首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A critique of the internal tracer method for estimating contaminant degradation rates
Authors:Martian Peter  Sorenson Kent S  Peterson Lance N
Institution:Idaho National Engineering and Environmental Laboratory, P.O. Box 1625, Idaho Falls, ID 83415;Northwind Environmental Inc., P.O. Box 51174, Idaho Falls, ID 83402
Abstract:The internal tracer method for estimating contaminant degradation rates separates the attenuation effects not associated with degradation by using a codisposed recalcitrant internal tracer to normalize the degrading contaminant concentration. The remaining attenuation between the internal tracer and degrading contaminant is attributed to degradation and the degradation rate half-life is estimated from the first-order decay equation. An analytical solution of the advection- dispersion equation was used to evaluate flow-and-transport conditions that could result in incorrect estimates of contaminant degradation rate constants. Flow-and-transport characteristics that result in overestimating degradation rates were of particular interest because the internal tracer method often used to demonstrate natural attenuation can achieve remedial objectives. The analytical solution was also used to estimate the magnitude of error associated with using the internal tracer method at an example site and to explain different degradation rates estimated using tracers with different decay rate constants.
Keywords:
本文献已被 PubMed 等数据库收录!