首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   97篇
  免费   16篇
  国内免费   5篇
测绘学   8篇
大气科学   2篇
地球物理   38篇
地质学   51篇
海洋学   8篇
天文学   5篇
综合类   2篇
自然地理   4篇
  2023年   1篇
  2022年   9篇
  2021年   4篇
  2020年   5篇
  2019年   2篇
  2018年   16篇
  2017年   10篇
  2016年   13篇
  2015年   9篇
  2014年   6篇
  2013年   13篇
  2012年   7篇
  2011年   8篇
  2010年   5篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2004年   2篇
  1999年   1篇
  1989年   1篇
  1979年   1篇
排序方式: 共有118条查询结果,搜索用时 31 毫秒
81.
Using the Sagdeev pseudo-potential technique, further investigation on the effect of nonextensive hot electrons on finite amplitude nonlinear low-frequency electrostatic waves in a magnetized two-component plasma have been reported in detail. The plasma model consists of cold ions fluid and nonextensively distributed electrons. The existence domain for the nonlinear structures have been established analytically and numerically. Apart from the compressive and rarefactive soliton solutions that have been reported earlier, the present investigation shows that double layer structures can be obtained for certain values of nonextensive electrons in the supersonic Mach number regime. The present results may provide an explanation for the observed nonlinear structures in the auroral region of the Earth’s magnetosphere.  相似文献   
82.
Determining in-situ soil or rock geotechnical properties is a difficult task for a design engineer. Back analysis is a helpful technique for evaluating soil property by considering and measuring the convergence of an underground opening. Back analysis was performed by matching numerical modeling results with the measured tunnel convergence. The main purpose of this study was to determine optimum rock mass properties using back analysis in order to suggest the best and most economical support system. Accordingly, the difference between measured and calculated convergence values was minimized by using an error function (objective function). In this paper, through the parameters obtained from back analysis, a support system based on a set consisting of shotcrete, wire mesh, and lattice girder was suggested for the Babolak water conveyance tunnel in Mazandaran, Iran. Therefore, the suggested design was based on decreasing shotcrete thickness from 25 to 20?cm and eliminating of rock bolts.  相似文献   
83.
Adsorption of hexavalent chromium from aqueous solutions by wheat bran   总被引:7,自引:6,他引:1  
In this research, adsorption of chromium (VI) ions on wheat bran has been studied through using batch adsorption techniques. The main objectives of this study are to 1) investigate the chromium adsorption from aqueous solution by wheat bran, 2) study the influence of contact time, pH, adsorbent dose and initial chromium concentration on adsorption process performance and 3) determine appropriate adsorption isotherm and kinetics parameters of chromium (VI) adsorption on wheat bran. The results of this study showed that adsorption of chromium by wheat bran reached to equilibrium after 60 min and after that a little change of chromium removal efficiency was observed. Higher chromium adsorption was observed at lower pHs, and maximum chromium removal (87.8 %) obtained at pH of 2. The adsorption of chromium by wheat bran decreased at the higher initial chromium concentration and lower adsorbent doses. The obtained results showed that the adsorption of chromium (VI) by wheat bran follows Langmuir isotherm equation with a correlation coefficient equal to 0.997. In addition, the kinetics of the adsorption process follows the pseudo second-order kinetics model with a rate constant value of 0.131 g/mg.min The results indicate that wheat bran can be employed as a low cost alternative to commercial adsorbents in the removal of chromium (VI) from water and wastewater.  相似文献   
84.
We construct long-term time series of Greenland and Antarctic ice sheet mass change from satellite gravity measurements. A statistical reconstruction approach is developed based on a principal component analysis (PCA) to combine high-resolution spatial modes from the Gravity Recovery and Climate Experiment (GRACE) mission with the gravity information from conventional satellite tracking data. Uncertainties of this reconstruction are rigorously assessed; they include temporal limitations for short GRACE measurements, spatial limitations for the low-resolution conventional tracking data measurements, and limitations of the estimated statistical relationships between low- and high-degree potential coefficients reflected in the PCA modes. Trends of mass variations in Greenland and Antarctica are assessed against a number of previous studies. The resulting time series for Greenland show a higher rate of mass loss than other methods before 2000, while the Antarctic ice sheet appears heavily influenced by interannual variations.  相似文献   
85.
This study investigated the potential factors affecting arsenic concentration in the groundwater system of Lahore, Pakistan. The effects of several factors such as population density (PD), pumping rate (PR), impermeable land use (LU), surface elevation (SE), and water-table elevation (WL) on arsenic concentration were studied in 101 union councils of Lahore. Forty single and multi-factor models were established using geographic information system (GIS) techniques to develop an arsenic contamination map and to investigate the most effective combinations among factors. Additionally, statistical tests were used to evaluate arsenic concentration between classes of the same single factor. The arsenic concentration in the Lahore aquifer varied from 0.001 to 0.143 mg L?1. The highest arsenic concentrations were detected in the Walled City and the town of Shahdara. Among the 40 raster models, groundwater arsenic concentration showed the best matching frequency with single-factor models for PD (50.70 %) and SE (47 %). Thus, PD and SE were used to develop an arsenic distribution raster map, and they were also used to study the effect of aquifer depth on arsenic concentration. PD was found to have hidden latent variables such as PR and LU. The shallow aquifer depth was negatively correlated with arsenic concentration (r?=??0.23) and positively with PR (r?=?0.15). Therefore, when there was high PR in wells with smaller aquifer depth, the arsenic concentration was high. The existing water treatment and alternative water resources are good options, which should be developed to deal with Lahore wells contaminated with arsenic at high concentrations.  相似文献   
86.
