首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   0篇
地球物理   25篇
  1967年   1篇
  1965年   1篇
  1963年   1篇
  1962年   4篇
  1961年   2篇
  1960年   3篇
  1959年   4篇
  1958年   2篇
  1957年   6篇
  1956年   1篇
排序方式: 共有25条查询结果,搜索用时 31 毫秒
1.
Summary The validity ofBoltzmann's energy distribution law as applied to the charge distribution of monodisperse aerosols, i.e. aerosols which contain particles of one size only, was studied with improved equipment now available.Since monodisperse aerosols with particle size of about 10–6 cm cannot yet be produced and because aerosols in general contain particles of different sizes, polydisperse aerosols stored in a large gasometer were used for the investigation. The composition and the average radius of these aerosols heterogeneous in particle size were determined by the Exhaustion Method employing a diffusion battery without end-pieces or connecting tubing.The experimental curve found for the ratio of the uncharged (N 0) to the charged (N) nuclei versus radius (r) of the particles deviates for all investigated radii between 0.5 and 4.0·10–6 cm from the theoretical curve of a monodisperse aerosol computed according to the Boltzmann law. For radii smaller than about 1.4·10–6 cmN 0/N is smaller than that given by Boltzmann's law, for radii greater than 1.4·10–6 cm larger, or, in other words, forr<1.4·10–6 cm the number of charged nuclei found in the aerosols investigated is greater than that predicted byBoltzmann's law, and forr>1.4·10–6 cm smaller.The deviations from the theoretical curve forr>1.4·10–6 cm can be fully explained by the polydispersity of the aerosols used; forr<1.4·10–6 cm the deviations are too big to be attributed to polydispersity. From this it must be concluded thatBoltzmann's distribution law is not valid for the charge distribution of homogenous aerosols containing nuclei with radii smaller than about 1.4·10–6 cm.The equivalent radius as deduced from a substitute monodisperse aerosol in charge equilibrium for which theBoltzmann law is assumed valid, deviates in the range of 1.0·10–6<r<3.0·10–6 cm (or 90%>100N 0/Z>55%) on the average by up to 35% from the actual mean radius of the investigated polydisperse aerosols computed from the radii of their singly sized components.
Zusammenfassung Die Gültigkeit desBoltzmannschen Gesetzes der Energieverteilung für die Ladungsverteilung von monodispersen Aerosolen, das heisst Aerosolen, welche Teilchen von nur einer Grösse enthalten, wurde mit den jetzt zur Verfügung stehenden verbesserten Mitteln studiert.Da monodisperse Aerosole mit Teilchengrössen von ungefähr 10–6 cm noch nicht erzeugt werden können und Aerosole im allgemeinen Teilchen von verschiedenen Grössen enthalten, wurden für die jetzige Untersuchung polydisperse Aerosole, welche in einem grossen Gasometer gespeichert waren, benützt. Die Zusammensetzung und der mittlere Radius dieser Aerosole mit heterogener Teilchengrösse wurden nach der Exhaustions-Methode unter Benützung einer Diffusionsbatterie ohne Endstücke oder Verbindungsröhren bestimmt.Die experimentell gefundene Kurve, welche das Verhältnis der ungeladenen (N 0) und geladenen (N) Kerne als Funktion des Radius (r) darstellt, weicht für alle untersuchten Radien zwischen 0.5 und 4.0·10–6 cm von der theoretischen Kurve eines monodispersen Aerosols, wie sie nachBoltzmann's Gesetz berechnet wird, ab. Für Radien kleiner als ungefähr 1.4·10–6 cm ist das VerhältnisN 0/N kleiner als es durchBoltzmann's Gesetz gegeben wird, für Radien grössen als 1.4·10–6 cm grösser oder, mit anderen Worten, fürr<1.4·10–6 cm ist die Zahl der geladenen Teilchen, die in den untersuchten Aerosolen gefunden wurde, grösser als die vonBoltzmann's Gesetz vorausgesagte, und fürr>1.4·10–6 cm kleiner.Die Abweichungen von der theoretischen Kurve fürr>1.4·10–6cm können vollkommen durch die Polydispersität der benützten Aerosole erklärt werden; fürr<1.4·10–6 cm sind die Abweichungen zu gross, als dass sie der Polydispersität zugeschrieben werden könnten. Daraus muss geschlossen werden, dassBoltzmann's Verteilungsgesetz für die Ladungsverteilung eines homogenen Aerosols, welches Kerne mit Radien kleiner als ungefähr 1.4·10–6 cm enthält, nicht gültig ist.Der äquivalente Radius, wie er von einem im Ladungsgleichgewicht befindlichen, monodispersen Ersatz-Aerosol, für welchesBoltzmann's Gesetz als gültig angenommen wird, abgeleitet werden kann, weicht im Bereich von 1.0·10–6<r<3.0·10–6 cm (oder 90%>N 0/Z>55%) durchschnittlich bis zu 35% vom tatsächlichen mittleren Radius des untersuchten polydispersen Aerosols ab.


