首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   163篇
  免费   19篇
  国内免费   2篇
地球物理   172篇
地质学   12篇
  2022年   1篇
  2021年   4篇
  2020年   4篇
  2019年   3篇
  2018年   3篇
  2017年   2篇
  2015年   3篇
  2014年   4篇
  2013年   3篇
  2012年   9篇
  2011年   17篇
  2010年   6篇
  2009年   8篇
  2008年   16篇
  2007年   16篇
  2006年   13篇
  2005年   14篇
  2004年   6篇
  2003年   16篇
  2002年   8篇
  2001年   6篇
  2000年   4篇
  1999年   5篇
  1998年   2篇
  1997年   5篇
  1996年   4篇
  1992年   1篇
  1991年   1篇
排序方式: 共有184条查询结果,搜索用时 15 毫秒
1.
A seismic nonlinear time-history analysis was made for four-, six-, and eight-storey reinforced concrete buildings. These buildings were made as three-dimensional space frame structures with shear walls in both orthogonal directions. They have five bays with 4.8 m spacing each in the horizontal direction, and three bays with 4.2 m spacing each in the transversal direction. The frames were designed according to the Jordanian Seismic Code of practice for Seismic Zones 4, 3, 2, and 1 as proposed for Jordan by several authors. Time-history analysis was made using the El Centro (N-S) earthquake record of May 1940 as an actual earthquake excitation. The response reduction factor (R) that primarily consists of two factors that are the ductility reduction (Rµ) and the overstrength (), is obtained. It has been seen that the seismic zoning has a slight effect on the ductility reduction factor for different buildings, since it ranges from Zone 4 to Zone 1 as 2.37 to 2.52, 1.72 to 1.78, and 1.14 to 1.18 for four-, six-, and eight-storey buildings, respectively. Moreover, it is observed that, for different buildings and different seismic zones, the ductility reduction factor (Rµ) is slightly different from the system ductility factor (µ) especially for higher values of µ (i.e., Rµ µ). The response reduction factor, called overstrength (), was evaluated. The overstrength factor was found to vary with seismic zones (Z) , number of stories, and design gravity loads. However, the dependency on seismic zones was the strongest. The average overstrength of these buildings in Zones 4 and 1 was 2.61 and 6.94, respectively. The overstrength increased as the number of storeys decreased: overstrength of a four-storey building was higher than an eight-storey building by 36% in Zone 4, and 39% in Zone 1. Furthermore, buildings of the three heights had an average overstrength 165.9% higher in Zone 1 than in Zone 4. These observations have a significant implications for the seismic design codes which currently do not take into account the variation of the response reduction factor, R (i.e., ductility reduction factor times overstrength).  相似文献   
2.
The response of low‐ductility reinforced concrete (RC) frames, designed typically for a non‐seismic region, subjected to two frequencies of base excitations is studied. Five half‐scaled, two‐bay, two‐storey, RC frames, each approximately 5 m wide by 3.3 m high, were subjected to both horizontal and/or vertical base excitations with a frequency of 40 Hz as well as a lower frequency of about 4 Hz (close to the fundamental frequency) using a shake table. The imposed acceleration amplitude ranged from 0.2 to 1.2g. The test results showed that the response characteristics of the structures differed under high‐ and low‐frequency excitations. The frames were able to sustain high‐frequency excitations without damage but were inadequate for low‐frequency excitations, even though the frames exhibited some ductility. Linear‐elastic time‐history analysis can predict reasonably well the structural response under high‐frequency excitations. As the frames were not designed for seismic loads, the reinforcement detailing may not have been adequate, based on the crack pattern observed. The effect of vertical excitation can cause significant additional forces in the columns and moment reversals in the beams. The ‘strong‐column, weak‐beam’ approach for lateral load RC frame design is supported by experimental observations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   
3.
Energy serves as an alternative index to response quantities like force or displacement to include the duration‐related seismic damage effect. A procedure to evaluate the absorbed energy in a multistorey frame from energy spectra was developed. For low‐ to medium‐rise frames, it required a static pushover analysis of the structure to determine the modal yield force and ductility factor of an equivalent single‐degree‐of‐freedom system for the first two modes. The energy spectra were then used to determine the energy contribution of each mode. A procedure was also developed to distribute the energy along the frame height based on energy shapes. This study showed that the second‐mode response in some cases needs to be considered to reflect the energy (or damage) concentration in the upper floors. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   
4.
对目前岩石“全曲线”测试的若干看法   总被引:1,自引:0,他引:1  
从电液伺服岩石压力试验机工作机理的角度,对目前岩石应力-应变全过程曲线(以下简称“全曲线”)测试中的一些问题进行了分析,提出了自己的看法,目的是为了解决“全曲线”测试的2个问题,即如何测出“全曲线”;如何使测出的“全曲线”真实反映岩石的力学特性,并将其用到工程中。  相似文献   
5.
Introduction Estimation of an attenuation relationship for strong ground motion parameters has been an interesting research subject in the field of engineering seismology and has played a very important role in seismic safety evaluation, seismic zoning, seismic hazard evaluation of major constructions, etc. At present, the generally used parameters include peak acceleration, peak velocity and elastic response spectrum. Such parameters mentioned above are essentially independent of the duration…  相似文献   
6.
本文提出用累积延性系数评价底层柔性结构的底层需求变形能力,并根据地震时能量守恒关系推导了底层需求变形能力计算公式,然后对多质点体系使用实际地震加速度记录进行弹塑性响应分析,并与上述公式的计算结果进行比较。结果表明,本文提出的计算公式能够较好并安全地预测底层柔性结构的需求变形能力。  相似文献   
7.
FRP约束混凝土柱抗震性能若干问题的探讨   总被引:3,自引:0,他引:3  
基于实验研究和理论分析结果,对纤维增强复合材料(FRP)约束混凝土柱抗震性能研究中存在的若干关键问题进行了探讨,包括FRP约束混凝土构件在往复荷载作用下的受力特点、破坏特征、荷载-位移关系、弯矩-曲率关系、耗能及延性变化规律等,最后重点探讨了FRP约束混凝土柱在往复荷载作用下的刚度特性。  相似文献   
8.
钢-混凝土组合剪力墙抗震性能研究简述   总被引:18,自引:4,他引:14  
钢-混凝土组合剪力墙可以充分发挥钢和混凝土2种材料的优势,改善传统钢筋混凝土剪力墙延性和耗能能力较差的缺点,在钢-混凝土混合结构中具有应用优势。本文简要介绍了国内外一些新型的钢-混凝土组合剪力墙,并简述了其抗震性能的研究现状,最后对一些关键问题进行了初步探讨。  相似文献   
9.
超高强混凝土短柱抗震性能的试验研究   总被引:4,自引:0,他引:4  
通过对12根剪跨比λ=2.0的超高强混凝土短柱在低周反复荷载下抗震性能的试验研究,分析了其破坏形态,并研究了轴压比和配箍率对试件滞回特性和抗震延性的影响,提出了满足一定延性要求(μ△≥3.0)超高强混凝土短柱的轴压比限值和箍筋加密区的最小配箍特征值的建议值。该值可为现行规范的修订提供参考。  相似文献   
10.
1 Introduction Structural retro?t techniques (Roberts, 2005), such as restrainers, concrete shear keys, steel jackets, CFRPshells, base isolators, or dampers have been widely studied and implemented in actual structures based on the experiences learned from past earthquakes. In the Chi-Chi earthquake (EERI, 2001), the damage to simply-supported PCI girder bridges provided a different view from which to examine the function of a rubber bearing system for simply- supported bridges (NCREE,…  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号