首页 | 本学科首页   官方微博 | 高级检索  
     检索      

自动气象站蒸发示值重复性指标及校准方法研究
引用本文:陈利娟,张天华,陈涛,李晓红,张虎.自动气象站蒸发示值重复性指标及校准方法研究[J].气象科技,2015,43(3):430-433.
作者姓名:陈利娟  张天华  陈涛  李晓红  张虎
作者单位:四川省气象局探测技术中心,成都 610031,河南省气象信息网络与技术保障中心,郑州 450003,四川省气象局探测技术中心,成都 610031,四川省气象局探测技术中心,成都 610031,四川省气象局探测技术中心,成都 610031
基金项目:移动气象计量检定校准核查技术集成(CMAGJ2012Z11)项目资助
摘    要:四川省气象自动站蒸发要素校准工作中示值波动过大的情况时有发生,误差时而满足校准规范要求,时而不满足规范要求,导致校准数据的重复性较差,面对这种情况,按照中国气象局监测网络司发行的自动气象站现场校准方法(试行),难以对测量系统计量性能指标的符合性做出判定。通过查阅JJF1001-2011《通用计量术语及定义》、JJF1126—2004《超声波测厚仪校准规范》等相关资料,得出规定测量系统的示值重复性即可解决这一技术难题,并且通过大量试验及工作经验得出了示值重复性指标及其校准方法,为自动站蒸发系统现场校准规范的制定提供了有力的理论依据。

关 键 词:自动气象站  蒸发  示值重复性  校准方法
收稿时间:5/5/2014 12:00:00 AM
修稿时间:2014/9/16 0:00:00

Repeatability Index and Calibration Method of Evaporation Indications of Automatic Weather Stations
Chen Lijuan,Zhang Tianhu,Chen Tao,Li Xiaohong and Zhang Hu.Repeatability Index and Calibration Method of Evaporation Indications of Automatic Weather Stations[J].Meteorological Science and Technology,2015,43(3):430-433.
Authors:Chen Lijuan  Zhang Tianhu  Chen Tao  Li Xiaohong and Zhang Hu
Institution:Chen Lijuan;Zhang Tianhua;Chen Tao;Li Xiaohong;Zhang Hu;Sichuan Provincial Atmosphere Observation Centre;Henan Provincial Meteorological Information Network and Technology Support Centre;
Abstract:The over fluctuation of indication often occurs when calibrating evaporating sensors of automatic weather stations in Sichuan Province. The measured errors can meet the requirement of the calibration specification at one time and cannot the other time, which result in poor repeatability of calibration data. Regarding such situation, it is hard to judge the quantification index of the measuring system on the basis of the field trial use calibration method of automatic weather stations published by the Department of Observation and Telecommunication, CMA. In accordance with JJF 1001 2011 General Measuring Terminology and Definition and JJF 1126 2004 Specifications for Calibration of Ultrasonic Thickness Gauge, etc., this technical problem can be solved by specifying the indication repeatability of the measuring system. Based on a great number of experiments and work experiences, the repeatability index and calibration method of the evaporation indications are developed, which provides theoretical reference for making specifications for the on site calibration for the evaporating measuring system of automatic weather stations.
Keywords:automatic weather station  evaporation  repeatability  calibration method
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《气象科技》浏览原始摘要信息
点击此处可从《气象科技》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号