The research reported in this article has been supported in part by the Geophysics Research Directorate of the Air Force Cambridge Research Laboratories, through the European Office of the Air Force Research Division, United States Air Force under Contract AF 61(052)-26, by the United States Department of Army, through its European Research Office, Contract DA-91-591-EUC-1282 & 1657 and by the Instrumentation Engineering Physics & Analysis Laboratory of the General Electric Co., Schenectady, New York under Retainer Agreement.  相似文献   
2.
Summary Comparisons were made of the extinctions as measured with a photoelectric condensation nucleus counter, Dublin School of Cosmic Physics Model 1957, when the «over-pressure method» or the «under-pressure method» with equal pressure expansion ratios were used for producing the adiabatic cooling of the sample in, the fogtube of the counter. Due to theSchlarb effect the extinction measured by the second method is smaller than that by the first. Tables and graphs for converting the extinction obtained by one method into that by the other are given. The advantages of the underpressure method are given and discussed.
Zusammenfassung Es wird über die Vergleichung der Extinktionen, welche mit einem photo-elektrischen Kondensationskernzähler Modell 1957 der Schule für kosmische Physik in Dublin gemessen werden, berichtet, wenn, bei gleichem Druckexpansions-Verhältnis, die Druckerhöhungs- oder die Expansionsmethode in ein partielles Vakuum für die Erzeugung der adiabatischen Abkühlung der im Nebelrohr des Kernzählers eingeschlossenen Aerosolprobe benützt wird. Wie erwartet, ist als Folge desSchlarb-Effektes die mit der zweiten Methode gemessene Extinktion kleiner. Tabellen und Kurven werden mitgeteilt, welche die Umwandlung der mit der einen Methode erhaltenen Extinktion in jene der anderen ermöglichen, und die Vorteile der Vakuum-Expansions-Methode diskutiert.


The research reported in this article has been supported in part by the Geophysics Research Directorate of the Air Force Cambridge Research Laboratories, through the European Office of the Air Research Division, United States Air Force under Contract AF 61 (052)-26 and by the Instrumentation Engineering Physics & Analysis Laboratory of the General Electric Co. Schenectady, New York under Retainer Agreement.  相似文献   
3.
Summary The modification of the dynamic method suggested permits determining the diffusion coefficient of an aerosol from two concentration measurements (Z v ) at the exit of a diffusion battery with different air-flows instead of measuring the concentration (Z) at the entrance and that (Z v ) at the exit as originally employed.
Zusammenfassung Die vorgeschlagene Modifikation der dynamischen Methode gestattet die Bestimmung des Diffusionskoeffizienten eines Aerosols aus zwei Konzentrationsmessungen (Z v ) am Ausgange der Diffusionbatterie mit verschiedenen Luftstromgeschwindigkeiten anstatt der Messung der Konzentrationen am Eingang (Z) und Ausgang (Z v ), wie in der ursprünglichen, Methode benützt.
  相似文献   
4.
