Field Measurement of Suction, Water Content, and Water Permeability
Authors:Alessandro Tarantino  Andrew M Ridley  David G Toll
Institution:(1) Dipartimento di Ingegneria Meccanica e Strutturale, Università degli Studi di Trento, Via Mesiano, 77, 38050 Trento, Italy;(2) Geotechnical Observations Limited, London, UK;(3) School of Engineering, University of Durham, Durham, UK
Abstract:This paper presents a review of techniques for field measurement of suction, water content, and water hydraulic conductivity (permeability). Main problems in the use of field tensiometers are addressed and hints on how to improve tensiometer performance are given. Advantages and limitations of instruments for indirect measurement of suction including electrical conductivity sensors, thermal conductivity sensors, dielectric permittivity sensors, filter paper, and psychrometer are discussed. Techniques for water content measurement based on dielectric methods are then presented. These include time and amplitude domain reflectometry and capacitance. Finally, a brief overview of methods for measurement of water permeability in the field is presented.
Keywords:Field monitoring  Partially saturated soil  Suction  Water content  Tensiometer  Porous block sensors  Psychrometer  Filter paper  TDR sensor  ADR sensor  Capacitance sensor