首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Microcones configured with full-bridge circuits
Institution:1. Snow and Avalanche Study Establishment (SASE), Chandigarh (UT) -160036, India;2. National Institute of Technology (NIT), Kurukshetra (HR) - 136119, India;3. HQ- Snow and Avalanche Study Establishment, Manali (HP) -175103, India;1. Departamento de Solos, Universidade Federal de Viçosa, Viçosa, Brazil;2. Departamento de Ciências Agrárias e Ambientais, Universidade Estadual de Santa Cruz, Ilhéus, Brazil;3. Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil;4. Department of Soil Science, University of Wisconsin, Madison, United States;1. School of Resource and Environmental Management, Simon Fraser University, Burnaby B.C., Canada;2. WSL Institute for Snow and Avalanche Research SLF, Davos, Switzerland
Abstract:Small-diameter microcones have been widely used for the characterisation of soil properties in the field and in the calibration chamber because the smaller probe may require a smaller penetrometer capacity and a smaller calibration chamber. As the cone size decreases, the area required for the installation of the strain gauges also decreases, and thus, the half-bridge circuit has been generally adopted. The objective of this study is the development and application of a microcone configured with a full-bridge circuit instead of the half-bridge circuit for the measurement of the cone tip resistance and sleeve friction. The diameter of the microcone is designed to be D=15 mm, and thus, the projected area is 1.76 cm2. The full-bridge circuit in the microcone is configured by extending the rod behind the connection part for the installation of four strain gauges. Two strain gauges are installed in the loading part, and two strain gauges are installed in the extended rod. In addition, the half-bridge circuit is also used for comparison of the cone tip resistance and sleeve friction in both circuits. The advantages of the microcone with the extended rod are verified through a theoretical background study and through experimental studies of various parameters, including temperature calibration, stress calibration, and densification monitoring. The test results show that the extended rod-type microcone with a full-bridge is less affected by environmental effects and produces better linearity between the output voltage and the stress. In addition, the full-bridge circuit yields more reasonable and reliable cone tip resistance and sleeve friction values than the half-bridge circuit. This study demonstrates that the extended rod-type microcone may be an alternative choice for the configuration of the full-bridge for better resistance measurements.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号