Summary The effect on extinction of isothermal distillation, shrinking of the droplets by evaporation without recondensation of the liberated water vapour, coagulation and differential settling of the fog droplets which take place in the fog of a photo-electric nucleus counter and which can produce a small additional extinction («creep») in the first seconds after its formation, were numerically examined. The relative contribution of each process to the total creep observed is assessed. It is found that isothermal distillation can produce amounts of creep (up to 1.70%) which exceed considerably those caused by evaporation or coagulation. The results of these computations explain the occurrence of creep with concentrations greater than approx. 25 000 nuclei/cm3 in fog-tubes of 3.85 cm air-column diameter.That the disappearance of creep in fog-tubes of diameters 2.5 cm and less is due to the accelerated heat-flow from the walls of the narrow fog-tube was previously proved by reducing appropriately the diameter of the light pencil through the fog. In order to meet the objection that by restricting the cross section of the light pencil the fine structure of the fog comes into play, the increase in the travel time of the heat from the walls was achieved this time by using a photo-electric counter with a fog-tube of 8 cm diameter and a light beam of 2.8 cm diameter as in the «Standard Counter 1946». As expected, creep was found in every single measurement up to readings of 53%. Typical examples of the galvanometer pointer-movement and photographic records of the extinction during fog formation in such a wide fog-tube for readings between approx. 10 and 76% are given and their peculiarities discussed.The extinction over the range from 175 000 to 20 000 nuclei/cm3 was also measured with a red and a blue monochromatic interference filter and the results contrasted against the computed extinctions for these two wave lengths. It was ascertained that for the same number of nuclei the extinction for red light is in general larger than that for blue; the difference between the observed extinctions varies considerably, becoming zero or even negative. The most striking feature, however, is the different course of the extinction for the two wave lengths as a function of the number or size of the droplets.The size of the fog droplets in the counter was deduced from the extinction measurements for these two wave lengths and by collecting the falling droplets on coated slides. The radius of the droplets obtained by the optical method varies from 1.81 to 3.19 when the extinction decreases from 86 to 56%. The radius of the droplets as deduced from gelatine coated slides dyed with Naphtol Green B increases from 1.44 at 67.4% extinction (42 400 nuclei/cm3) to 6.30 at 15.6% (858 nuclei/cm3).
Zusammenfassung Der Einflus der isothermalen Destillation, des Einschrumpfens der Tröpfchen durch Verdunstung ohne Wiederkondensation des freiwerdenden Wasserdampfes, des Zusammenfliessens und Absetzens der Nebeltröpfchen auf die Extinktion, welche im Nebel des photo-elektrischen Kernzählers stattfinden und die in den ersten Sekunden nach seiner Bildung eine kleine zusätzliche Extinktion (im folgenden Kriechen genannt) erzeugen können, wurde numerisch geprüft. Der entsprechende Beitrag jedes einzelnen der oben genannten Prozesse zum Gesamtbetrag des beobachteten Kriechens wurde abgeschätzt. Es wurde gefunden, dass isothermale Destillation zusätzliche Extinktions-Beträge (bis zu 1.70%) erzeugen kann, welche jene durch Verdunstung oder Zusammenfliessen der Tröpfchen verursachten, beträchtlich übersteigen. Die Resultate dieser Berechnungen erklären das Auftreten des Kriechens bei Konzentrationen grösser als ca. 25 000 Kerne per cm3 in Nebelrohren von 3.85 cm Luftsäulen-Durchmesser.Dass das Verschwinden des Kriechens in Nebelrohren mit einem Durchmesser von 2.5 cm und weniger dem beschleunigten Wärmefluss von den Wänden des engen Nebelrohres zuzuschreiben ist, wurde früher durch eine entsprechende Verengung des Lichtbündels, welches zur Durchleuchtung des Nebels verwendet wird, bewiesen. Um dem Einwand zu begegnen, dass bei so starker Verkleinerung des Querschnittes des Lichtbündels, wie sie benützt wurde, schon die Feinstruktur des Nebels eine Rolle spielt, wurde diesmal die Verlängerung der Laufzeit der Wärme von den Wänden durch Erweiterung des Nebelrohres auf 8 cm Durchmesser erzielt, während der Durchmesser des Lichtbündels mit 2.8 cm — wie im «Standard photo-elektrischen Kernzähler 1946» — unverändert belassen wurde. Entsprechend den Erwartungen wurde bei jeder einzelnen Messung bis zu Lesungen von 53% Kriechen festgestellt. Typische Beispiele der Bewegung des Galvanometer-Zeigers und photographische Aufzeichnungen der Extinktion während der Nebelbildung in einem solchen weiten Nebelrohr werden für Lesungen zsischen ca. 10 und 76% gegeben und ihre Eigentümlichkeiten besprochen.Die Extinktion für Konzentrationen zwischen 175 000 und 20 000 Kernen per cm3 wurde auch mit einem roten und blauen Interferenz-Filter gemessen und die Resultate den für diese zwei Wellenlängen berechneten Extinktionen gegenübergestellt. Es wurde festgestellt, dass bei der gleichen Kernzahl die Extinktion für rotes Licht im allgemeinen grösser ist als jene für blaues; die Differenz zwischen den beobachteten Extinktionen schwankt beträchtlich, wird null oder sogar negativ. Am auffallendsten ist jedoch der verschiedene Verlauf der Extinktion für die zwei Wellenlängen als Funktion der Zahl oder Grösse der Tröpfchen.Die Grösse der Nebeltröpfchen im Nebelrohr des photo-elektrischen Kernzählers wurde aus den Extinktions-Messungen in diesen zwei Wellenlängen und durch Auffangen der fallenden Tröpfchen auf Mikroskop-Objektträgern und Deckgläsern, welche mit gefärbter Gelatine überzogen waren, bestimmt. Der Radius der Tröpfchen, welcher mittels der optischen Methode ermittelt wurde, liegt zwischen 1.81 und 3.19 , wenn die Extinktion von 86 auf 56% abnimmt.Der Tröpfchenradius, wie er aus den Flecken auf den Mikroskopgläschen, deren Gelatineüberzug mit Naphtol Grün B eingefärbt war, bestimmt wurde, wächst von 1.44 bei 67.4% Extinktion (42 400 Kerne per cm3) auf 6.30 bei 15.6% (858 Kerne per cm3).


