首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   3篇
地球物理   5篇
地质学   2篇
  2022年   2篇
  2019年   1篇
  2016年   1篇
  2015年   1篇
  2014年   1篇
  2012年   1篇
排序方式: 共有7条查询结果,搜索用时 515 毫秒
1
1.
Tracy  Andrew  Javernick-Will  Amy  Liel  Abbie 《Natural Hazards》2022,114(1):183-204
Natural Hazards - The central USA has experienced an increase in the frequency and magnitude of human-induced earthquakes. The earthquakes are caused by the deep-well injection of water produced...  相似文献   
2.
Lochhead  Meredith  Goldwyn  Briar  Venable  Casie  Liel  Abbie B.  Javernick-Will  Amy 《Natural Hazards》2022,112(2):1165-1189

This study assesses the wind performance of various housing typologies representing informal construction practices in Puerto Rico to suggest modifications to enhance housing resilience in hurricanes. Based on fieldwork and interviews, the study defined four base housing typologies and possible variations in design and construction details. Each house was assessed using performance-based static wind analysis of potentially critical components. The results show that the initial governing failure mode in all base house typologies considered is roof panel loss due to tear-through at the fasteners, with subsequent governing failures being panel loss due to failures at the purlin-to-truss connections and failures of the truss-to-wall connections. In-plane wall failures and masonry uplift failures were both found to occur at much higher wind speeds than roof failures. To improve the hurricane performance, several feasible modifications are suggested, including installing hurricane straps at both the truss-to-wall and the purlin-to-truss connections, as well as improving the panel-fastener interface. In the construction of new roofs, this study found that using reduced spacing between roof members, hip roofs instead of gable roofs, and higher roof slopes leads to improved performance. These recommendations can make houses built through informal construction processes safer and more resilient to hurricanes as a form of climate adaptation.

  相似文献   
3.
Forward directivity may cause large velocity pulses in ground motion time histories that are damaging to buildings at sites close to faults, potentially increasing seismic collapse risk. This study quantifies the effects of forward directivity on collapse risk through incremental dynamic analysis of building simulation models that are capable of capturing the key aspects of strength and stiffness degradation associated with structural collapse. The paper also describes a method for incorporating the effects of near-fault directivity in probabilistic assessment of seismic collapse risk. The analysis is based on a suite of RC frame models that represent both past and present building code provisions, subjected to a database of near-fault, pulse-like ground motions with varying pulse periods. Results show that the predicted collapse capacity is strongly influenced by variations in pulse period and building ductility; pulse periods that are longer than the first-mode elastic building period tend to be the most damaging. A detailed assessment of seismic collapse risk shows that the predicted probability of collapse in 50 years for modern concrete buildings at a representative near-fault site is approximately 6%, which is significantly higher than the 1% probability in the far-field region targeted by current seismic design maps in the US. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
4.
In a seismically active region, structures may be subjected to multiple earthquakes, due to mainshock–aftershock phenomena or other sequences, leaving no time for repair or retrofit between the events. This study quantifies the aftershock vulnerability of four modern ductile reinforced concrete (RC) framed buildings in California by conducting incremental dynamic analysis of nonlinear MDOF analytical models. Based on the nonlinear dynamic analysis results, collapse and damage fragility curves are generated for intact and damaged buildings. If the building is not severely damaged in the mainshock, its collapse capacity is unaffected in the aftershock. However, if the building is extensively damaged in the mainshock, there is a significant reduction in its collapse capacity in the aftershock. For example, if an RC frame experiences 4% or more interstory drift in the mainshock, the median capacity to resist aftershock shaking is reduced by about 40%. The study also evaluates the effectiveness of different measures of physical damage observed in the mainshock‐damaged buildings for predicting the reduction in collapse capacity of the damaged building in subsequent aftershocks. These physical damage indicators for the building are chosen such that they quantify the qualitative red tagging (unsafe for occupation) criteria employed in post‐earthquake evaluation of RC frames. The results indicated that damage indicators related to the drift experienced by the damaged building best predicted the reduced aftershock collapse capacities for these ductile structures. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   
5.
While many cases of structural damage in past earthquakes have been attributed to strong vertical ground shaking, our understanding of vertical seismic load effects and their influence on collapse mechanisms of buildings is limited. This study quantifies ground motion parameters that are capable of predicting trends in building collapse because of vertical shaking, identifies the types of buildings that are most likely affected by strong vertical ground motions, and investigates the relationship between element level responses and structural collapse under multi‐directional shaking. To do so, two sets of incremental dynamic analyses (IDA) are run on five nonlinear building models of varying height, geometry, and design era. The first IDA is run using the horizontal component alone; the second IDA applies the vertical and horizontal motions simultaneously. When ground motion parameters are considered independently, acceleration‐based measures of the vertical shaking best predict trends in building collapse associated with vertical shaking. When multiple parameters are considered, Housner intensity (SI), computed as a ratio between vertical and horizontal components of a record (SIV/SIH), predicts the significance of vertical shaking for collapse. The building with extensive structural cantilevered members is the most influenced by vertical ground shaking, but all frame structures (with either flexural and shear critical columns) are impacted. In addition, the load effect from vertical ground motions is found to be significantly larger than the nominal value used in US building design. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
6.
Activities related to oil and gas production, especially deep disposal of wastewater, have led to sequences of induced earthquakes in the central United States. This study aims to quantify damage to and seismic losses for light-frame wood buildings when subjected to sequences of induced, small to moderate magnitude, events. To conduct this investigation, one- and two-story multifamily wood frame buildings are designed, and their seismic response dynamically simulated using three-dimensional nonlinear models, subjected to ground motion sequences recorded in induced events. Damage is quantified through seismic losses, which are estimated using the FEMA P-58 methodology. Results show that at levels of shaking experienced in recent earthquakes, minor damage, consisting of cracking of interior finishes and nonstructural damage to plumbing and heating, ventilation, and air conditioning systems, is expected, which is consistent with observed damage in these events. The study also examines how expected losses and building fragility will accumulate and/or change over a sequence of earthquakes. Results indicate that damage quantified in terms of absorbed hysteretic energy tended to accumulate over the sequences; this damage corresponds to elongation or widening of cracks. However, fragility is not significantly altered by damage in a preceding event, meaning structures are not becoming more vulnerable due to existing damage. In addition, sequences of events do not change losses if the building is only repaired once at the end of the sequence, as the worsening of damage does not alter repair actions. If repairs are conducted after each event, though, total seismic losses can increase greatly from the sequence.  相似文献   
7.
Seismic ground motions induce torsional responses in buildings that can be difficult to predict. To compensate for this, most modern building codes require the consideration of accidental torsion when computing design earthquake forces. This study evaluates the influence of ASCE/SEI 7 accidental torsion seismic design requirements on the performance of 230 archetypical buildings that are designed with and without accidental torsion design provisions, taking building collapse capacity as the performance metric. The test case archetypes include a broad range of heights, gravity load levels, and plan configurations. Results show that the ASCE/SEI 7 accidental torsion provisions lead to significant changes in collapse capacity for buildings that are very torsionally flexible or asymmetric. However, only inconsequential changes in collapse capacity are observed in the buildings that are both torsionally stiff and regular in plan. Therefore, the study concludes that accidental torsion provisions are not necessary for seismic design of buildings without excessive torsional flexibility or asymmetry. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号