Validation of Ground-Based Visible Measurements of Total Ozone by Comparison with Dobson and Brewer Spectrophotometers
Authors:M Van Roozendael  P Peeters  H K Roscoe  H De Backer  A E Jones  L Bartlett  G Vaughan  F Goutail  J-P Pommereau  E Kyro  C Wahlstrom  G Braathen  P C Simon
Institution:(1) Belgian Institute for Space Aeronomy, 3 Av. Circulaire, B-1180 Brussels, Belgium;(2) Koninklijk Meteorologisch Instituut, 3 Av. Circulaire, B-1180 Brussels, Belgium;(3) British Antarctic Survey, Madingley Rd., Cambridge, U.K.;(4) Physics Dept., University of Wales, Aberystwyth, U.K.;(5) Service d'Aéronomie du CNRS, BP3, 91371 Verrières-le-Buisson, France;(6) Finnish Meteorological Institute, Sodankylä Observatory, SF-99600 Sodankylä, Finland;(7) NILU, PO Box 100, N-2007 Kjeller, Norway
Abstract:Comparisons of total column ozone measurements from Dobson, Brewer and SAOZ instruments are presented for the period 1990 to 1995 at seven stations covering the mid- and the high northern latitudes, as well as the Antarctic region. The main purpose of these comparisons is to assess, by reference to the well established Dobson network, the accuracy of the zenith-sky visible spectroscopy for the measurement of total ozone. The strengths and present limitations of this latter technique are investigated. As a general result, the different instruments are found to agree within a few percent at all stations, the best agreement being obtained at mid-latitudes. On average, for the mid-latitudes, SAOZ O3 measurements are approximately 2% higher than Dobson ones, with a scatter of about 5%. At higher latitudes, both scatter and systematic deviation tend to increase. In all cases, the relative differences between SAOZ and Dobson or Brewer column ozone are characterised by a significant seasonal signal, the amplitude of which increases from about 2.5% at mid-latitude to a maximum of 7.5% at Faraday, Antarctica. Although it introduces a significant contribution to the seasonality at high latitude, the temperature sensitivity of the O3 absorption coefficients of the Dobson and Brewer instruments is shown to be too small to account for the observed SAOZ/Dobson differences. Except for Faraday, these differences can however be largely reduced if SAOZ AMFs are calculated with realistic climatological profiles of ozone, pressure and temperature. Other sources of uncertainties that might affect the comparison are investigated. Evidence is found that the differences in the air masses sampled by the SAOZ and the other instruments contribute significantly to the scatter, and the impact of the tropospheric clouds on SAOZ measurements is displayed.
Keywords:stratosphere  ozone  validation
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号