The research reported in this article has been sponsored and supported in part by the Geophysics Research Directorate of the Air Force Cambridge Research Center, Air Research and Development Command, United States Air Force, under Contract AF 61(052)-26, through the European Office, ARDC in Brussels.  相似文献   
5.
Summary It is shown that the marked influence of the air-flow on the value of the diffusion coefficient as determined by the dynamic method can be fully explained when heterogeneity of the condensation nuclei in the aerosol is assumed. A theory of the dynamic method for heterogeneous aerosols is given on the assumption that the diffusion loss of a mixture of condensation nuclei of different diffusion coefficients is the sum of the diffusion losse of its components. Procedures for resolving heterogeneous aerosols into their components using the dynamic method are developed. The accuracy attainable by one of the methods which requires no assumptions on the number of components in the aerosol under investigation is illustrated by a numerical example.
Zusammenfassung Es wird gezeigt, dass der bemerkenswerte Einfluss der Luftstromgeschwindigkeit auf die Grösse des mit der dynamischen Methode bestimmten Diffusionskoeffizienten völlig erklärt werden kann, wenn Heterogenität der Kondensationskerne im Aerosol angenommen wird. Eine Theorie der dynamischen Methode für heterogene Aerosole wird unter der Annahme, dass der Diffusionsverlust eines Gemisches von Kondensationskernen mit verschiedenen Diffusionskoeffizienten gleich der Summe der Diffusionsverluste ihrer Komponenten ist, gegeben. Verfahren der Zerlegung heterogener Aerosole in ihre Komponenten mittels der dynamischen Methode werden entwickelt. Die mit einem der Verfahren, welches keine Annahme über die Zahl der in dem zu untersuchenden Aerosol vorhandenen Komponenten benötigt, erreichbare Genauigkeit wird an einem numerischen Beispiel illustriert.
  相似文献   
6.
Summary A cloud chamber for investigating the ice-forming properties of natural and artificial aerosols consisting of three adjacent compartments is described. Each compartment is a mixing-type cloud chamber, each held at a different preselected temperature. The sample to be examined is introduced simultaneously into all compartments and the crystals which form in the compartments, are recorded in a sugar solution. The temperature distribution in the compartments and the composition of the sugar solution are detailed. The connection between the temperature of the sugar solution for melting and growing of ice crystals and for self-crystalisation of the sugar solution and the concentration of the sugar solution is discussed. The measuring procedure is outlined and examples of counts of freezing nuclei in Dublin air are given.
Zusammenfassung Es wird eine Wolkenkammer zur Untersuchung der eisbildenden Eigenschaften natürlicher und künstlicher Aerosole beschrieben, welche aus drei angrenzenden Abteilen besteht. Jeder Abteil ist eine Mischwolkenkammer, welche auf einer vorher gewählten Temperatur gehalten wird. Die zu untersuchende Aerosolprobe wird gleichzeitig in alle Abteile, von denen jeder eineandere Temperatur hat, eingebracht und die sich bildenden Kristalle werden in einer Zuckerlösung registriert. Die Temperaturverteilung in den Abteilen und die Zusammensetzung der Zuckerlösung werden detailliert. Die Beziehung zwischen der Temperatur der Zuckerlösung für das Schmelzen und Wachsen der Eiskristalle und für die spontane Kristallisation der Zuckerlösung und der Konzentration der Zuckerlösung wird erörtert. Der Messvorgang wird skizziert und einige Resultate von Gefrierkernzählungen in Dublin werden mitgeteilt.


