首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   24篇
  免费   2篇
地球物理   3篇
地质学   23篇
  2016年   2篇
  2014年   2篇
  2013年   7篇
  2012年   3篇
  2011年   1篇
  2008年   1篇
  2006年   1篇
  2004年   3篇
  2003年   4篇
  2002年   1篇
  2001年   1篇
排序方式: 共有26条查询结果,搜索用时 15 毫秒
21.
Manganese‐ and iron‐rich materials are of major geoscientific and economic interest, many of which contain microscopic features that provide valuable information. To obtain accurate results, a homogeneous microanalytical reference material for calibration is needed. Several researchers have used the Mn‐ and Fe‐rich RMs, JMn‐1, NOD‐A‐1, NOD‐P‐1 and FeMn‐1, for this purpose; therefore, they were tested in this study to determine their suitability for microanalysis. Their homogeneity was investigated by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) with two different types of lasers (nano‐ and femtosecond), with spot and line scan analyses and with different operating parameters, such as spot size, pulse repetition rate and fluence. As the established manganese nodule RMs revealed inhomogeneities for picogram to microgram test portions, we also investigated the new synthetic Fe‐ and Mn‐rich RM, FeMnOx‐1. FeMnOx‐1 was found to be homogeneous for large (ø 40 μm: 2% RSD repeatability) and small (ø 8–10 μm: 10% RSD repeatability) spot sizes. This homogeneity is in the range of the homogeneous NIST SRM 610 and GSE‐1G reference glasses. Furthermore, FeMnOx‐1 revealed a large‐scale homogeneity within uncertainties of a few per cent, using test portions in the ng range, when measuring four individual mounts of this material.  相似文献   
22.
The transitional virtual geomagnetic poles (VGPs) of the five most detailed records lie within the longitudinal bands of America, western Europe and eastern Asia. This distribution does not support the hypothesis of a direct link with heterogeneities of the lower mantle underneath Americas and eastern Asia. A similar distribution of VGPs persists by adding less detailed records and show similarities with the distribution of maximum inclination anomalies predicted by time-averaged field models. However, the two databases are far too limited to infer any recurrence of non-dipole components during reversals. Clusters of VGPs are observed in most records at various geographical locations without preference for specific longitudes, which most likely result from intense volcanism during short time periods rather than from transitional dipolar states.  相似文献   
23.
Abstract

Abstract Time series analyses are applied to characterize the transient flow regimes of the Nam La cavern conduit, northwest Vietnam. The conduit transforms the input signal to an output signal, and the degree of transformation provides information on the nature of the flow system. The input for the analysis is net precipitation and the flow hydrograph at the cave entrance, while the output series is the flow hydrograph at the resurgence. Cross-correlation and cross-spectrum analysis are used to investigate the stationarity and linearity of the input–output transformation of the system, resulting in hydrodynamic properties such as system memory, response time, and mean delay between input and output. It is shown that during high flow periods, the flow in the conduit is pressurized. Consequently, the linear input–output assumption holds only for low flows. To highlight the hydrodynamics of the cavern conduit for the high flow periods, wavelet spectrum and wavelet cross-spectrum analyses are applied.  相似文献   
24.
Abstract

Two multi-tracer tests were performed in fissured rocks accessible in underground laboratories to examine a new fluorescent dye: pyrene-1,3,6,8-tetra sulphonic acid (PTS). The first test was carried out at the Lindau Rock Laboratory (LRL), Germany, in a highly permeable ore dike, and the second, at the Grimsel Test Site (GTS), Switzerland, in a heterogeneous granite fault zone (AU 126). At the LRL new tracer was injected together with uranine in a convergent flow field (monopole test), and slightly different tracer breakthrough curves were observed according to different diffusion coefficients of both tracers. The matrix porosity calculated with the aid of the one-dimensional (1-D) single-fissure dispersion model (SFDM) agrees well with that found in earlier tracer tests and with measurements performed on core samples. At the GTS, the PTS tracer was applied together with pyranine in two-well injection–withdrawal (dipole) tests. Both tracers yielded identical tracer concentration curves, which confirm their conservative behaviour. Mathematical simulations performed with the aid of a 3-D numerical model (FRAC3DVS) yielded equally good fits for different sets of parameters, independent of whether matrix porosity was included or neglected. That lack of unique solution and the difficulty in observing the influence of matrix diffusion result from a wide distribution of the transit times of particular streamlines, which is characteristic for injection–withdrawal tests. However, both tracer tests clearly indicated that the new tracer (PTS) behaves conservatively at high pH values and can be successfully used for groundwater labelling.  相似文献   
25.
This study reports precise and accurate data for rare earth elements (REE) measured on eight geological reference materials, five enriched in REE (BE‐N, BHVO‐2, BR, BR‐24 and RGM‐1) and three very depleted in REE (BIR‐1, UB‐N and DTS‐2). Data were acquired by quadrupole ICP‐MS after isolation of the REE using an ion‐exchange chromatography procedure. All the measured REE abundances were similar within ≈ 5% (10% for the most REE‐depleted sample DTS‐2) to the high‐quality measurements previously published in the literature. We also show that by using an internal Tm spike, the reproducibility of the data was improved to ~ 1%. Applying this technique to the analysis of ultra‐depleted rock samples (sub ng g?1), we show that significant improvements were obtained relative to the routine trace element measurement method. The chondrite‐normalised patterns were smooth instead of displaying irregularities. Although the classical method gives excellent results on REE‐rich samples, we believe that our technique improves the precision and accuracy of measurements for highly REE‐depleted rocks.  相似文献   
26.
A simple, single sample preparation involving pressed rock powder pellets was utilised to determine the trace and ultra trace abundances of petrogenetically important elements including high field‐strength elements and REEs by laser ablation‐ICP‐MS. One of the elements predetermined by XRF spectrometry served as an internal standard. The influence of sample preparation parameters (grain size, pellet compactness and amount of binding media) on analytical performance was also investigated, including sample homogeneity issues at the laser sampling scale. Line scanning with a high repetition frequency (20 Hz) and large beam diameter (200 μm) ensured ablation from a larger sample surface area, eliminating issues related to sample heterogeneity. A median grain size of about 10 μm for silicate rock powders was found to be sufficiently representative at this scale of laser sampling. Granitic rocks or samples containing resistant minerals such as zircon needed extra grinding to achieve grain sizes down to < 5 μm for better precision for elements that are concentrated in these phases. Using 137Ba as an internal standard, reasonable accuracies within 15–20% for most of the high mass trace elements were achieved; in the case of low mass elements, it may deviate up to 40%. Precision of measurements rarely exceeded 15% RSD.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号