摘    要:本文运用平面二维数学模型,计算和分析了福建漳州后石电厂在不同将机容量、各种工况和潮型条件下受纳水体温度场的时空变化。从取取水口温升以及环境容量方面考虑,几个方案均满足要求。设计单位根据水口降温、环境容量要求和工程造价三方面综合比较后,可从中以一个。

关 键 词:温排水  数学模型  发电厂  水体温度  海水  海域

Numerical model for cooling water drainage in Zhangzhou Houshi Power Plant
Xu Xiao, Kuang Chuiping and Gu Jie.Numerical model for cooling water drainage in Zhangzhou Houshi Power Plant[J].Journal of Oceanography In Taiwan Strait,1998,17(2):195-200.
Authors:Xu Xiao  Kuang Chuiping and Gu Jie
Abstract:In this paper two models are used to calculate and analyze the time and space variation ofthe field of temperature in cooling water drainage under different installeation capacities,working conditions and tidal conditions around Zhangzhou Houshi Power Plant, FujianProvince. ConsideratioI's upon temperature rise at water intake and environmental capacityhave demonstrated that various alternative projects have met the desired requirements. Bymaleing comprehensive comparison of lowering temperature at water intake, requirement ofenvironmental capacity and the cost of engineering, the design unit may select one of the al-ternative.
Keywords:Cooling wate drainage  numerical model  power plant  Fujian