The research reported in this article has been supported and sponsored by the U.S. Department of Army, through its European Research Office under Contracts DA-91-591-EUC-1282 & 1657.  相似文献   
7.
Summary When dealing with the influence of pressure on the counting of condensation nuclei we have to distinguish between the influence of expansion ratio applied in the counting instrument and a phenomenon calledSchlarb effect according to which the counts of nuclei made at a reduced pressure are considerably lower than the expected concentration computed from the pressure ratio.Our investigation of the influence of overpressure (super-saturation) on the counting of nuclei by means of an Aitken type absolute counter with stereo-photomicrographic recording showed that the percentage number of droplets in the first shower decreases and in the subsequent showers increases when the overpressure decreases from 160 to 80 mm Hg. Furthermore, a reduction of overpressure from 160 to 80 mm corresponding to a reduction of pressure expansion ratio from 1.21 to 1.11 (or super-saturation from 345 to 195%), reduces the total counts on the average by 24%, in good agreement with findings byFoitzik in 1950 who used a large Scholz counter for his experiments.Regarding theSchlarb effect we found that the anomalies in measuring concentrations of condensation nuclei are considerable when the conditions are very different from those under which the calibration of a photo-electric counter was established. The percentage reduction of the expected concentration increases with decreasing pressure; it increases, in the average of all cases, from 30 to 58% when the pressure decreases from 600 to 200 mm Hg. At all pressures the reduction with small nuclei is somewhat bigger than with large nuclei, and with decreasing pressure the difference of the effect for small and large nuclei increases.Experiments with a big container of 283 litres in which the total loss due to diffusion and sedimentation during the experiments never exceeded 1% and no losses by fog formation during evacuation can occur, showed that the reduction produced by theSchlarb effect increases with increasing concentration when the pressure is lowered to half. The average percentage reduction of the expected concentration at 380 mm Hg was for concentrations of 70 to 410 nuclei/cm3 20% and for concentrations of 18900 to 4400 nuclei/cm3 52%.Our experiments proved also that at the lower pressure the nuclei not counted are present, but for some reason do not act as nuclei for condensation. The loss of 7% found may be attributed to unavoidable waste during evacuating the big container and subsequent filling it with filtered air.Of the two possible ways of eliminating theSchlarb pressure effect, only the one increasing the pressure with filtered air to a standard pressure of a large sample, quickly drawn into a big container, can be recommended. The other method, increasing the pressure in the fog-tube of a photo-electric counter which contains the nuclei sampled at lower pressure, must be rejected because the number of nuclei recovered after restoration of the initial pressure depends very much on the speed with which the lower pressure is raised to the initial pressure. The very different concentrations obtained are due to a different distribution of nucleus concentration and fog-density along the lightpath after expansion, which is caused by the different speed of the filtered air rushing-in and is difficult to control or standardize.
