Relative navigation based on GPS receivers and inertial measurement units is required in many applications including formation flying, collision avoidance, cooperative positioning, and accident monitoring. Since sensors are mounted on different vehicles which are moving independently, sensor errors are more variable in relative navigation than in single-vehicle navigation due to different vehicle dynamics and signal environments. In order to improve the robustness against sensor error variability in relative navigation, we present an efficient adaptive GPS/INS integration method. In the proposed method, the covariances of GPS and inertial measurements are estimated separately by the innovations of two fundamentally different filters. One is the position-domain carrier-smoothed-code filter and the other is the velocity-aided Kalman filter. By the proposed two-filter adaptive estimation method, the covariance estimation of the two sensors can be isolated effectively since each filter estimates its own measurement noise. Simulation and experimental results demonstrate that the proposed method improves relative navigation accuracy by appropriate noise covariance estimation. 相似文献
Acidification of rain water caused by air pollutants is now recognized as a serious threat to aquatic ecosystems. We examined the effects of low pH (control pH 7.5, pH 6, pH 5, pH 4) on the survival, growth, and shell quality of Macrobrachium rosenbergii postlarvae and early juveniles in the laboratory. Hatcheryproduced postlarvae (PL 5) were stocked at 250 PL per aquarium, acclimated over 7 d to experimental pH adjusted with hydrochloric acid, and reared for 30 d. Dead specimens were removed and counted twice a day. After 27 d rearing, all specimens were measured for total length and body weight. Carapace quality was assessed by spectrophotometry. Survival of juveniles was highest at pH 6 (binomial 95% confidence interval 79 - 89%) followed by control pH 7.5 (56 - 68%) and pH 5 (50 - 60%) and was lowest for unmetamorphosed postlarvae and juveniles at pH 4 (43 - 49%). The final median total length and body weight of juveniles were similar at control pH 7.5 (18.2 TL, 50.2 mg BW) and pH 6 (17.7 mm TL, 45.0 mg BW) but significantly less at pH 5 (16.7 mm TL, 38.2 mg BW); at pH 4, the postlarvae did not metamorphose and measured only 9.8 mm TL, 29.3 mg BW. Length frequency distribution showed homogeneous growth at pH 6, positive skew at control pH 7.5 and pH 5, and extreme heterogeneity at pH 4. The carapace showed different transmittance spectra and lower total transmittance (i.e. thicker carapace) in juveniles at pH 7.5, pH 6, and pH 5 than in unmetamorphosed postlarvae and juveniles with thinner carapace at pH 4. Thus, survival, growth, size distribution, and carapace quality of M. rosenbergii postlarvae and early juveniles were negatively affected by pH 5 and especially pH 4. The thinner carapace of the survivors at pH 4 was mostly due to their small size and failure to metamorphose. Natural waters affected by acid rain could decimate M. rosenbergii populations in the wild.
Natural Hazards - In disaster response processes, collaborations among multiple organizations are vital for effective disaster management. This study examined how multiplex ties concerning... 相似文献
Natural Hazards - Australia is one of the most bushfire-prone countries. Prediction and management of bushfires in bushfire-susceptible areas can reduce the negative impacts of bushfires. The... 相似文献
Natural Hazards - Emergency evacuation is the immediate escape of people away from a place of an imminent threat to a place of safety. The ability of the households to evacuate is a crucial... 相似文献
The different algorithms appropriate for point source photometry on data from the SPIRE instrument on-board the Herschel Space Observatory, within the Herschel Interactive Processing Environment (HIPE) are compared. Point source photometry of a large ensemble of standard calibration stars and dark sky observations is carried out using the 4 major methods within HIPE: SUSSEXtractor, DAOphot, the SPIRE Timeline Fitter and simple Aperture Photometry. Colour corrections and effective beam areas as a function of the assumed source spectral index are also included to produce a large number of photometric measurements per individual target, in each of the 3 SPIRE bands (250, 350, 500μm), to examine both the accuracy and repeatability of each of the 4 algorithms. It is concluded that for flux densities down to the level of 30mJy that the SPIRE Timeline Fitter is the method of choice. However, at least in the 250 and 350μm bands, all 4 methods provide photometric repeatability better than a few percent down to at approximately 100mJy. The DAOphot method appears in many cases to have a systematic offset of ~8 % in all SPIRE bands which may be indicative of a sub-optimal aperture correction. In general, aperture photometry is the least reliable method, i.e. largest scatter between observations, especially in the longest wavelength band. At the faintest fluxes, <30mJy, SUSSEXtractor or DAOphot provide a better alternative to the Timeline Fitter. 相似文献
The Fourier Transform Spectrometer (FTS) of the Spectral and Photometric Imaging REceiver (SPIRE) on board the ESA Herschel Space Observatory has two detector setting modes: (a) a nominal mode, which is optimized for observing moderately bright to faint astronomical targets, and (b) a bright-source mode recommended for sources significantly brighter than 500 Jy, within the SPIRE FTS bandwidth of 446.7–1544 GHz (or 194–671 microns in wavelength), which employs a reduced detector responsivity and out-of-phase analog signal amplifier/demodulator. We address in detail the calibration issues unique to the bright-source mode, describe the integration of the bright-mode data processing into the existing pipeline for the nominal mode, and show that the flux calibration accuracy of the bright-source mode is generally within 2 % of that of the nominal mode, and that the bright-source mode is 3 to 4 times less sensitive than the nominal mode. 相似文献
The Herschel SPIRE Fourier transform spectrometer (FTS) performs spectral imaging in the 447–1546 GHz band. It can observe in three spatial sampling modes: sparse mode, with a single pointing on sky, or intermediate or full modes with 1 and 1/2 beam spacing, respectively. In this paper, we investigate the uncertainty and repeatability for fully sampled FTS mapping observations. The repeatability is characterised using nine observations of the Orion Bar. Metrics are derived based on the ratio of the measured intensity in each observation compared to that in the combined spectral cube from all observations. The mean relative deviation is determined to be within 2 %, and the pixel-by-pixel scatter is ~ 7 %. The scatter increases towards the edges of the maps. The uncertainty in the frequency scale is also studied, and the spread in the line centre velocity across the maps is found to be ~ 15 km s ? 1. Other causes of uncertainty are also discussed including the effect of pointing and the additive uncertainty in the continuum. 相似文献
Ocean Science Journal - Sands are distributed in a sheet form across the entire shelf of the Yellow and South seas. They are barely several meters thick except for sand waves and ridges, which are... 相似文献