之间的干扰关系,采用数学校正法有效地消除了测定的干扰。  相似文献   

13.
Tests are described showing the results obtained for the determination of REE and the trace elements Rb, Y, Zr, Nb, Cs, Ba, Hf, Ta, Pb, Th and U with ICP-MS methodology for nine basaltic reference materials, and thirteen basalts and amphibolites from the mafic-ultramafic Niquelândia Complex, central Brazil. Sample decomposition for the reference materials was performed by microwave oven digestion (HF and HNO3, 100 mg of sample), and that for the Niquelândia samples also by Parr bomb treatment (5 days at 200°C, 40 mg of sample). Results for the reference materials were similar to published values, thus showing that the microwave technique can be used with confidence for basaltic rocks. No fluoride precipitates were observed in the microwave-digested solutions. Total recovery of elements, including Zr and Hf, was obtained for the Niquelândia samples, with the exception of an amphibolite. For this latter sample, the Parr method achieved a total digestion, but not so the microwave decomposition; losses, however, were observed only for Zr and Hf, indicating difficulty in dissolving Zr-bearing minerals by microwave acid attack.  相似文献   

14.
Data on thirty-four minor and trace elements including all rare earth elements (REE) are reported for two kimberlitic international reference materials (SARM-39, MINTEK, RSA and MY-4, IGEM, Russia) by inductively coupled plasma-mass spectrometry (ICP-MS), some of them for the first time. Four digestion techniques (open acid, closed vessel acid, microwave and lithium metaborate fusion digestion) were used for the decomposition of samples for analysis by ICP-MS. Three other reference materials (USGS BHVO-1, CRPG BR-1 and ANRT UB-N) were analysed simultaneously using the same analytical methodology to assess the precision and accuracy of the determinations. The data obtained in this study compare well with working values wherever such values are available for comparison. Though open acid digestion was found to be very rapid, effective and convenient for the determination of several trace elements in kimberlitic samples, recoveries for heavy rare earth elements (HREE) were lower than the respective recoveries obtained by the other decomposition techniques used. The precision obtained was better than ± 6% RSD in the majority of cases with comparable accuracy. Chondrite-normalised plots of each RM for all the digestion techniques were smooth. The new data reported on the two kimberlitic reference materials make these samples useful for future geochemical studies of kimberlitic rocks.  相似文献   

15.
彭炳先  吴代赦  李萍 《岩矿测试》2010,29(6):761-767
综述了近年来国内外煤中痕量溴测定方法的研究进展,介绍了间接分析法和直接分析法的基本特点和原理。间接分析法是先用高温热水解法、碱熔法或微波处理法等消解煤样品,使煤中溴进入溶液中,再用离子色谱法、电感耦合等离子体质谱法等技术测定煤消解液中溴的含量。直接分析法是用X射线荧光光谱法或中子活化法直接测定固体煤中溴的含量。对各种测试方法的适用性、存在问题及发展方向进行了比较和评述。  相似文献   

16.
Complete dissolution is essential to obtain accurate analytical results using ICP-MS. In this study, decomposition techniques (i.e. acid digestions using Savillex Teflon vials, a high pressure digestion system and microwave oven, a combined lithium tetraborate fusion - HF/HNO3 acid decomposition and sodium peroxide sinter) for the total dissolution of different types of geological reference materials have been investigated. Savillex Teflon vial HF/HNO3 digestion is effective for basaltic samples. The high pressure HF/HClO4 digestion (PicoTrace TC-805 digestion system, Bovenden, Germany) allows dissolution of basalts and ironstones. Granites and magnetite-rich samples can be dissolved using a high pressure HF/H2SO4 method. Geological samples cannot be effectively attacked by microwave acid digestion. A combined lithium tetraborate fusion - HF/HNO3 acid digestion method allows complete dissolution of many different types of geological materials; however, this method precludes the determination of volatile elements due to the high fusion temperature (1000 °C). A sodium peroxide sinter method at 480 °C has the potential for the rapid determination of Y, Sc and REE in different types of geological materials. However, the lack of ultra-pure reagents precludes the use of lithium tetraborate fusion and sodium peroxide sinter methods for the measurement of geological samples with low trace element abundances.  相似文献   

17.
探讨生态地球化学评价湿沉降、悬浮物样品分析体系中,进行多元素含量测定的分析测试新方法及样品的制备技术。根据待测元素的不同,分别采用微波消解、酸溶、碱熔等方法进行样品制备,使用原子荧光光谱法、离子选择电极法、电感耦合等离子体发射光谱法、电感耦合等离子体质谱法等进行样品的测定。文章系统地建立了生态地球化学评价湿沉降、悬浮物样品的多元素分析体系,利用建立的方法对不同种类的国家标准物质进行测定,结果令人满意。  相似文献   

18.
对汤岗子热矿泥白粉中矿物元素进行分析研究。采用微波消解法处理样品,运用电感耦合等离子体质谱法对汤岗子热矿泥白粉中钠、镁、钾、钙、铁、锌、锰、铜、硒、锗、钼、铬、铝、镍、砷、汞、铅等17个矿物元素进行分析。结果表明,在优化实验条件下,方法检出限为0.000279 9~14.66μg/L,相对标准偏差(RSD,n=6)为0.18%~6.20%,回收率为91.1%~108.2%。汤岗子热矿泥白粉中含有丰富的矿物元素。  相似文献   