Zusammenfassung Bei der Untersuchung des Einflusses des Druckes auf die Zählung der Kondensations-Kerne haben wir zwei Fälle zu unterscheiden: den Einfluss des Expansionsverhältnisses im Kernzähler und ein Phänomen,Schlarb-Effekt, demzufolge die Zahl der Kerne, welche bei reduziertem Druck gefunden wird, beträchtlich kleiner ist, als man entsprechend dem Verhältnis der Drucke erwarten würde.Unsere Untersuchung des Einflusses des Überdruckes (der Übersättigung) auf die Zählung der Kerne mittels eines absoluten Kernzählers (vom Aitken Typus) mit mikrophotographischer Registrierung zeigte, dass die perzentuelle Zahl der Tröpfchen im ersten Schauer abnimmt und in den darauffolgenden Schauern zunimmt, wenn der Überdruck von 160 auf 80 mm Hg abnimmt. Eine Verminderung des Überdruckes von 160 auf 80 mm, welche einer Reduktion des Expansions-Druckverhältnisses von 1.21 auf 1.11 (oder der Übersättigung von 345 auf 195%) entspricht, setzt die Zahl der gemessenen Kerne im Mittel um 24% herab. Dies ist in guter Übereinstimmung mit den Befunden vonFoitzik im Jahre 1950, der für seine Experimente einen grossen Scholz Kernzähler verwendete.Bezüglich desSchlarb-Effekts fanden wir, dass die Abweichungen der gemessenen Konzentrationen von Kondensationskernen beträchtlich sind, wenn die Bedingungen, unter denen die Messungen angestellt werden, sehr verschieden sind von denen, unter welchen die Eichung des photo-elektrischen Kernzählers ausgeführt wurde. Die perzentuelle Herabsetzung der erwarteten Konzentration wächst mit abnehmendem Druck; sie wächst im Mittel aller Fälle von 30 auf 58%, wenn der Druck von 600 auf 200 mm Hg abnimmt. Bei allen Drucken ist die Verminderung etwas grösser bei kleinen Kernen als bei grossen, und mit abnehmendem Druck wächst die Differenz des Effekts für kleine und grosse Kerne.Wir haben ferner Experimente mit einem grossen Gefäss von 283 Litern Inhalt ausgeführt, in welchem die durch Diffusion und Sedimentation verursachten Gesamtverluste während unserer Experimente niemals 1% überstiegen haben und keine Verluste durch Nebelbildung während des Auspumpens vorgekommen sind. Die Resultate dieser Experimente zeigen, dass die durch denSchlarb-Effekt erzeugte Reduktion mit zunehmender Konzentration zunimmt, wenn der Druck auf die Hälfte gesenkt wird. Die mittlere perzentuelle Reduktion der erwarteten Konzentration betrug bei 380 mm Hg 20% für Konzentrationen zwischen 70 und 410 Kernen pro cm3, und 52% für solche von 18900 bis 44000 Kernen.Unsere Experimente haben bewiesen, dass bei niedrigerem Druck die nicht gezählten Kerne vorhanden sind, aber aus irgendwelchen Gründen nicht als Zentren der Kondensation wirken. Der gefundene Verlust von 7% kann wohl dem unvermeidlichen Schwund während der Auspumpens des grossen Gefässes und der nachträglichen Füllung mit filtrierter Luft zugeschrieben werden.Es gibt zwei Wege, den Druckeffekt nachSchlarb zu beseitigen: Der erste, der allein empfohlen werden kann, bringt den Druck einer grossen, rasch in ein Gefäss von beträchtlicher Grösse gesaugten Probe mittels filtrierter Luft auf Normaldruck. Der zweite, bei dem der Druck im Nebelrohr eines photo-elektrischen Kernzählers, welcher die bei niedrigerem Druck gesammelte Probe enthält, auf Normaldruck gebracht wird, muss abgelehnt werden, da die Zahl der Kerne, welche nach Wiederherstellung des Ausgangsdruckes gefunden werde, sehr von der Geschwindigkeit abhängt, mit der der niedrigere Druck auf den ursprünglichen gebracht wird. Die sehr verschiedenen Konzentrationen, welche erhalten werden, sind durch die verschiedene Verteilung der Kernkonzentration und daher der Nebeldichte entlang des Lichtstrahles nach der Expansion bedingt; diese komplizierte Verteilung der Nebeldichte ist durch die verschiedene Geschwindigkeit, mit der die filtrierte Luft ins Nebelrohr strömt, verursacht, welche sich schwer steuern oder standardisieren lässt.


The research reported in this article has been sponsored and supported in part by the Geophysics Research Directorate of the Air Force Cambridge Research Center, Air Research and Development Command, United States Air Force, under Contract No. AF 61 (052) - 26 and Supplemental Agreement Nos. 1 & 2, through the European Office, ARDC in Brussels.  相似文献   
8.
Summary Parallel measurements of the concentration of freezing nuclei and sea-salt particles carried out on the west coast of Ireland during summer 1958 to study the activity of sea-salt particles in the process of ice-nucleation of supercooled clouds are described and discussed. The results indicate that the concentration of freezing nuclei, active above –30°C, has no relationship to that of the sea-salt particles. A pronounced increase of the freezing nucleus concentration was observed during advection from the mainland showing that even under maritime conditions the most active freezing nuclei are particles of continental origin.
