排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
This paper presents a short theoretical summary of the series expansion-based 2.5D combined geoelectric weighted inversion (CGWI) method and highlights the advantageous way with which the number of unknowns can be decreased due to the simultaneous characteristic of this inversion. 2.5D CGWI is an approximate inversion method for the determination of 3D structures, which uses the joint 2D forward modeling of dip and strike direction data. In the inversion procedure, the Steiner’s most frequent value method is applied to the automatic separation of dip and strike direction data and outliers. The workflow of inversion and its practical application are presented in the study. For conventional vertical electrical sounding (VES) measurements, this method can determine the parameters of complex structures more accurately than the single inversion method. Field data show that the 2.5D CGWI which was developed can determine the optimal location for drilling an exploratory thermal water prospecting well. The novelty of this research is that the measured VES data in dip and strike direction are jointly inverted by the 2.5D CGWI method. 相似文献
2.
Following Hemker and Maas (1987) the models of two or three leaky aquifers are applied to simulate the flow to vertical wells operating in the fractured or dual porosity aquifers. The software WellTest (WT) (Székely 2015) is used for calculating the drawdown and discharge rate variation. The comparative analysis with the independent analytical solutions by Boulton and Streltsova-Adams (1978), Warren and Root (1963), Kazemi et al. (1969) concluded with acceptable agreement between the WT simulation and the alternate calculation methods. The selected field tests have been conducted in fractured limestone aquifers. The pumping test west of Copenhagen shows an example of fractured aquifer with considerable negative skin effect at the well face. The flowing well Wafra W1 in Kuwait operates in the two-zone aquifer exhibiting sufficient vertical recharge via leakage beyond a circular domain of estimated radius of 2460 m. 相似文献
3.
Matyasovszky István Makra László Tusnády Gábor Csépe Zoltán Nyúl László G. Chapman Daniel S. Sümeghy Zoltán Szűcs Gábor Páldy Anna Magyar Donát Mányoki Gergely Erostyák János Bodnár Károly Bergmann Karl-Christian Deák Áron József Thibaudon Michel Albertini Roberto Bonini Maira Šikoparija Branko Radišić Predrag Gehrig Regula Rybníček Ondřej Severova Elena Rodinkova Victoria Prikhodko Alexander Maleeva Anna Stjepanović Barbara Ianovici Nicoleta Berger Uwe Seliger Andreja Kofol Weryszko-Chmielewska Elżbieta Šaulienė Ingrida Shalaboda Valentina Yankova Raina Peternel Renata Ščevková Jana Bullock James M. 《Theoretical and Applied Climatology》2018,133(1-2):277-295
Theoretical and Applied Climatology - The drivers of spatial variation in ragweed pollen concentrations, contributing to severe allergic rhinitis and asthma, are poorly quantified. We analysed the... 相似文献
4.
5.
Factor analysis of borehole logs for evaluating formation shaliness: a hydrogeophysical application for groundwater studies 总被引:1,自引:1,他引:0
The calculation of groundwater reserves in shaly sand aquifers requires a reliable estimation of effective porosity and permeability; the amount of shaliness as a related quantity can be determined from well log analysis. The conventionally used linear model, connecting the natural gamma-ray index to shale content, often gives only a rough estimate of shale volume. A non-linear model is suggested, which is derived from the factor analysis of well-logging data. An earlier study of hydrocarbon wells revealed an empirical relationship between the factor scores and shale volume, independent of the well site. Borehole logs from three groundwater wells drilled in the northeastern Great Hungarian Plain are analyzed to derive depth logs of factor variables, which are then correlated with shale volumes given from the method of Larionov. Shale volume logs derived by the statistical procedure are in close agreement with those derived from Larionov’s formula, which confirms the validity of the non-linear approximation. The statistical results are in good accordance with laboratory measurements made on core samples. Whereas conventional methods normally use a single well log as input, factor analysis processes all available logs to provide groundwater exploration with reliable estimations of shale volume. 相似文献
6.
M. Wilde-Piórko W. H. Geissler J. Plomerová M. Grad V. Babuška E. Brückl J. Cyziene W. Czuba R. England E. Gaczyński R. Gazdova S. Gregersen A. Guterch W. Hanka E. Hegedűs B. Heuer P. Jedlička J. Lazauskiene G. Randy Keller R. Kind K. Klinge P. Kolinsky K. Komminaho E. Kozlovskaya F. Krüger T. Larsen M. Majdański J. Málek G. Motuza O. Novotný R. Pietrasiak Th. Plenefisch B. Růžek S. Sliaupa P. Środa M. Świeczak T. Tiira P. Voss P. Wiejacz 《Studia Geophysica et Geodaetica》2008,52(3):439-448
7.
Gudehus Gerd Lempp Christof Scheffzük Christian Műller Birgit I. Schilling Frank R. 《Acta Geotechnica》2023,18(2):951-969
Acta Geotechnica - Evaluating various investigations for north-German gas fields, we discuss past and actual evolutions of the rock fabric in the light of dilatant driven and spontaneous... 相似文献
8.
1