The virani ophiolite complex and surrounding rocks   总被引:1,自引:0,他引:1  
The Virani ophiolite complex consists of metamophosed ultramafics, mafics, and cherts, and forms an allochthonous sheet that structurally overlies a sequence of metamorphosed flysch-type deposits. The complex and structurally underlying metamorphosed sedimentary rocks have been affected by three phases of folding. The first and second phases of folding produced isoclinal folds with subparallel trends and nearly-horizontal axes which resulted in the apparent interlayered character of the rock units.
Zusammenfassung Der Virani-Ophiolith-Komplex besteht aus metamorphen Kieselschiefern neben ultramaphischen und maphischen Gesteinen. Sie liegen über einer Serie von metamorphen Flysch-Sedimenten. Dieser Komplex und die darunter liegenden Sedimente wurden von drei Faltungsphasen beeinflußt. Die erste und zweite Faltungsphase verursachten isoklinale Falten mit subparallelem Streichen und fast horizontalen Achsen.

Résumé Le complexe ophiolitique de Virani consiste en roches métamorphiques ultramafiques, mafiques et en cherts; il forme une couverture allochtone qui recouvre structuralement une série des couches métamorphiques de type flysch. Le complexe et les roches sédimentaires métamorphiques structuralement sous-jacentes ont été affectées par trois phases de plissement. La première et la deuxième phases de plissement ont produit des plis isoclinaux á axes presqu'horizontaux et d'allure subparallèle, qui ont eut pour résultat de donner aux unités lithologiques l'apparence d'intercalations.

, . . , 3- . - , .
  相似文献   
87.
Peng  Ruikun  Zhao  Yinyin  Elahi  Ehsan  Peng  Benhong 《Natural Hazards》2021,106(3):2883-2899
Natural Hazards - The study estimates the impact of disaster shocks and risk perception on farmers’ willingness for insurance. Based on data of 328 farmers from the Shandong province of East...  相似文献   
88.
Acta Geotechnica - Hydraulic conductivity is one of the most important characteristics of unsaturated soils. Its determination is essential for modeling various phenomena of interest such as...  相似文献   
89.
The mixtures of dried sewage sludge (DSS) and sewage sludge ash were studied for removal of acid red 119 (AR119) dye as a new, more environmental friendly, and low cost adsorbent. For this purpose, response surface methodology was applied to optimize the dye removal efficiency and turbidity of treated dye solutions as two individual responses. Results revealed that an optimum condition under specified constraints (dye removal efficiency >95% and turbidity <50 NTU) was obtained at a contact time of 60 min, 40 wt% DSS in the mixture, an initial pH of 6, and an initial dye concentration of 200 mg dye/L in distilled water. Under the optimal condition, dye removal efficiency of 94.98% and effluent turbidity of 24.9 NTU was observed. In further studies, at optimum condition, the effect of some additives on adsorption process and desorption/reusability of adsorbent was investigated. It was observed that removal efficiency was significantly decreased to 83.76% when a simulated dye wastewater (containing the selected dye, acetic acid, and Glauber's salt dissolved in tap water) was used. Desorption studies revealed that AR119 dye could be well removed from dye‐loaded adsorbent by 0.3 M NaOH solution.  相似文献   
90.
A tracer plume was created within a thin aquifer by injection for 299 d of two adjacent “sub‐plumes” to represent one type of plume heterogeneity encountered in practice. The plume was monitored by snapshot sampling of transects of fully screened wells. The mass injection rate and total mass injected were known. Using all wells in each transect (0.77 m well spacing, 1.4 points/m2 sampling density), the Theissen Polygon Method (TPM) yielded apparently accurate mass discharge (Md) estimates at three transects for 12 snapshots. When applied to hypothetical sparser transects using subsets of the wells with average spacing and sampling density from 1.55 to 5.39 m and 0.70 to 0.20 points/m2, respectively, the TPM accuracy depended on well spacing and location of the wells in the hypothesized transect with respect to the sub‐plumes. Potential error was relatively low when the well spacing was less than the widths of the sub‐plumes (>0.35 points/m2). Potential error increased for well spacing similar to or greater than the sub‐plume widths, or when less than 1% of the plume area was sampled. For low density sampling of laterally heterogeneous plumes, small changes in groundwater flow direction can lead to wide fluctuations in Md estimates by the TPM. However, sampling conducted when flow is known or likely to be in a preferred direction can potentially allow more useful comparisons of Md over multiyear time frames, such as required for performance evaluation of natural attenuation or engineered remediation systems.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号