Zusammenfassung Es wird über parallele Messungen der Gefrierkerne und der Seesalzkerne berichtet, die im Sommer 1958 an der irischen Westküste durchgeführt wurden, um die Wirkung der Seesalzkerne für den Gefrierprozess in unterkühlten Wolken zu studieren. Die Ergebnisse zeigen, dass zwischen der Konzentration der im Temperaturbereich zwischen 0°C und –30°C aktiven Gefrierkerne und den Seesalzkernen keinerlei Beziehung besteht. Eine starke Erhöhung der Gefrierkernzahl bei Advektion von Aerosolen vom Festland deutet an, dass auch unter maritimen Bedingungen, Teilchen kontinentaler Herkunft besonders aktive Gefrierkerne sind.


Dedicated to Senior ProfessorL. W. Pollak, Ph. D., M.R.I.A. on his seventieth birthday.

The research reported in this article has been sponsored and supported in part by the Geophysics Research Directorate of the Air Force Cambridge Research Center. Air Research and Development Command, United States Air Force, under Contracts AF 61(052)-26 and AF 61(514)-927, through the European Office, ARDC in Brussels.  相似文献   
9.
Summary It was intended to carry out a detailed comparison between the values of the diffusion coefficient of condensation nuclei obtained by the static method and the corresponding values deduced from measurements by the dynamic method.In order to increase the accuracy of the diffusion coefficient as determined by the static method, using as decay vessel the fog tube of a photo-electric counter, it was necessary to develop a new version with an air column diameter smaller than that previously employed. Calibration curves for counters with fog tubes of 1.1, 1.9 and 2.5 cm diameter together with that for the standard of 3.85 cm are given.Fürth's theory of the static method was experimentally verified and shown to be consistent in itself.With regard to the dynamic method, the effect of varying the air-flow on the results obtained with the diffusion box was investigated and a marked influence on the value of the diffusion coefficient usingGormley's formula found. A regular and systematic increase of the diffusion coefficient with increase of air-flow, apparently overlooked up to now, was discovered. Within the range of 1 to 4 litres/min air-flow a change by 1 litre/min alters the diffusion coefficient by about 12%. Since for technical reasons during one experiment, adjustment of the air-flow by two litres/min were not uncommon hitherto, the diffusion coefficient determined in this way may be wrong by 25 % of its value for this reason alone. The influence of humidity on the diffusion coefficient determined with the diffusion box was also studied. It was found that the reduction of the diffusion coefficient due to increase in relative humidity from 53 % to 84 % amounts in the average and over a very wide range of diffusion coefficients to about 10 %.The comparison of the diffusion coefficients determined by the static and dynamic methods gave the following results: The diffusion coefficient of large hot nichrome wire nuclei (D 10 · 10–6 cm2/sec) determined by the static method is approximately one third of that obtained when the dynamic method with an air-flow of 1 litre/min is used. With decreasing size of nuclei the diffusion coefficients measured by the two methods approach each other.It is suggested that the observed discrepancies are due to a thin boundary layer which at the start of the diffusion process is almost free of nuclei. The theory of the static method is accordingly modified and a new formula for the calculation ofD is derived which leads to agreement between the static and the dynamic determinations ofD when it is assumed that the boundary layer has a thickness of about 1.5 mm.
Zusammenfassung Es war beabsichtigt, eine detailierte Vergleichung der mittels der statischen und dynamischen Methode gemessenen Diffusionskoeffizienten von Kondensationskernen durchzuführen.Um die Genauigkeit der mit der statischen Methode ermittelten Diffusionskoeffizienten, wenn das Nebelrohr des photoelektrischen Kernzählers als Kernspeicher benützt wird, zu erhöhen, war es notwendig ein neues Modell mit einer zylindrischen Nebelkammer von kleinerem Durchmesser, als bisher verwendet, zu entwickeln. Es werden Eichkurven für Zähler mit Nebelrohren von 1.1, 1.9 und 2.5 cm Durchmesser zusammen mit der Eichkurve für den Standard-Kernzähler von 3.85 cm Durchmesser gegeben.Fürth's Theorie der statischen Methode wurde experimentell verifiziert und als in sich selbst verträglich bewiesen.Es wurde ferner der Effekt der änderung des Luftstromes durch den Diffusions-apparat auf die mit der dynamischen Methode bestimmten Diffusionskoeffizienten untersucht, und ein bemerkenswerter Einfluss der Luftstromgeschwindigkeit auf die Grösse des Diffusionskoeffizienten entdeckt, wennGormley's Formel der Auswertung zu Grunde gelegt wird. Ein regelmässiges und systematisches Anwachsen des Diffusionskoeffizienten mit Zunahme der Luftströmung — offenbar bis jetzt übersehen — wurde festgestellt. Für Luftströmungen zwischen 1 und 4 Liter/Min bewirkt eine änderung der Luftströmung um 1 Liter/Min eine änderung des Diffusionskoeffizienten um etwa 12%. Da bisher aus technischen Gründen eine Regulierung des Luftstromes um 2 Liter/Min während eines und desselben Experiments nichts Ungewöhnliches war, so kann deshalb allein der so bestimmte Diffusionskoeffizient um 25 % seines Wertes unrichtig sein. — Auch der Einfluss der Feuchtigkeit auf den mit dem Diffusionsapparat ermittelten Diffusionskoeffizienten wurde geprüft. Es wurde festgestellt, dass die Reduktion des Diffusionskoeffizienten als Folge einer Erhöhung der relativen Feuchtigkeit von 53 auf 84 % im Durchschnitt und für Diffusionskoeffizienten bis zu 500. 10–6 cm2/sec etwa 10 % beträgt.Die Vergleichung der mittels der statischen und dynamischen Methode gemessenen Diffusionskoeffizienten ergab das folgende Resultat: Der Diffusionskoeffizient grosser,. durch elektrisches Glühen eines Drahtes erzeugten Kondensationskerne (D 10. 10–6 cm2/sec), wenn mit der statischen Methode bestimmt, ist ungefähr ein Drittel jenes mittels der dynamischen Methode gemessenen Wertes bei einem Luftstrom von 1 Liter/Min durch den Diffusionsapparat. Mit abnehmender Grösse der Kondensationskerne nähern sich die Werte der nach den beiden Methoden bestimmten Diffusionskoeffizienten.Es wird versucht, die beobachteten Unstimmigkeiten durch die Annahme einer dünnen Wandschicht zu erklären, die zu Beginn des Diffusionsprozesses beinahe frei. von Kernen ist. Die Theorie der statischen Methode wurde dementsprechend abgeändert und eine neue Formel für die Berechnung vonD abgeleitet, die zu einer Uebereinstimmung zwischen den statischen und dynamischen Bestimmungen vonD führt, wenn angenommen wird, dass die Wandschicht eine Dicke von ungefähr 1.5 mm hat.
  相似文献   
10.
Summary A Verzár condensation nucleus counter with automatic recording was tested under constant and controlled conditions in the laboratory and compared with the standard photo-electric nucleus counter of high precision of the School of Cosmic Physics. The photographic records of the fog formation in the cylindrical cloud chamber of theVerzár automat made with galvanometers of 0.019 sec and 1.0 sec periods show that a galvanometer of 1 sec period cannot follow the rapid formation and disappearance of the fog, apparently due to the horizontal arrangement of the fog tube and the absence of an insulating wet lining.TheVerzár automat is an excellent apparatus for continuously recording concentration of condensation nuclei. Its calibration curve, however, would require adjustment if the photo-electric nucleus counter of the School of Cosmic Physics in Dublin were accepted as standard. A new calibration curve deduced from the Dublin comparisons made so far is given.
Zusammenfassung Ein Kondensationskernzähler mit automatischer Registrierung nachF. Verzár wurde im Laboratorium unter konstanten und gesteuerten Bedingungen geprüft und mit einem photo-elektrischen Kernzähler hoher Präzision, dem Standard der School of Cosmic Physics, verglichen. Die photographischen Aufzeichnungen der Nebelbildung in der zylindrischen Nebelkammer desVerzárschen Automaten, welche mit Galvanometern von 0.019 sec und 1.0 sec gemacht wurden, zeigen, dass ein Galvanometer mit einer Periode von 1 sec der raschen Bildung und Auflösung des Nebels nicht folgen kann, offenkundig durch die horizontale Anordnung des Nebelrohres und das Fehlen jeglicher Auskeidung mit feuchtem Isolationsmaterial bedingt.DerVerzársche Automat ist ein ausgezeichnetes Gerät für die fortlaufende Registrierung der Kernzahl. Seine Eichkurve bedarf jedoch einer Abänderung, falls der photo-elektrische Kernzähler der School of Cosmic Physics in Dublin als Standard angenommen wird. Eine neue Eichkurve, welche sich auf die bisher in Dublin gemachten Vergleichungen stützt, wird reproduziert.
  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号